Citations

Mayo Clinic

Showing 10 of 108599 citations.

Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Left Main and Multivessel Coronary Artery Disease
Stone, Gregg W. , Bhatt, Deepak L. , Gersh, Bernard J. , Bhatt, Deepak L

Circulation | February 27, 2017 | Volume: 135 | Issue: 9 | Pages: 819-821

10.1161/circulationaha.116.025263 | PMID 28242636 Get It

Implementation and evaluation of a protocol management system for automated review of CT protocols
Grimes, Joshua, Vrieze, Thomas J., McCollough, C, Leng, Shuai , Zhang, Yi

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 17 | Issue: 5 | Pages: 523-533

10.1120/jacmp.v17i5.6164 | PMID 27685112 Get It

Protocol review is important to decrease the risk of patient injury and increase the consistency of CT image quality. A large volume of CT protocols makes manual review labor‐intensive, error‐prone, and costly. To address these challenges, we have developed a software system for automatically managing and monitoring CT protocols on a frequent basis. This article describes our experiences in the implementation and evaluation of this protocol monitoring system. In particular, we discuss various strategies for addressing each of the steps in our protocol‐monitoring workflow, which are: maintaining an accurate set of master protocols, retrieving protocols from the scanners, comparing scanner protocols to master protocols, reviewing flagged differences between the scanner and master protocols, and updating the scanner and/or master protocols. In our initial evaluation focusing only on abdomen and pelvis protocols, we detected 309 modified protocols in a 24‐week trial period. About one‐quarter of these modified protocols were determined to contain inappropriate (i.e., erroneous) protocol parameter modifications that needed to be corrected on the scanner. The most frequently affected parameter was the series description, which was inappropriately modified 47 times. Two inappropriate modifications were made to the tube current, which is particularly important to flag as this parameter impacts both radiation dose and image quality. The CT protocol changes detected in this work provide strong motivation for the use of an automated CT protocol quality control system to ensure protocol accuracy and consistency.PACS number(s): 87.57.Q‐
A comparative study of automatic image segmentation algorithms for target tracking in MR‐IGRT
Kawrakow, I., Olsen, Jeff, Parikh, Parag J., Wooten, O., Du, D. , Mutic, Sasa , Hu, Yanle , Feng, Yuan , Noel, Camille E.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 17 | Issue: 2 | Pages: 441-460

10.1120/jacmp.v17i2.5820 | PMID 27074465 Get It

On‐board magnetic resonance (MR) image guidance during radiation therapy offers the potential for more accurate treatment delivery. To utilize the real‐time image information, a crucial prerequisite is the ability to successfully segment and track regions of interest (ROI). The purpose of this work is to evaluate the performance of different segmentation algorithms using motion images (4 frames per second) acquired using a MR image‐guided radiotherapy (MR‐IGRT) system. Manual contours of the kidney, bladder, duodenum, and a liver tumor by an experienced radiation oncologist were used as the ground truth for performance evaluation. Besides the manual segmentation, images were automatically segmented using thresholding, fuzzy k‐means (FKM), k‐harmonic means (KHM), and reaction‐diffusion level set evolution (RD‐LSE) algorithms, as well as the tissue tracking algorithm provided by the ViewRay treatment planning and delivery system (VR‐TPDS). The performance of the five algorithms was evaluated quantitatively by comparing with the manual segmentation using the Dice coefficient and target registration error (TRE) measured as the distance between the centroid of the manual ROI and the centroid of the automatically segmented ROI. All methods were able to successfully segment the bladder and the kidney, but only FKM, KHM, and VR‐TPDS were able to segment the liver tumor and the duodenum. The performance of the thresholding, FKM, KHM, and RD‐LSE algorithms degraded as the local image contrast decreased, whereas the performance of the VP‐TPDS method was nearly independent of local image contrast due to the reference registration algorithm. For segmenting high‐contrast images (i.e., kidney), the thresholding method provided the best speed ( ) with a satisfying accuracy ( ). When the image contrast was low, the VR‐TPDS method had the best automatic contour. Results suggest an image quality determination procedure before segmentation and a combination of different methods for optimal segmentation with the on‐board MR‐IGRT system. PACS number(s): 87.57.nm, 87.57.N‐, 87.61.Tg
Technical Note: Insertion of digital lesions in the projection domain for dual‐source, dual‐energy CT
Ferrero, Andrea , Chen, Baiyu , Li, Zhoubo , Yu, Lifeng , McCollough, Cynthia, Yu, Lifeng , McCollough, Cynthia H.

