Citations

Mayo Clinic

Clear

806 citation(s) found for "Xu, Yong".

Gastrointestinal Microbiome Disruption and Antibiotic-Associated Diarrhea in Children Receiving Antibiotic Therapy for Community-Acquired Pneumonia
Kong, Yong , Wade, Martina , Williams, Derek J. , Creech, C. Buddy , Walter, Emmanuel B. , Martin, Judy M, Gerber, Jeffrey S. , Newland, Jason G. , Hofto, Meghan E. , Staat, Mary Allen , Chambers, Henry F. , Fowler, Vance G. , Pettigrew, Melinda M. , Pettigrew, M M , Evans, Scott R , Staat, Mary A , Kwon, Jiye , Evans, Scott , Fowler, Vance G. , Huskins, W. Charles

The Journal of Infectious Diseases | March 2, 2022 | Volume: 226 | Issue: 6 | Pages: 1109-1119

10.1093/infdis/jiac082 | PMID 35249113 Get It

Abstract Antibiotic-associated diarrhea (AAD) is a common side effect of antibiotics. We examined the gastrointestinal microbiota in children treated with β-lactams for community-acquired pneumonia. Data were from 66 children (n = 198 samples), aged 6–71 months, enrolled in the SCOUT-CAP trial (NCT02891915). AAD was defined as ≥1 day of diarrhea. Stool samples were collected on study days 1, 6–10, and 19–25. Samples were analyzed using 16S ribosomal RNA gene sequencing to identify associations between patient characteristics, microbiota characteristics, and AAD (yes/no). Nineteen (29%) children developed AAD. Microbiota compositional profiles differed between AAD groups (permutational multivariate analysis of variance, P < .03) and across visits (P < .001). Children with higher baseline relative abundances of 2 Bacteroides species were less likely to experience AAD. Higher baseline abundance of Lachnospiraceae and amino acid biosynthesis pathways were associated with AAD. Children in the AAD group experienced prolonged dysbiosis (P < .05). Specific gastrointestinal microbiota profiles are associated with AAD in children.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Arrhythmias in Female Patients: Incidence, Presentation and Management
Zeitler, Emily P. , Poole, Jeanne E. , Albert, Christine M. , Al‐Khatib, Sana M. , Ali-Ahmed, Fatima, Birgersdotter‐Green, Ulrika , Cha, Yong-Mei, Chung, Mina K. , Curtis, Anne B. , Hurwitz, Jodie L. , Lampert, Rachel , Sandhu, Roopinder K., Shaik, Fatima, Sullivan, Erin, Tamirisa, Kamala P., Wright, Jennifer M. , Russo, Andrea M. , Santos Volgman, Annabelle , Wright, Jennifer M , Russo, Andrea M , Zeitler, Emily P , Poole, Jeanne E. , Albert, Christine M. , Al-Khatib, Sana M. , Ali-Ahmed, Fatima, Birgersdotter-Green, Ulrika Maria , Cha, Yong-Mei, Chung, Mina , Curtis, Anne B. , Hurwitz, Jodie L. , Lampert, Rachel , Sandhu, Roopinder K., Shaik, Fatima, Sullivan, Erin, Tamirisa, Kamala P.

Circulation Research | February 17, 2022 | Volume: 130 | Issue: 4 | Pages: 474-495

