Citations

Mayo Clinic

Clear

145 citation(s) found for "Algeciras‐Schimnich, Alicia".

Laboratory Services for Managing Thyroid Disease: Different and Common Viewpoints of American Thyroid Association Members and of Members of the Endocrine Division of the American Association for Clinical Chemistry
Grebe, Stefan K., A, on behalf of the American Thyroid, Grebe, Stefan K G, Algeciras‐Schimnich, Alicia

Thyroid | November 8, 2017 | Volume: 27 | Issue: 12 | Pages: 1583-1585

10.1089/thy.2017.0387 | PMID 29113554 Get It

United States and European Multicenter Prospective Study for the Analytical Performance and Clinical Validation of a Novel Sensitive Fully Automated Immunoassay for Calcitonin
Kahaly, George J. , Davis, Thomas E., Diana, Tanja, Feldkamp, Joachim , Karger, Stefan, Lupo, Mark A. , Raue, Friedhelm , Ringel, Matthew D. , Sipos, Jennifer A. , Kratzsch, Jüergen, Algeciras‐Schimnich, Alicia , König, J. , Ringel, Matthew D

Clinical Chemistry | July 7, 2017 | Volume: 63 | Issue: 9 | Pages: 1489-1496

10.1373/clinchem.2016.270009 | PMID 28687633 Get It

Abstract BACKGROUND The objective of this study is the validation and proof of clinical relevance of a novel electrochemiluminescence immunoassay (ECLIA) for the determination of serum calcitonin (CT) in patients with medullary thyroid carcinoma (MTC) and in different diseases of the thyroid and of calcium homeostasis. METHODS This was a multicenter prospective study on basal serum CT concentrations performed in 9 US and European referral institutions. In addition, stimulated CT concentrations were measured in 50 healthy volunteers after intravenous calcium administration (2.5 mg/kg bodyweight). RESULTS In total, 1929 patients and healthy controls were included. Limits of blank, detection, and quantification for the ECLIA were 0.3, 0.5, and 1 ng/L, respectively. Highest intra- and interassay coefficients of variation were 7.4% (CT concentration, 0.8 ng/L) and 7.0% (1.1 ng/L), respectively. Medians (interval) of serum CT concentrations in 783 healthy controls were 0.8 ng/L (<0.5–12.7) and 3 ng/L (<0.5–18) for females and males, respectively (97.5th percentile, 6.8 and 11.6 ng/L, respectively). Diagnostic sensitivity and specificity were 100%/97.1% and 96.2%/96.4%, for female/males, respectively. Patients (male/female) with primary hyperparathyroidism, renal failure, and neuroendocrine tumors showed CT concentrations >97.5th percentile in 33%/4.7%, 18.5%/10%, and 8.3%/12%, females/males, respectively. Peak serum CT concentrations were reached 2 min after calcium administration (161.7 and 111.8 ng/L in males and females, respectively; P < 0.001). CONCLUSIONS Excellent analytical performance, low interindividual variability, and low impact of confounders for increased CT concentrations in non-MTC patients indicate that the investigated assay has appropriate clinical utility. Calcium-stimulated CT results suggest good test applicability owing to low interindividual variability.
55: Evaluation of the Clinical and Laboratory Standards Institute EP26-A Guideline: A Protocol for Reagent Lot-to-Lot Verification
Katzman, Brooke M. , Ness, Karl M. , Algeciras‐Schimnich, Alicia

American Journal of Clinical Pathology | February 3, 2017 | Volume: 143 | Issue: suppl_1 | Pages: A028-A028

10.1093/ajcp/143.suppl1.029 Get It

Commentary
Algeciras‐Schimnich, Alicia

Clinical Chemistry | September 28, 2016 | Volume: 62 | Issue: 10 | Pages: 1316-1317

10.1373/clinchem.2016.256081 | PMID 27683592 Get It

Detection of IGF-1 Protein Variants by Use of LC-MS with High-Resolution Accurate Mass in Routine Clinical Analysis
Hines, Jolaine, Ketha, Hemamalini , Grebe, Stefan K., Milošević, Dragana , Taylor, Robert L. , Algeciras‐Schimnich, Alicia , Singh, Ravinder

