Citations

Mayo Clinic

Showing 10 of 108599 citations.

Measurement of tissue viscoelasticity with ultrasound
Greenleaf, James F. , Alizad, Azra

SPIE Proceedings | February 28, 2017 | Volume: 10067 | Issue: No issue available | Pages: 1006705

10.1117/12.2256842 Get It

Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy
Matney, J, Park, Peter C., Court, Laurence E. , Zhu, X. Ron, Dong, Lei , Li, Heng , Liu, Wei , Mohan, Radhe

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 2 | Pages: 368-378

10.1120/jacmp.v17i2.5795 | PMID 27074459 Get It

Respiratory motion is traditionally assessed using tumor motion magnitude. In proton therapy, respiratory motion causes density variations along the beam path that result in uncertainties of proton range. This work has investigated the use of water‐equivalent thickness (WET) to quantitatively assess the effects of respiratory motion on calculated dose in passively scattered proton therapy (PSPT). A cohort of 29 locally advanced non‐small cell lung cancer patients treated with 87 PSPT treatment fields were selected for analysis. The variation in WET (ΔWET) along each field was calculated between exhale and inhale phases of the simulation four‐dimensional computed tomography. The change in calculated dose (ΔDose) between full‐inhale and full‐exhale phase was quantified for each field using dose differences, 3D gamma analysis, and differential area under the curve (ΔAUC) analysis. Pearson correlation coefficients were calculated between ΔDose and ΔWET. Three PSPT plans were redesigned using field angles to minimize variations in ΔWET and compared to the original plans. The median ΔWET over 87 treatment fields ranged from 1‐9 mm, while the ΔWET 95th percentile value ranged up to 42 mm. The ΔWET was significantly correlated to the ΔDose for all metrics analyzed. The patient plans that were redesigned using ΔWET analysis to select field angles were more robust to the effects of respiratory motion, as ΔAUC values were reduced by more than 60% in all three cases. The tumor motion magnitude alone does not capture the potential dosimetric error due to respiratory motion because the proton range is sensitive to the motion of all patient anatomy. The use of ΔWET has been demonstrated to identify situations where respiratory motion can impact the calculated dose. Angular analysis of ΔWET may be capable of designing radiotherapy plans that are more robust to the effects of respiratory motion.PACS number(s): 87.55.‐x
Implementation of an in‐house visual feedback system for motion management during radiation therapy
Ellerbusch, D, Cetnar, Ashley J. , James, Joshua A., Wang, Brian , Nguyen, Vi

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 1 | Pages: 421-427

10.1120/jacmp.v17i1.5817 | PMID 26894353 Get It

In this Technical Note, we describe an in‐house video goggles feedback system assembled using several commercially available products. This goggle video feedback system is currently being used at University of Louisville and Mayo Clinic for both CT simulation and linac treatment delivery. The setup details, including specific recommendations, are provided, along with an alternative option for using the video goggles system.PACS number: 07.07Hj
Alignment of multiradiation isocenters for megavoltage photon beam
Cowan, Garth, Tryggestad, E., Wang, Ken Kang‐Hsin, Zhang⋆, Yin , Ding, Kai , Armour, Elwood P. , Wang, Ken Kang‐Hsin

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 16 | Issue: 6 | Pages: 314-324

10.1120/jacmp.v16i6.5733 | PMID 26699586 Get It

The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening filters and bending magnet and steering parameters, the radiation isocenter of one energy mode can deviate from another if no special effort was devoted. We present the first experience of the multiradiation isocenters alignment on an Elekta linac, as well as its corresponding QA procedure and clinical impact. An 8 mm ball‐bearing (BB) phantom was placed at the 6 MV radiation isocenter using an Elekta isocenter search algorithm, based on portal images. The 3D radiation isocenter shifts of other photon energy modes relative to the 6 MV were determined. Beam profile scanning for different field sizes was used as an independent method to determine the 2D multiradiation isocenters alignment. To quantify the impact of radiation isocenter offset on targeting accuracy, the 10 MV radiation isocenter was manually offset from that for 6 MV by adjusting the bending magnet current. Because our table isocenter was mechanically aligned to the 6 MV radiation isocenter, the deviation of the table isocentric rotation from the "shifted" 10 MV radiation isocenter after bending magnet adjustment was assessed. Winston‐Lutz test was also performed to confirm the overall radiation isocenter positioning accuracy for all photon energies. The portal image method showed the radiation isocenter of the 10 MV flattening filter‐free mode deviated from others before beam parameter adjustment. After the adjustment, the deviation was greatly improved from 0.96 to 0.35 mm relative to the 6 MV radiation isocenter. The same finding was confirmed by the profile‐scanning method. The maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter was observed to linearly increase with the offset between 6 and 10 MV radiation isocenter; 1 mm radiation isocenter offset can translate to almost 2 mm maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter. The alignment of the multiradiation isocenters is particularly important for high‐precision radiotherapy. Our study provides the medical physics community with a quantitative measure of the multiradiation isocenters alignment. A routine QA method should be considered, to examine the radiation isocenters alignment during the linac acceptance.PACS number: 87.55.Qr, 87.56.bd, 87.56.Fc
Seed coordinates of a new COMS‐like 24 mm plaque verified using the FARO Edge
Cutsinger, Jordan McCauley, Forsman, Renae M., Corner, Stephen, McCauley Cutsinger, Sarah E, Cutsinger, Jordan McCauley, Furutani, Keith M.

