Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3
Ding, Xuanfeng , Liang, Xiaoying , Oancea, Cristina , Wang, Peilong, Rule, William G., Liu, Wei , Shen, Jiajian , Liang, Xiaoying , Liu, Wei , Shen, Jiajian , Charyyev, Serdar , Wang, Peilong, Bues, Martin , Lin, Liyong

Journal of Applied Clinical Medical Physics | August 13, 2024 | Volume: 25 | Issue: 9 | Pages: No page available

10.1002/acm2.14486 Get It

AbstractPurposeThe time structures of proton spot delivery in proton pencil beam scanning (PBS) radiation therapy are essential in many clinical applications. This study aims to characterize the time structures of proton PBS delivered by both synchrotron and synchrocyclotron accelerators using a non‐invasive technique based on scattered particle tracking.MethodsA pixelated semiconductor detector, AdvaPIX‐Timepix3, with a temporal resolution of 1.56 ns, was employed to measure time of arrival of secondary particles generated by a proton beam. The detector was placed laterally to the high‐flux area of the beam in order to allow for single particle detection and not interfere with the treatment. The detector recorded counts of radiation events, their deposited energy and the timestamp associated with the single events. Individual recorded events and their temporal characteristics were used to analyze beam time structures, including energy layer switch time, magnet switch time, spot switch time, and the scanning speeds in the x and y directions. All the measurements were repeated 30 times on three dates, reducing statistical uncertainty.ResultsThe uncertainty of the measured energy layer switch times, magnet switch time, and the spot switch time were all within 1% of average values. The scanning speeds uncertainties were within 1.5% and are more precise than previously reported results. The measurements also revealed continuous sub‐milliseconds proton spills at a low dose rate for the synchrotron accelerator and radiofrequency pulses at 7 µs and 1 ms repetition time for the synchrocyclotron accelerator.ConclusionThe AdvaPIX‐Timepix3 detector can be used to directly measure and monitor time structures on microseconds scale of the PBS proton beam delivery. This method yielded results with high precision and is completely independent of the machine log files.
Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images
Liu, Wei , Ding, Yuzhen , McGee, L.A. , Rwigema, Jean‐Claude M. , Vora, Sujay A., Wong, William W. , Foote, Robert L. , Patel, Samir H. , Liu, Wei

No container title available | April 3, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-4086699/v1 Get It

Abstract In radiotherapy, 2D orthogonally projected kV images are used for patient alignment when 3D-on-board imaging(OBI) unavailable. But tumor visibility is constrained due to the projection of patient’s anatomy onto a 2D plane, potentially leading to substantial setup errors. In treatment room with 3D-OBI such as cone beam CT(CBCT), the field of view(FOV) of CBCT is limited with unnecessarily high imaging dose, thus unfavorable for pediatric patients. A solution to this dilemma is to reconstruct 3D CT from kV images obtained at the treatment position. Here, we propose a dual-models framework built with hierarchical ViT blocks. Unlike a proof-of-concept approach, our framework considers kV images as the solo input and can synthesize accurate, full-size 3D CT in real time(within milliseconds). We demonstrate the feasibility of the proposed approach on 10 patients with head and neck(H\&N) cancer using image quality(MAE:<45HU), dosimetric accuracy(Gamma passing rate(2%/2mm/10%):>97%) and patient position uncertainty(shift error:<0.4mm). The proposed framework can generate accurate 3D CT faithfully mirroring real-time patient position, thus significantly improving patient setup accuracy, keeping imaging dose minimum, and maintaining treatment veracity.
Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue
Wang, ‪Zhehui , Malko, S. , Liu, Wei , Tremsin, Anton S.

Applied Optics | April 2, 2024 | Volume: 63 | Issue: 12 | Pages: ROADS1

10.1364/ao.525556 Get It

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, γ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods , and Data Science , as described in Appl. Opt. 61 , RDS1 ( 2022 ) APOPAI 0003-6935 10.1364/AO.455628 . Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.
Technical note: Generalizable and promptable artificial intelligence model to augment clinical delineation in radiation oncology
Liu, Zhengliang , Zhang, Lu , Feng, Hongying , Dai, Haixing , Li, Xiang , Wong, William W. , Vora, Sujay A., Liu, Tianming , Zhang, Lian , Wu, Zihao , Yu, Xiaowei , Holmes, Jason , Li, Quanzheng , Zhu, Dajiang , Liu, Wei

