Pulmonary nocardiosis is a severe and uncommon opportunistic infection caused by Nocardia species. We present a patient with cryptogenic organizing pneumonia who was receiving long-term immunosuppressive therapy, whose treatment course was complicated by cutaneous and pulmonary nocardiosis. Tissue cultures confirmed Nocardia brasiliensis. Nocardiosis should be a diagnostic consideration for patients treated with long-term immunosuppression who have worsening pulmonary symptoms and relapsing pustular skin lesions.
Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
AbstractPurposeLocal control for Ewing sarcoma (ES) has improved in modern studies. However, it is unclear if these gains have also been achieved for pelvis tumors. The purpose of this study is to evaluate local control and survival in pelvis ES patients treated in the modern era.MethodsAll pelvis ES patients diagnosed from 1990 to 2012 and seen at Mayo Clinic were identified. Factors relevant to survival and local control were analyzed.ResultsThe cohort consisted of 48 patients. Fifty‐two percent had metastatic disease at diagnosis. The 5‐year overall survival and event‐free survival was 73% and 65%, respectively, for localized disease. The 5‐year cumulative incidence of local recurrence was 19%, with a 26% incidence for radiation, 13% for surgery, and 0% for surgery + radiation (P = 0.54). All local failures occurred in‐field. Sacral involvement by tumor trended toward a higher incidence of local recurrence (hazard ratio 3.06, P = 0.09). Patients treated with definitive radiation doses ≥5,600 cGy had a lower incidence of local recurrence (17% vs. 28%, P = 0.61).ConclusionsOur study demonstrates excellent survival for localized tumors in the modern era. Anatomical localization within the pelvis likely correlates with outcomes. Local control remains problematic, especially for patients treated with definitive radiation. Though statistically not significant, surgery + radiation and definitive radiation dose ≥5,600 cGy were associated with the lowest incidence of local failure, suggesting treatment intensification may improve local control for pelvis ES.
Confounding by Indication Limits Conclusions of Study of Palivizumab Effectiveness
Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standard CT methods in the presence of high‐Z materials and artifacts, despite the reduced HU resolution of extended CT. Gafchromic film measurements were made for comparison to calculated doses. The method of direct dose calculation on extended CT scale was compared to our institution's standard method of manually contouring and assigning metal values on saturated CT images for each of the metal samples. Clinical patient plans with metal implants were investigated and DVHs were compared between standard CT and extended CT dose calculations. Dose calculations showed agreement within 2% between the two methods of metal characterization and the film measurement in the case of the strongest metal attenuator, cobalt‐chromium. In the clinical treatment plans, the greatest dose discrepancy between the two methods was 1.2%. This study suggests that direct dose calculation on an extended scale CT image in the presence of metal implants can produce accurate clinically viable treatment plans, thereby improving efficiency of clinical workflow and eliminating a potential source of human error by manual CT number assignment.PACS number(s): 87.55.dk
Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset
The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent commercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC‐calculated electron dose distributions for bolus ECT have been compared to previously measured TLD‐dose points throughout patient‐based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid‐PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and statistical uncertainties. The accuracy of the dose calculations using moderate smoothing and no smoothing were evaluated. Dose differences (eMC‐calculated less measured dose) were evaluated in terms of absolute dose difference, where 100% equals the given dose, as well as distance to agreement (DTA). Dose calculations were also evaluated for calculation speed. Results from the eMC for the retromolar trigone phantom using 1% statistical uncertainty without smoothing showed calculated dose at of the measured TLD‐dose points was within 3% dose difference or 3 mm DTA of the measured value. The average dose difference was , and the net standard deviation was 2.32%. Differences as large as 3.7% occurred immediately distal to the mandible bone. Results for the nose phantom, using 1% statistical uncertainty without smoothing, showed calculated dose at of the measured TLD‐dose points within 3% dose difference or 3 mm DTA. The average dose difference was 1.08%, and the net standard deviation was 3.17%. Differences as large as 10% occurred lateral to the nasal air cavities. Including smoothing had insignificant effects on the accuracy of the retromolar trigone phantom calculations, but reduced the accuracy of the nose phantom calculations in the high‐gradient dose areas. Dose calculation times with 1% statistical uncertainty for the retromolar trigone and nose treatment plans were 30 s and 24 s, respectively, using 16 processors (Intel Xeon E5‐2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high‐gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.PACS number(s): 87.55.kd