Back to Authors

Ferrarez, Carlos Eduardo

https://orcid.org/0000-0003-0854-5817

Mayo Clinic

Placentarium, Belo Horizonte;

Citations 2

Development and validation of the Skills Assessment in Microsurgery for Brain Aneurysms (SAMBA) instrument for predicting proficiency in aneurysm surgery
Oliveira, Marcelo Magaldi Ribeiro de , Ramos, Taise Mosso, Ferrarez, Carlos Eduardo , Alvarenga, Daniel L., Soares, Carolina K., Mainart, Luiza M., Aguilar‐Salinas, Pedro , Gusmão, Sebastião , Sauvageau, Eric , Machado, Carla Jorge , Costa, Pollyana Helena Vieira , Soares, Carolina Kuchenbecker , Hanel, Ricardó A. , Lanzino, Giuseppe

Journal of Neurosurgery | June 14, 2019 | Volume: 133 | Issue: 1 | Pages: 190-196

10.3171/2018.7.jns173007 Get It

OBJECTIVESurgical performance evaluation was first described with the OSATS (Objective Structured Assessment of Technical Skills) and modified for aneurysm microsurgery simulation with the OSAACS (Objective Structured Assessment of Aneurysm Clipping Skills). These methods rely on the subjective opinions of evaluators, however, and there is a lack of objective evaluation for proficiency in the microsurgical treatment of brain aneurysms. The authors present a new instrument, the Skill Assessment in Microsurgery for Brain Aneurysms (SAMBA) scale, which can be used similarly in a simulation model and in the treatment of unruptured middle cerebral artery (MCA) aneurysms to predict surgical performance; the authors also report on its validation.METHODSThe SAMBA scale was created by consensus among 5 vascular neurosurgeons from 2 different neurosurgical departments. SAMBA results were analyzed using descriptive statistics, Cronbach’s alpha indexes, and multivariate ANOVA analyses (p < 0.05).RESULTSExpert, intermediate-level, and novice surgeons scored, respectively, an average of 33.9, 27.1, and 16.4 points in the real surgery and 33.3, 27.3, and 19.4 points in the simulation. The SAMBA interrater reliability index was 0.995 for the real surgery and 0.996 for the simulated surgery; the intrarater reliability was 0.983 (Cronbach’s alpha). In both the simulation and the real surgery settings, the average scores achieved by members of each group (expert, intermediate level, and novice) were significantly different (p < 0.001). Scores among novice surgeons were more diverse (coefficient of variation = 12.4).CONCLUSIONSPredictive validation of the placenta brain aneurysm model has been previously reported, but the SAMBA scale adds an objective scoring system to verify microsurgical ability in this complex operation, stratifying proficiency by points. The SAMBA scale can be used as an interface between learning and practicing, as it can be applied in a safe and controlled environment, such as is provided by a placenta model, with similar results obtained in real surgery, predicting real surgical performance.
Learning brain aneurysm microsurgical skills in a human placenta model: predictive validity
Oliveira, Marcelo Magaldi Ribeiro de , Ferrarez, Carlos Eduardo , Ramos, Taise Mosso, Malheiros, José Augusto , Nicolato, Arthur Adolfo, Machado, Carla Jorge , Ferreira, Mauro Tostes, Oliveira, Fellype Borges de , Sousa, C.F.P.M. de , Gusmão, Sebastião , Maestro, Rolando F. Del , Costa, Pollyana Helena Vieira , Lanzino, Giuseppe

Journal of Neurosurgery | March 24, 2017 | Volume: 128 | Issue: 3 | Pages: 846-852

10.3171/2016.10.jns162083 Get It

OBJECTIVESurgery for brain aneurysms is technically demanding. In recent years, the process to learn the technical skills necessary for these challenging procedures has been affected by a decrease in the number of surgical cases available and progressive restrictions on resident training hours. To overcome these limitations, surgical simulators such as cadaver heads and human placenta models have been developed. However, the effectiveness of these models in improving technical skills is unknown. This study assessed concurrent and predictive validity of brain aneurysm surgery simulation in a human placenta model compared with a “live” human brain cadaveric model.METHODSTwo human cadaver heads and 30 human placentas were used. Twelve neurosurgeons participated in the concurrent validity part of this study, each operating on 1 human cadaver head aneurysm model and 1 human placenta model. Simulators were evaluated regarding their ability to simulate different surgical steps encountered during real surgery. The time to complete the entire aneurysm task in each simulator was analyzed. The predictive validity component of the study involved 9 neurosurgical residents divided into 3 groups to perform simulation exercises, each lasting 6 weeks. The training for the 3 groups consisted of educational video only (3 residents), human cadaver only (3 residents), and human placenta only (3 residents). All residents had equivalent microsurgical experience with superficial brain tumor surgery. After completing their practice training, residents in each of the 3 simulation groups performed surgery for an unruptured middle cerebral artery (MCA) aneurysm, and their performance was assessed by an experienced vascular neurosurgeon who watched the operative videos.RESULTSAll human cadaver heads and human placentas were suitable to simulate brain aneurysm surgery. In the concurrent validity portion of the experiment, the placenta model required a longer time (p < 0.001) than cadavers to complete the task. The placenta model was considered more effective than the cadaver model in simulating sylvian fissure splitting, bipolar coagulation of oozing microvessels, and aneurysm neck and dome dissection. Both models were equally effective in simulating neck aneurysm clipping, while the cadaver model was considered superior for simulation of intraoperative rupture and for reproduction of real anatomy during simulation. In the predictive validity portion of the experiment, residents were evaluated for 4 tasks: sylvian fissure dissection, microvessel bipolar coagulation, aneurysm dissection, and aneurysm clipping. Residents trained in the human placenta simulator consistently had the highest overall performance scores when compared with those who had trained in the cadaver model and those who had simply watched operative videos (p < 0.001).CONCLUSIONSThe human placenta biological simulator provides excellent simulation for some critical tasks of aneurysm surgery such as splitting of the sylvian fissure, dissection of the aneurysm neck and dome, and bipolar coagulation of surrounding microvessels. When performing surgery for an unruptured MCA aneurysm, residents who had trained in the human placenta model performed better than residents trained with other simulation scenarios/models. In this age of reduced exposure to aneurysm surgery and restrictions on resident working hours, the placenta model is a valid simulation for microneurosurgery with striking similarities with real surgery.