Abstract Background Monoclonal antibody therapies (t-mabs) are known to interfere in serum immunofixation, as they show up as a discrete band. Until recently, most of the t-mabs were IgG kappa monoclonal immunoglobulins, and laboratories were familiar with the clue of a cathodal migrating IgG kappa in a patient sample, suggesting this could be daratumumab or another t-mab in the report. However, with the advent of novel antibody-based medications, identification via traditional laboratory methods has grown more complex. Teclistamab-cqyv is an IgG4 lambda T-cell engager bispecific antibody targeting B-cell maturation antigen (BCMA) and CD3 on T cells, used in relapsed and refractory multiple myeloma. The goal of this study was to determine if teclistamab could be detected on serum immunofixation and mass-fix. Methods Residual waste serum samples with no monoclonal protein via mass-fix (a MALDI-TOF based assay used in place of serum immunofixation) and variable polyclonal background were used to spike teclistamab (n=3). Briefly, one sample had total IgG < 500 mg/dL measured by nephelometry on a Siemens BNII (431 mg/dL, hypo gamma), a second sample had IgG within reference intervals (779 mg/dL, normal gamma) and the third sample had IgG > 1600 mg/dL (1950 mg/dL, polyclonal hypergamma). Each sample was divided into 3 aliquots and spiked with teclistamab (Tecvayli, Johnson &Johnson) obtained from the pharmacy, at final concentrations of 10, 20, and 40 mg/dL in the serum samples. The nine artificial samples were subjected to immunofixation electrophoresis (Sebia) and a new monoclonal protein study using mass-fix, a laboratory developed test. Results In the serum immunofixation experiments, a single discrete IgG lambda band was visible in the hypogamma and normal gamma samples (Table 1) when teclistamab was present at 20 mg/dL or 40 mg/dL. No bands were observed for the 10 mg/dL spike in hypos or normals. No teclistamab was detected at any concentration in the hypergamma sample. When mass-fix was performed, monoclonal protein spikes consistent with the expected mass of the two unique lambda light chains associated with teclistamab (22624Da and 22636Da) were identified in the hypo and normal gamma samples at the 3 concentrations tested: 10, 20, and 40 mg/dL. No mass-fix spikes were seen above the polyclonal spectra in the hypergamma samples. Conclusion The polyclonal background of immunoglobulins in a serum specimen plays a significant role in the identification of any monoclonal protein. Teclistamab is a new IgG lambda t-mab with potential to show up as an interference in both immunofixation and mass-fix, depending on the amount of polyclonal IgG present. Without positive identification, teclistamab presence could complicate interpretation of a patient’s response to treatment. This proof-of-concept study shows that mass-fix can detect smaller concentrations of teclistamab than immunofixation, therefore would be more prone to identifying this t-mab than labs employing the gel-based immunofixation method.
B-123 Clinical Implication of Light Chain Fragmentation in Patients with Monoclonal Gammopathies
Abstract Background The diagnosis of monoclonal gammopathies relies on the detection of monoclonal immunoglobulins (M-proteins) in serum or urine. Mass-Fix utilizes matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) to detect and quantify M-proteins. This method employs immunoaffinity enrichment using antibodies against heavy chains (HC) and light chains (LC), followed by MS analysis to determine M-protein isotypes. Mass-Fix has also revealed novel M-protein characteristics, including LC glycosylation and fragmentation, facilitated by measuring the mass of LC. LC glycosylation is as an independent risk factor for disease progression of monoclonal gammopathy of undetermined significance (MGUS), while light chain fragments have been postulated as the origin of amyloid light chain (AL) plaques. Since Mass-Fix enriches intact immunoglobulins before dissociating LCs, it potentially enhances fragment detection. However, the precise nature and clinical significance of these fragments remain to be fully elucidated. Methods Mass-Fix serum results from Mayo Clinic patients tested from September 10, 2018, to October 1, 2024, were reviewed for the presence of M-protein and LC fragments. The frequency and the isotype of fragment LC fragments was determined in the M-protein positive cohort (n=15410). Patients diagnosed with either MGUS (n=6996), AL amyloidosis (n=315), or both (n=32) who had positive M-protein results on Mass-Fix, either prior to or within one month after the diagnosis, were included for a retrospective clinical association study of LC fragments and disease. To validate that these fragments were not artifacts of MS analysis, PAGE gel analysis and Western blots were performed using clinical residual serum from 9 patients: 2 IgG/kappa and 3 IgG/lambda patients with detectable LC fragments and 2 IgG/kappa and 2 IgG/lambda patients without fragments. Samples were purified using antibodies against gamma heavy chains and reduced with TCEP prior to gel electrophoresis and Western blot. Results Of the 15410 patients with monoclonal proteins detected by Mass-Fix, 2896 (18.7%) had detectable LC