Alpha DaRT source activity confirmation using a reentrant well‐type ionization chamber
Deufel, Christopher L. , Ordog, Jasmine L., Underwood, Kyle, Cohen, Yadin, Damato, Antonio L., Malouff, Timothy D., Underwood, James Kyle, Cohen, Gil’ad N. , Damato, Antonio L, Malouff, Timothy D.

Medical Physics | June 8, 2026 | Volume: 53 | Issue: 6 | Pages: No page available

10.1002/mp.70515 Get It

Abstract Background Alpha‐emitting radionuclides enable precise cancer therapy through high linear energy transfer and limited tissue penetration, damaging tumor cells while sparing healthy tissue. Diffusing Alpha‐emitters Radiation Therapy (Alpha DaRT) features Ra‐224 sources that are implanted directly into the tumor and emit alpha particles during radioactive decay. Alpha DaRT has demonstrated efficacy and safety in preclinical and early clinical trials across multiple tumor types, including skin, head and neck, and pancreatic cancers. Purpose Reliable and efficient methods for verifying Alpha DaRT source activity prior to treatment can help support accurate and consistent radiation delivery. The direct measurement of alpha particles from sources within an Alpha DaRT applicator is impractical due to their short range; however, gamma emissions from the Ra‐224 sources can be used to infer radioactivity. This study established a protocol for verifying the source activity within Ra‐224 Alpha DaRT applicators using a reentrant well‐type ionization chamber, providing users with a practical method for detecting errors in source manufacturing or certificate paperwork without compromising applicator sterility. Methods Ra‐224 Alpha DaRT sources in sterile packaging (Flex and Needle applicators with 1–4 sources) were assessed. Source energy spectra and activities were verified using a high‐purity germanium (HPGe) radiation detector. Calibration factors (kBq/pA) were established using an IVB1000 well‐type ionization chamber with measurements conducted by placing single applicator sterile packages into the chamber with sources centered in the chamber's sweet spot and corrected for temperature, pressure, and leakage current. Quality assurance was performed on 26 Flex applicators using the established calibrations before the first clinical procedure. Results HPGe measurements agreed with vendor‐stated activities. The average calibration coefficient using the IVB1000 chamber was 233 ± 3 kBq/pA for Flex and 597 ± 7 kBq/pA for Needle applicators. Calibration coefficients were consistent across two IVB1000 chambers. Source number dependence was observed, with calibration factors increasing by 1.7% ± 0.7% per source (Needle) and 2.7% ± 0.6% per source (Flex). Measurement repeatability was 3.3%. Applying the calibration to 26 Flex applicators before the first patient treatment yielded a 1.1 ± 5.8% (range: −7.5% to 11.4%) difference relative to the vendor's stated activity. Conclusion A reentrant well‐type ionization chamber is suitable for pre‐treatment quality assurance of Ra‐224 Alpha DaRT applicators, enabling verification of the vendor‐stated activity while maintaining sterility within sealed packaging.
AAPM task group 317 report: A joint AAPM and ESTRO report on brachytherapy catheter, needle, and applicator tracking technology
Battisti, Maxence Borot de, Cunha, J. Adam M. , Damato, Antonio L. , Deufel, Christopher L. , Hautvast, Gilion, Hsu, I‐Chow , Kolkman‐Deurloo, Inger‐Karine K. , Moerland, Marinus A. , Niatsetski, Yury , Beaulieu, Luc , Bert, Christoph , Cormack, Robert A. , Weersink, Robert , Tanderup, Kari

Medical Physics | October 7, 2025 | Volume: 52 | Issue: 10 | Pages: No page available

