Back to Authors

Brown, Benjamin L.

https://orcid.org/0000-0002-1213-0588

Mayo Clinic

Ochsner Health System

Citations 9

Association that Neuroimaging and Clinical Measures Have with Change in Arm Impairment in a Phase 3 Stroke Recovery Trial
Schwarz, Anne , Feldman, Marc D., Le, Vu , Dawson, Jesse, Francisco, Gerard E., Wolf, Steven L., Dixit, Anand, Alexander, Jen , Ali, Rushna , Brown, Benjamin L. , Feng, Wuwei , DeMark, Lou , Hochberg, Leigh R. , Majid, Arshad , O’Dell, Michael W. , Redgrave, Jessica, Cramer, Steven C. , Feng, Wuwei , Cramer, Steven C , Dawson, Jesse , Liu, Charles Y. , Francisco, Gerard E. , Kautz, Steven A. , Turner, Duncan L. , Kimberley, Teresa Jacobson

Annals of Neurology | December 16, 2024 | Volume: 97 | Issue: 4 | Pages: 709-719

10.1002/ana.27156 Get It

ObjectiveVagus nerve stimulation (VNS) paired with rehabilitation therapy improved motor status compared to rehabilitation alone in the phase III VNS‐REHAB stroke trial, but treatment response was variable and not associated with any clinical measures acquired at baseline, such as age or side of paresis. We hypothesized that neuroimaging measures would be associated with treatment‐related gains, examining performance of regional injury measures versus global brain health measures in parallel with clinical measures.MethodsBaseline magnetic resonance imaging (MRI) scans in the VNS‐REHAB trial were used to derive regional injury measures (extent of injury to corticospinal tract, the primary regional measure; plus extent of injury to precentral gyrus and postcentral gyrus; lesion volume; and lesion topography) and global brain health measures (degree of white matter hyperintensities, the primary global brain measure; plus volumes of cerebrospinal fluid, cortical gray matter, white matter, each thalamus, and total brain). Eight clinical measures assessed at baseline were also evaluated (treatment group, age, race, gender, paretic side, pre‐stroke dominant hand, time since stroke, and baseline Fugl‐Meyer upper extremity score). Bivariate analyses compared each measure with the primary trial end point (change in Fugl‐Meyer upper extremity score from baseline to end of 6 weeks of treatment) across all subjects, with secondary analyses examining trial groups separately.ResultsMRIs were available from 80 patients (age = 59.8 ± 9.5 years, 29 women). Across all patients, less white matter hyperintensities (r = −0.25, p = 0.028) at baseline was associated with larger Fugl‐Meyer score change. In the VNS group, less white matter hyperintensities (r = −0.37, p = 0.018) and larger ipsilesional thalamus volume (r = 0.33, p = 0.046) were each associated with larger Fugl‐Meyer score change. Analysis of covariance (ANCOVA) analyses tested the interaction that each baseline measure had with treatment group and found that the model examining white matter hyperintensities had a significant interaction term, indicating 2.3 less change in Fugl‐Meyer Upper Extremity (FM‐UE) points in the VNS group relative to the control group for each point increase in modified Fazekas scale.InterpretationNeuroimaging measures are associated with extent of gains on the primary endpoint of a phase III stroke recovery trial. Among the neuroimaging measures examined, a measure of global brain health (extent of white matter hyperintensities) was better at explaining the change in arm impairment as compared with measures of regional injury; this was true when examining all study subjects as well as only those in the VNS group and is consistent with the global mechanism of action that VNS has throughout the cerebrum. Future studies can evaluate additional measures that further predict response to VNS therapy. The current findings suggest that individual patient neuroimaging results may be useful for a personalized medicine approach to stroke recovery therapeutics. ANN NEUROL 2025;97:709–719
Topographic correlation of infarct area on CT perfusion with functional outcome in acute ischemic stroke
Haranhalli, Neil , Mbabuike, Nnenna, Hasan, Tasneem F. , Brown, Benjamin L. , Miller, David A. , Vibhute, Prasanna , Grewal, Sanjeet S. , Heckman, Michael G. , Freeman, William D. , Gupta, Vivek , Jahromi, Babak S. , Tawk, Rabih G.