fragments; kappa fragments in 1533 and lambda fragments in 1363. Most often, the fragments were observed in pairs, with combined molecular weight typically equaled that of the full-length monoclonal LC present in the same sample. LC fragments were observed more frequently among patients diagnosed with AL amyloidosis (118/347=34%) compared to those without the diagnosis (685/6996=10%), with an odds ratio of 4.75 (95% CI, 3.75-6.01). PAGE with Coomassie blue staining revealed bands with sizes representing LC fragments in the five M-protein samples with detectable LC fragments on Mass-Fix, while no such bands observed in those without LC fragments. Western blot using anti-kappa or anti-lambda antibodies confirmed the identity of the bands with higher molecular weight as a fragment of LC in each of the IgG/kappa and IgG/lambda samples. Conclusion Mass-Fix is able to discriminate LC fragments from intact LC based on their sizes. The detection of LC fragments with Western blot without ionization suggests a biological origin rather than analytical artifacts from MS. The clinical association study suggests that LC fragments may have utility in increasing the suspicion of AL amyloidosis in M-protein positive patients with LC fragments, potentially facilitating earlier intervention and improving patient outcomes.
B-124 Evaluation of Anti-Citrullinated Peptide Antibody (ACPA) Result Normalization as Defined in the 2010 Rheumatoid Arthritis Classification Criteria Recommended by American College of Rheumatology/Alliance of Associations for Rheumatology (ACR/EULAR)
Abstract Background Anti-citrullinated peptide antibodies (ACPA) (tested as anti-cyclic citrullinated peptide [CCP] antibodies) are frequently ordered in the evaluation of patients with suspected rheumatoid arthritis (RA) and considered to be specific biomarkers for RA. The 2010 American College of Rheumatology/European Alliance of Associations for Rheumatology (ACR/EULAR) classification criteria for RA include both ACPA and rheumatoid factor in their scoring system, despite limited standardization of commercially available anti-CCP antibody tests. In an attempt to overcome this limitation, the classification criteria recommends using multiples of the assay-specific upper limit of normal (ULN) to normalize results and standardize classification. This study evaluates the correlation between normalized results from different assays and the concordance in result classification according to the ACR/EULAR criteria. Methods A total of 265 samples with ACPA ordered as part of routine clinical care were tested on four commercial anti-CCP antibody assays, including QUANTA Lite CCP3 IgG ELISA (Werfen) (Negative: <20 Units), QUANTA Flash CCP3 chemiluminescence immunoassay (Werfen) (Negative: <20 Chemiluminescent Units), EUROIMMUN Anti-CCP ELISA (IgG) (EUROIMMUN) (Negative: <=5 Relative Units/mL), and Elecsys anti-CCP electrochemiluminescence immunoassay (Roche) (Negative: <17.0 Units/mL). The QUANTA Lite and EUROIMMUN ELISA were performed on the Agility platform (Dynex), QUANTA Flash was performed on BioFlash platform (Werfen), and Elecsys anti-CCP was performed on Cobas e601 platform (Roche). All testing was performed according to manufacturer’s instructions. Results from each assay were converted to the multiples of assay-specific ULN as the normalized results. Regression analysis was performed, and the coefficient of determination (R²) was calculated to assess the correlation between paired assays. The concordance in result classification across assays was also investigated using both assay specific cut-offs and the ACR/EULAR criteria-defined cut-offs: Negative (<=1xULN), Low positive (>1xULN and <3xULN), High positive (>=3xULN). Results Using assay-specific cut-offs, 63 samples were negative on all assays. 202 samples were positive on at least one assay, of which 79 (39%) were positive across all assays. The overall concordance of qualitative result was 54% ([63+79]/265). After result normalization using multiples of assay-specific ULNs, the highest correlation was observed between the EUROIMMUN ELISA and Elecsys anti-CCP (R²=0.83), despite differences in methodology and manufacturer. The lowest correlation was observed between QUANTA Lite and QUANTA Flash (R²=0.49), even though both are from the same manufacturer although methodologies differ. When applying the criteria-defined cut-offs, 64 samples were negative on all assays. 130 samples were classified as low positive on at least one assay; however, only 3 (2%) samples were classified as low positive across all assays. 103 samples were classified as high positive on at least one assay, of which 54 (52%) were classified as high positive across all assays. With result normalization, the overall concordance in result classification across all assays using the criteria-defined cut-offs were 46% ([64+3+54]/265). Conclusion Despite normalization using multiplies of assay-specific ULN values, the inter-assay correlation remains suboptimal, and the concordance in result classification is limited. These findings suggest that the anti-CCP antibody results from different assays may not be interchangeable even after normalization as recommended by current criteria, potentially impacting disease classification.
