Back to Authors

Algeciras-Schimnich, Alicia

0000-0002-4455-6217

Mayo Clinic

Mayo Clinic

Citations 25

Clinical Factors Associated With Discordant Plasma P-Tau217 and Established Alzheimer Disease Biomarkers
Shir, Dror , Algeciras-Schimnich, Alicia , Piura, Yoav D , Bornhorst, Joshua , Figdore, Daniel J , Lachner, Christian , Graff-Radford, Neill R , Day, Gregory S

Neurology | October 1, 2026 | Volume: 107 | Issue: 8 | Pages: No page available

10.1212/wnl.0000000000218591 Get It

Modelling the temporal evolution of plasma p-tau217, amyloid PET, tau PET and cognition
Cogswell, Petrice M, Therneau, Terry M, Hu, Mingzhao, Griswold, Michael E, Wiste, Heather J. , Machulda, Mary M., Braunstein, Joel B. , West, Tim, Verghese, Philip B. , Graff-Radford, Jonathan, Algeciras-Schimnich, Alicia, Lowe, Val J, Schwarz, Christopher G, Senjem, Matthew L, Gunter, Jeffrey L. , Knopman, David S, Vemuri, Prashanthi, Petersen, Ronald C, Jr, Clifford R Jack, Cogswell, Petrice M. , Cogswell, Petrice M , Lundt, Emily S. , Graff-Radford, Jonathan , Algeciras-Schimnich, Alicia , Schwarz, Christopher G , Knopman, David S. , Vemuri, Prashanthi , Jack, Clifford R , Lundt, Emily S , Therneau, Terry M. , Hu, Mingzhao, Griswold, Michael , Machulda, Mary M. , Stricker, Nikki H. , West, Tim , Graff‐Radford, Jonathan , Algeciras‐Schimnich, Alicia , Lowe, Val J. , Schwarz, Christopher G. , Senjem, Matthew L. , Knopman, David S. , Vemuri, Prashanthi , Petersen, Ronald C. , Jack, Clifford R.

Brain | February 24, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/brain/awag075 Get It

Abstract Associations of Alzheimer’s disease biomarker progression with cognitive decline are important to inform patient prognosis. Of particular interest is how newly available plasma biomarkers evolve relative to cognitive decline. The goals of this work are to measure how much earlier versus later an individual’s progression on plasma and PET Alzheimer’s disease biomarkers is associated with earlier versus later cognitive progression and to estimate the average timeline of progression of these processes in the population. In this cohort study of 2369 Mayo Clinic Study of Aging (MCSA) and 1591 Alzheimer’s Disease Neuroimaging Initiative (ADNI) participants, we fit non-linear mixed-effects models to estimate how much earlier versus later each individual progresses on plasma phosphorylated tau (p-tau)217, amyloid PET, tau PET and auditory verbal learning test (AVLT) sum of trials relative to the population mean (individual adjustment), the associations of these individual adjustments among biomarker pairs and how covariates affect the timing of biomarker progression. The association of individual adjustments implies mechanistic associations and the amount of variability in cognitive decline accounted for by each biomarker. By applying cut-off points, we also estimated the relative timing that these biomarkers become abnormal in the population. Associations of individual adjustments were moderate between all biomarkers and AVLT (R = 0.38–0.47) in the MCSA and stronger (R = 0.74–0.81) in ADNI; plasma p-tau217 accounted for 16% of the variability in timing of AVLT decline in the MCSA and 64% in ADNI. APOE ɛ4 carriership was associated with earlier biomarker progression. AVLT became abnormal after the biomarkers up to age 90, after which AVLT was estimated to become abnormal prior to tau biomarkers. The association of the timing of plasma and PET Alzheimer’s disease biomarker progression with cognitive decline was modest in the MCSA population-based sample and stronger in the Alzheimer’s disease-enriched ADNI cohort. The timing of plasma p-tau217 progression explained a similar degree of variability in AVLT progression as amyloid PET, supporting its utility as a marker of disease progression. The estimated temporal ordering of biomarkers and cognitive abnormality was as anticipated (amyloid, tau, cognition) up to the age of 90, beyond which AVLT was estimated to become abnormal prior to tau biomarkers, likely related to the effects of non-Alzheimer’s disease co-pathologies.
Current State and Needs of Clinical Laboratories in Latin America: A Cross-Country Assessment
Molinelli, Alejandro R. , Palavecino, Elizabeth , Jara-Aguirre, José, Cosby, Kerry, Targowski, Allison, Goldsmith, Barbara, Sierra-Amor, Rosa Isabel, García, Juan D, Algeciras-Schimnich, Alicia, Zabaleta, Eugenio H, Luzzi, Veronica, Colón-Franco, Jessica M , Algeciras-Schimnich, Alicia , Jara-Aguirre, Jose C., Cosby, Kerry, Targowski, Allison, Algeciras‐Schimnich, Alicia , Luzzi, Verónica

