Development and validation of the Skills Assessment in Microsurgery for Brain Aneurysms (SAMBA) instrument for predicting proficiency in aneurysm surgery
OBJECTIVESurgical performance evaluation was first described with the OSATS (Objective Structured Assessment of Technical Skills) and modified for aneurysm microsurgery simulation with the OSAACS (Objective Structured Assessment of Aneurysm Clipping Skills). These methods rely on the subjective opinions of evaluators, however, and there is a lack of objective evaluation for proficiency in the microsurgical treatment of brain aneurysms. The authors present a new instrument, the Skill Assessment in Microsurgery for Brain Aneurysms (SAMBA) scale, which can be used similarly in a simulation model and in the treatment of unruptured middle cerebral artery (MCA) aneurysms to predict surgical performance; the authors also report on its validation.METHODSThe SAMBA scale was created by consensus among 5 vascular neurosurgeons from 2 different neurosurgical departments. SAMBA results were analyzed using descriptive statistics, Cronbach’s alpha indexes, and multivariate ANOVA analyses (p < 0.05).RESULTSExpert, intermediate-level, and novice surgeons scored, respectively, an average of 33.9, 27.1, and 16.4 points in the real surgery and 33.3, 27.3, and 19.4 points in the simulation. The SAMBA interrater reliability index was 0.995 for the real surgery and 0.996 for the simulated surgery; the intrarater reliability was 0.983 (Cronbach’s alpha). In both the simulation and the real surgery settings, the average scores achieved by members of each group (expert, intermediate level, and novice) were significantly different (p < 0.001). Scores among novice surgeons were more diverse (coefficient of variation = 12.4).CONCLUSIONSPredictive validation of the placenta brain aneurysm model has been previously reported, but the SAMBA scale adds an objective scoring system to verify microsurgical ability in this complex operation, stratifying proficiency by points. The SAMBA scale can be used as an interface between learning and practicing, as it can be applied in a safe and controlled environment, such as is provided by a placenta model, with similar results obtained in real surgery, predicting real surgical performance.
Platelet-Rich Emboli in Cerebral Large Vessel Occlusion Are Associated With a Large Artery Atherosclerosis Source
Background and Purpose— Nearly 30% of large vessel occlusion acute ischemic stroke clots are from an unknown source. We assessed histological clot composition in a series of patients with large vessel occlusion and investigated correlations between clot composition and stroke pathogenesis. Methods— As part of the multi-institutional STRIP registry (Stroke Thromboembolism Registry of Imaging and Pathology), consecutive emboli retrieved during mechanical thrombectomy were stained using Martius Scarlett Blue and analyzed using machine learning software. We assessed proportions of red blood cells, fibrin, platelets, and white blood cells. Correlations between clot components and stroke pathogenesis (large artery atherosclerosis, cardioembolism, and stroke of undetermined pathogenesis) were assessed using SPSS22. Results— One hundred five patients were included. The proportion of platelet-rich clots (55.0% versus 21.2%; P =0.005) and percentage of platelet content (22.1±4.2% versus 13.9±14.2%; P =0.03) was significantly higher in the large artery atherosclerosis group compared with the cardioembolic group. The proportion of platelet-rich clots (50.0% versus 21.2%; P =0.024) was also significantly higher in the cryptogenic group compared with cardioembolic cases. Large artery atherosclerosis and cryptogenic cases had a similar proportion of platelet-rich clots (55.0% versus 50.0%; P =0.636). There was no significant difference between stroke pathogenesis and the other major clot components. Conclusions— High platelet content of emboli is associated with a large artery atherosclerosis etiology of large vessel occlusion.
Novel aspiration catheter design for acute stroke thrombectomy
Background Navigable, large diameter aspiration catheters demonstrate markedly improved recanalization rates over smaller lumen devices in suction embolectomy. We evaluated the performance of a novel aspiration catheter system designed to maximize lumen size, and compare it to other commercially available aspiration catheters. Methods The 6F R4Q aspiration catheter system comprises a proximal pusher wire of 117 cm length connected to a distal catheter of 25 cm length. When placed through standard guide catheters and into the cerebral circulation, the proximal catheter makes a tight seal between its outer surface and the guide catheter’s inner surface. During aspiration, in vitro flow rates and tip suction force under gentle retraction were compared among 10 commercially available aspiration catheters and the R4Q system. Results The R4Q 6F, 5F, 4F, and 3F catheters achieved flow rates at least 21.9%, 24.7%, 61.9%, and 244.7% greater than the other catheters tested respectively and the R4Q 6F produced a 140.2% higher tip force than a catheter of similar size. Fluid flow rate in the R4Q 6F increased on retraction into the guide catheter, delivering a 58.2% increase from fully extended to fully retracted. Conclusion The R4Q design demonstrates a substantial increase in aspirated flow rate and suction force due to an increased effective diameter than standard tubular catheter designs tested. The prominent increase in the aspiration parameters measured in vitro supports the potential for improved clinical results during stroke thrombectomy procedures.
