Citations

Mayo Clinic

Showing 10 of 108599 citations.

An improvement in IMRT QA results and beam matching in linacs using statistical process control
Gagneur, Justin D., Ezzell, Gary A.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 190-195

10.1120/jacmp.v15i5.4927 | PMID 25207579 Get It

The purpose of this study is to apply the principles of statistical process control (SPC) in the context of patient specific intensity‐modulated radiation therapy (IMRT) QA to set clinic‐specific action limits and evaluate the impact of changes to the multileaf collimator (MLC) calibrations on IMRT QA results. Ten months of IMRT QA data with 247 patient QAs collected on three beam‐matched linacs were retrospectively analyzed with a focus on the gamma pass rate (GPR) and the average ratio between the measured and planned doses. Initial control charts and action limits were calculated. Based on this data, changes were made to the leaf gap parameter for the MLCs to improve the consistency between linacs. This leaf gap parameter is tested monthly using a MLC sweep test. A follow‐up dataset with 424 unique QAs were used to evaluate the impact of the leaf gap parameter change. The initial data average GPR was 98.6% with an SPC action limit of 93.7%. The average ratio of doses was 1.003, with an upper action limit of 1.017 and a lower action limit of 0.989. The sweep test results for the linacs were , and from nominal. After the adjustment of the leaf gap parameter, all sweep test results were within 0.4% of nominal. Subsequently, the average GPR was 99.4% with an SPC action limit of 97.3%. The average ratio of doses was 0.997 with an upper action limit of 1.011 and a lower action limit of 0.981. Applying the principles of SPC to IMRT QA allowed small differences between closely matched linacs to be identified and reduced. Ongoing analysis will monitor the process and be used to refine the clinical action limits for IMRT QA.PACS number: 87.55.Qr
Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer
Liu, Wei , Matney, J, Zhang, Xiaodong , Li, Yupeng , Zhu, Ronald X., Li, Heng , Park, Peter, Liao, Zhongxing , Chang, Joe Y. , Li, Yupeng, Liu, Wei

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 47-56

10.1120/jacmp.v15i5.4810 | PMID 25207565 Get It

The objective of this study was to evaluate and understand the systematic error between the planned three‐dimensional (3D) dose and the delivered dose to patient in scanning beam proton therapy for lung tumors. Single‐field and multifield optimized scanning beam proton therapy plans were generated for ten patients with stage II‐III lung cancer with a mix of tumor motion and size. 3D doses in CT datasets for different respiratory phases and the time‐weighted average CT, as well as the four‐dimensional (4D) doses were computed for both plans. The 3D and 4D dose differences for the targets and different organs at risk were compared using dose‐volume histogram (DVH) and voxel‐based techniques, and correlated with the extent of tumor motion. The gross tumor volume (GTV) dose was maintained in all 3D and 4D doses, using the internal GTV override technique. The DVH and voxel‐based techniques are highly correlated. The mean dose error and the standard deviation of dose error for all target volumes were both less than 1.5% for all but one patient. However, the point dose difference between the 3D and 4D doses was up to 6% for the GTV and greater than 10% for the clinical and planning target volumes. Changes in the 4D and 3D doses were not correlated with tumor motion. The planning technique (single‐field or multifield optimized) did not affect the observed systematic error. In conclusion, the dose error in 3D dose calculation varies from patient to patient and does not correlate with lung tumor motion. Therefore, patient‐specific evaluation of the 4D dose is important for scanning beam proton therapy for lung tumors.PACS number: 87.55.D
A simplified methodology to produce Monte Carlo dose distributions in proton therapy
Beltran, Chris , Jia, Yingcui, Slopsema, R , Yeung, Daniel , Li, Zuofeng , Beltran, Chris J