B-036 Paving the path for autonomous mobile robots (AMRs) in the clinical laboratory: A pilot study of Collaborative Robotics (Cobot) Proxie robot for cart movement at Mayo Clinic Laboratories
Abstract Background The use of autonomous mobile robots (AMRs) to move materials/supplies is long-standing in manufacturing/warehouse settings and is expanding into hospitals and clinical laboratories. The recently launched Proxie robot (Collaborative Robotics i.e. Cobot) is an AMR that can autonomously move existing carts between defined locations. However, AMRs pose new challenges compared to traditional lab automation. The aims of this study were to: i) perform functional validation to verify Proxie*s manufacturer performance specifications within the laboratory, ii) assess the risk of using Proxie to deliver laboratory specimens, and iii) pilot the use of the Proxie robot to autonomously deliver loaded carts from the Pathology case intake area to the sorting station at Mayo Clinic Laboratories. Methods Functional validation of Proxie consisted of verifying manufacturer’s performance specifications for the following robot parameters (5 test runs): maximum speed, emergency-stop, and ability to maintain localization, travel autonomously, stop and/or avoid moving/fixed objects, and park/unpark. Risk assessment for the robotic use case was performed by a multi-disciplinary team utilizing an AMR risk assessment tool developed by the institutional robotics group. Hazards were categorized as mechanical, electrical, noise, ergonomic, environmental, material/substance or combination risks. Injury severity, exposure(frequency), and avoidance scores were assigned to each hazard to determine negligible-, low-, medium-, high- or very high-risk levels. Proxie’s workstream was evaluated weekly over four weeks by measuring number of cart deliveries, total time/miles traveled, % autonomous deliveries(goal >80%), % on-time deliveries, average±standard deviation(SD) time (min:sec±min:sec) for delivery/return trips, and dwell times at intake/sorting stations. Results Manufacturer’s performance specifications were verified in 100% of test runs. Proxie traveled at human walking speed, stopped within 1 second of emergency stop being enabled, maintained localization, and traveled autonomously for =5 consecutive workflow cycles. Proxie navigated through spaces =4’ wide along fixed pathways and stopped safely when encountering obstacles. Proxie navigated around people and carts in the main 6’ hallway if they were blocking <2’ hallway width. For objects blocking >2’, Proxie stopped and resumed motion after the object moved. After task completion, Proxie side-shifted into the AMR parking space stopping no closer than 7.8” from any object. Twenty-four potential hazards were identified through the risk assessment tool with all risk levels scored as negligible or low. Proxie completed 304 cart deliveries/returns operating 17:35 hours and traveling 11.5 miles during the pilot. The % autonomous deliveries for week 1-4 was 82%,88%,91% and 88%, respectively with =99% on-time deliveries. Delivery from pathology case intake to sorting station averaged 5:43±0:25 min and return trips averaged 3:32±0:34. Proxie dwell times were 13:10±0:33 and 37:34±0:23 min at the pathology intake and sorting stations, respectively. Conclusions The Proxie AMR was capable of successfully and autonomously moving carts with laboratory specimens between the pathology intake and sorting stations of the laboratory during the pilot study. Adding Proxie to this workstream translated to eliminating 5,800 steps and 4 hours 24 min of human cart-pushing per week. Incorporating Proxie into laboratory operations as a cart-moving AMR would increase efficiency and allow laboratory staff to focus on technical, non-repetitive work.