Journal of Neurosurgery | February 27, 2019 | Volume: 132 | Issue: 1 | Pages: 33-41

10.3171/2018.8.jns181095 Get It

OBJECTIVEThe role of CT perfusion (CTP) in the management of patients with acute ischemic stroke (AIS) remains a matter of debate. The primary aim of this study was to evaluate the correlation between the areas of infarction and penumbra on CTP scans and functional outcome in patients with AIS.METHODSThis was a retrospective review of 100 consecutively treated patients with acute anterior circulation ischemic stroke who underwent CT angiography (CTA) and CTP at admission between February 2011 and October 2014. On CTP, the volume of ischemic core and penumbra was measured using the Alberta Stroke Program Early CT Score (ASPECTS). CTA findings were also noted, including the site of occlusion and regional leptomeningeal collateral (rLMC) score. Functional outcome was defined by modified Rankin Scale (mRS) score obtained at discharge. Associations of CTP and CTA parameters with mRS scores at discharge were assessed using multivariable proportional odds logistic regression models.RESULTSThe median age was 67 years (range 19–95 years), and the median NIH Stroke Scale score was 16 (range 2–35). In a multivariable analysis adjusting for potential confounding variables, having an infarct on CTP scans in the following regions was associated with a worse mRS score at discharge: insula ribbon (p = 0.043), perisylvian fissure (p < 0.001), motor strip (p = 0.007), M2 (p < 0.001), and M5 (p = 0.023). A worse mRS score at discharge was more common in patients with a greater volume of infarct core (p = 0.024) and less common in patients with a greater rLMC score (p = 0.004).CONCLUSIONSThe results of this study provide evidence that several CTP parameters are independent predictors of functional outcome in patients with AIS and have potential to identify those patients most likely to benefit from reperfusion therapy in the treatment of AIS.
Augmented reality for the surgeon: Systematic review
Yoon, Jang W. , Chen, Robert E., Kim, Esther J. , Kerezoudis, Panagiotis , Han, Phillip K., Si, Phong, Diaz, Roberto J. , Komotar, Ricardo J. , Pirris, Stephen M. , Brown, Benjamin L. , Bydon, Mohamad , Wang, Michael Y. , Wharen, Robert E. , Quiñones‐Hinojosa, Alfredo , Akinduro, Oluwaseun O. , Freeman, William D.

The International Journal of Medical Robotics and Computer Assisted Surgery | April 30, 2018 | Volume: 14 | Issue: 4 | Pages: No page available

10.1002/rcs.1914 Get It

AbstractIntroductionSince the introduction of wearable head‐up displays, there has been much interest in the surgical community adapting this technology into routine surgical practice.MethodsWe used the keywords augmented reality OR wearable device OR head‐up display AND surgery using PubMed, EBSCO, IEEE and SCOPUS databases. After exclusions, 74 published articles that evaluated the utility of wearable head‐up displays in surgical settings were included in our review.ResultsAcross all studies, the most common use of head‐up displays was in cases of live streaming from surgical microscopes, navigation, monitoring of vital signs, and display of preoperative images. The most commonly used head‐up display was Google Glass. Head‐up displays enhanced surgeons' operating experience; common disadvantages include limited battery life, display size and discomfort.ConclusionsDue to ergonomic issues with dual‐screen devices, augmented reality devices with the capacity to overlay images onto the surgical field will be key features of next‐generation surgical head‐up displays.
Technical feasibility and safety of image‐guided parieto‐occipital ventricular catheter placement with the assistance of a wearable head‐up display
Yoon, Jang W. , ReFaey, Karim , Diaz, Roberto J. , Reimer, Ronald, Komotar, Ricardo J., Quiñones‐Hinojosa, Alfredo , Brown, Benjamin L. , Wharen, Robert E. , Diaz, Roberto J , Chen, Robert E. , ReFaey, Karim