10.1002/mp.70037 Get It

Abstract In recent years, various tracking technologies that work independently of imaging systems have been proposed to automate, simplify, and enhance various tasks in the brachytherapy treatment workflow. These tasks, critical to the overall accuracy of the therapeutic dose delivery, include applicator, catheter and needle insertion guidance, and reconstruction as well as transfer tube connection in afterloading technique. Task Group 317 was established as a joint American Association of Physicists in Medicine (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) committee to review: the current state‐of‐the‐art scientific literature as it pertains to tracking technology in the field of brachytherapy; the benefits and issues related to the use of the technology for automated reconstruction of brachytherapy implants, quality control (QC) tasks such as channel path and tip reconstruction, and real‐time guidance tasks; their limitations, in particular in the clinical environment and, finally, to develop recommendations related to commissioning, quality assurance (QA) and clinical use. The Task Group has looked in detail at key tracking technologies in advanced brachytherapy applications: infrared, electromagnetic, fiber optic shape sensing (fiber Bragg grating), and active radiofrequency coil tracking. For each, the performance and accuracy in well‐controlled conditions as well as in clinically relevant environments are provided. Guidelines for clinical implementations, including target accuracy and performance needed for critical tasks, are summarized. Risk‐based analysis is discussed in the context of an electromagnetic‐based tracking system used as part of a clinical trial. The report concludes with the essential elements of an effective quality management program dedicated to the advanced features enabled by the above‐described technology.
Simulation‐free workflow for lattice radiation therapy using deep learning predicted synthetic computed tomography: A feasibility study
Yu, Nathan Y. , Ashman, Jonathan B. , Toesca, Diego Santos, Deufel, Christopher L. , Duan, Jingwei , Chen, Quan , Rong, Yi , Chen, Quan , Ahmed, Safia K. , Duan, Jingwei , Rong, Yi , Toesca, Diego A.S. , Zhu, Libing , Grams, Michael P.

Journal of Applied Clinical Medical Physics | June 12, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70137 Get It

Abstract Purpose Lattice radiation therapy (LRT) is a form of spatially fractionated radiation therapy that allows increased total dose delivery aiming for improved treatment response without an increase in toxicities, commonly utilized for palliation of bulky tumors. The LRT treatment planning process is complex, while eligible patients often have an urgent need for expedited treatment start. In this study, we aimed to develop a simulation‐free workflow for volumetric modulated arc therapy (VMAT)‐based LRT planning via deep learning‐predicted synthetic CT (sCT) to expedite treatment initiation. Methods Two deep learning models were initially trained using 3D U‐Net architecture to generate sCT from diagnostic CTs (dCT) of the thoracic and abdomen regions using a training dataset of 50 patients. The models were then tested on an independent dataset of 15 patients using image similarity analysis assessing mean absolute error (MAE) and structural similarity index measure (SSIM) as metrics. VMAT‐based LRT plans were generated based on sCT and recalculated on the planning CT (pCT) for dosimetric accuracy comparison. Differences in dose volume histogram (DVH) metrics between pCT and sCT plans were assessed using the Wilcoxon signed‐rank test. Results The final sCT prediction model demonstrated high image similarity to pCT, with a MAE and SSIM of 38.93 ± 14.79 Hounsfield Units (HU) and 0.92 ± 0.05 for the thoracic region, and 73.60 ± 22.90 HU and 0.90 ± 0.03 for the abdominal region, respectively. There were no statistically significant differences between sCT and pCT plans in terms of organ‐at‐risk and target volume DVH parameters, including maximum dose (Dmax), mean dose (Dmean), dose delivered to 90% (D90%) and 50% (D50%) of target volume, except for minimum dose (Dmin) and (D10%). Conclusion With demonstrated high image similarity and adequate dose agreement between sCT and pCT, our study is a proof‐of‐concept for using deep learning predicted sCT for a simulation‐free treatment planning workflow for VMAT‐based LRT.
Reinforcement learning‐based anatomical maps for pancreas subregion and duct segmentation
Amiri, Sepideh , Mustafaev, Tamerlan , Deufel, Christopher L. , Brandt, Erik Gudmann Steuble , Müller, Christoph , Ibragimov, Bulat , Vrtovec, Tomaž , Thomsen, Henrik S. , Sillesen, Martin , Andersen, Michael Brun

Medical Physics | July 19, 2024 | Volume: 51 | Issue: 10 | Pages: 7378-7392

10.1002/mp.17300 Get It

AbstractBackgroundThe pancreas is a complex abdominal organ with many anatomical variations, and therefore automated pancreas segmentation from medical images is a challenging application.PurposeIn this paper, we present a framework for segmenting individual pancreatic subregions and the pancreatic duct from three‐dimensional (3D) computed tomography (CT) images.MethodsA multiagent reinforcement learning (RL) network was used to detect landmarks of the head, neck, body, and tail of the pancreas, and landmarks along the pancreatic duct in a selected target CT image. Using the landmark detection results, an atlas of pancreases was nonrigidly registered to the target image, resulting in anatomical probability maps for the pancreatic subregions and duct. The probability maps were augmented with multilabel 3D U‐Net architectures to obtain the final segmentation results.ResultsTo evaluate the performance of our proposed framework, we computed the Dice similarity coefficient (DSC) between the predicted and ground truth manual segmentations on a database of 82 CT images with manually segmented pancreatic subregions and 37 CT images with manually segmented pancreatic ducts. For the four pancreatic subregions, the mean DSC improved from 0.38, 0.44, and 0.39 with standard 3D U‐Net, Attention U‐Net, and shifted windowing (Swin) U‐Net architectures, to 0.51, 0.47, and 0.49, respectively, when utilizing the proposed RL‐based framework. For the pancreatic duct, the RL‐based framework achieved a mean DSC of 0.70, significantly outperforming the standard approaches and existing methods on different datasets.ConclusionsThe resulting accuracy of the proposed RL‐based segmentation framework demonstrates an improvement against segmentation with standard U‐Net architectures.
Color VISION for improved ultrasound visualization of brachytherapy needles
Dupere, Justine M , Brost, Eric E., Hainy, Matthew E, Lee, Christine U. , Stish, Bradley J. , Deufel, Christopher L. , Dupere, Justine , Brost, Eric, Urban, Matthew W.