Medical Physics | February 7, 2024 | Volume: 51 | Issue: 3 | Pages: 2187-2199

10.1002/mp.16965 Get It

Abstract Background Efficient and accurate delineation of organs at risk (OARs) is a critical procedure for treatment planning and dose evaluation. Deep learning‐based auto‐segmentation of OARs has shown promising results and is increasingly being used in radiation therapy. However, existing deep learning‐based auto‐segmentation approaches face two challenges in clinical practice: generalizability and human‐AI interaction. A generalizable and promptable auto‐segmentation model, which segments OARs of multiple disease sites simultaneously and supports on‐the‐fly human‐AI interaction, can significantly enhance the efficiency of radiation therapy treatment planning. Purpose Meta's segment anything model (SAM) was proposed as a generalizable and promptable model for next‐generation natural image segmentation. We further evaluated the performance of SAM in radiotherapy segmentation. Methods Computed tomography (CT) images of clinical cases from four disease sites at our institute were collected: prostate, lung, gastrointestinal, and head & neck. For each case, we selected the OARs important in radiotherapy treatment planning. We then compared both the Dice coefficients and Jaccard indices derived from three distinct methods: manual delineation (ground truth), automatic segmentation using SAM's ’segment anything’ mode, and automatic segmentation using SAM's ‘box prompt’ mode that implements manual interaction via live prompts during segmentation. Results Our results indicate that SAM's segment anything mode can achieve clinically acceptable segmentation results in most OARs with Dice scores higher than 0.7. SAM's box prompt mode further improves Dice scores by 0.1∼0.5. Similar results were observed for Jaccard indices. The results show that SAM performs better for prostate and lung, but worse for gastrointestinal and head & neck. When considering the size of organs and the distinctiveness of their boundaries, SAM shows better performance for large organs with distinct boundaries, such as lung and liver, and worse for smaller organs with less distinct boundaries, like parotid and cochlea. Conclusions Our results demonstrate SAM's robust generalizability with consistent accuracy in automatic segmentation for radiotherapy. Furthermore, the advanced box‐prompt method enables the users to augment auto‐segmentation interactively and dynamically, leading to patient‐specific auto‐segmentation in radiation therapy. SAM's generalizability across different disease sites and different modalities makes it feasible to develop a generic auto‐segmentation model in radiotherapy.
Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy
Feng, Hongying , Holmes, Jason , Vora, Sujay A., Stoker, J. , Bues, Martin , Wong, William W. , Sio, Terence S., Foote, Robert L. , Patel, Samir H. , Holmes, Jason M , Stoker, Joshua B., Shen, Jiajian , Liu, Wei , Bues, Martin , Shen, Jiajian , Liu, Wei

Physics in Medicine & Biology | November 9, 2023 | Volume: 69 | Issue: 3 | Pages: 035003

10.1088/1361-6560/ad0b64 Get It

Abstract Purpose . To enhance an in-house graphic-processing-unit accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and materials . A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3 cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4 cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45 mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 c.c. with range of 0.4–43.3 c.c.). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC. Results . In the water phantoms, 3D gamma passing rate (2%/2 mm/10%) between VPMC and MCsquare was 99.71 ± 0.23%. In the patient geometries, 3D gamma passing rates (3%/2 mm/10%) between VPMC/MCsquare and RayStation MC were 97.79 ± 2.21%/97.78 ± 1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45 ± 114.08 s (MCsquare) to 8.20 ± 6.42 s (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose–volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 s and the subsequent on-the-fly ‘trial-and-error’ optimization procedure took only 71.4 s on average for the selected three patients. Conclusion . VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.
Beam mask and sliding window‐facilitated deep learning‐based accurate and efficient dose prediction for pencil beam scanning proton therapy
Zhang, Lian , Vora, Sujay A., Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Liu, Tianming , Shen, Jiajian , Wong, William W. , Holmes, Jason M, Schild, Steven E. , Shen, Jiajian , Holmes, Jason , Liu, Zhengliang , Sio, Terence T. , Bues, Martin , Li, Sheng , Liu, Wei