Medical Physics | February 27, 2017 | Volume: 44 | Issue: 5 | Pages: 1655-1660

10.1002/mp.12185 | PMID 28241103 Get It

PurposeTo compare algorithms performing material decomposition and classification in dual‐energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual‐source, dual‐energy CT system.MethodsA model that takes into account beam‐hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x‐ray energy spectra, the patient/phantom attenuation, and the x‐ray detector energy response. The beam‐hardening model was validated on samples of iodine (I) and calcium (Ca) for a second‐generation dual‐source, dual‐energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x‐ray energy spectra using the developed beam‐hardening model. Each digital stone was inserted in the dual‐energy projection data of a water phantom scanned on a dual‐source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual‐energy data was validated by comparing CT number accuracy and high‐contrast resolution of simulated dual‐energy CT data of the ACR phantom with experimentally acquired data.ResultsThe beam‐hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the literature. A sample application of the proposed tool was also demonstrated.ConclusionA framework was developed and validated for the creation of digital objects of known mineral composition, and for inserting the digital objects into projection data from a commercial dual‐source, dual‐energy CT scanner. Among other applications, it will allow a systematic investigation of the impact of scan and reconstruction parameters on kidney stone dual‐energy properties under rigorously controlled conditions.
Association Between Telomere Length and Risk of Cancer and Non-Neoplastic Diseases
Haycock, Philip , Burgess, Stephen , Nounu, Aayah , Zheng, Jie , Okoli, George N. , Wade, Kaitlin H. , Timpson, Nicholas J. , Evans, David M. , Willeit, Peter , Aviv, Abraham , Gaunt, Tom R. , Hemani, Gibran , Mangino, Massimo , Ellis, Hayley, Kurian, Kathreena M. , Pooley, Karen A. , Eeles, Rosalind A. , Lee, Jeffrey E. , Fang, Shenying , Chen, Wei V., Law, Matthew H. , Bowdler, Lisa, Iles, Mark M. , Worrall, Bradford B. , Markus, Hugh S. , Hung, Rayjean J., Amos, Chris, Thompson, Deborah J. , O’Mara, Tracy A. , Wolpin, Brian M. , Ámundadóttir, Laufey T. , Trichopoulou, Antonia , Onland‐Moret, N. Charlotte , Lund, Eiliv , Canzian, Federico , Severi, Gianluca , Overvad, Kim , Gunter, Marc J. , ­Tumino, ­Rosario , Svenson, Ulrika, Rij, André van, Baas, Annette F., Bown, Matthew J. , Samani, Nilesh J. , t’Hof, Femke N.G. van, Tromp, Gerard , Jones, Gregory T. , Kuivaniemi, Helena , Elmore, James R. , Johansson, Mattias , McKay, James , Scélo, Ghislaine , Carreras‐Torres, Robert , Gaborieau, Valérie , Brennan, Paul , Bracci, Paige M. , Olson, Sara H. , Gallinger, Steven , Li, Donghui , Petersen, Gloria M. , Han, Jiali , Abnet, Christian C. , Freedman, Neal D. , Aben, Katja K.H. , Kiemeney, Lambertus A. , Vermeulen, Sita H. , Walsh, Kyle M. , Wrensch, Margaret , Rice, Terri, Turnbull, Clare , Litchfield, Kevin , Paternoster, Lavinia , Standl, Marie , Mijatovic, Vladan, Sapkota, Yadav , Zondervan, Krina T. , Nyholt, Dale R. , Heel, David A. van , Arking, Dan E. , Ashar, Foram N., Sotoodehnia, Nona, Woo, Daniel , Comeau, Mary E. , Brown, W. Mark , Silverman, Edwin K. , Hokanson, John E. , Hui, Jennie , Thompson, Philip J. , Morrison, Alanna C. , Smith, Nicholas L. , Christiano, Angela M. , Petukhova, Lynn , Betz, Regina C. , Zhang, Xuejun, Zhu, Caihong, Langefeld, Carl D. , Thompson, Susan D. , Wang, Feijie , Fingerlin, Tasha E. , Rotter, Jerome I. , Cotch, Mary Frances , Jensen, Richard A., Munz, Matthias , Dommisch, Henrik , Schäefer, Arne S. , Ollila, Hanna M. , Hillary, Ryan P. , Zeng, Chenjie , Zheng, Wei , Shu, Xiao-Ou , Reis, André , Uebe, Steffen , Hüffmeier, Ulrike , Kawamura, Yoshiya, Otowa, Takeshi , Sasaki, Tsukasa, Dávila, Sonia , Siminovitch, Katherine A. , Bei, Jin‐Xin , Zeng, Yi‐Xin , Chen, Bowang , Franke, Andre, Fischer, Annegret, Ellinghaus, David , Flores, Carlos , Noth, Imre , Ma, Shwu‐Fan , Foo, Jia Nee , Liu, Jianjun , Cox, David G. , Delattre, Olivier , Mirabeau, Olivier , Skibola, Christine F., Tang, Clara Sze-Man , Garcia-Barceló, Mercè, Su, Wen-Hui , Chang, Yu‐Sun , Wade, Tracey , Lee, Chaeyoung , Kubo, Michiaki , Cha, Pei-Chieng , Nakamura, Yusuke, Levy, Daniel , Hunt, S. E., Spector, Tim D. , Soranzo, Nicole , Barr, R. Graham, Kahali, Bratati , Speliotes, Elizabeth K. , Yerges-Armstrong, Laura M. , Cheng, Ching‐Yu , Wong, Tien Yin , Fogh, Isabella , Powell, John , Rice, Kenneth , Relton, Caroline L. , Martin, Richard M. , Smith, George Davey , Hung, Rayjean J. , Bowden, Jack , Yang, Qiong , Spurdle, Amanda B. , Stolzenberg‐Solomon, Rachael Z. , Duell, Eric J. , Neale, Rachel Ε. , Risch, Harvey A. , Klein, Alison P. , Taylor, Philip R. , Maris, John M. , Wiencke, John K. , Abecasis, Gonçalo R. , SanGiovanni, John Paul , Li, Yong , Low, Siew‐Kee , Montgomery, Grant W. , Hunt, Karen A. , Rosand, Jonathan M. , Cho, Michael H. , Ferreira, Manuel A. R. , Felix, Janine F. , Fan, Xing Hua , Xu, Lin , Schwartz, David A. , Han, Fang , Albagha, Omar , Ralston, Stuart H. , Sasaki, Tsukasa, Hibberd, Martin Lloyd , Xie, Gang , Försti, Asta , Landi, Stefano , Ellinghaus, David , Kim, Jong‐Won , Chang, Kai‐Ping , Martin, Nicholas G. , Gordon, Scott D. , Kimura, Masayuki , Hwang, Shih‐Jen , Manichaikul, Ani , Barr, R. Graham, Jonas, Jost B , Lin, Kuang , Amundadottir, Laufey , Kiemeney, Lambertus A , Eeles, Rosalind A , van Heel, David A , Gunter, Marc J , Canzian, Federico , Hung, Rayjean J , O'Mara, Tracy A , Abnet, Christian C , Haycock, Philip , Tumino, Rosario , Han, Jiali , Martin, Richard M , Severi, Gianluca , Reis, André , Zheng, Wei , Rotter, Jerome I , Carreras-Torres, Robert , Law, Matthew H , Davey Smith, George , Johansson, Mattias , Iles, Mark M , Morrison, Alanna C , Rice, Ken , Freedman, Neal D , Foo, Jia Nee , Levy, Daniel , Rice, Kenneth , Sapkota, Yadav , Wong, Tien Y , Liu, Jing