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 4 | Pages: 2-10

10.1120/jacmp.v15i4.4413 | PMID 25207391 Get It

The purpose of this study was to develop a simplified methodology that will produce Monte Carlo (MC) dose distribution for proton therapy which can be used as a clinical aid in determining the adequacy of proton plans produced from the treatment planning system (TPS). The Geant4 Monte Carlo toolkit was used for all simulations. The geometry of the double scatter nozzle in the simulation was a simplification of the treatment nozzle. The proton source was modeled as discrete energy layers, each with a unique energy distribution and weighting factor. The simplified MC system was designed to give the same dose distribution as the measured data used to commission the TPS. After the simplified MC system was finalized, a series of verification comparisons were made between it, measurements, and the clinically used TPS. Comparisons included the lateral profile of a stair‐shaped compensator that simulated a sharp lateral heterogeneity and depth‐dose measurements through heterogeneous materials. The simplified MC system matched measurements to within 2% or 2 mm for all commissioning data under investigation; moreover, the distal edge and lateral penumbra was within 1 mm of the measurements. The simplified MC system was able to better reproduce the measured profiles for a stair‐shaped compensator than the TPS. Both MC and TPS matched the measured depth dose through heterogeneous materials to within 2% or 2 mm. The simplified MC system was straightforward to implement, and produced accurate results when compared to measurements. Therefore, it holds promise as a clinically useful methodology to validate the relative dose distribution of patient treatment plans produced by the treatment planning systems.PACS number: 87.55.K‐, 87.55.ne
Optical Coherence Tomography for the Noninvasive Detection of Elevated Intracranial Pressure
Brodsky, Michael C., Chen, John J. , Wetjen, Nicholas M. , Chen, John J

JAMA Ophthalmology | February 27, 2017 | Volume: 135 | Issue: 4 | Pages: 329

10.1001/jamaophthalmol.2017.0021 | PMID 28241152 Get It

Adjusted Analyses in Studies Addressing Therapy and Harm
Agoritsas, Thomas , Merglen, Arnaud , Shah, Nilay D. , O’Donnell, Martin , Guyatt, Gordon

JAMA | February 27, 2017 | Volume: 317 | Issue: 7 | Pages: 748

10.1001/jama.2016.20029 | PMID 28241362 Get It

Implementation of an improved dose‐per‐MU model for double‐scattered proton beams to address interbeamline modulation width variability
Lin, Liyong , Shen, Jiajian , Ainsley, C., Solberg, Timothy D. , McDonough, James E., Shen, Jiajian , Lin, Liyong

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 3 | Pages: 297-306

10.1120/jacmp.v15i3.4748 | PMID 24892352 Get It

Because treatment planning systems (TPSs) generally do not provide monitor units (MUs) for double‐scattered proton plans, models to predict MUs as a function of the range and the nominal modulation width requested of the beam delivery system, such as the one developed by the MGH group, have been proposed. For a given nominal modulation width, however, the measured modulation width depends on the accuracy of the vendor's calibration process and may differ from this nominal value, and also from one beamline to the next. Although such a difference can be replicated in our TPS, the output dependence on range and modulation width for each beam option or suboption has to be modeled separately for each beamline in order to achieve maximal 3% inaccuracy. As a consequence, the MGH output model may not be directly transferable. This work, therefore, serves to extend the model to more general clinic situations. In this paper, a parameterized linear‐quadratic transformation is introduced to convert the nominal modulation width to the measured modulation width for each beam option or suboption on a per‐beamline basis. Fit parameters are derived for each beamline from measurements of 60 reference beams spanning the minimum and maximum ranges, and modulation widths from 2 cm to full range per option or suboption. Using the modeled modulation width, we extract the MGH parameters for the output dependence on range and modulation width. Our method has been tested with 1784 patient‐specific fields delivered across three different beamlines at our facility. For these fields, all measured outputs fall within 3%, and 64.4% fall within 1%, of our model. Using a parameterized linear‐quadratic modulation width, MU calculation models can be established on a per‐beamline basis for each double scattering beam option or suboption.PACS number: 87.53.Qc
Lung tumor motion change during stereotactic body radiotherapy (SBRT): an evaluation using MRI
Saito, Anneyuko I. , Olivier, Kenneth R. , Li, Jonathan G. , Liu, Chihray, Newlin, Heather E., Schmalfuss, Ilona M. , Kyogoku, Shinsuke , Dempsey, James F.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 3 | Pages: 25-31