The International Journal of Medical Robotics and Computer Assisted Surgery | May 19, 2017 | Volume: 13 | Issue: 4 | Pages: No page available

10.1002/rcs.1836 Get It

AbstractBackgroundWearable technology is growing in popularity as a result of its ability to interface with normal human movement and function.MethodsUsing proprietary hardware and software, neuronavigation images were captured and transferred wirelessly via a password‐encrypted network to the head‐up display. The operating surgeon wore a loupe‐mounted wearable head‐up display during image‐guided parieto‐occipital ventriculoperitoneal shunt placement in two patients.ResultsThe shunt placement was completed successfully without complications. The tip of the catheter ended well within the ventricles away from the ventricular wall. The wearable device allowed for continuous monitoring of neuronavigation images in the right upper corner of the surgeon's visual field without the need for the surgeon to turn his head to view the monitors.ConclusionsThe adaptable nature of this proposed system permits the display of video data to the operating surgeon without diverting attention away from the operative task. This technology has the potential to enhance image‐guided procedures.
Ambulance-based assessment of NIH Stroke Scale with telemedicine: A feasibility pilot study
Barrett, Kevin M. , Pizzi, Michael , Kesari, Vivek , TerKonda, Sarvam P. , Mauricio, Elizabeth A. , Silvers, Scott M., Habash, Ranya, Brown, Benjamin L. , Wharen, Robert E. , Freeman, William D. , Pizzi, Michael A. , Wharen, Robert, Mauricio, Elizabeth A. , Tawk, Rabih G. , Meschia, James F. , Freeman, William D

Journal of Telemedicine and Telecare | May 13, 2016 | Volume: 23 | Issue: 4 | Pages: 476-483

10.1177/1357633x16648490 Get It

Background Ischemic stroke is a time-sensitive disease, with improved outcomes associated with decreased time from onset to treatment. It was hypothesised that ambulance-based assessment of the National Institutes of Health Stroke Scale (NIHSS) using a Health Insurance Portability and Accountability Act (HIPAA)–compliant mobile platform immediately prior to arrival is feasible. Methods This is a proof-of-concept feasibility pilot study in two phases. The first phase consisted of an ambulance-equipped HIPAA-compliant video platform for remote NIHSS assessment of a simulated stroke patient. The second phase consisted of remote NIHSS assessment by a hospital-based neurologist of acute stroke patients en route to our facility. Five ambulances were equipped with a 4G/LTE-enabled tablet preloaded with a secure HIPAA-compliant telemedicine application. Secondary outcomes assessed satisfaction of staff with the remote platform. Results Phase one was successful in the assessment of three out of three simulated patients. Phase two was successful in the assessment of 10 out of 11 (91%) cases. One video attempt was unsuccessful because local LTE was turned off on the device. The video signal was dropped transiently due to weather, which delayed NIHSS assessment in one case. Average NIHSS assessment time was 7.6 minutes (range 3–9.8 minutes). Neurologists rated 83% of encounters as ‘satisfied’ to ‘very satisfied’, and the emergency medical service (EMS) rated 90% of encounters as ‘satisfied’ to ‘very satisfied’. The one failed video attempt was associated with ‘poor’ EMS satisfaction. Conclusion This proof-of-concept pilot demonstrates that remote ambulance-based NIHSS assessment is feasible. This model could reduce door-to-needle times by conducting prehospital data collection.
Accuracy of CT angiography in detection of blood supply dominance of posterior cerebral artery in patients with posterior communicating artery aneurysm
Ahmed, Osama , Kalakoti, Piyush , Menger, Richard , Brown, Benjamin L. , Guthikonda, Bharat , Brown, Benjamin, Zhang, Shihao , Cuellar, Hugo