10.1161/circresaha.121.319893 | PMID 35175839 Get It

There is a growing appreciation for differences in epidemiology, treatment, and outcomes of cardiovascular conditions by sex. Historically, cardiovascular clinical trials have under-represented females, but findings have nonetheless been applied to clinical care in a sex-agnostic manner. Thus, much of the collective knowledge about sex-specific cardiovascular outcomes result from post hoc and secondary analyses. In some cases, these investigations have revealed important sex-based differences with implications for optimizing care for female patients with arrhythmias. This review explores the available evidence related to cardiac arrhythmia care among females, with emphasis on areas in which important sex differences are known or suggested. Considerations related to improving female enrollment in clinical trials as a way to establish more robust clinical evidence for the treatment of females are discussed. Areas of remaining evidence gaps are provided, and recommendations for areas of future research and specific action items are suggested. The overarching goal is to improve appreciation for sex-based differences in cardiac arrhythmia care as 1 component of a comprehensive plan to optimize arrhythmia care for all patients.
A wearable cardioverter defibrillator with a low false alarm rate
Poole, Jeanne E. , Gleva, Marye J. , Birgersdotter‐Green, Ulrika , Branch, Kelley R. , Salam, Tariq , Crawford, Thomas , Willcox, Mark E. , Sridhar, Arun Mahankali, Mikdadi, Ghiath, Beinart, Sean C., Cha, Yong‐Mei , Russo, Andrea M. , Rowbotham, Ron, Sullivan, Joseph, Gustavson, Laura , Kivilaid, Kaisa, Salam, Tariq , Cha, Yong-Mei , Doshi, Rahul N.

Journal of Cardiovascular Electrophysiology | February 17, 2022 | Volume: 33 | Issue: 5 | Pages: 831-842

10.1111/jce.15417 | PMID 35174572 Get It

AbstractIntroductionA wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort.MethodsOne hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false‐positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient‐day).ResultsOf 163 WCD episodes, 4 were VT/VF and 159 non‐VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false‐positive shock alarm markers were recorded; one false‐positive shock alarm every 1333 patient‐days (0.00075 per patient‐day, 95% confidence interval: 0.00015–0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient‐days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%).ConclusionThe ASSURE WCD demonstrated a low false‐positive shock alarm rate, low patient‐reported discomfort, and no serious adverse events.
Anti‐Neuronal Nuclear Antibody 3 Autoimmunity Targets Dachshund Homolog 1
Ζεκερίδου, Αναστασία , Yang, Binxia , Lennon, Vanda A. , Guo, Yong , Lucchinetti, Claudia F. , McKeon, Andrew , Pittock, Sean J. , Zekeridou, Anastasia , Wu, Liang, McKeon, Andrew , Pittock, S J , Yang, Binxia , Wu, Liang Li , Flanagan, Eoin P.

Annals of Neurology | February 12, 2022 | Volume: 91 | Issue: 5 | Pages: 670-675

10.1002/ana.26320 | PMID 35150165 Get It

The antigen specificity of Anti‐Neuronal Nuclear Antibody‐type 3 (ANNA3)‐IgG is unknown. We identified Dachshund‐homolog 1 (DACH1) as the ANNA3 autoantigen and confirmed it by antigen‐specific assays, immunohistochemical colocalization and immune absorption experiments. Patients' median age was 63.5 years (range, 49–88); 67% were female. Neurological manifestations (information available for 30 patients) included one or more of neuropathy, 12; cognitive difficulties, 11; ataxia, 8; dysautonomia, 7. Evidence of a neoplasm was present in 27 of 30 (90%), most of neuroendocrine lineage. DACH1‐IgG is rare and represents a novel proposed biomarker of neurological autoimmunity and cancer. ANN NEUROL 2022;91:670–675
CT or MR Enterography to Assess Response During Vedolizumab Therapy for Small Bowel Crohn’s Disease
Kwapisz, Lukasz , Bruining, David H. , Lee, Yong S. , Edwards, Phillip K , Holmes, David R. , Carter, Rickey E. , Siegelman, Jenifer , Fletcher, Joel G. , Inoue, Akitoshi , Fletcher, Joel G , Carter, Rickey E

Crohn's & Colitis 360 | February 1, 2022 | Volume: 4 | Issue: 1 | Pages: No page available

