Citations

Mayo Clinic

Clear

12577 citation(s) found for "Ma, John".

Culture with BACTEC Peds Plus/F Bottle Compared with Conventional Methods for Detection of Bacteria in Synovial Fluid
Vetter, Emily A., Patel, Robin , Schleck, Cathy D. , Harmsen, Scott, Turgeant, L. Thomas, Cockerill, Franklin R., Hughes, John , Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4468-4471

10.1128/jcm.39.12.4468-4471.2001 | PMID 11724863 Get It

ABSTRACT An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens ( n = 62), contaminants ( n = 12), or indeterminate ( n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [ P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [ P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.
Comparison of the BACTEC MYCO/F Lytic Bottle to the Isolator Tube, BACTEC Plus Aerobic F/Bottle, and BACTEC Anaerobic Lytic/10 Bottle and Comparison of the BACTEC Plus Aerobic F/Bottle to the Isolator Tube for Recovery of Bacteria, Mycobacteria, and Fungi
Vetter, Emily A., Torgerson, C A, Feuker, A., Harmsen, Scott, Schleck, Cathy D. , Horstmeier, C D, Roberts, Glenn D., Cockerill, Franklin R., Hughes, John

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4380-4386

10.1128/jcm.39.12.4380-4386.2001 | PMID 11724848 Get It

ABSTRACT The BACTEC MYCO/F Lytic blood culture bottle (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is designed to optimize the recovery of fungi and mycobacteria; however, this bottle also supports the growth of most aerobic bacteria. We compared the MYCO/F Lytic bottle with two other BACTEC bottles and the Isolator system for the recovery of bacteria as well as fungi and mycobacteria from blood. A total of 6,108 blood culture sets were inoculated with blood obtained from adult patients. Twenty-five to 28 ml of blood collected by a phlebotomy team for each blood culture set was randomly distributed into each of four blood culture receptacles: the Isolator tube (Wampole Laboratories, Cranbury, N.J.) and three BACTEC bottles: the MYCO/F Lytic bottle, the BACTEC Plus Aerobic/F bottle, and the BACTEC Anaerobic Lytic/10 bottle. The sediment from the Isolator tube was inoculated onto chocolate agar (CA), brain heart infusion agar (BHI), and Sabouraud dextrose agar (SDA) and into a BACTEC 13A bottle. Incubation durations were as follows: MYCO/F Lytic bottle, 42 days; Plus Aerobic/F bottle, 5 days; Anaerobic Lytic/10 bottle, 5 days; sediment from Isolator tube on CA, 3 days; sediment from Isolator tube on BHI, 30 days; sediment from Isolator tube on SDA, 30 days; and sediment from Isolator tube in a BACTEC 13A bottle, 42 days. Two isolates of Histoplasma capsulatum were recovered from the Isolator tube only. Three isolates of Mycobacterium tuberculosis complex were recovered: two isolates from the MYCO/F Lytic bottle only and one isolate from the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle) only. Two isolates of Cryptococcus neoformans were recovered: one from the MYCO/F Lytic bottle only and the other from the MYCO/F Lytic bottle and the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle). For potential pathogens overall, there was a statistical difference in recovery that favored the Isolator system over the MYCO/F Lytic bottle ( P = 0.0015), including statistically significant differences for Staphylococcus aureus ( P = 0.0001) and Streptococcus pneumoniae ( P = 0.0313). However, there was no statistically significant difference between the two blood culture systems when detection of bloodstream infection was considered. The time to detection for all potential pathogens combined was less for the MYCO/F Lytic bottle than for the Isolator system ( P = 0.0004). Overall, the potential pathogen recovery was greater for the BACTEC Plus Aerobic/F bottle than for either the Isolator system ( P = 0.0003) or the MYCO/F Lytic bottle ( P = 0.0001). However, the BACTEC Plus Aerobic/F bottle did not recover M. tuberculosis , H. capsulatum , or C. neoformans isolates. The combination of the Isolator system and MYCO/F Lytic bottle may be useful as a selective blood culture method to optimize the recovery of fungi and mycobacteria from blood. Compared with the manual Isolator system, the MYCO/F Lytic system has the advantage of less preanalytic processing and continuous automated monitoring of bottles for growth by the BACTEC 9240 instrument.
Direct Identification of Bacteria from Positive Blood Cultures by Amplification and Sequencing of the 16S rRNA Gene: Evaluation of BACTEC 9240 Instrument True- Positive and False-Positive Results
Qian, Qinfang, Kolbert, Christopher P., Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Montgomery, Stacy O., Cockerill, Franklin R., Persing, David H., Tang, Yi‐Wei , Hughes, John