Evaluation of previously embolized intracranial aneurysms: inter-and intra-rater reliability among neurosurgeons and interventional neuroradiologists
Background The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. Objective The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. Methods A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0–100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. Results 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Conclusions Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population.
Morbidity and Mortality in Patients With Posterior Circulation Aneurysms Treated With the Pipeline Embolization Device: A Subgroup Analysis of the International Retrospective Study of the Pipeline Embolization Device
Abstract BACKGROUND The safety of Pipeline TM Embolization Device (PED; Medtronic Inc, Dublin, Ireland) in posterior circulation aneurysms is still controversial. OBJECTIVE To study complications associated with the treatment of posterior circulation aneurysms by conducting a subgroup analysis from the International Retrospective Study of PED registry. METHODS Data from 91 consecutive patients with 95 posterior circulation aneurysms at 17 centers between July 2008 to February 2013 were analyzed. The primary endpoint was defined as any complication leading to neurological morbidity or death. The outcome predictors were calculated using Kaplan–Meier and Cox regression methods. RESULTS The mean aneurysm size was 13.8 mm. Aneurysm types were saccular (36.8%), fusiform (29.5%), dissecting (28.4%), and others (5.3%). The median follow-up was 21.1 mo. Twelve (13.2%) patients encountered a primary endpoint event. In multivariate analysis for the primary endpoint, use of ≥3 PEDs and fusiform shape compared with other shapes had hazard ratios (HRs) of 7.77 (95% confidence interval [CI], 2.48-25.86; P = .0007) and 3.48 (95% CI, 1.06-13.39; P = .0488), respectively. The multivariate HR of aneurysm size for neurological morbidity after PED implantation was 1.11 (95% CI, 1.04-1.18; P = .0015), and HRs of ruptured aneurysm and age for neurological mortality were 8.1 (95% CI, 1.31-41.26; P = .0197) and 1.07 (95% CI, 1.02-1.15; P = .0262), respectively. Basilar artery aneurysm had an HR of 3.54 (95% CI, 1.12-14.18, P = .0529) in the univariate analysis for major outcomes. CONCLUSION PED implantation may be considered for the treatment of posterior circulation aneurysms, especially of saccular or dissecting type. Our major complications appear to be comparable to those reported previously after clipping and coiling in the literature. Neurointerventionists should consider the shape, size, rupture, and location of complex posterior circulation aneurysms as well as age and PED number before the PED placement.
GEL THE NEC: a prospective registry evaluating the safety, ease of use, and efficacy of the HydroSoft coil as a finishing device
Background and purpose The HydroSoft coil was developed as a finishing coil, ideally to be placed along the aneurysm neck to enhance intracranial aneurysm healing. The GEL THE NEC (Gaining Efficacy Long Term: Hydrosoft, an Emerging, New, Embolic Coil) multicenter registry was developed to assess the safety and efficacy of HydroSoft coils in treating intracranial aneurysms. We report angiographic and clinical results of this prospective registry. Materials and methods GEL THE NEC was performed at 27 centers in five countries. Patients aged 21–90 years with a ruptured or unruptured aneurysm 3–15 mm in size were eligible for enrollment. The following variables were obtained: demographics/comorbidities, aneurysm geometry, adjunctive devices used, proportion of patients in whom HydroSoft coils were successfully placed, and long-term angiographic outcomes (graded by an independent core laboratory using the Modified Raymond Scale), and procedure-related adverse events. Predictors of good angiographic outcome were studied using χ2 and t-tests. Results A total of 599 patients with 599 aneurysms were included in this study. HydroSoft coils were successfully deployed in 577 (96.4%) patients. Procedure-related major morbidity and mortality were 0.5% (3/599) and 1.3% (8/599), respectively. The most common perioperative complications were iatrogenic vasospasm (30/599, 5.0%), thromboemboli (27/599, 4.5%), and aneurysm perforation (16/599, 2.7%). At last angiographic follow-up (mean 9.0±6.3 months), the complete occlusion rate was 63.2% (280/442) and near complete occlusion rate was 25.2% (107/442). The core laboratory read recanalization rate was 10.8% (46/425) and the retreatment rate was 3.4% (20/599). Conclusions Endovascular treatment of intracranial aneurysms with HydroSoft coils resulted in complete/near complete occlusion rates of 88% and a major complication rate of 1.8%. Trial registration number NCT01000675.
Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies
OBJECTIVEThe authors performed a pooled analysis of 3 studies—IntrePED (International Retrospective Study of the Pipeline Embolization Device), PUFS (Pipeline for Uncoilable or Failed Aneurysms Study), and ASPIRe (Aneurysm Study of Pipeline in an Observational Registry)—in order to assess angiographic outcomes and clinical safety of the Pipeline embolization device (PED).METHODSIntrePED was a retrospective study, while PUFS and ASPIRe were prospective studies. For each patient included in these studies, the authors collected baseline demographic data, aneurysm characteristics, and procedural details. The primary outcomes for this combined analysis were clinical outcomes, including neurological morbidity and mortality and major ipsilateral intracranial hemorrhage and ischemic stroke. The secondary outcomes were angiographic occlusion rates, which were available for ASPIRe and PUFS only.RESULTSA total of 1092 patients with 1221 aneurysms were included across the 3 studies. The mean aneurysm size was 12.0 ± 7.8 mm and the mean neck size was 6.6 ± 4.8 mm. The major ipsilateral ischemic stroke rate was 3.7% (40/1091). The major ipsilateral intracranial hemorrhage rate was 2.0% (22/1091). The major neurological morbidity rate was 5.7% (62/1091). The neurological mortality rate was 3.3% (36/1091). The combined major morbidity and neurological mortality rate was 7.1% (78/1091). The complete occlusion rates were 75.0% at 180 days (111/148) and 85.5% at 1 year (94/110). The overall aneurysm retreatment rate was 3.0% (33/1091) at a mean follow-up time of 10.2 ± 10.8 months.CONCLUSIONSEndovascular treatment of intracranial aneurysms with the PED is safe and effective. Angiographic occlusion rates progressed with follow-up. Rates of stroke, hemorrhage, morbidity and mortality, and retreatment were low, especially given the fact that the aneurysms treated were generally large and wide necked.
The fate of cranial neuropathy after flow diversion for carotid aneurysms
OBJECT The authors sought to determine whether flow diversion with the Pipeline Embolization Device (PED) can approximate microsurgical decompression in restoring function after cranial neuropathy following carotid artery aneurysms. METHODS This multiinstitutional retrospective study involved 45 patients treated with PED across the United States. All patients included presented between November 2009 and October 2013 with cranial neuropathy (cranial nerves [CNs] II, III, IV, and VI) due to intracranial aneurysm. Outcome analysis included clinical and procedural variables at the time of treatment as well as at the latest clinical and radiographic follow-up. RESULTS Twenty-six aneurysms (57.8%) were located in the cavernous segment, while 6 (13.3%) were in the clinoid segment, and 13 (28.9%) were in the ophthalmic segment of the internal carotid artery. The average aneurysm size was 18.6 mm (range 4–35 mm), and the average number of flow diverters placed per patient was 1.2. Thirty-eight patients had available information regarding duration of cranial neuropathy prior to treatment. Eleven patients (28.9%) were treated within 1 month of symptom onset, while 27 (71.1%) were treated after 1 month of symptoms. The overall rate of cranial neuropathy improvement for all patients was 66.7%. The CN deficits resolved in 19 patients (42.2%), improved in 11 (24.4%), were unchanged in 14 (31.1%), and worsened in 1 (2.2%). Overtime, the rate of cranial neuropathy improvement was 33.3% (15/45), 68.8% (22/32), and 81.0% (17/21) at less than 6, 6, and 12 months, respectively. At last follow-up, 60% of patients in the isolated CN II group had improvement, while in the CN III, IV, or VI group, 85.7% had improved. Moreover, 100% (11/11) of patients experienced improvement if they were treated within 1 month of symptom onset, whereas 44.4% (12/27) experienced improvement if they treated after 1 month of symptom onset; 70.4% (19/27) of those with partial deficits improved compared with 30% (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality.
Flow diversion for complex intracranial aneurysms in young children
Pediatric intracranial aneurysms are exceedingly rare and account for less than 5% of all intracranial aneurysms. Open surgery to treat such aneurysms has been shown to be more durable than endovascular techniques, and durability of treatment is particularly important in the pediatric population. Over the past 2 decades, however, a marked shift in aneurysm treatment from open surgery toward endovascular procedures has occurred for adults. The authors describe their early experience in treating 3 unruptured pediatric brain aneurysms using the Pipeline embolization device (PED). The first patient, a girl with Majewski osteodysplastic primordial dwarfism Type II who was harboring multiple intracranial aneurysms, underwent two flow diversion procedures for a vertebrobasilar aneurysm and a supraclinoid internal carotid artery aneurysm. The second patient underwent PED placement on a previously coiled but enlarging posterior communicating artery aneurysm. All procedures were uneventful, with no postsurgical complications, and led to complete angiographic obliteration of the aneurysms. To the authors' knowledge, this is the first series of flow diversion procedures in children reported in the medical literature. While flow diversion is a new and relatively untested technology in children, outcomes in adults have been promising. For challenging lesions in the pediatric population, flow diversion may have a valuable role as a well-tolerated, safe treatment with durable results. Many issues remain to be addressed, such as the durability of flow diverters over a very long follow-up and vessel response to growth in the presence of an endoluminal device.
From the notch to a glioma grading system: the neurological contributions of James Watson Kernohan
During his lifetime and a career spanning 42 years, James Watson Kernohan made numerous contributions to neuropathology, neurology, and neurosurgery. One of these, the phenomenon of ipsilateral, false localizing signs caused by compression of the contralateral cerebral peduncle against the tentorial edge, has widely become known as “Kernohan's notch” and continues to bear his name. The other is a grading system for gliomas from a neurosurgical viewpoint that continues to be relevant for grading of glial tumors 60 years after its introduction. In this paper, the authors analyze these two major contributions in detail within the context of Kernohan's career and explore how they contributed to the development of neurosurgical procedures.