10.1093/crocol/otac003 | PMID 36777547 Get It

Abstract Background To describe response to therapy of small bowel (SB) Crohn’s disease (CD) at CT or MR enterography (CTE/MRE) in patients on vedolizumab. Methods Patients with SB CD who underwent CTE/MRE exams greater than 12 months apart on vedolizumab therapy were included. Length (in cm) and inflammation severity (EMBARK score) of inflamed SB segments were assessed. Changes in inflammation length of 3.4 cm or greater or inflammation severity of 2 EMBARK points or greater was categorized as response or progression, as appropriate, with development of newly inflamed segments, strictures, or penetrating complications also indicating progression. Patients not meeting the criteria for response or progression were categorized as having stable disease. Results Of 36 SB CD patients, the large majority had prior surgery (86%; 31), anti-TNF use (92%; 33), and internal penetrating (78%; 28) disease. Thirty-two patients had paired baseline and follow-up CTE/MRE exams without interval surgery, with clinical response observed in 24/32 (75%). Based on imaging response criteria, 22% (7/32; 95% CI: 9%–40%) had response, 50% (16/32; 95% CI: 32%–68%) were stable, and 28% (9/32; 95% CI: 14%–47%) had disease progression. Fifty-six percent of (18/32; 95% CI: 38%–74%) patients had clinical improvement with response or stable disease by imaging. Patients with stable disease had shorter median baseline lengths of SB inflammation (P = .012). Proportion of patients with colonic inflammation, perianal disease, or penetrating complications did not change. Conclusions Most patients on vedolizumab for over 12 months demonstrated response or stable SB disease when using objective cross-sectional radiologic imaging criteria using CTE/MRE.
Scaffold-Free Spheroids with Two-Dimensional Heteronano-Layers (2DHNL) Enabling Stem Cell and Osteogenic Factor Codelivery for Bone Repair
Liu, Xifeng , Gaihre, Bipin , Park, Sungjo , Elder, Benjamin D. , Lu, Lichun , Li, Linli , Lu, Lichun , Li, Yong, Terzic, André