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 10 | Pages: 3578-3582

10.1128/jcm.39.10.3578-3582.2001 | PMID 11574575 Get It

ABSTRACT In a previous study which evaluated the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.), we noted a 1.3% “instrument false-positive” rate. That is, the BACTEC system signaled that a bottle (BACTEC Plus Aerobic/F bottle or BACTEC Anaerobic Lytic/10 bottle) culture was positive but a Gram stain was negative and there was no growth of bacteria or yeasts on subculture to chocolate agar. Furthermore, from the same sample of blood, cultures for fungi using the Isolator blood culture system (Wampole Laboratories, Cranbury, N.J.) were negative for growth. For the present study, we evaluated 76 instrument false-positive samples for the presence of 16S ribosomal DNA using the MicroSeq 500 kit (PE Biosystems, Foster City, Calif.). These samples also were negative for fungi by the Isolator method. This kit has a PCR module and sequencing module for the amplification and sequencing of the 16S RNA gene and provides a database for sequence alignment and identification of bacteria. To optimize the assay, we evaluated the effect of adding 0.5% bovine serum albumin to the sample from blood culture bottles and found that it decreased the effects of inhibitors on the PCR. Two control groups of blood culture specimens were also evaluated. One group ( n = 45) were “instrument true positives”; the instrument signaled positive, and subsequent Gram stains were positive and subcultures on chocolate agar grew bacteria. The other group ( n = 20) were “instrument true negatives”; the instrument signaled negative, the Gram stain was negative, and subcultures on chocolate agar and from the Isolator tube on fungal media showed no growth. None of the 76 instrument false-positive samples had evidence for 16S rRNA gene sequences. All of the instrument true-positive samples and all of the instrument true-negative specimens were positive and negative, respectively, using the MicroSeq 500 kit. Total peripheral white blood cell counts were statistically significantly higher for patients who had instrument false-positive results than for patients who had instrument true-positive or true-negative results ( P = 0.001). We conclude that instrument false positives signaled by the BACTEC 9240 system are not due to bacteria in the blood culture samples.
Frequency of Isolation of Staphylococcus lugdunensis in Consecutive Urine Cultures and Relationship to Urinary Tract Infection
Haile, Dawit T. , Vetter, Emily A., Kohner, Peggy C., Patel, Robin , Cockerill, Franklin R., Hughes, John , Snyder, Richard V. , Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 2 | Pages: 654-656

10.1128/jcm.40.2.654-656.2002 | PMID 11825988 Get It

ABSTRACT Recent reports associate Staphylococcus lugdunensis with severe infection in humans. The frequency of this microorganism in urine cultures is unknown. Five hundred isolates of coagulase-negative staphylococci (CoNS) were recovered from 4,652 consecutive urine specimens submitted for culture to the Mayo Clinic Microbiology Laboratory. Thirty-one (6%) of 500 isolates of CoNS were identified as S. lugdunensis . In no case was S. lugdunensis isolated in pure culture; 29 (94%) of 31 S. lugdunensis isolates were part of mixed nonpathogenic flora. Medical records were reviewed for 30 of the 31 patients from whom these 31 isolates were isolated. Twenty-one (70%) of the 30 evaluable patients were not treated with antibiotics; the remaining 9 (30%) of 30 patients were treated with antibiotics that may be effective against S. lugdunensis. S. lugdunensis may be an unrecognized yet infrequent cause of urinary tract infection.
Phosphorylation of the Translational Repressor PHAS-I by the Mammalian Target of Rapamycin
Brunn, Gregory J., Hudson, Christine C., Sekulić, Aleksandar , Williams, Josie M., Hosoi, Hajime , Houghton, Peter J. , Lawrence, John C., Abraham, Robert T.

Science | July 27, 2002 | Volume: 277 | Issue: 5322 | Pages: 99-101

10.1126/science.277.5322.99 | PMID 9204908 Get It

The immunosuppressant rapamycin interferes with G 1 -phase progression in lymphoid and other cell types by inhibiting the function of the mammalian target of rapamycin (mTOR). mTOR was determined to be a terminal kinase in a signaling pathway that couples mitogenic stimulation to the phosphorylation of the eukaryotic initiation factor (eIF)-4E–binding protein, PHAS-I. The rapamycin-sensitive protein kinase activity of mTOR was required for phosphorylation of PHAS-I in insulin-stimulated human embryonic kidney cells. mTOR phosphorylated PHAS-I on serine and threonine residues in vitro, and these modifications inhibited the binding of PHAS-I to eIF-4E. These studies define a role for mTOR in translational control and offer further insights into the mechanism whereby rapamycin inhibits G 1 -phase progression in mammalian cells.
Susceptibility Locus for Alzheimer's Disease on Chromosome 10
Holmans, Peter , Marshall, Helen, Kwon, Jennifer M. , Meyer, David , Ramic, Dzanan, Shears, Shantia, DeVriéze, Fabienne Wavrant, Hamshere, Marian L. , Abraham, Richard, Tunstall, Nigel, Rice, Frances , Carty, Stephanie, Lillystone, Sara, Kehoe, Patrick G. , Rudrasingham, Varuni, Jones, Lesley , Lovestone, Simon , Pérez‐Tur, Jordi , Williams, Julie , Hardy, John , Goate, Alison , Myers, Amanda , Booth, Jeremy , Crook, Richard , Owen, Michael J. , Hardy, John , Goate, Alison M

