Kurak, Julia

Mayo Clinic

Mayo Clinic

Citations 1

A-242 Validation of a Calculated Lipoprotein Insulin Resistance Score Using a Commercially Available NMR Spectrometer and Software
Hornseth, Jean M, Kurak, Julia, Vasile, Vlad C. , Jaffe, Allan S. , Meeusen, Jeff W., Miller, Joshua R. , Donato, Leslie J. , Jaffe, Allan S. , Meeusen, Jeffrey W.

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.235 Get It

Abstract Background Insulin resistance leads to changes in lipid and lipoprotein metabolism prior to developing prediabetes, including an increase in the concentration of large very-low-density lipoprotein particles (LVLDL-p), the mean size of VLDL (VLDL-s), and the concentration of small low-density lipoprotein particles (sLDL-p). Conversely, there is a decrease in the concentration of large high-density lipoprotein particles (LHDL-p), mean size of HDL (HDL-s), and mean size of LDL (LDL-s). Clinically validated studies show that proton nuclear magnetic resonance (NMR) can measure these six parameters and derive a lipoprotein insulin resistance (LP-IR) score, ranging from 0 to 100, with higher scores indicating greater risk for insulin resistance. The reference method for calculating LP-IR relies on a proprietary NMR spectrometer, spectral deconvolution method, and algorithm. This study seeks to determine if lipoprotein subfraction parameters measured from a commercially available NMR system can produce LP-IR scores comparable to the reference method. Methods Serum lipoprotein NMR spectra were collected using a Bruker Ascend 600 MHz magnet, Bruker Avance NEO 500 spectrometer, and the Numares AXINON lipoFIT System to report the six LP-IR score parameters between January 2023 and January 2025 (Cohort A, n = 2,474). During the same period, LP-IR score and parameters were collected using the Vantera Clinical Analyzer (400 MHz) with the LipoProfile LP4 method (Cohort B, n = 2,959). Linear regression of decile-matched data for each parameter yielded adjustment equations to align lipoFIT values with the LipoProfile method. LP-IR scores were then calculated for both adjusted and unadjusted values using a previously published LP-IR scoring algorithm. Finally, LP-IR scores were compared for sera with measures from both instruments was (Cohort C, n = 108). Results The median concentrations of sLDL-p, LDL-s, VLDL-s, HDL-S matched between Cohort A and B (<1% difference). Significant differences were noted for LVLDL-p and LHDL-p, with percent differences of 21.5% and 23.5%, respectively. Despite closely matching medians, the distributions varied greatly, with a mean interquartile range (IQR) percent difference across measures of 31.2% (Table 1). After distribution matching, all parameter median and mean IQR percent differences fell to <5% and <10%, respectively, between Cohort A and Cohort B. In Cohort C the LP-IR score matched well (y=1.1x-15, r=0.92; 95%CI 0.88, 0.94). Following distribution matching adjustment of lipoFIT values for Cohort C, new calculated LP-IR scores matched with reduced bias (y=0.94x-1.2) while correlation was slightly reduced (r=0.88 [0.83, 0.92]). By comparison, adjustments made via scaling lipoFIT values proportionally by the ratio of the medians between Cohort A and Cohort B yielded calculated LP-IR scores in Cohort C that maintained a similar bias prior to adjustments (y=1.2x-21), highlighting the ability of distribution matching to reduce bias. Conclusion Adjustments to measured lipoprotein parameters from a commercially available NMR spectrometer can be achieved via distribution matching. These adjustments greatly reduce the bias between a commercially available method and algorithm compared to the reference method, allowing for wider adoption of LP-IR score reporting.