ACS Nano | January 24, 2022 | Volume: 16 | Issue: 2 | Pages: 2741-2755

10.1021/acsnano.1c09688 | PMID 35072461 Get It

Correction: An International Adult Guideline for Making Clozapine Titration Safer by Using Six Ancestry-Based Personalized Dosing Titrations, CRP, and Clozapine Levels
León, José de , Schoretsanitis, Georgios , Smith, Robert L. , Molden, Espen , Solismaa, Anssi , Seppälä, Niko , Kopeček, Miloslav , Švancer, Patrik , Olmos, I. Cánovas , Ricciardi, Carina , Iglesias-Alonso, Ana , Ruan, Can‐Jun , Wang, Chuanyue , Wang, Gang , Tang, Yi‐lang , Kim, Yong Sik , Kim, Se Hyun , Jung–Cook, Helgi , Nielsen, Jimmi , Verdoux, Hélène , Quilès, Clélia , Cohen, Dan , Schulte, Peter F.J. , Chopra, Nitin , McCollum, Betsy , Shelton, Charles , Cotes, Robert O. , Kaithi, Arun R., Farooq, Saeed , Ng, Chee H. , Bilbily, John , Lana, Fernando , Rădulescu, Flavian Ștefan , Seifritz, Erich , Every‐Palmer, Susanna , Bebawi, Emmanuel , Kelly, Deanna L. , Lazáry, Judit , Torres, Rafael , Yécora, Agustín, Berardis, Domenico De , Adebayo, Richard A. , Fountoulakis, Konstantinos Ν. , Ayub, Muhammad , Silva, Alzira , Bonelli, Raphael M., Crespo‐Facorro, Benedicto , Temmingh, Henk , Decloedt, Eric , Pedro, Maria Rosel , Gründer, Gerhard , Čelofiga, Andreja , Ristić, Dragana Ignjatović , Elkis, Hélio , Siskind, Dan , Masmoudi, R. , Saffian, Shamin Mohd , Buckley, P.F. , Freudenreich, Oliver , Müller, Daniel J. , de Leon, Jose , Olmos, Ismael , Iglesias-Garcia, Celso , Iglesias-Alonso, Ana , Spina, Edoardo , Ruan, Can-Jun , Wang, Chuan-Yue , Tang, Yi-Lang , Lin, Shih-Ku , Lane, Hsien-Yuan , Kim, Yong Sik , Kim, Se Hyun , Rajkumar, Anto P , González-Esquivel, Dinora F , Jung-Cook, Helgi , Baptista, Trino , Rohde, Christopher , Nielsen, Jimmi , Verdoux, Hélène , Quiles, Clelia , Sanz, Emilio J , De Las Cuevas, Carlos , Cohen, Dan , Schulte, Peter F J , Ertuğrul, Aygün , Anıl Yağcıoğlu, A Elif , Chopra, Nitin , McCollum, Betsy , Shelton, Charles , Cotes, Robert O , Kane, John M , Farooq, Saeed , Ng, Chee H , Bilbily, John , Hiemke, Christoph , López-Jaramillo, Carlos , McGrane, Ian , Lana, Fernando , Eap, Chin B , Every-Palmer, Susanna , Bousman, Chad A , Bebawi, Emmanuel , Bhattacharya, Rahul , Kelly, Deanna L , Otsuka, Yuji , Lazary, Judit , Motuca, Mariano , Chan, Sherry K W , Zolezzi, Monica , Ouanes, Sami , De Berardis, Domenico , Grover, Sandeep , Procyshyn, Ric M , Adebayo, Richard A , Kirilochev, Oleg O , Soloviev, Andrey , Fountoulakis, Konstantinos N , Wilkowska, Alina , Cubała, Wiesław J , Ayub, Muhammad , Silva, Alzira , Villagrán-Moreno, José M , Crespo-Facorro, Benedicto , Temmingh, Henk , Decloedt, Eric , Pedro, Maria R , Takeuchi, Hiroyoshi , Tsukahara, Masaru , Gründer, Gerhard , Sagud, Marina , Celofiga, Andreja , Ignjatovic Ristic, Dragana , Ortiz, Bruno B , Elkis, Helio , Pacheco Palha, António J , LLerena, Adrián , Fernandez-Egea, Emilio , Siskind, Dan , Weizman, Abraham , Masmoudi, Rim , Mohd Saffian, Shamin , Leung, Jonathan G , Buckley, Peter F , Marder, Stephen R , Citrome, Leslie , Freudenreich, Oliver , Correll, Christoph Ulrich , Müller, Daniel J , Kopecek, Miloslav , Schoretsanitis, Georgios , García, Celso Iglesias , Rajkumar, Anto P. , González‐Esquivel, Dinora F. , Rohde, Christopher , Sanz, Emílio J. , Cuevas, Carlos De las , Yağcıoğlu, A. Elif Anıl , Kane, John M. , Hiemke, Christoph , López‐Jaramillo, Carlos , McGrane, Ian R. , Arrojo, Manuel , Bousman, Chad , Bhattacharya, Rahul , Motuca, Mariano , Chan, Sherry Kit Wa , Кирилочев, О.О. , Soloviev, A. G. , Wilkowska, Alina , Cubała, Wiesław Jerzy , Tsukahara, Masaru , Ortiz, Bruno Bertolucci , LLerena, Adrián , Leung, Jonathan G. , Citrome, Leslie

Pharmacopsychiatry | January 20, 2022 | Volume: 55 | Issue: 02 | Pages: e1-e1

10.1055/a-1737-1527 | PMID 35052001 Get It

Gender-Inclusive Fellowship Naming and Equity, Diversity, and Inclusion in Radiology: An Analysis of Radiology Department Websites in Canada and the United States
Yan, Tyler D. , Mak, Lauren E. , Carroll, Evelyn F. , Khosa, Faisal , Yong‐Hing, Charlotte J.