Medical Physics | April 17, 2024 | Volume: 51 | Issue: 6 | Pages: 4340-4350

10.1002/mp.17083 Get It

AbstractBackgroundHigh dose rate brachytherapy is commonly used in the treatment of prostate cancer. Treatment planning is often performed under transrectal ultrasound (US) guidance, but brachytherapy needles can be challenging to digitize due to the presence of poor US conspicuity and imaging artifacts. The plan accuracy and quality, however, are dependent on the proper visualization of the needles with millimeter accuracy.PurposeThis work describes a technique for generating a color overlay of needle locations atop the grayscale US image. Prototype devices were developed to produce vibrations in the brachytherapy needles that generate a high contrast color Doppler (CD) signal that highlights the needle locations with superior contrast and reduced artifacts. Denoted by the acronym color VISION (Vibrationally Induced Shimmering for Identifying an Object's Nature), the technology has the potential to improve applicator conspicuity and facilitate automated applicator digitization.MethodsThree prototype vibrational devices with frequencies between 200–450 Hz were designed in‐house and evaluated with needle implants in a phantom and cadaveric male pelvis using: (1) an actuator attached to the front of a prostate needle template; (2) an actuator attached to the top of the needle template; and (3) a hand‐held actuator with a stylet, inserted directly into a needle's inner lumen. Acquired images were postprocessed in MATLAB to evaluate the potential for automated digitization.ResultsAll prototype devices produced localized shimmering in implanted brachytherapy needles in both the axial and sagittal planes. The template mounted actuators provided better vibrational coupling and ease of operation than the stylet prototype. The Michelson contrast, or visibility, of the shimmering CD signal was 100% compared with ≤40% for B‐mode imaging of a single needle. Proof‐of‐principle for automated applicator digitization using only the CD signal was demonstrated.ConclusionsThe color VISION prototype devices successfully coupled mechanical vibrations into brachytherapy needles to generate US CD shimmering and accurately highlight brachytherapy needle locations. The high contrast and natively registered signal are promising for future work to automate the needle digitization and provide a real‐time visual overlay of the applicator on the B‐mode US image.
Automated target placement for VMAT lattice radiation therapy: enhancing efficiency and consistency
Deufel, Christopher L. , Kavanaugh, James , Finley, Randi R., Lang, Karen , Sorenson, Kasie L., Spreiter, Sheri M., Brooks, Jamison , Haddock, Michael G. , Petersen, Ivy A. , Owen, Dawn, Deufel, Christopher, Finley, Randi, Sorenson, Kasie, Spreiter, Sheri, Moseley, Douglas, Ahmed, Safia K. , Owen, Dawn W, Brooks, Jamison , Dodoo, Christopher , Moseley, D , Daniel, J. , Park, Sean S. , Grams, Michael P.

Physics in Medicine & Biology | February 29, 2024 | Volume: 69 | Issue: 7 | Pages: 075010