The Journal of Applied Laboratory Medicine | February 4, 2026 | Volume: 11 | Issue: 4 | Pages: 927-938

10.1093/jalm/jfag019 Get It

Abstract The Association for Diagnostics & Laboratory Medicine (ADLM) aims to improve health by providing education to laboratory scientists worldwide. Different regions of the world face unique challenges shaped by their national and regional contexts. However, the needs of clinical laboratories worldwide remain largely understudied. To address this gap, we conducted a comprehensive needs assessment survey among laboratory professionals in the Latin American region. The survey was distributed to over 2708 individuals across Latin American countries and yielded 148 responses. Most respondents were from urban areas (74%) and worked in private hospital laboratories (45%), with microbiology (25%) and chemistry (23%) identified as the most common specialties. Key findings include continuing education as the top challenge, identified by 59% of respondents, with a predominant preference for virtual learning formats (83%), though not exclusively; 50% also identified a preference for in-person learning. Other challenges, such as staff shortages, lack of equipment and funding, were selected by 30% to 36% of respondents, whereas regulatory oversight and quality management were less frequently identified as priorities. To contextualize the survey findings, we conducted interviews with laboratory professionals in the region. Common themes included resource and technology constraints, uneven implementation of quality standards, and the need for collaboration between government and professional organizations to bridge gaps in practice. This assessment highlights the need for targeted educational interventions to address the distinct challenges faced by Latin American laboratories. Addressing these gaps in continued education, fostering collaboration, and engaging stakeholders in the region offer a roadmap to strengthening laboratory services and health outcomes.
False positive plasma p‐tau217 results associated with heterophilic antibody interference: A potential clinical pitfall
Theobald, J Paul, Kian, Susan Ashrafzadeh, Algeciras-Schimnich, Alicia , Ashrafzadeh Kian, Susan, Bornhorst, Joshua A. , Algeciras‐Schimnich, Alicia , Theobald, J. Paul, Figdore, Daniel J. , Ashrafzadeh‐Kian, Susan , Bornhorst, Joshua

Alzheimer's & Dementia | December 29, 2025 | Volume: 21 | Issue: 12 | Pages: No page available

10.1002/alz.71045 Get It

Abstract INTRODUCTION Plasma phosphorylated tau at threonine 217 (p‐tau217) has emerged as one of the most promising blood‐based biomarkers for Alzheimer's disease (AD). While rare, heterophilic antibodies (HAb) are a persistent potential confounding factor in immunoassays. METHODS Potential HAb interference in the Lumipulse G pTau217 assay in samples exhibiting concentrations > 10 pg/mL were investigated. Samples were subjected to HAb blocking reagent (HBT), and in some cases, polyethylene glycol (PEG) precipitation and serial dilutions. RESULTS In 14 of the 15 suspected HAb cases, HBT treatment greatly reduced measured p‐tau217 concentrations. and in one of three specimens selected for further investigation, reduced Aβ42 concentrations PEG precipitation in the three selected samples also reduced p‐tau217 concentrations, while serial dilution yielded mixed effects. Control specimens were unaffected by sample treatment or dilutions. DISCUSSION HAb may result in falsely elevated p‐tau217 and p‐tau217/Aβ42 ratio. HAb interference should be considered in cases of unusually high p‐tau217 concentrations prior to clinical interpretation. Highlights Potential heterophile antibody (HAb) interference in the Lumipulse p‐tau217 immunoassay was investigated. Investigation was performed using HAb blocking reagent, and in some cases also using PEG precipitation . Patients with p‐tau217 concentrations > 10 pg/mL exhibited positive HAb interference in 14 of 15 cases. HAb interference can lead to falsely positive p‐tau217/Aβ42 ratios.
Predictive Value of Plasma Biomarkers in Tau‐ PET Transitions
Graff‐Radford, Jonathan , Syrjanen, Jeremy A. , Vemuri, Prashanthi , Lowe, Val J. , Schwarz, Christopher G. , Wiste, Heather J. , Kremers, Walter K. , Binette, Alexa Pichet , Stomrud, Erik , Petersen, Ronald C. , Algeciras-Schimnich, Alicia , Pichet Binette, Alexa , Knopman, David S. , Petersen, Ronald C , Hansson, Oskar , Schwarz, Christopher G , Vemuri, Prashanthi , Stomrud, Erik , Kremers, Walter K , Algeciras‐Schimnich, Alicia , Smith, Ruben , Mattsson, Niklas , Palmqvist, Sebastian , Knopman, David S. , Cogswell, Petrice M. , Hansson, Oskar , Jack, Clifford R.