A-368 Point of Care Testing Expedites Treatments Provided by Community Paramedics
Abstract Background Community Paramedic (CP) programs use specially trained paramedics to provide healthcare in the community to increase access to care, reduce unnecessary emergency department visits, and improve timeliness of care. Mayo Clinic in Rochester, MN recently launched a CP Program to provide in-home care for patients who require regular intravenous medications, wound care, diuresis for heart failure, medication reconciliation, care plan compliance/education. CP utilizes i-STAT1 CHEM8+ and Lactate (CG4+) testing (Abbott Point of Care, Abbott Park, IL) to make therapy decisions primarily for heart failure patients based on rapid laboratory results. Having results available at the point of care (POC) eliminates delays between testing and treatments, expediting care for the patient. Prior to using i-STAT, CP traveled to the patient’s residence, drew blood tubes, delivered the tubes to Mayo Clinic, waited for test results, returned to the patient’s home, and provided treatment. In this observational study, we assessed the benefit of in-home POC i-STAT1 testing performed by our CP Program to improve patient care and increase efficiency. Methods Patients within a 40-mile radius of Mayo Clinic were eligible to receive CP service. Whole blood venous specimens were collected and tested using the i-STAT1 CHEM8+ metabolic panel cartridge according to manufacturer instructions to measure: ionized calcium, chloride, glucose, hematocrit, total carbon dioxide, blood urea nitrogen, creatinine, potassium, sodium, anion gap while the i-STAT1 CG4+ cartridge measures lactate. The laboratory information system was used to extract laboratory results, and Excel (Microsoft, Redmond, WA) was used to filter data and perform calculations. Results November 2022 through December 2024, CP performed testing with 353 i-STAT cartridges (3862 tests) on 102 unique patients who each had 1-12 separate orders. Patient ages were 25 to 97 years. 41.2% (1590/3862) of the individual results obtained were outside of our reference intervals (23.0% high, 18.0% low), with 10.8% being ionized calcium, 10.2% chloride, 10.3% glucose, 13.0% hematocrit, 7.6% total carbon dioxide, 18.2% blood urea nitrogen, 16.4% creatinine, 6.7% potassium and 6.9% sodium. Additionally, 0.13% of results were critically high (ionized calcium, potassium, and sodium) and 0.10% were critically low (potassium and ionized calcium). Hypokalemic patients were sent to the infusion therapy center for IV potassium. Patients experiencing hyperkalemia were retested and sent to the emergency department (ED). Hyponatremic and hypercalcemic patients were sent to the ED for further treatment. Abnormal (non-critical) results were reviewed by CP personnel to make treatment recommendations or medication adjustments. Conclusion i-STAT1 home testing performed by CP facilitated rapid therapeutic interventions and expedited decision-making. POC testing has increased the group’s efficiency—alleviating the need to transport specimens to the central laboratory and wait on test results before returning to the patient for treatment. Paramedicine emphasizes a proactive and preventative approach to medicine. We anticipate that this model of care and testing will expand to cover other chronic health conditions due to the program’s early success.