JAMA Oncology | February 27, 2017 | Volume: 3 | Issue: 5 | Pages: 636

10.1001/jamaoncol.2016.5945 | PMID 28241208 Get It

Automatic polyp detection in colonoscopy videos
Yuan, Zijie, Izadyyazdanabadi, Mohammadhassan , Mokkapati, Divya, Panvalkar, Rujuta, Shin, J. , Tajbakhsh, Nima , Gurudu, Suryakanth, Liang, Jianming , Shin, Jae Y.

SPIE Proceedings | February 27, 2017 | Volume: 10133 | Issue: No issue available | Pages: 101332K

10.1117/12.2254671 Get It

Desiderosmia (olfactory craving): A novel symptom associated with iron deficiency anemia
Hansen, Bryar R. , Bottner, Wayne A., Ravindran, Aishwarya , DeJesus, Ramona S. , Go, Ronald S. , DeJesus, Ramona, Go, Ronald S , Ravindran, Aishwarya

American Journal of Hematology | February 27, 2017 | Volume: 92 | Issue: 6 | Pages: No page available

10.1002/ajh.24706 | PMID 28240803 Get It

Immunoglobulin Light Chains Form an Extensive and Highly Ordered Fibril Involving the N- and C-Termini
Piehl, Dennis W. , Blancas‐Mejía, Luis M. , Wall, Jonathan S. , Kennel, Stephen J., Ramı́rez-Alvarado, Marina , Rienstra, Chad M. , Ramirez-Alvarado, Marina

ACS Omega | February 27, 2017 | Volume: 2 | Issue: 2 | Pages: 712-720

10.1021/acsomega.6b00494 | PMID 28261692 Get It

Protein Nutrition and Malnutrition in CKD and ESRD
Zha, Yan , Qian, Qi

Nutrients | February 27, 2017 | Volume: 9 | Issue: 3 | Pages: 208

10.3390/nu9030208 | PMID 28264439 Get It

Elevated protein catabolism and protein malnutrition are common in patients with chronic kidney disease (CKD) and end‐stage renal disease (ESRD). The underlying etiology includes, but is not limited to, metabolic acidosis intestinal dysbiosis; systemic inflammation with activation of complements, endothelin‐1 and renin‐angiotensin‐aldosterone (RAAS) axis; anabolic hormone resistance; energy expenditure elevation; and uremic toxin accumulation. All of these derangements can further worsen kidney function, leading to poor patient outcomes. Many of these CKD‐related derangements can be prevented and substantially reversed, representing an area of great potential to improve CKD and ESRD care. This review integrates known information and recent advances in the area of protein nutrition and malnutrition in CKD and ESRD. Management recommendations are summarized. Thorough understanding the pathogenesis and etiology of protein malnutrition in CKD and ESRD patients will undoubtedly facilitate the design and development of more effective strategies to optimize protein nutrition and improve outcomes.
A multicenter study to define sarcopenia in patients with end‐stage liver disease
Carey, Elizabeth J. , Wang, Connie W. , Lobach, Iryna , Montaño‐Loza, Aldo J. , Dunn, Michael A. , Wang, Connie W , Lai, Jennifer C. , Dasarathy, Srinivasan , Montano-Loza, Aldo J

Liver Transplantation | February 27, 2017 | Volume: 23 | Issue: 5 | Pages: 625-633

10.1002/lt.24750 | PMID 28240805 Get It

Sarcopenia is associated with increased wait‐list mortality, but a standard definition is lacking. In this retrospective study, we sought to determine the optimal definition of sarcopenia in end‐stage liver disease (ESLD) patients awaiting liver transplantation (LT). Included were 396 patients newly listed for LT in 2012 at 5 North American transplant centers. All computed tomography scans were read by 2 individuals with interobserver correlation of 98%. Using image analysis software, the total cross‐sectional area (cm 2 ) of abdominal skeletal muscle at the third lumbar vertebra was measured. The skeletal muscle index (SMI), which normalizes muscle area to patient height, was then calculated. The primary outcome was wait‐list mortality, defined as death on the waiting list or removal from the waiting list for reasons of clinical deterioration. Sex‐specific potential cutoff values to define sarcopenia were determined with a grid search guided by log‐rank test statistics. Optimal search methods identified potential cutoffs to detect survival differences between groups. The overall median SMI was 47.6 cm 2 /m 2 : 50.0 in men and 42.0 in women. At a median of 8.8 months follow‐up, mortality was 25% in men and 36% in women. Patients who died had lower SMI than those who survived (45.6 versus 48.5 cm 2 /m 2 ; P < 0.001), and SMI was associated with wait‐list mortality (hazard ratio, 0.95; P < 0.001). Optimal search method yielded SMI cutoffs of 50 cm 2 /m 2 for men and 39 cm 2 /m 2 for women; these cutoff values best combined statistical significance with a sufficient number of events to detect survival differences between groups. In conclusion, we recommend that an SMI < 50 cm 2 /m 2 for men and < 39 cm 2 /m 2 for women be used to define sarcopenia in patients with ESLD awaiting LT. Liver Transplantation 23 625–633 2017 AASLD .