Science | July 27, 2002 | Volume: 290 | Issue: 5500 | Pages: 2304-2305

10.1126/science.290.5500.2304 | PMID 11125144 Get It

The apolipoprotein E ( APOE ) gene is the only genetic risk factor that has so far been linked to risk for late-onset Alzheimer's disease (LOAD). However, 50 percent of Alzheimer's disease cases do not carry an APOE4 allele, suggesting that other risk factors must exist. We performed a two-stage genome-wide screen in sibling pairs with LOAD to detect other susceptibility loci. Here we report evidence for an Alzheimer's disease locus on chromosome 10. Our stage one multipoint lod score (logarithm of the odds ratio for linkage/no linkage) of 2.48 (266 sibling pairs) increased to 3.83 in stage 2 (429 sibling pairs) close to D10S1225 (79 centimorgans). This locus modifies risk for Alzheimer's disease independent of APOE genotype.
Linkage of Plasma Aβ42 to a Quantitative Locus on Chromosome 10 in Late-Onset Alzheimer's Disease Pedigrees
Ertekin‐Taner, Nilüfer , Younkin, Linda H., Eckman, Christopher B., Adamson, Jennifer, Hutton, Michael , Younkin, Steven G., Graff, Caroline , Baker, Matthew , Ronald, James , Blangero, John

Science | July 27, 2002 | Volume: 290 | Issue: 5500 | Pages: 2303-2304

10.1126/science.290.5500.2303 | PMID 11125143 Get It

Plasma Aβ42 (amyloid β42 peptide) is invariably elevated in early-onset familial Alzheimer's disease (AD), and it is also increased in the first-degree relatives of patients with typical late-onset AD (LOAD). To detect LOAD loci that increase Aβ42, we used plasma Aβ42 as a surrogate trait and performed linkage analysis on extended AD pedigrees identified through a LOAD patient with extremely high plasma Aβ. Here, we report linkage to chromosome 10 with a maximal lod score of 3.93 at 81 centimorgans close to D10S1225. Remarkably, linkage to the same region was obtained independently in a genome-wide screen of LOAD sibling pairs. These results provide strong evidence for a novel LOAD locus on chromosome 10 that acts to increase Aβ.
Genetics of Parkinson's Disease
Lynch, Timothy , Hutton, Mike, Hardy, John , Farrer, Matthew J. , Hardy, John

Science | July 27, 2002 | Volume: 278 | Issue: 5341 | Pages: 1209-1213

10.1126/science.278.5341.1209d Get It

Genetic Classification of Primary Neurodegenerative Disease
Hardy, John , Gwinn, Katrina , Hardy, John

Science | July 27, 2002 | Volume: 282 | Issue: 5391 | Pages: 1075-1079

10.1126/science.282.5391.1075 | PMID 9804538 Get It

During the past 10 years (the “decade of the brain”), some of the genetic causes of many of the primary neurodegenerative diseases, which include Alzheimer's disease, Parkinson's disease, Huntington's disease, amyotrophic lateral sclerosis, prion disease, and many ataxic syndromes, have been found. These breakthroughs mean that for many of these diseases we now know the initiating trigger as well as the final outcome. These diseases have many pathological mechanisms in common, and there may be relatively few pathways to neuronal death seen in these disorders. Thus, treatment strategies developed for a particular disease may be found to have efficacy in more than one disorder.
Role of Dynamin in the Formation of Transport Vesicles from the Trans-Golgi Network
Jones, Steven M. , Howell, Kathryn E., Henley, John R. , Cao, Hong , McNiven, Mark A.

Science | July 27, 2002 | Volume: 279 | Issue: 5350 | Pages: 573-577

10.1126/science.279.5350.573 | PMID 9438853 Get It

Dynamin guanosine triphosphatases support the scission of clathrin-coated vesicles from the plasmalemma during endocytosis. By fluorescence microscopy of cultured rat hepatocytes, a green fluorescent protein–dynamin II fusion protein localized with clathrin-coated vesicles at the Golgi complex. A cell-free assay was utilized to demonstrate the role of dynamin in vesicle formation at the trans-Golgi. Addition of peptide-specific anti-dynamin antibodies to the assay mixture inhibited both constitutive exocytic and clathrin-coated vesicle formation. Immunodepletion of dynamin proteins also inhibited vesicle formation, and budding efficiency was restored upon readdition of purified dynamin. These data suggest that dynamin participates in the formation of distinct transport vesicles from the trans-Golgi network.