A-242 Validation of a Calculated Lipoprotein Insulin Resistance Score Using a Commercially Available NMR Spectrometer and Software
Abstract Background Insulin resistance leads to changes in lipid and lipoprotein metabolism prior to developing prediabetes, including an increase in the concentration of large very-low-density lipoprotein particles (LVLDL-p), the mean size of VLDL (VLDL-s), and the concentration of small low-density lipoprotein particles (sLDL-p). Conversely, there is a decrease in the concentration of large high-density lipoprotein particles (LHDL-p), mean size of HDL (HDL-s), and mean size of LDL (LDL-s). Clinically validated studies show that proton nuclear magnetic resonance (NMR) can measure these six parameters and derive a lipoprotein insulin resistance (LP-IR) score, ranging from 0 to 100, with higher scores indicating greater risk for insulin resistance. The reference method for calculating LP-IR relies on a proprietary NMR spectrometer, spectral deconvolution method, and algorithm. This study seeks to determine if lipoprotein subfraction parameters measured from a commercially available NMR system can produce LP-IR scores comparable to the reference method. Methods Serum lipoprotein NMR spectra were collected using a Bruker Ascend 600 MHz magnet, Bruker Avance NEO 500 spectrometer, and the Numares AXINON lipoFIT System to report the six LP-IR score parameters between January 2023 and January 2025 (Cohort A, n = 2,474). During the same period, LP-IR score and parameters were collected using the Vantera Clinical Analyzer (400 MHz) with the LipoProfile LP4 method (Cohort B, n = 2,959). Linear regression of decile-matched data for each parameter yielded adjustment equations to align lipoFIT values with the LipoProfile method. LP-IR scores were then calculated for both adjusted and unadjusted values using a previously published LP-IR scoring algorithm. Finally, LP-IR scores were compared for sera with measures from both instruments was (Cohort C, n = 108). Results The median concentrations of sLDL-p, LDL-s, VLDL-s, HDL-S matched between Cohort A and B (<1% difference). Significant differences were noted for LVLDL-p and LHDL-p, with percent differences of 21.5% and 23.5%, respectively. Despite closely matching medians, the distributions varied greatly, with a mean interquartile range (IQR) percent difference across measures of 31.2% (Table 1). After distribution matching, all parameter median and mean IQR percent differences fell to <5% and <10%, respectively, between Cohort A and Cohort B. In Cohort C the LP-IR score matched well (y=1.1x-15, r=0.92; 95%CI 0.88, 0.94). Following distribution matching adjustment of lipoFIT values for Cohort C, new calculated LP-IR scores matched with reduced bias (y=0.94x-1.2) while correlation was slightly reduced (r=0.88 [0.83, 0.92]). By comparison, adjustments made via scaling lipoFIT values proportionally by the ratio of the medians between Cohort A and Cohort B yielded calculated LP-IR scores in Cohort C that maintained a similar bias prior to adjustments (y=1.2x-21), highlighting the ability of distribution matching to reduce bias. Conclusion Adjustments to measured lipoprotein parameters from a commercially available NMR spectrometer can be achieved via distribution matching. These adjustments greatly reduce the bias between a commercially available method and algorithm compared to the reference method, allowing for wider adoption of LP-IR score reporting.
A-207 Investigating an Increase in Specimen Recollection Rates Due to Hemolysis After a Testing Location Change: The Impact of Specimen Type and Patient Population
Abstract Background The Oncology Department at our institution requested faster turn-around times (TAT) for chemistry testing. Prior to their request, serum separator tubes (SST) were collected and tested in our core laboratory. To accommodate the request, we added plasma total bilirubin and aspartate aminotransferase (AST) to our stat laboratory test menu with collection in plasma separator tubes (PST). Upon implementation of this testing change, we observed an increase in specimen recollection rates due to hemolysis. We systematically evaluated laboratory testing variables that could have contributed to the increase: pneumatic tube transport path, differences in hemolysis measurements between chemistry analyzer models, and specimen types. Previous studies have demonstrated that lithium heparin plasma specimens are more susceptible to hemolysis than serum. Likewise, patients undergoing chemotherapy or radiation therapy may have fragile red blood cell (RBC) membranes, further complicating the issue. Our study*s objective was to assess the impact of changing from SST to PST collections. We conducted a 3-month pilot study to determine if we could reduce our recollection rates by collecting/testing Rapid Serum Tube (RST), while maintaining plasma TAT. Methods We compared recollection rates for specimens collected from the oncology patients and tested in our core laboratory (SST, May-June 2021), stat laboratory (PST, September-November 2022), pilot period in stat lab (RST, January-March 2023), and post-pilot period in stat lab (PST, May-July 2023). Data were extracted from our laboratory information system and recollection rates were calculated using Tableau (Salesforce, Inc, San Francisco, CA). Analysis was performed in Excel (Microsoft, Redmond, WA) using Student’s t-test, with p < 0.05 defined as statistically significant. Results SST specimens collected from oncology patients and tested in the core lab (May-June 2021) resulted in a recollection rate of 0.17% (4/2341). PST specimens sent to the stat lab (Sept-Nov 2022) had an increased recollection rate of 0.90% (55/6129, p-value < 0.001). During the pilot period when RST tubes were used (Jan-Mar 2023), our recollection rate decreased to 0.19% (11/5801, p-value 0.014). After the pilot period ended and PST tubes were again utilized for testing (May-July 2023), the recollection rate again increased to 0.34% (22/6500, p-value 0.019). Conclusion Rapid TAT of laboratory results within specialized-care settings, such as a cancer treatment clinic, is necessary to provide patients with the most effective and personalized treatment regimens. Hemolysis presents a challenge as it generates an analytical issue with the release of contents from RBCs that may spuriously affect the concentration of the analyte being measured, delaying result reporting due to the need for specimen recollection. The data from our study highlight the utility of rapid serum tubes. Not only did they achieve stat TAT that was observed with the use of PST, but they also decreased specimen recollection rates that mirror the low rates observed with the use of SST. Thus, this technology may be an excellent replacement for standard SST when specimen integrity is critical to rapidly reporting accurate test results.