10.1088/1361-6560/ad2ee8 Get It

Abstract Objective . An algorithm was developed for automated positioning of lattice points within volumetric modulated arc lattice radiation therapy (VMAT LRT) planning. These points are strategically placed within the gross tumor volume (GTV) to receive high doses, adhering to specific separation rules from adjacent organs at risk (OARs). The study goals included enhancing planning safety, consistency, and efficiency while emulating human performance. Approach . A Monte Carlo-based algorithm was designed to optimize the number and arrangement of lattice points within the GTV while considering placement constraints and objectives. These constraints encompassed minimum spacing between points, distance from OARs, and longitudinal separation along the z -axis. Additionally, the algorithm included an objective to permit, at the user’s discretion, solutions with more centrally placed lattice points within the GTV. To validate its effectiveness, the automated approach was compared with manually planned treatments for 24 previous patients. Prior to clinical implementation, a failure mode and effects analysis (FMEA) was conducted to identify potential shortcomings. Main results. The automated program successfully met all placement constraints with an average execution time (over 24 plans) of 0.29 ±0.07 min per lattice point. The average lattice point density (# points per 100 c.c. of GTV) was similar for automated (0.725) compared to manual placement (0.704). The dosimetric differences between the automated and manual plans were minimal, with statistically significant differences in certain metrics like minimum dose (1.9% versus 1.4%), D5% (52.8% versus 49.4%), D95% (7.1% versus 6.2%), and Body-GTV V30% (20.7 c.c. versus 19.7 c.c.). Significance. This study underscores the feasibility of employing a straightforward Monte Carlo-based algorithm to automate the creation of spherical target structures for VMAT LRT planning. The automated method yields similar dose metrics, enhances inter-planner consistency for larger targets, and requires fewer resources and less time compared to manual placement. This approach holds promise for standardizing treatment planning in prospective patient trials and facilitating its adoption across centers seeking to implement VMAT LRT techniques.
Improving ultrasound‐based brachytherapy needle conspicuity by applying an echogenic coating
Brost, Eric E., Stish, Bradley J. , Lee, Christine U. , Deufel, Christopher L. , Brost, Eric, Urban, Matthew W.

Medical Physics | December 13, 2022 | Volume: 50 | Issue: 3 | Pages: 1418-1427

10.1002/mp.16138 Get It

AbstractBackgroundApplicator conspicuity in ultrasound‐guided brachytherapy procedures is commonly impaired by imaging artifacts or non‐ideal imaging geometry, which can slow down applicator position digitization and increase the geometric uncertainty of the delivered dose distribution.PurposeThe purpose of this study was to improve the conspicuity of high‐dose rate (HDR) brachytherapy needles under B‐mode ultrasound imaging by applying an echogenic surface coating. Our hypothesis was that an echogenic coating would reduce artifacts and improve needle visualization within regions of signal degradation.MethodsIn this study, 17‐gauge, 25‐cm long titanium HDR brachytherapy needles were coated with acoustically reflective microspheres over a 2.5 cm region starting from the needle tip. Three coating thicknesses (27 μm, 40 μm, 64 μm) were compared against an uncoated control needle. The coated and uncoated needles were imaged using B‐mode ultrasound in a tissue‐equivalent prostate phantom and in a cadaverous male pelvis using a transrectal probe. Needle conspicuity was assessed under multiple conditions: a single needle implant, an implant with multiple needles between the probe and the needle of interest, and an angled needle implant. All images were assessed qualitatively for needle conspicuity and the presence of artifacts and quantitatively using grey‐scale image intensity values.ResultsThe 64 μm echogenic coating reduced the magnitude of reverberation artifacts by 31 ± 14% and comet tail artifacts by 40%–70%. The echogenic coating also improved needle contrast, measured by the relative differences in signal intensity compared with the adjacent environment, when needles were angled up to 30° with respect to the transducer probe in the cadaver. The improvements in conspicuity and artifact reduction increased with increasing coating thickness. The performance of the needles coated with the 64 μm thickness was qualitatively superior and yielded high‐contrast, well‐circumscribed signals in the cadaverous male pelvis, even under situations where a needle was acoustically shadowed by multiple other needles.ConclusionsAn echogenic surface coating reduced imaging artifacts and improved needle conspicuity under realistic clinical conditions for ultrasound‐based prostate or gynecological brachytherapy. The improved conspicuity has the potential to improve the efficiency of needle placement and the accuracy of needle position digitization during brachytherapy procedures.
Development of transparent eye shields for total skin electron beam radiotherapy
Lucido, J. John , Veres, Andrew J., Kehret, Shawn M., Angeli, John A., Highet, Robert D., Foote, Robert L. , Lester, Scott C. , Deufel, Chris L., Lester, Scott , Foote, Robert , Lucido, John J , Deufel, Christopher L.