The Neuroradiology Journal | October 29, 2015 | Volume: 28 | Issue: 6 | Pages: 598-603

10.1177/1971400915615082 Get It

Background and purpose The use of computed tomography angiography (CTA) as the sole vascular imaging study for preoperative planning for clipping of aneurysms is well described in the literature. CTA is widely available, provides quick acquisition, has low morbidity, and low cost. In this study, we describe the accuracy of CTA in determining the blood supply dominance in comparison to standard digital subtraction angiography. Materials and methods Sixty-six patients, with both CTAs and angiograms, were reviewed by two independent neuroradiologists. The posterior cerebral artery was determined to have dominant supply from the posterior communicating artery if it was of similar size to the P2 segment and the P1 segment was smaller by approximately 50%. If the posterior communicating artery and P1 segment were the same size, it was considered to have a dual supply. If P1 and P2 segments were the same caliber and the posterior communicating artery was smaller by 50%, it was deemed to have posterior circulation dominance. Results Based on the findings of our reviewers, CTA had a sensitivity and specificity of 69% and 96%, respectively, in predicting the presence of a fetal PCA. The positive predictive value was found to be 82% while a negative predictive value was estimated as 93%. A small-caliber P1 segment and large-caliber posterior communicating artery led to inaccurate interpretations of the CTAs. Conclusion This study shows that one cannot accurately predict blood supply dominance of the posterior cerebral artery. Knowledge of the blood flow dominance is essential when clipping a posterior communicating artery aneurysm to avoid compromise in posterior circulation.
The fate of cranial neuropathy after flow diversion for carotid aneurysms
Brown, Benjamin L. , Miller, David A. , Brasiliense, Leonardo B.C. , Ringer, Andrew J. , Sauvageau, Eric , Powers, Ciarán J. , Hoit, Daniel , Siddiqui, Adnan H. , Hopkins, L. Nelson , Rodríguez‐Mercado, Rafael, Veznedaroglu, Erol, Binning, Mandy J., Aguilar‐Salinas, Pedro , Boulos, Alan S. , Lopes, Demetrius K. , Tawk, Rabih G. , Arthur, Adam Stephen , Snyder, Kenneth V. , Levy, Elad I. , Cuellar, Hugo , Mocco, J , Yamamoto, Junichi , Hanel, Ricardó A. , Siddiqui, Adnan H

Journal of Neurosurgery | October 16, 2015 | Volume: 124 | Issue: 4 | Pages: 1107-1113

10.3171/2015.4.jns142790 Get It

OBJECT The authors sought to determine whether flow diversion with the Pipeline Embolization Device (PED) can approximate microsurgical decompression in restoring function after cranial neuropathy following carotid artery aneurysms. METHODS This multiinstitutional retrospective study involved 45 patients treated with PED across the United States. All patients included presented between November 2009 and October 2013 with cranial neuropathy (cranial nerves [CNs] II, III, IV, and VI) due to intracranial aneurysm. Outcome analysis included clinical and procedural variables at the time of treatment as well as at the latest clinical and radiographic follow-up. RESULTS Twenty-six aneurysms (57.8%) were located in the cavernous segment, while 6 (13.3%) were in the clinoid segment, and 13 (28.9%) were in the ophthalmic segment of the internal carotid artery. The average aneurysm size was 18.6 mm (range 4–35 mm), and the average number of flow diverters placed per patient was 1.2. Thirty-eight patients had available information regarding duration of cranial neuropathy prior to treatment. Eleven patients (28.9%) were treated within 1 month of symptom onset, while 27 (71.1%) were treated after 1 month of symptoms. The overall rate of cranial neuropathy improvement for all patients was 66.7%. The CN deficits resolved in 19 patients (42.2%), improved in 11 (24.4%), were unchanged in 14 (31.1%), and worsened in 1 (2.2%). Overtime, the rate of cranial neuropathy improvement was 33.3% (15/45), 68.8% (22/32), and 81.0% (17/21) at less than 6, 6, and 12 months, respectively. At last follow-up, 60% of patients in the isolated CN II group had improvement, while in the CN III, IV, or VI group, 85.7% had improved. Moreover, 100% (11/11) of patients experienced improvement if they were treated within 1 month of symptom onset, whereas 44.4% (12/27) experienced improvement if they treated after 1 month of symptom onset; 70.4% (19/27) of those with partial deficits improved compared with 30% (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality.
Anterior communicating artery aneurysm: Accuracy of CT angiography in determination of inflow dominance
Ahmed, Osama , Brown, Benjamin L. , Toms, Jaime, Gonzalez‐Toledo, Eduardo, Guthikonda, Bharat , Zhang, Shihao , Cuellar, Hugo