A-173 Evaluation of Plateletworks and TEG 6S Platelet Mapping: Performance Characteristics and Differentiation of Healthy Donors from Patients on Dual Antiplatelet Therapy
Abstract Background Platelet function tests (PFT) help assess bleeding risk and guide appropriate hemostatic measures in patients on antiplatelet therapy undergoing emergent surgical interventions. Light transmission aggregometry (LTA, BioData Corporation), the gold standard for assessing platelet function, cannot be performed rapidly enough for emergent interventions. In this study, we compared two PFT, Plateletworks (Helena Laboratories) and TEG 6S (TEG, Haemonetics) adenosine diphosphate-(ADP) and arachidonic acid (AA)-induced platelet function, evaluating analytical imprecision and their ability to differentiate healthy controls from patients with acute coronary syndrome (ACS) on dual antiplatelet therapy. Methods Fresh specimens were collected from healthy donors (HD, N=19) and a patient group (PG, N=17) on both aspirin and clopidogrel taken within 24 hours of procedure. Percent aggregation was measured according to manufacturers’ instructions using Plateletworks and TEG, utilizing both AA and ADP and compared to LTA performed on a PAP-8E Platelet Aggregometer. Two separate venipuncture collections from HD were used to obtain repeat measures of Plateletworks and TEG to assess variability in platelet function due to pre-analytical variables. Using a two-way nested ANOVA model on data from HD, we estimated variability between replicates of a single sample (intra-assay imprecision) and between blood draws within a single patient (inter-assay imprecision), reported as coefficient of variation (CV%). Platelet function results were summarized as median (interquartile range [IQR; 25th-75th percentiles]) and compared between groups using nonparametric Wilcoxon rank-sum test. Receiver operating characteristic (ROC) analysis (using duplicate means from first blood draw) was performed. Results Plateletworks AA % aggregation, medians (IQR) were 96.3 (95.3-97.1) for HD and 48.9 (46.8-54.8) for PG (p<0.001); ADP % aggregation were 97.0 (94.5-98.2) and 37.1 (28.0-53.0) for HD and PG, respectively (p<0.001). TEG AA % aggregation was 97.8 (94.4-99.8) for HD and 13.5 (7.9-26.8) for PG (p<0.001); ADP % aggregation was 98.3 (95.3-99.9) for HD and 83.3 (77.8-87.7) for TG (p<0.001). LTA AA % aggregation was 55.0 (44.0-64.8) for HD and 0.0 (0.0-1.5) for PG (p<0.001); ADP % aggregation of 59.0 (40.8-70.8) and 14.5 (4.5-19.5) for HD and PG, respectively (p<0.001). Intra- and inter-assay imprecision estimates (CV%), respectively, in HD were 1.4 and 5.1 for Plateletworks AA, 5.5 and 15.9 for Plateletworks ADP, 3.0 and 0.0 for TEG AA, and 2.6 and 0.8 for TEG ADP. Intra-assay precision estimates for LTA AA and LTA ADP were 19.3 and 8.2. In PG, intra-assay precision was estimated as 7.0 for Plateletworks AA, 9.6 for Plateletworks ADP, 61.3 for LTA AA, 11.9 for LTA ADP, 37.6 for TEG AA, and 4.1 for TEG ADP. In our limited data set, ROC analysis showed optimal cutpoints (sensitivity/specificity) for Plateletworks AA 65.5 (1.0/1.0) and ADP 84.5 (1.0/0.90), TEG AA 87.1 (1.0/1.0) and ADP 92.7 (1.0/1.0), and LTA AA 8.75 (0.94/1.0) and ADP 25.0 (0.82/0.90) Conclusion Plateletworks most effectively distinguished % aggregation between healthy donors and patients on dual antiplatelet therapy. TEG also differentiated the groups, but differences in median ADP-induced aggregation were smaller than with Plateletworks. Both AA and ADP assays on LTA showed more variability than either Plateletworks or TEG.