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 16 | Issue: 6 | Pages: 293-301

10.1120/jacmp.v16i6.5721 | PMID 26699584 Get It

A 24 mm COMS‐like eye plaque was developed to meet the treatment needs of our eye plaque brachytherapy practice. As part of commissioning, it was necessary to determine the new plaque's seed coordinates. The FARO Edge, a commercially available measurement arm, was chosen for this purpose. In order to validate the FARO Edge method, it was first used to measure the seed marker coordinates in the silastic molds for the standard 10, 18, and 20 mm COMS plaques, and the results were compared with the standard published Task Group 129 coordinates by a nonlinear least squares match in MATLAB version R2013a. All measured coordinates were within 0.60 mm, and root mean square deviation was 0.12, 0.23, and 0.35 mm for the 10, 18, and 20 mm molds, respectively. The FARO Edge was then used to measure the seed marker locations in the new 24 mm silastic mold. Those values were compared to the manufacturing specification coordinates and were found to demonstrate good agreement, with a maximum deviation of 0.56 mm and a root mean square deviation of 0.37 mm. The FARO Edge is deemed to be a reliable method for determining seed coordinates for COMS silastics, and the seed coordinates for the new 24 mm plaque are presented.PACS number: 87.53.Jw
Structural properties of amyloid β(1‐40) dimer explored by replica exchange molecular dynamics simulations
Watts, Charles R. , Gregory, Andrew , Frisbie, Cole P., Lovas, Sándor , Gregory, Andrew J, Gregory, Andrew J.

Proteins: Structure, Function, and Bioinformatics | February 27, 2017 | Volume: 85 | Issue: 6 | Pages: 1024-1045

10.1002/prot.25270 | PMID 28241387 Get It

ABSTRACTReplica exchange molecular dynamics simulations (300 ns) were used to study the dimerization of amyloid β(1‐40) (Aβ(1‐40)) polypeptide. Configurational entropy calculations revealed that at physiological temperature (310 K, 37°C) dynamic dimers are formed by randomly docked monomers. Free energy of binding of the two chains to each other was −93.56 ± 6.341 kJ mol−1. Prevalence of random coil conformations was found for both chains with the exceptions of increased β‐sheet content from residues 16‐21 and 29‐32 of chain A and residues 15‐21 and 30‐33 of chain B with β‐turn/β‐bend conformations in both chains from residues 1‐16, 21‐29 of chain A, 1‐16, and 21‐29 of chain B. There is a mixed β‐turn/β‐sheet region from residues 33‐38 of both chains. Analysis of intra‐ and interchain residue distances shows that, although the individual chains are highly flexible, the dimer system stays in a loosely packed antiparallel β‐sheet configuration with contacts between residues 17‐21 of chain A with residues 17‐21 and 31‐36 of chain B as well as residues 31‐36 of chain A with residues 17‐21 and 31‐36 of chain B. Based on dihedral principal component analysis, the antiparallel β‐sheet‐loop‐β‐sheet conformational motif is favored for many low energy sampled conformations. Our results show that Aβ(1‐40) can form dynamic dimers in aqueous solution that have significant conformational flexibility and are stabilized by collapse of the central and C‐terminal hydrophobic cores with the expected β‐sheet‐loop‐β‐sheet conformational motif. Proteins 2017; 85:1024–1045. © 2017 Wiley Periodicals, Inc.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
Brinjikji, Waleed , Michalak, Gregory J. , Kadirvel, Ramanathan , Gilvarry, Michael , Duffy, Sharon , Kallmes, David F. , Dai, Daying , McCollough, Cynthia, McCollough, Cynthia H. , Leng, Shuai