Clinical Chemistry | April 28, 2015 | Volume: 61 | Issue: 7 | Pages: 990-991

10.1373/clinchem.2014.234799 | PMID 25922441 Get It

Combinations of biomarkers and Milan criteria for predicting hepatocellular carcinoma recurrence after liver transplantation
Chaiteerakij, Roongruedee , Zhang, Xiaodan , Addissie, Benyam D., Harmsen, William S. , Theobald, Paul J., Peters, Brian E., Balsanek, Joseph G., Ward, Melissa M., Giama, Nasra H., Moser, Catherine D., Oseini, Abdul M., Umeda, Naoki, Venkatesh, Sudhakar K. , Harnois, Denise M. , Satomura, Shinji , Snyder, Melissa R. , Therneau, Terry M. , Roberts, Lewis R. , Chaiteerakij, Roongruedee , Mohamed, Essa A. , Charlton, Michael , Yamada, Hiroyuki , Algeciras‐Schimnich, Alicia , Roberts, Lewis R , Venkatesh, Sudhakar K

Liver Transplantation | March 17, 2015 | Volume: 21 | Issue: 5 | Pages: 599-606

10.1002/lt.24117 | PMID 25789635 Get It

Growing evidence suggests that pretransplant alpha‐fetoprotein (AFP) predicts outcomes of hepatocellular carcinoma (HCC) patients treated with liver transplantation. We aimed to determine whether pretransplant AFP, Lens culinaris agglutinin‐reactive alpha‐fetoprotein (AFP‐L3), and des‐gamma‐carboxyprothrombin (DCP) predicted HCC recurrence after transplantation. A retrospective cohort study of 313 HCC patients undergoing transplantation between 2000 and 2008 was conducted, and 48 (15.3%) developed recurrence during a median follow‐up of 90.8 months. The 127 patients with available serum drawn before transplantation were included; they included 86 without recurrence and 41 with recurrence. Serum was tested for AFP, AFP‐L3%, and DCP in a blinded fashion with the μTASWako i30 immunoanalyzer. All biomarkers were significantly associated with HCC recurrence. The hazard ratios (HRs) were 3.5 [95% confidence interval (CI), 1.9‐6.7; P < 0.0001] for DCP ≥ 7.5 ng/mL and 2.8 (95% CI, 1.4‐5.4; P = 0.002) for AFP ≥ 250 ng/mL. The HR increased to 5.2 (95% CI, 2.3‐12.0; P < 0.0001) when AFP ≥ 250 ng/mL and DCP ≥7.5 ng/mL were considered together. When they were combined with the Milan criteria, the HR increased from 2.6 (95% CI, 1.4‐4.7; P = 0.003) for outside the Milan criteria to 8.6 (95% CI, 3.0‐24.6; P < 0.0001) for outside the Milan criteria and AFP ≥ 250 ng/mL and to 7.2 (95% CI, 2.8‐18.1; P < 0.0001) for outside the Milan criteria and DCP ≥7.5 ng/mL. Our findings suggest that biomarkers are useful for predicting the risk of HCC recurrence after transplantation. Using both biomarkers and the Milan criteria may be better than using the Milan criteria alone in optimizing the decision of liver transplantation eligibility. Liver Transpl 21:599–606, 2015. © 2015 AASLD.
Usefulness of a Thyroglobulin Liquid Chromatography–Tandem Mass Spectrometry Assay for Evaluation of Suspected Heterophile Interference
Netzel, Brian C., Grebe, Stefan K., Grebe, Stefan K G, Algeciras‐Schimnich, Alicia

Clinical Chemistry | May 9, 2014 | Volume: 60 | Issue: 7 | Pages: 1016-1018

10.1373/clinchem.2014.224816 | PMID 24812415 Get It

Glycoprotein 120 Binding to CXCR4 Causes p38-Dependent Primary T Cell Death That Is Facilitated by, but Does Not Require Cell-Associated CD4
Trushin, Sergey A., Algeciras-Schimnich, Alicia , Vlahakis, Stacey R., Bren, Gary D., Warren, Sarah, Schnepple, David, Badley, Andrew D. , Badley, Andrew D