A-082 Prevalence of Vitamin D2 Toxicity in American Population
Abstract Background Vitamin D supplementation by human individuals has significantly increased in the world. In US the total stored 25-OH-Vitamin D3 and 25-OH-Vitamin D2 has significantly increased for both in summers and winters. Under sunlight exposure, 7 dehydrocholesterol is converted to Vitamin D3 and is endogenous source in mammals. However, most of the exogenous source for Vitamin D used to be Vitamin D2 which used to be extracted only from mushrooms but is now manufactured by supplement industry as well. In last decade most of the supplementation has been due to chemically synthesized Vitamin D3. Food is now supplemented by both D2 and D3. It is not clear what is the prevalence of D2 supplementation/consumption in American population. Competitive immunoassays do not consistently recover 25-OH-D2 compared to 25-OH-D3 and some antibodies used have variable or no cross reactivity with 25-OH-D2. LC-MS/MS method can easily distinguish the two and can help in providing the precise and accurate results for 25-OH-D2 and 25-OH-D3. Here we present what is the prevalence of Vitamin D2 consumption and toxicity in American population based on our LC-MS/MS methods. Methods The study measured vitamin 25-OH-D levels (total, D2, and D3) in 148,654 patients from Mayo Clinic as well as from other medical centers within the U.S. Patients age ranging from new-born babies to over 100 years, and represents Male, Female and Neutral genders. Samples were analyzed for 25-OH-Vitamin D by LC-MS/MS as published earlier. Unlike immunoassays, LC-MS/MS gave us separate results for 25-OH-D3 and 25-OH-D2 with 100 percent specificity. Results 25-OH-Vitamin D2 levels of greater than 10 was present in at least 10,358 and ranged from 10 to 205 ng/mL. Of 10,358, 51 percent had 20-50 ng/mL, 10 percent had 51-80 ng/mL, and 1.3 percent had >80 ng/mL, ranging from 81-205 ng/mL with a median of 92 ng/mL. Of the patients found at Total Vitamin D >80 ng/mL, toxic levels of both D2 and D3 were found more in females than males. There was no significant gender difference for Vitamin D3 consumption but for D2 consumption, mean and median levels were different in males and females. Conclusion Clinical lab testing should accurately measure both 25-OH-D3 and 25-OH-D2, otherwise the patient total Vitamin D values in circulation will be underestimated.
Adding employment status in the medical record demonstrates its importance as a social determinant of health
Abstract Objective To share findings of a quality improvement initiative to capture employment status in the electronic medical record (EMR) to mitigate the potential impact of work loss on the health of patients by utilizing the results to identify eligible individuals for resources to assist return-to-work efforts. Materials and Methods Patients self-identified employment status through a structured new social determinants of health (SDOH) question within the EMR. An electronic outreach campaign was developed to provide information via the patient portal detailing services within healthcare and the community that could benefit the patients. Results Over the course of 12 months, 2059 patients were identified from the employment SDOH question. Resources to support stay at work and return to work efforts were provided to patients through an automated electronic portal campaign with 87% of patients reading the message and 7% engaging with a healthcare return to work case manager. Discussion Loss of employment has detrimental impacts on individual and population health. Most EMRs do not capture information on employment status. Adding this simple question identified individuals with potential gaps in SDOH, and in this case allowed specific resources to be shared with patients with an illness or injury that was acutely impacting work. Conclusion Medical center decision makers and EMR programmers should consider adding employment status as a social determinant of health.