Neurodegenerative diseases such as Alzheimer's disease (AD) and Parkinson's disease (PD) present a major health burden to society. Changes in brain structure and cognition are generally only observed at the late stage of the disease. Although advanced magnetic resonance imaging (MRI) techniques such as diffusion imaging may allow identification of biomarkers at earlier stages of neurodegeneration, early diagnosis is still challenging. Magnetic resonance elastography (MRE) is a noninvasive MRI technique for studying the mechanical properties of tissues by measuring the wave propagation induced in the tissues using a purpose‐built actuator. Here, we present a systematic review of preclinical and clinical studies in which MRE has been applied to study neurodegenerative diseases. Actuator systems for data acquisition, inversion algorithms for data analysis, and sample demographics are described and tissue stiffness measures obtained for the whole brain and internal structures are summarized. A total of six animal studies and eight human studies have been published. The animal studies refer to 123 experimental animals (68 AD and 55 PD) and 121 wild‐type animals, while the human studies refer to 142 patients with neurodegenerative disease (including 56 AD and 17 PD) and 166 controls. The animal studies are consistent in the reporting of decreased stiffness of the hippocampal region in AD mice. However, in terms of disease progression, although consistent decreases in either storage modulus or shear modulus magnitude are reported for whole brain, there is variation in the results reported for the hippocampal region. The clinical studies are consistent in reports of a significant decrease in either whole brain storage modulus or shear modulus magnitude, in both AD and PD and with different brain structures affected in different neurodegenerative diseases. MRE studies of neurodegenerative diseases are still in their infancy, and in future it will be interesting to investigate potential relationships between brain mechanical properties and clinical measures, which may help elucidate the mechanisms underlying onset and progression of neurodegenerative diseases.Evidence Level1.Technical EfficacyStage 2.
A preliminary study of the local biomechanical environment of liver tumors in vivo
PurposeBiomechanical properties can be used as biomarkers to diagnose tumors, monitor tumor development, and evaluate treatment efficacy. The purpose of this preliminary study is to characterize the biomechanical environment of two typical liver tumors, hemangiomas (HEMs) and hepatocellular carcinomas (HCCs), and to investigate the potential of using strain metrics as biomarkers for tumor diagnosis, based on a limited clinical dataset.MethodsMagnetic resonance (MR) tagging was used to quantify the motion and deformation of the two types of liver tumors. Displacements of the tumors arising from a heartbeat were measured over one cardiac cycle. Local biomechanical conditions of the tumors were characterized by estimating two principal strains (ε1 and ε2) and an octahedral shear strain (εsoct) of the tumor and its peripheral region. Biomechanical conditions of the tumors were compared with those of the arbitrarily selected regions from healthy volunteers.ResultsWe observed that the HCCs had significantly smaller strain values compared to their peripheral tissues. However, the HEMs did not have significantly different strains from those of the peripheral tissues, and were similar to healthy liver regions. The sensitivity of using ε1, ε2, and εsoct to diagnose HCC were all 1, while the sensitivity of using ε1, ε2, and εsoct to diagnose HEM were 0.67, 0.17, and 0.67, respectively.ConclusionsLagrangian strain metrics provide insight into the biomechanical conditions of certain liver tumors in the human body and may provide another perspective for tumor characterization and diagnosis.
An adaptive Fuzzy C-means method utilizing neighboring information for breast tumor segmentation in ultrasound images
On‐board magnetic resonance (MR) image guidance during radiation therapy offers the potential for more accurate treatment delivery. To utilize the real‐time image information, a crucial prerequisite is the ability to successfully segment and track regions of interest (ROI). The purpose of this work is to evaluate the performance of different segmentation algorithms using motion images (4 frames per second) acquired using a MR image‐guided radiotherapy (MR‐IGRT) system. Manual contours of the kidney, bladder, duodenum, and a liver tumor by an experienced radiation oncologist were used as the ground truth for performance evaluation. Besides the manual segmentation, images were automatically segmented using thresholding, fuzzy k‐means (FKM), k‐harmonic means (KHM), and reaction‐diffusion level set evolution (RD‐LSE) algorithms, as well as the tissue tracking algorithm provided by the ViewRay treatment planning and delivery system (VR‐TPDS). The performance of the five algorithms was evaluated quantitatively by comparing with the manual segmentation using the Dice coefficient and target registration error (TRE) measured as the distance between the centroid of the manual ROI and the centroid of the automatically segmented ROI. All methods were able to successfully segment the bladder and the kidney, but only FKM, KHM, and VR‐TPDS were able to segment the liver tumor and the duodenum. The performance of the thresholding, FKM, KHM, and RD‐LSE algorithms degraded as the local image contrast decreased, whereas the performance of the VP‐TPDS method was nearly independent of local image contrast due to the reference registration algorithm. For segmenting high‐contrast images (i.e., kidney), the thresholding method provided the best speed ( ) with a satisfying accuracy ( ). When the image contrast was low, the VR‐TPDS method had the best automatic contour. Results suggest an image quality determination procedure before segmentation and a combination of different methods for optimal segmentation with the on‐board MR‐IGRT system. PACS number(s): 87.57.nm, 87.57.N‐, 87.61.Tg