B-355 Assessment of Calcitonin Cutoff Values for Post-Thyroidectomy Surveillance in Patients with Medullary Thyroid Carcinoma: Findings from a Single-Center Investigation
Abstract Background Patients with sporadic or hereditary Medullary Thyroid Carcinoma (MTC) often undergo total thyroidectomy and lymph node dissection, with postoperative surveillance relying on serum calcitonin levels and ultrasound examinations. According to American Thyroid Association (ATA) guidelines, detectable levels of serum calcitonin and Carcinoembryonic Antigen (CEA) post-thyroidectomy suggest potential disease persistence or recurrence, necessitating frequent monitoring for early detection. This study sought to reassess the role of postoperative calcitonin levels in identifying possible tumor recurrence. Methods A retrospective analysis was conducted using Siemens Atellica to test calcitonin levels in 562 samples collected between 09/27/2022 and 08/11/2023, at least 3 months post-total thyroidectomy. Imaging studies performed within 6 months of the calcitonin assessment were also reviewed. Sample pools with calcitonin concentrations near 3.00 and 5.00 pg/mL were utilized to determine the limit of quantification (LoQ). CEA results were included for comparison. Additionally, 16 serum samples were analyzed using the Roche Cobas system at a reference laboratory. Results Precision analysis around 3.00 and 5.00 pg/mL revealed coefficients of variation (CVs) of 16.49% and 8.87%, respectively. Comparison of calcitonin levels between Siemens Atellica and Roche Cobas systems demonstrated consistent levels < 5.00 pg/mL in 15 out of 16 samples, indicating alignment and reliability between the platforms. A calcitonin cutoff of 1.89 pg/mL yielded 43% sensitivity and 67% specificity, while a cutoff of 5.00 pg/mL resulted in 0% sensitivity and 100% specificity. Conclusions Our findings suggest that a 5 pg/mL calcitonin cutoff on the Siemens Atellica platform may be suitable for identifying tumor persistence or recurrence in post-thyroidectomy patients within our institution. However, individual laboratories should establish their LoQ criteria when interpreting calcitonin levels for postoperative monitoring of tumor recurrence.
American Head and Neck Society Endocrine Surgery Section and International Thyroid Oncology Group consensus statement on mutational testing in thyroid cancer: Defining advanced thyroid cancer and its targeted treatment
AbstractBackgroundThe development of systemic treatment options leveraging the molecular landscape of advanced thyroid cancer is a burgeoning field. This is a multidisciplinary evidence‐based statement on the definition of advanced thyroid cancer and its targeted systemic treatment.MethodsAn expert panel was assembled, a literature review was conducted, and best practice statements were developed. The modified Delphi method was applied to assess the degree of consensus for the statements developed by the author panel.ResultsA review of the current understanding of thyroid oncogenesis at a molecular level is presented and characteristics of advanced thyroid cancer are defined. Twenty statements in topics including the multidisciplinary management, molecular evaluation, and targeted systemic treatment of advanced thyroid cancer are provided.ConclusionsWith the growth in targeted treatment options for thyroid cancer, a consensus definition of advanced disease and statements regarding the utility of molecular testing and available targeted systemic therapy is warranted.
Selected Radiation Safety Aspects Including Transportation and Lodging After Outpatient
131
I Therapy for Differentiated Thyroid Cancer
United States and European Multicenter Prospective Study for the Analytical Performance and Clinical Validation of a Novel Sensitive Fully Automated Immunoassay for Calcitonin
Abstract BACKGROUND The objective of this study is the validation and proof of clinical relevance of a novel electrochemiluminescence immunoassay (ECLIA) for the determination of serum calcitonin (CT) in patients with medullary thyroid carcinoma (MTC) and in different diseases of the thyroid and of calcium homeostasis. METHODS This was a multicenter prospective study on basal serum CT concentrations performed in 9 US and European referral institutions. In addition, stimulated CT concentrations were measured in 50 healthy volunteers after intravenous calcium administration (2.5 mg/kg bodyweight). RESULTS In total, 1929 patients and healthy controls were included. Limits of blank, detection, and quantification for the ECLIA were 0.3, 0.5, and 1 ng/L, respectively. Highest intra- and interassay coefficients of variation were 7.4% (CT concentration, 0.8 ng/L) and 7.0% (1.1 ng/L), respectively. Medians (interval) of serum CT concentrations in 783 healthy controls were 0.8 ng/L (<0.5–12.7) and 3 ng/L (<0.5–18) for females and males, respectively (97.5th percentile, 6.8 and 11.6 ng/L, respectively). Diagnostic sensitivity and specificity were 100%/97.1% and 96.2%/96.4%, for female/males, respectively. Patients (male/female) with primary hyperparathyroidism, renal failure, and neuroendocrine tumors showed CT concentrations >97.5th percentile in 33%/4.7%, 18.5%/10%, and 8.3%/12%, females/males, respectively. Peak serum CT concentrations were reached 2 min after calcium administration (161.7 and 111.8 ng/L in males and females, respectively; P < 0.001). CONCLUSIONS Excellent analytical performance, low interindividual variability, and low impact of confounders for increased CT concentrations in non-MTC patients indicate that the investigated assay has appropriate clinical utility. Calcium-stimulated CT results suggest good test applicability owing to low interindividual variability.
Correlative Studies in Clinical Trials: A Position Statement From the International Thyroid Oncology Group