10.1120/jacmp.v15i3.4434 | PMID 24892328 Get It

The purpose of this study is to investigate changes in lung tumor internal target volume during stereotactic body radiotherapy treatment (SBRT) using magnetic resonance imaging (MRI). Ten lung cancer patients (13 tumors) undergoing SBRT (48 Gy over four consecutive days) were evaluated. Each patient underwent three lung MRI evaluations: before SBRT (MRI‐1), after fraction 3 of SBRT (MRI‐3), and three months after completion of SBRT (MRI‐3m). Each MRI consisted of T1‐weighted images in axial plane through the entire lung. A cone‐beam CT (CBCT) was taken before each fraction. On MRI and CBCT taken before fractions 1 and 3, gross tumor volume (GTV) was contoured and differences between the two volumes were compared. Median tumor size on CBCT before fractions 1 (CBCT‐1) and 3 (CBCT‐3) was 8.68 and 11.10 cm3, respectively. In 12 tumors, the GTV was larger on CBCT‐3 compared to CBCT‐1 (median enlargement, 1.56 cm3). Median tumor size on MRI‐1, MRI‐3, and MRI‐3m was 7.91, 11.60, and 3.33 cm3, respectively. In all patients, the GTV was larger on MRI‐3 compared to MRI‐1 (median enlargement, 1.54 cm3). In all patients, GTV was smaller on MRI‐3m compared to MRI‐1 (median shrinkage, 5.44 cm3). On CBCT and MRI, all patients showed enlargement of the GTV during the treatment week of SBRT, except for one patient who showed minimal shrinkage (0.86 cm3). Changes in tumor volume are unpredictable; therefore, motion and breathing must be taken into account during treatment planning, and image‐guided methods should be used, when treating with large fraction sizes.PACS number: 87.53.Ly
Comparing Gamma Knife and CyberKnife in patients with brain metastases
Jang, Sunyoung, Curran, Bruce, Pyakuryal, Anil, Sternick, Edward S., Sio, Terence T. , Jang, Sunyoung, Lee, Sung‐Woo

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 1 | Pages: 14-26

10.1120/jacmp.v15i1.4095 | PMID 24423830 Get It

The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the difference between V12 and tumor volume (V12net), homogeneity index (HI), and gradient indices (GI25, GI50) were calculated. Peripheral dose falloff and three conformity indices were compared. The median tumor volume was 2.50 cm3 (range, 0. 044‐19.9). A median dose of 18 Gy (range, 15‐22) was prescribed. In GK and CK plans, doses were prescribed to the 40‐50% and 77‐92% isodose lines, respectively. Comparing GK to CK, the respective parametric values were: minimum dose ( vs. , ); mean dose ( vs., ); maximum dose ( vs., ); and HI ( vs. , ). The median dosimetric indices (GK vs. CK, with range) were: RTOG_CI, 1.76 (1.12‐4.14) vs. 1.53 (1.16‐2.12), ; CI, 1.76 (1.15‐4.14) vs. 1.55 (1.18‐2.21), ; nCI, 1.76 (1.59‐4.14) vs. 1.57 (1.20‐2.30), ; GI50, 2.91 (2.48‐3.67) vs. 4.90 (3.42‐11.68), ; GI25, 6.58 (4.18‐10.20) vs. 14.85 (8.80‐48.37), . Average volume ratio (AVR) differences favored GK at multiple normalized isodose levels . We concluded that in patients with brain metastases, CK and GK resulted in dosimetrically comparable plans that were nearly equivalent in several metrics, including target coverage and minimum dose within the target. Compared to GK, CK produced more homogenous plans with significantly lower mean and maximum doses, and achieved more conformal plans by RTOG_CI criteria. By GI and AVR analyses, GK plans had sharper peripheral dose falloff in most cases.PACS number: 89.20.‐a
Total skin electron therapy in the lying‐on‐the‐floor position using a customized flattening filter to accommodate frail patients
Deufel, Christopher L. , Antolak, John A.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 5 | Pages: 115-126