Journal of Applied Clinical Medical Physics | July 11, 2022 | Volume: 23 | Issue: 9 | Pages: No page available

10.1002/acm2.13722 Get It

AbstractPurposeFor total skin electron (TSE) beam radiation therapy, the anterior eye and conjunctiva can be protected with eye shields to prevent keratitis, xerophthalmia, and cataractogenesis. Conventional metal eye shields can reduce patient balance by obscuring vision and thus increasing the risk for falls. We report on the design, fabrication, and clinical use of transparent acrylic eye shields for TSE.MethodsThe primary design goals were a seven‐fold reduction in the dose to the anterior eye and conjunctiva to meet published dose‐recommendations, preservation of vision for the wearer, and biocompatibility for external use. Resembling thick swim goggles, the design features 23 mm thick acrylic lenses that are mounted in a 3‐D printed support structure that conforms to the eye socket and can be worn with a strap. Dose measurements were performed in a simulated Stanford‐technique treatment with an anthropomorphic phantom using Gafchromic EBT filmResultsThe transparent eye shields were manufactured using a 3D‐printer and CNC‐machine. Based on measurements from the simulated treatments for each of the eye shields, the eye shields provided a 12‐fold reduction in dose to the lens. After use in more than 200 fractions, the shields were well tolerated by patients, and there were no reports of any incidents or adverse events.ConclusionTransparent TSE eye shields are able to reduce the dose to the eyes while maintaining vision during treatment at a reasonable cost.
Abstract PD7-03: Ultra-accelerated photon, proton, and brachytherapy partial breast irradiation: Primary results of the Mayo 3-fraction trial
Mutter, Robert W. , Afzal, Arslan, Kenison, Stephanie L, Vallow, Laura A., Deufel, Christopher L. , Remmes, Nicholas B. , Ruddy, Kathryn J. , Vern-Gross, T.Z., Shumway, Dean A. , Wong, William W. , McGee, L.A. , Liu, Minetta C. , Vargas, Carlos , Visscher, Daniel W., Stish, Bradley J. , Pafundi, Deanna, Waddle, Mark R. , Golafshar, Michael A. , Halyard, Michele Y. , Corbin, Kimberly S. , Golafshar, Michael , Hieken, Tina J. , DeWees, T.A. , Boughey, Judy C. , Furutani, Keith M. , Degnim, Amy C. , Jakub, James W. , PATEL, SAMIR N. , Park, Sean S.

Cancer Research | March 8, 2022 | Volume: 82 | Issue: 4_Supplement | Pages: PD7-03-PD7-03