Medical Physics | September 25, 2023 | Volume: 51 | Issue: 2 | Pages: 1484-1498

10.1002/mp.16758 Get It

AbstractBackgroundAccurate and efficient dose calculation is essential for on‐line adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results in photon therapy. However, there is a scarcity of DL‐based dose prediction methods specifically designed for proton therapy. Successful dose prediction method for proton therapy should account for more challenging dose prediction problems in pencil beam scanning proton therapy (PBSPT) due to its sensitivity to heterogeneities.PurposeTo develop a DL‐based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on‐line adaptive proton therapy clinical decision and subsequent replanning.MethodsPBSPT plans of 103 prostate cancer patients (93 for training and the other 10 for independent testing) and 83 lung cancer patients (73 for training and the other 10 for independent testing) previously treated at our institution were included in the study, each with computed tomography scans (CTs), structure sets, and plan doses calculated by the in‐house developed Monte‐Carlo dose engine (considered as the ground truth in the model training and testing). For the ablation study, we designed three experiments corresponding to the following three methods: (1) Experiment 1, the conventional region of interest (ROI) (composed of targets and organs‐at‐risk [OARs]) method. (2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. (3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D‐Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates with a criterion of 3%/3 mm/10%, and dice coefficients for the structures enclosed by the iso‐dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency.ResultsCompared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices (for lung cancer, CTV D98 absolute deviation: 0.74 ± 0.18 vs. 0.57 ± 0.21 vs. 0.54 ± 0.15 Gy[RBE], ROI vs. beam mask vs. sliding window methods, respectively). For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method improved the passing rates in these regions and the sliding window method further improved them (for prostate cancer, targets: 96.93% ± 0.53% vs. 98.88% ± 0.49% vs. 99.97% ± 0.07%, BODY: 86.88% ± 0.74% vs. 93.21% ± 0.56% vs. 95.17% ± 0.59%). A similar trend was also observed for the dice coefficients. This trend was especially remarkable for relatively low prescription isodose lines (for lung cancer, 10% isodose line dice: 0.871 ± 0.027 vs. 0.911 ± 0.023 vs. 0.927 ± 0.017). The dose predictions for all the testing cases were completed within 0.25 s.ConclusionsAn accurate and efficient deep learning‐augmented proton dose prediction framework has been developed for PBSPT, which can predict accurate dose distributions not only inside but also outside ROI efficiently. The framework can potentially further reduce the initial planning and adaptive replanning workload in PBSPT.
Needs, Trends, and Advances in Scintillators for Radiographic Imaging and Tomography
Wang, ‪Zhehui , Dujardin, Christophe , Freeman, Matthew S. , Gehring, Amanda , Lecoq, P. , Liu, Wei , Melcher, Charles L. , Morris, C. L. , Nikl, M. , Robertson, Daniel , Rutstrom, Daniel , Watson, S. A., Wiggins, Brenden , Winch, Nicola M. , Liu, Wei , Hunter, J. F. , Pilania, Ghanshyam , Pokharel, Reeju , Sjue, Sky K. , Tremsin, Anton S. , Zhuravleva, Mariya

IEEE Transactions on Nuclear Science | June 28, 2023 | Volume: 70 | Issue: 7 | Pages: 1244-1280

10.1109/tns.2023.3290826 Get It

Radiotherapy toxicity prediction using knowledge-constrained generalized linear model
Hu, Jiuyun, Fatyga, M., Wong, William W. , Vora, Sujay A., Li, Jing , Fatyga, Mirek, Schild, Steven E. , Liu, Wei

IISE Transactions on Healthcare Systems Engineering | June 20, 2023 | Volume: 14 | Issue: 2 | Pages: 130-140

10.1080/24725579.2023.2227199 Get It

Deep‐learning based fast and accurate 3D CT deformable image registration in lung cancer
Ding, Yuzhen , Feng, Hongying , Yang, Yunze, Wong, William W. , Yu, Nathan Y. , Schild, Steven E. , Holmes, Jason , Liu, Zhengliang , Liu, David M. , Sio, Terence T. , Li, Baoxin , Liu, Wei