Canadian Association of Radiologists Journal | January 12, 2022 | Volume: 73 | Issue: 3 | Pages: 473-477

10.1177/08465371211066104 | PMID 35019762 Get It

Purpose: Transgender and gender non-binary (TGNB) individuals face numerous inequalities in healthcare and there is substantial work to be done in fostering TGNB culturally competent care in radiology. A radiology department’s online presence and use of gender-inclusive language are essential in promoting an environment of equity, diversity, and inclusion (EDI). The naming of radiology fellowships and continuing medical education (CME) courses with terminology such as “Women’s Imaging” indicates a lack of inclusivity to TGNB patients and providers, which could result in suboptimal patient care. Methods: We conducted a cross-sectional analysis of all institutions in Canada and the United States (US) offering training in Breast Imaging, Women’s Imaging, or Breast and Body Imaging. Data was collected from each institution’s radiology department website pertaining to fellowship names, EDI involvement, and CME courses. Results: 8 Canadian and 71 US radiology fellowships were identified. 75% of Canadian and 90% of US fellowships had gender-inclusive names. One (12.5%) Canadian and 29 (41%) US institutions had EDI Committees mentioned on their websites. Among institutions publicly displaying CME courses about breast/body or women’s imaging, gender-inclusive names were used in only 1 (25%) of the Canadian CME courses, compared to 81% of the US institutions. Conclusions: Most institutions in Canada and the US have gender-inclusive names for their radiology fellowships pertaining to breast and body imaging. However, there is much opportunity to and arguably the responsibility for institutions in both countries to increase the impact and visibility of their EDI efforts through creation of department-specific committees and CME courses.
A Phase 1 study of GDC‐0134, a dual leucine zipper kinase inhibitor, in ALS
Katz, Jonathan, Cudkowicz, Merit , Genge, Angela , Oskarsson, Björn , Hains, Avis B., Galanter, Joshua , Burgess, Braydon L., Kerchner, Geoffrey A. , Yeh, Felix L. , Ghosh, Arundhati Sengupta, Cheeti, Sravanthi , Brooks, Logan , Honigberg, Lee , Couch, Jessica A. , Rothenberg, Michael E. , Brunstein, Flávia, Sharma, Khema R., Berg, Leonard van den , Glass, Jonathan D. , Glass, Jonathan D , Oskarsson, Björn , Cudkowicz, Merit E , Rothstein, Jeffrey D. , Chen, Chen , Cho, Yong‐Yeon , Brooks, Logan, Berry, James D.

Annals of Clinical and Translational Neurology | January 11, 2022 | Volume: 9 | Issue: 1 | Pages: 50-66

10.1002/acn3.51491 | PMID 35014217 Get It

AbstractObjectiveDual leucine zipper kinase (DLK), which regulates the c‐Jun N‐terminal kinase pathway involved in axon degeneration and apoptosis following neuronal injury, is a potential therapeutic target in amyotrophic lateral sclerosis (ALS). This first‐in‐human study investigated safety, tolerability, and pharmacokinetics (PK) of oral GDC‐0134, a small‐molecule DLK inhibitor. Plasma neurofilament light chain (NFL) levels were explored in GDC‐0134‐treated ALS patients and DLK conditional knockout (cKO) mice.MethodsThe study included placebo‐controlled, single and multiple ascending‐dose (SAD; MAD) stages, and an open‐label safety expansion (OLE) with adaptive dosing for up to 48 weeks.ResultsForty‐nine patients were enrolled. GDC‐0134 (up to 1200 mg daily) was well tolerated in the SAD and MAD stages, with no serious adverse events (SAEs). In the OLE, three study drug‐related SAEs occurred: thrombocytopenia, dysesthesia (both Grade 3), and optic ischemic neuropathy (Grade 4); Grade ≤2 sensory neurological AEs led to dose reductions/discontinuations. GDC‐0134 exposure was dose‐proportional (median half‐life = 84 h). Patients showed GDC‐0134 exposure‐dependent plasma NFL elevations; DLK cKO mice also exhibited plasma NFL compared to wild‐type littermates.InterpretationThis trial characterized GDC‐0134 safety and PK, but no adequately tolerated dose was identified. NFL elevations in GDC‐0134‐treated patients and DLK cKO mice raised questions about interpretation of biomarkers affected by both disease and on‐target drug effects. The safety profile of GDC‐0134 was considered unacceptable and led to discontinuation of further drug development for ALS. Further work is necessary to understand relationships between neuroprotective and potentially therapeutic effects of DLK knockout/inhibition and NFL changes in patients with ALS.