10.1158/1538-7445.sabcs21-pd7-03 Get It

Abstract Background: Partial breast irradiation (PBI) is an established option for selected patients with early stage breast cancer. The optimal technique, target volume and dose/fractionation for PBI has yet to be defined. The most studied regimen in North America (38.5 Gy in 10 fractions twice daily) has been associated with cosmetic deterioration. We hypothesized that condensing treatment and reducing the total administered dose could improve the therapeutic ratio in luminal breast cancer and DCIS based on emerging evidence that breast cancer is more sensitive than surrounding normal tissues to high dose fractions. Herein, we report cosmetic, tolerability, disease control, and patient reported outcomes of a novel ultra-accelerated PBI regimen. Methods: We conducted a single arm, three cohort trial of photon, proton, and brachytherapy PBI. Technique was selected at physician and patient discretion. Eligible women were age ≥ 50 years with estrogen receptor positive (ER+), sentinel lymph node negative invasive or in-situ breast cancer measuring ≤ 2.5 cm. The regimen was designed to have comparable biologically equivalent effect as 40 Gy in 15 fractions, assuming an α/β ratio of 3.5. Intracavitary brachytherapy target volume was lumpectomy cavity plus 1 cm and prescribed 21 Gy in 3 fractions. Photon and proton target volumes were post-operative tumor bed plus 1 cm and a 3 mm setup uncertainty margin, prescribed 21.9 Gy (RBE) in 3 fractions, and delivered with image guidance. The primary outcome was the percentage difference in patients with adverse cosmesis (defined as fair or poor cosmesis) at 3 years compared to baseline pre-PBI, as assessed by trained nurses using the 4-point Harvard breast cosmesis scale. Patients also completed quality of life surveys and self-reported cosmesis using the 4-point scale. Locoregional and distant recurrence-free survival was determined using the Kaplan-Meier method. Adverse events were assessed using CTCAE, v 4.0. Results: Between 2015 and 2017, 163 patients were treated: photons in 58, protons in 48, and brachytherapy in 57. Median patient age was 66 years. 129 (79%) patients had invasive breast cancer (all ER+) and 34 (21%) had DCIS (83% ER+). Median tumor size was 1.1 cm. Grade was 2-3 in 102 (63%). The median mean heart/ipsilateral lung doses were photons 0.1/1.6 Gy, protons <0.001/0.1 Gy, and brachytherapy 0.5/0.9 Gy. Median follow-up was 4.1 years (IQR 3.9-5.0). The proportion of patients with adverse cosmesis (by RN assessment) was 14.3% at baseline and 3.8% at 3 years, with four patients (1 photon, 1 proton, 2 brachytherapy) experiencing cosmetic deterioration at 3 years from baseline. The proportion with adverse cosmesis by self-report at 3 years was 2.4%, with three patients (1 photon, 1 proton, 1 brachytherapy) reporting cosmetic deterioration. Four patients developed locoregional recurrence (1 photons, 2 protons, 1 brachytherapy); three were local only and one was local and distant. 4-year locoregional recurrence and distant metastasis-free survival were 97.9% and 97.4%, respectively. There were 2 treatment related ≥ grade 2 late events (grade 2 fibrosis and grade 2 seroma, both brachytherapy associated), and no evidence of deterioration in patient-reported pain, fatigue, breast related or overall quality of life, as assessed by the patient reported outcomes version of the CTCAE, 10-point linear analog scales, and the breast cancer treatment outcomes scale. Conclusions: Ultra-accelerated 3-fraction PBI exquisitely spared normal tissues and was associated with favorable cosmetic outcomes, disease control, and excellent long-term tolerability. This ‘precision-radiotherapy’ approach may optimize the therapeutic ratio over more aggressive radiotherapy options as well as radiotherapy omission, particularly in patients with long life expectancies. Citation Format: Robert Mutter, Tina Hieken, Todd DeWees, Arslan Afzal, Stephanie Kenison, Laura Vallow, Christopher Deufel, Nicholas Remmes, Kathryn Ruddy, Judy Boughey, Keith Furutani, Amy Degnim, James Jakub, Tamara Vern-Gross, Dean Shumway, William Wong, Samir Patel, Lisa McGee, Minetta Liu, Carlos Vargas, Daniel Visscher, Bradley Stish, Deanna Pafundi, Mark Waddle, Michael Golafshar, Michele Halyard, Kimberly Corbin, Sean Park. Ultra-accelerated photon, proton, and brachytherapy partial breast irradiation: Primary results of the Mayo 3-fraction trial [abstract]. In: Proceedings of the 2021 San Antonio Breast Cancer Symposium; 2021 Dec 7-10; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2022;82(4 Suppl):Abstract nr PD7-03.
On the importance of quality assurance (QA) for COMS eye plaque Silastic inserts: A guide to measurement methods, typical variations, and an example of how QA intercepted a manufacturing aberration
Oare, Courtney, Deufel, Christopher L. , Cutsinger, Jordan McCauley , Herman, Tania De La Fuente, Ferreira, Clara , McCauley Cutsinger, Jordan

Journal of Applied Clinical Medical Physics | July 7, 2021 | Volume: 22 | Issue: 8 | Pages: 72-82

10.1002/acm2.13325 Get It

AbstractPurposeEye plaques are widely used for ocular melanoma and provide an effective alternative to enucleation with adequate tumor control. A COMS plaque utilizes a Silastic insert for precise positioning of the radioactive seeds with respect to the scleral surface of the eye; however, due to manufacturing variability, the insert may unintentionally increase or decrease the distance between the sources and tumor. The purpose of this work is to provide guidance in measuring and identifying outliers in Silastic inserts. The importance of regular quality assurance (QA) is illustrated in an experience where a systematic problem was detected and the manufacturer's 22‐mm mold was corrected.MethodsA detailed description of the molds and manufacturing process used to produce Silastic inserts is provided, including photographs of the process steps. The variability in Silastic insert production was evaluated by measuring the thickness of 124 Silastic inserts. An estimate of how the observed Silastic thickness discrepancies impact the dose to the tumor and critical eye structures was performed using homogeneous dose calculations. A standard QA protocol was developed to guide the clinical user.ResultsThickness of the measured Silastic inserts ranged from 1.22 to 2.67 mm, demonstrating variation from the 2.25 mm standard. Six of the 22‐mm inserts were outliers (Δthickness >3 standard deviations) and were excluded from the statistics. The outliers were investigated with the help of the manufacturer, who discovered that a systematic error was accidentally introduced into the 22‐mm mold.ConclusionsDue to manufacturing errors or variability, the Silastic inserts used in COMS eye plaques may be thicker or thinner than the design standard. Such variations may impact tumor control or increase the risk of normal tissue side effects. A standardized QA program is recommended to detect variations and communicate unusual findings to the manufacturer.