The Journal of Immunology | April 18, 2014 | Volume: 178 | Issue: 8 | Pages: 4846-4853

10.4049/jimmunol.178.8.4846 | PMID 17404265 Get It

Abstract HIV-1 infection causes the depletion of host CD4 T cells through direct and indirect (bystander) mechanisms. Although HIV Env has been implicated in apoptosis of uninfected CD4 T cells via gp120 binding to either CD4 and/or the chemokine receptor 4 (CXCR4), conflicting data exist concerning the molecular mechanisms involved. Using primary human CD4 T cells, we demonstrate that gp120 binding to CD4 T cells activates proapoptotic p38, but does not activate antiapoptotic Akt. Because ligation of the CD4 receptor alone or the CXCR4 receptor alone causes p38 activation and apoptosis, we used the soluble inhibitors, soluble CD4 (sCD4) or AMD3100, to delineate the role of CD4 and CXCR4 receptors, respectively, in gp120-induced p38 activation and death. sCD4 alone augments gp120-induced death, suggesting that CXCR4 signaling is principally responsible. Supporting that model, AMD3100 reduces death caused by gp120 or by gp120/sCD4. Finally, prevention of gp120-CXCR4 interaction with 12G5 Abs blocks p38 activation and apoptosis, whereas inhibition of CD4-gp120 interaction with Leu-3a has no effect. Consequently, we conclude that gp120 interaction with CXCR4 is required for gp120 apoptotic effects in primary human T cells.
Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions
Algeciras‐Schimnich, Alicia , Bruns, David E., Boyd, James C. , Bryant, Sandra C. , Fortune, Kristin La , Grebe, Stefan K., Algeciras-Schimnich, Alicia

Clinical Chemistry | April 17, 2013 | Volume: 59 | Issue: 8 | Pages: 1187-1194

10.1373/clinchem.2013.205070 | PMID 23592508 Get It

BACKGROUND Maintaining consistency of results over time is a challenge in laboratory medicine. Lot-to-lot reagent changes are a major threat to consistency of results. METHODS For the period October 2007 through July 2012, we reviewed lot validation data for each new lot of insulin-like growth factor 1 (IGF-1) reagents (Siemens Healthcare Diagnostics) at Mayo Clinic, Rochester, MN, and the University of Virginia, Charlottesville, VA. Analyses of discarded patient samples were used for comparison of lots. For the same period, we determined the distributions of reported patient results for each lot of reagents at the 2 institutions. RESULTS Lot-to-lot validation studies identified no reagent lot as significantly different from the preceding lot. By contrast, significant lot-to-lot changes were seen in the means and medians of 105 668 reported patient IGF-I results during the period. The frequency of increased results increased nearly 2-fold to a high of 17%, without detectable changes in the underlying patient demographics. Retrospective statistical analysis indicated that lot-to-lot comparison protocols were underpowered and that validation studies for this assay required testing &gt;100 samples to achieve 90% power to detect reagent lots that would significantly alter the distributions of patient results. CONCLUSIONS The number of test samples required for adequate lot-to-lot validation protocols is high and may be prohibitively large, especially for low-volume or complex assays. Monitoring of the distributions of patient results has the potential to detect lot-to-lot inconsistencies relatively quickly. We recommend that manufacturers implement remote monitoring of patient results from analyzers in multiple institutions to allow rapid identification of between-lot result inconsistency.
The Roche Elecsys and Siemens-Centaur Thyroglobulin Autoantibody Assays Show Comparable Clinical Performance to the Recently Unavailable Beckman-Coulter Access Thyroglobulin Autoantibody Assay in Identifying Samples with Potentially False-Low Thyroglobulin
Lasho, Michael A., Ness, Karl M. , Cheryk, Lynn A., Grebe, Stefan K., Algeciras‐Schimnich, Alicia

Thyroid® | June 28, 2011 | Volume: 21 | Issue: 7 | Pages: 813-814

10.1089/thy.2011.0158 | PMID 21707436 Get It