Annals of Neurology | September 10, 2025 | Volume: 98 | Issue: 6 | Pages: 1249-1260

10.1002/ana.78003 Get It

Objective The objective of this study was to determine the predictive value of amyloid‐positron emission tomography (PET) versus the plasma ratio of phosphorylated tau at threonine 217 (p‐tau217) to non‐phosphorylated tau217 (%p‐tau217) for tau‐PET transitions (T− to T+). The added value of combining plasma amyloid‐β 42 and amyloid‐β 40 (Aβ42/40) and %p‐tau217 into an amyloid probability score (APS2) was also assessed. Methods Mayo Clinic Study of Aging (MCSA) participants had plasma markers measured at via mass spectrometry (MS), an amyloid‐PET scan, and a tau‐PET (meta‐temporal region of interest [ROI]) negative scan (standardized uptake value ratio [SUVR] <1.29) at the index (baseline) date, along with one or more follow‐up tau‐PET scans. The BioFINDER‐2 cohort was used for validation. Cox proportional hazards models adjusted for age, sex, and apolipoprotein ( APOE ) ε4 were used to assess predictors, with scaling to the interquartile range (IQR) for comparability of hazard ratios (HR). Results Among 255 tau‐PET negative MCSA participants (median age: 71.9 years), 37 converted to tau‐PET positive (median follow‐up time: 3.81 years). Higher %p‐tau217 (HR: 1.52 [95% CI: 1.28–1.80]), amyloid‐PET centiloid (HR: 1.47 [95% CI: 1.20–1.79]), and APS2 (HR: 1.62 [95% CI: 1.22–2.16]) predicted tau‐PET conversion. However, Aβ42/40 (HR: 0.94 [95% CI: 0.54–1.66]) was not associated with tau‐PET conversion. In the BioFINDER‐2 cohort (605 tau‐negative, median age: 70.2), 33 converted to tau‐positive (median follow‐up time: 2 years), with higher %p‐tau217 (HR: 1.80 [95% CI: 1.50–2.17]), amyloid‐PET centiloid (HR: 2.29 [95% CI: 1.77–2.97]), and lower Aβ42/40 (HR: 2.38 [95% CI: 1.17–4.83]) predicting conversion. Interpretation In two cohorts, %p‐tau217 was associated with tau‐PET conversion, comparable to amyloid‐PET. APS2 also predicted conversion in the MCSA cohort, whereas Aβ42/40 predicted conversion in the BioFINDER‐2 cohort, which had more individuals with cognitive impairment. ANN NEUROL 2025;98:1249–1260
Diagnostic performance of plasma p‐tau217 and Aβ42/40 biomarkers in the outpatient memory clinic
Piura, Yoav , Lachner, Christian, Bornhorst, Joshua A. , Algeciras‐Schimnich, Alicia , Graff‐Radford, Neill R., Day, Gregory S. , Algeciras-Schimnich, Alicia , Piura, Yoav D, Figdore, Daniel J. , Day, Gregory S , Bornhorst, Joshua , Lachner, Christian , Graff‐Radford, Neill R.

Alzheimer's & Dementia | June 6, 2025 | Volume: 21 | Issue: 6 | Pages: No page available

10.1002/alz.70316 Get It

Abstract INTRODUCTION Plasma biomarkers of Alzheimer's disease (AD) represent accessible alternatives to positron emission tomography (PET) and cerebrospinal fluid (CSF)‐based biomarkers in well‐characterized cohorts. It remains to be determined whether performance is maintained in outpatient clinics comprised of patients with multiple causes of cognitive impairment. METHODS Plasma phosphorylated tau217 (p‐tau217) and amyloid beta (Aβ) 42/40 were measured in 509 patients evaluated in a tertiary‐care memory clinic. Biomarker performance was compared across diagnoses, referencing established cutpoints for positive and negative biomarkers. RESULTS Plasma p‐tau217 distinguished patients with diagnoses of symptomatic AD with 95% sensitivity and 82% specificity. Integration of Aβ42 measurements (p‐tau217/Aβ42) incrementally improved specificity (86%). Plasma p‐tau217 and p‐tau217/Aβ42 concentrations closely associated with established CSF biomarkers of AD (area under the curve [AUC]: 0.94 and 0.96, respectively). Reduced kidney function associated with elevated plasma p‐tau217 and p‐tau217/Aβ42 concentrations in patients without AD (referencing CSF biomarkers). DISCUSSION Plasma p‐tau217 and p‐tau217/Aβ42 concentrations demonstrated robust diagnostic performance in a heterogeneous clinical cohort; interpretation requires consideration of kidney function. Highlights Plasma phosphorylated tau217 (p‐tau217) reliably identified clinic patients with Alzheimer's disease. A two‐cutpoint strategy yielded definitive results in 86% of patients. Integration of plasma amyloid beta (Aβ; p‐tau217/Aβ42) minimally improved diagnostic performance. Plasma p‐tau217 levels were increased in patients with kidney dysfunction.
Differences in Alzheimer's disease blood biomarker stability: Implications for the use of tau/amyloid ratios
Schuder, Bethany J., Ashrafzadeh‐Kian, Susan , Gronquist, Tina, Bornhorst, Joshua A. , Algeciras‐Schimnich, Alicia , Algeciras-Schimnich, Alicia , Figdore, Daniel J. , Ashrafzadeh-Kian, Susan, Bornhorst, Joshua