The Neuroradiology Journal | August 25, 2015 | Volume: 28 | Issue: 4 | Pages: 389-395

10.1177/1971400915594503 Get It

Background Preoperative assessment of anterior communicating artery (AcoA) aneurysms with cerebral angiography is common, but not without risk. Computed tomography angiography (CTA) is a widely available imaging modality that provides quick acquisition, low morbidity, and low cost. One disadvantage is that it does not provide dynamic information. In this study, the authors sought to determine whether CTA alone can reliably predict the inflow dominance to an AcoA aneurysm. Methods Eighty-three patients with ruptured AcoA aneurysms were reviewed retrospectively. Only those patients with both preoperative CTA and cerebral angiogram were included, thus excluding six patients. Four independent observers reviewed the CTAs and attempted to identify the dominant A1. Additionally, three mathematical models were created to identify the dominant A1. These responses were compared to cerebral angiograms. Results Four observers were correct in judging the dominant A1 an average of 93% of the time. Seventeen cases were read incorrectly by only one of four observers, and three cases were read incorrectly by two observers. For cases with incorrect readings, the average percentage difference in A1 sizes was 19.6%. For cases read unanimously correct, the average percentage difference in A1 sizes was 42.7%. Mathematical model #3 correctly evaluated the dominant A1 in 97% of the cases. Conclusions This study found CT angiograms can be reliable in predicting the inflow dominance to the majority of AcoA aneurysms.
Flow diversion for complex intracranial aneurysms in young children
Navarro, Ramón, Brown, Benjamin L. , Beier, Alexandra D., Ranalli, Nathan J., Aldana, Philipp R. , Hanel, Ricardó A.

Journal of Neurosurgery: Pediatrics | January 2, 2015 | Volume: 15 | Issue: 3 | Pages: 276-281

10.3171/2014.9.peds14333 Get It

Pediatric intracranial aneurysms are exceedingly rare and account for less than 5% of all intracranial aneurysms. Open surgery to treat such aneurysms has been shown to be more durable than endovascular techniques, and durability of treatment is particularly important in the pediatric population. Over the past 2 decades, however, a marked shift in aneurysm treatment from open surgery toward endovascular procedures has occurred for adults. The authors describe their early experience in treating 3 unruptured pediatric brain aneurysms using the Pipeline embolization device (PED). The first patient, a girl with Majewski osteodysplastic primordial dwarfism Type II who was harboring multiple intracranial aneurysms, underwent two flow diversion procedures for a vertebrobasilar aneurysm and a supraclinoid internal carotid artery aneurysm. The second patient underwent PED placement on a previously coiled but enlarging posterior communicating artery aneurysm. All procedures were uneventful, with no postsurgical complications, and led to complete angiographic obliteration of the aneurysms. To the authors' knowledge, this is the first series of flow diversion procedures in children reported in the medical literature. While flow diversion is a new and relatively untested technology in children, outcomes in adults have been promising. For challenging lesions in the pediatric population, flow diversion may have a valuable role as a well-tolerated, safe treatment with durable results. Many issues remain to be addressed, such as the durability of flow diverters over a very long follow-up and vessel response to growth in the presence of an endoluminal device.