10.1120/jacmp.v14i5.4309 | PMID 24036864 Get It

A total skin electron (TSE) floor technique is presented for treating patients who are unable to safely stand for extended durations. A customized flattening filter is used to eliminate the need for field junctioning, improve field uniformity, and reduce setup time. The flattening filter is constructed from copper and polycarbonate, fits into the linac's accessory slot, and is optimized to extend the useful height and width of the beam such that no field junctions are needed during treatment. A TSE floor with flattening filter (TSE FF) treatment course consisted of six patient positions: three supine and three prone. For all treatment fields, electron beam energy was 6 MeV; collimator settings were an x of 30 cm, y of 40 cm, and of 0°; and a 0.4 cm thick polycarbonate spoiler was positioned in front of the patient. Percent depth dose (PDD) and photon contamination for the TSE FF technique were compared with our standard technique, which is similar to the Stanford technique. Beam profiles were measured using radiochromic film, and dose uniformity was verified using an anthropomorphic radiological phantom. The TSE FF technique met field uniformity requirements specified by the American Association of Physicists in Medicine Task Group 30. TSE FF ranges from 4 to 4.8 mm. TSE FF photon contamination was ~ 3%. Anthropomorphic radiological phantom verification demonstrated that dose to the entire skin surface was expected to be within about of the prescription dose, except for the perineum, scalp vertex, top of shoulder, and soles of the feet. The TSE floor technique presented herein eliminates field junctioning, is suitable for patients who cannot safely stand during treatment, and provides comparable quality and uniformity to the Stanford technique.PACS number: 87
Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
Kim, Taeho , Serago, Christopher F., Vallow, Laura A., Peterson, Jennifer , Lee, Rena , Kim, Siyong , Ko, Stephen J. , Smith, Ashley A.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 5 | Pages: 79-89

10.1120/jacmp.v14i5.4283 | PMID 24036861 Get It

The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning target volume (PTV) with an aperture margin (AM) to compensate for the penumbra effect with gantry rotation. It is a common belief the AM should be positive (or at least ‘zero'). However, the radial penumbra width becomes significantly wider because of continuously overlapped beams in arc delivery. Therefore, we hypothesize if the ‘negative margin’ is applied in the radial direction, it would improve the PTV dose conformation while reducing normal tissue dose. For verification, trial plans were made using the NMT and compared with ‘zero margin (ZM)’ plans for five lung SBRT cases representing different situations depending on the location of the PTV and organs at risk. All plans met 95% PTV coverage with the prescription dose and spared the spinal cord below the tolerance. Two conventional conformation indices (the ratio of prescription isodose volume to the PTV (CI100) and the ratio of 50% prescription isodose volume to the PTV (CI50)) and a modified conformation index were investigated. The maximum dose at 2 cm from the PTV and the percent of lung volume receiving 20 Gy were also evaluated. Another planning simulation was performed with a total of ten randomly selected lung SBRT cases to mimic actual practice. In this simulation, optimization with ZM was first performed and further optimization using the NMT was processed for cases that could not meet a goal of with the ZM optimization. In all cases, both the and values were significantly reduced (overall, and for and , respectively). The modified conformation index values also showed similar improvement (overall, increase). Reduction of was also observed in all cases . values decreased in all cases but one (, excluding the increased case). In the random group simulation, it was possible to achieve the goal with just one NMT trial for five out of six cases that did not meet the goal in the ZM optimization. Interestingly, however, one case needed as many as six iterations to get the goal. The NMT turned out to be an effective planning strategy that could bring significant improvement of dose conformation. The NMT can be easily implemented in most clinics with no prerequisite.PACS number: 87.55.D‐