Alzheimer's & Dementia | May 1, 2025 | Volume: 21 | Issue: 4 | Pages: No page available

10.1002/alz.70173 Get It

AbstractINTRODUCTIONWe compare the stability of phosphorylated tau (p‐tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p‐tau217/Aβ42 at different storage temperatures.METHODSTen ethylenediaminetetraacetic acid–plasma sample aliquots stored at frozen, refrigerated, and ambient temperatures were tested at various timepoints up to 30 days. The mean percent change from baseline was calculated.RESULTSAβ42 and Aβ40 concentrations decreased by >15% after 6 hours at ambient temperature and after 24 hours refrigerated, while p‐tau217 remained stable over 72 hours with < 10% deviation from baseline at either storage temperature. The Aβ42/40 ratio remained relatively constant as each analyte concentration decreased concurrently, while the p‐tau217/Aβ42 ratio deviated from baseline over time. All biomarkers were stable up to 30 days frozen.DISCUSSIONDifferences in the stability of Aβ42 and p‐tau217 may lead to altered p‐tau217/Aβ42 ratio results if samples are not handled properly during the pre‐analytical testing phase. Ideally, samples should be frozen promptly and sent to the laboratory frozen.Highlights Plasma phosphorylated tau (p‐tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p‐tau217/Aβ42 stability was assessed. P‐tau217 was stable, but Aβ42 and Aβ40 started decreasing by 6 hours at ambient temperature. The analyte stability differences led to falsely increased p‐tau217/Aβ42 ratios. Increases > 15% were seen in p‐tau217/Aβ42 after 6 hours at ambient temperature or 24 hours at 4°C.
Performance of Dehydroepiandrosterone Sulfate and Baseline Cortisol in Assessing Adrenal Insufficiency
Han, Ashley J , Suresh, Malavika, Gruber, Lucinda , Achenbach, Sara J., Atkinson, Elizabeth J. , Gruber, Lucinda M , Algeciras-Schimnich, Alicia , Bancos, Irina , Algeciras‐Schimnich, Alicia , Bancos, Irina

The Journal of Clinical Endocrinology & Metabolism | December 10, 2024 | Volume: 110 | Issue: 9 | Pages: e3117-e3124

10.1210/clinem/dgae855 Get It

Abstract Context Diagnosing adrenal insufficiency (AI) often requires complex testing, which can be time-consuming and expensive. Dehydroepiandrosterone sulfate (DHEAS) is a promising marker of hypothalamic-pituitary-adrenal axis function; however, its diagnostic performance has not yet been evaluated in a large-scale study. Objective Evaluate the performance of DHEAS and baseline cortisol in assessing AI. Design Single-center retrospective cohort study. Setting Referral center. Patients Adults who underwent cosyntropin stimulation testing (CST) between 2005 and 2023 and had DHEAS measured within 3 months prior to CST. Main Outcome Measures Area under receiver operating characteristic curve (AUROC) for DHEAS and baseline cortisol. Prevalence of AI based on various DHEAS and baseline cortisol concentrations. Results Among 1135 patients, 195 (17.2%) had AI. Both baseline cortisol and DHEAS independently had good diagnostic performance with AUROC 0.81 [95% confidence interval (CI) 0.77-0.84 and 0.81 (95% CI 0.78-0.85)], respectively. Time of CST performance had no significant effect on diagnostic accuracy of baseline cortisol while recent glucocorticoid use decreased diagnostic performance of DHEAS (AUROC 0.72 vs 0.83). Only 1.2% of patients with baseline cortisol ≥10 mcg/dL had AI based on CST. Among patients with baseline cortisol between 5 and 9.9 mcg/dL, only 1.3% had AI if DHEAS was ≥60 mcg/dL. Conversely, the majority (72.2%) of patients with both baseline cortisol &lt;5 mcg/dL and DHEAS &lt;25 mcg/dL were found to have AI. Conclusion DHEAS has good diagnostic performance in assessing AI. Measuring both baseline cortisol and DHEAS concentrations may eliminate the need for further dynamic testing in many patients.