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189 Get It

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.
Correlation between clot density and recanalization success or stroke etiology in acute ischemic stroke patients
Jagani, Manoj, Kallmes, David F. , Brinjikji, Waleed

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 274-278

10.1177/1591019917694478 | PMID 28604188 Get It

Background Predicting recanalization success for patients undergoing endovascular treatment for acute ischemic stroke is of significant interest. Studies have previously correlated the success of recanalization with the density of the clot. We evaluated clot density and its relationship to revascularization success and stroke etiology. Methods We conducted a retrospective review of 118 patients undergoing intra-arterial therapy for acute ischemic stroke. Mean and maximum thrombus density was measured by drawing a circular region of interest on an axial slice of a non-contrast computed tomography scan. T-tests were used to compare clot density to recanalization success or to stroke etiology, namely large artery atherosclerosis and cardioembolism. Recanalization success was compared in four device groups: aspiration, stent retriever, aspiration and stent retriever, and all other. Results There was no significant difference in the mean clot density in patients with successful ( n = 80) versus unsuccessful recanalization ( n = 38, 50.1 ± 7.4 Hounsfield unit (HU) vs. 53 ± 12.7 HU; P = 0.17). Comparing the large artery thromboembolism ( n = 35) to the cardioembolic etiology group ( n = 56), there was no significant difference in mean clot density (51.5 ± 7.7 HU vs. 49.7 ± 8.5 HU; P = 0.31). A subgroup analysis of middle cerebral artery occlusions ( n = 65) showed similar, non-statistically significant differences between groups. There was no difference in the rate of recanalization success in patients with a mean clot density greater than 50 HU or less than 50 HU in each of the four device groups. Conclusions There was no relationship between clot density and revascularization success or stroke etiology in our study. More research is needed to determine if clot density can predict recanalization rates or indicate etiology.
The impact of CyberKnife's prescription isodose percentage on intracranial target planning
Jang, Sunyoung, Pyakuryal, Anil, Lee, Sung‐Woo , Jang, Sunyoung, Chang, Kenneth, Sio, Terence T.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 278-280

10.1120/jacmp.v15i5.5081 | PMID 25207584 Get It

Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors
Miller, Robert C. , Santos, Luis E. Fong de los, Hallemeier, Christopher L. , Foster, Nathan R. , Bauer, Heather, Chang, Kenneth J. , Garces, Yolanda I. , Olivier, Kenneth R. , Sio, Terence T. , Jensen, Andrew R. , Hallemeier, Christopher Leigh , Park, Sean S.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 235-245

10.1120/jacmp.v15i5.4931 | PMID 25207580 Get It

The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung tumors. Two SBRT immobilization strategies were used: full‐length BodyFIX and thermoplastic S‐frame. At simulation, free‐breathing, four‐dimensional computed tomography was performed. For each treatment, patients were set up to isocenter with in‐room lasers and skin tattoos. Shifts from initial and subsequent couch positions with cone‐beam computed tomography (CBCT) were analyzed. Accounting for setup uncertainties, institutional tolerance of CBCT‐based shifts for treatment was 2, 2, and 4 mm in left–right, anterior–posterior, and cranial–caudal directions, respectively; shifts exceeding these limits required reimaging. Each patient's pretreatment pulmonary function test was recorded. A multistep, multivariate linear regression model was performed to elucidate intervariable dependency for three‐dimensional calculated couch shift parameters. BodyFIX was applied to 76 tumors and S‐frame to 17 tumors. Of these tumors, 41 were non–small cell lung cancer and 15 were metastatic from other sites. Lesions measured , 1.1 to 2 (50%), 2.1 to 3 (25%), and cm. Errors from first shifts of first fractions were significantly less with S‐frame than BodyFIX (). No difference in local control (LC) was found between S‐frame and BodyFIX (); two‐year LC rate was 94%. Multivariate modeling confirmed that the ratio of forced expiratory volume in the first second of expiration to forced vital capacity, body habitus, and the immobilization device significantly impacted couch shift errors. For upper lung tumors, initial setup was more consistent with S‐frame than BodyFIX, resulting in fewer CBCT scans. Patients with obese habitus and poor lung function had more SBRT setup uncertainty; however, outcome and probability for LC remained excellent.PACS number: 89.20.‐a