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 11 | Pages: 6864-6880

10.1002/mp.16548 Get It

AbstractBackgroundDeformable Image Registration (DIR) is an essential technique required in many applications of radiation oncology. However, conventional DIR approaches typically take several minutes to register one pair of 3D CT images and the resulting deformable vector fields (DVFs) are only specific to the pair of images used, making it less appealing for clinical application.PurposeA deep‐learning‐based DIR method using CT images is proposed for lung cancer patients to address the common drawbacks of the conventional DIR approaches and in turn can accelerate the speed of related applications, such as contour propagation, dose deformation, adaptive radiotherapy (ART), etc.MethodsA deep neural network based on VoxelMorph was developed to generate DVFs using CT images collected from 114 lung cancer patients. Two models were trained with the weighted mean absolute error (wMAE) loss and structural similarity index matrix (SSIM) loss (optional) (i.e., the MAE model and the M+S model). In total, 192 pairs of initial CT (iCT) and verification CT (vCT) were included as a training dataset and the other independent 10 pairs of CTs were included as a testing dataset. The vCTs usually were taken 2 weeks after the iCTs. The synthetic CTs (sCTs) were generated by warping the vCTs according to the DVFs generated by the pre‐trained model. The image quality of the synthetic CTs was evaluated by measuring the similarity between the iCTs and the sCTs generated by the proposed methods and the conventional DIR approaches, respectively. Per‐voxel absolute CT‐number‐difference volume histogram (CDVH) and MAE were used as the evaluation metrics. The time to generate the sCTs was also recorded and compared quantitatively. Contours were propagated using the derived DVFs and evaluated with SSIM. Forward dose calculations were done on the sCTs and the corresponding iCTs. Dose volume histograms (DVHs) were generated based on dose distributions on both iCTs and sCTs generated by two models, respectively. The clinically relevant DVH indices were derived for comparison. The resulted dose distributions were also compared using 3D Gamma analysis with thresholds of 3 mm/3%/10% and 2 mm/2%/10%, respectively.ResultsThe two models (wMAE and M+S) achieved a speed of 263.7±163 / 265.8±190 ms and a MAE of 13.15±3.8 / 17.52±5.8 HU for the testing dataset, respectively. The average SSIM scores of 0.987±0.006 and 0.988±0.004 were achieved by the two proposed models, respectively. For both models, CDVH of a typical patient showed that less than 5% of the voxels had a per‐voxel absolute CT‐number‐difference larger than 55 HU. The dose distribution calculated based on a typical sCT showed differences of ≤2cGy[RBE] for clinical target volume (CTV) D95 and D5, within ±0.06% for total lung V5, ≤1.5cGy[RBE] for heart and esophagus Dmean, and ≤6cGy[RBE] for cord Dmax compared to the dose distribution calculated based on the iCT. The good average 3D Gamma passing rates (> 96% for 3 mm/3%/10% and > 94% for 2 mm/2%/10%, respectively) were also observed.ConclusionA deep neural network‐based DIR approach was proposed and has been shown to be reasonably accurate and efficient to register the initial CTs and verification CTs in lung cancer.
Phase II study of short course hypofractionated proton beam therapy incorporating 18F-DOPA-PET/MRI for elderly patients with newly diagnosed glioblastoma.
Vora, Sujay A., Pafundi, Deanna, Voss, Molly M., Ashman, Jonathan B. , Bendock, Bernard, Mahajan, Anita , Mrugała, Maciej M. , Porter, Alyx B. , Ruff, Michael W. , Uhm, Joon H. , Brinkmann, Debra H. , Yang, Ming , Brown, Paul D. , DeWees, T.A. , Laack, Nadia N. , Liu, Wei , Sio, Terence T.

Journal of Clinical Oncology | June 4, 2023 | Volume: 41 | Issue: 16_suppl | Pages: 2002-2002

10.1200/jco.2023.41.16_suppl.2002 Get It

2002 Background: Elderly patients with glioblastoma have a poor prognosis with phase III trials reporting median overall survival (OS) and global time to deterioration of 6–9 and 1.2 months respectively. 18F-DOPA (3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine) positron emission tomography (PET) is sensitive and specific for identifying regions of high density and biologically aggressive glioblastoma. Proton beam therapy (PBT) can spare more healthy tissue that may improve quality of life for this patient population. With improved targeting of disease along with dosimetric advantages of PBT, this phase II trial tested whether hypofractionated PBT can offer both improved survival and quality of life. Methods: Patients with newly diagnosed glioblastoma aged ≥65 years without contraindications to 18F-DOPA were eligible. Target volumes were defined by PET (tumor/normal brain SUV ≥2.0) and MRI areas of contrast enhancement including surgical cavity. Patients received dose escalated hypofractionated PBT of 35-40 GyE to PET/MRI over 5-10 treatments with 10 mm margin. Patients received concurrent/adjuvant temozolomide. With an alpha of 0.1, 18 of 39 patients would be required to be alive at 12 months for the study to be considered a success. Kaplan-Meier/Cox regression analysis was performed for progression free survival (PFS) and OS. Toxicities were evaluated with CTCAE v4.0. Patients completed EORTC BN20, QLQ-C30, and MMSE questionnaires. Time to deterioration, defined as a 10-point decrease in the score of the function domain or 10-point increase in score of symptom domain, was evaluated. Results: Between 5/2019-6/2021, 43 patients were enrolled, with 4 patients withdrawing due to progression/insurance denial prior to beginning protocol therapy. The median age was 70.2 yrs. and median follow-up was 12.5 months. MGMT methylation was present in 13 (33%). Tumors were multifocal in 10 (26%) and unifocal in 29 (74%). The primary endpoint was met with median PFS/OS was 6.5/12.9 months for all patients and for MGMT methylated patients 11.9/29.8 months respectively. Grade 3 baseline adjusted treatment related adverse events included 1 (3%) confusion, 2 (5%) fatigue, and 1 (3%) seizure. There were no grade 4/5 events. Multivariate analysis revealed MGMT unmethylated, ECOG 2 and biopsy only patients had worse survival. PET volume was more predictive than MRI volume for OS with PET volume>26 cc having a hazard ratio of 3.7. The median time to global deterioration per QLC-C30 was 6.3 months. Conclusions: This phase II trial incorporating 18F-DOPA PET-guided dose escalated hypofractionated proton beam treatment for elderly patients with glioblastoma met its primary endpoint for improved OS and patient reported quality of life compared to historical controls. Further investigation is warranted. Clinical trial information: NCT03778294 .