Epicardial Pulsed Field Ablation of Ganglionated Plexi: Computational and Pre-Clinical Evaluation of a Bipolar Sub-Xiphoid Catheter for the Treatment of Atrial Fibrillation
Epicardial pulsed field ablation (PFA) of ganglionated plexi (GPs) is being explored as a potential treatment for atrial fibrillation. Initial work using open-chest access with a monopolar ablation device has been completed. This study describes the early development work for a device that can be used with subxiphoid access and deliver bipolar ablation pulses. Electric field computational models have been used for the initial guidance on pulse parameters. An in vivo assessment of these ablation parameters has been performed in an open-chest canine study, while subxiphoid access and navigation of the device has been demonstrated in a porcine model. Results from this acute study have demonstrated the promising potential of this approach.
Targeted Ablation of Epicardial Ganglionated Plexi During Cardiac Surgery with Pulsed Field Electroporation ( NEURAL AF )
Background : Modulation of the cardiac autonomic nervous system (ANS) is a promising adjuvant therapy in the treatment of atrial fibrillation (AF). In pre-clinical models, pulsed field (PF) energy has the advantage of selectively ablating the epicardial ganglionated plexi (GP) that govern the ANS. Objective: This study aims to demonstrate the feasibility and safety of epicardial ablation of the GPs with PF during cardiac surgery with a primary efficacy outcome of prolongation of the atrial effective refractory period (AERP). Methods : In a single-arm, prospective analysis, patients with or without a history of AF underwent epicardial GP ablation with PF during coronary artery bypass grafting (CABG). AERP was determined immediately pre- and post- GP ablation to assess cardiac ANS function. Holter monitors were performed to determine rhythm status and Heart Rate Variability (HRV) at baseline and at 1 month post-procedure. Conclusions : This study demonstrates the safety and feasibility of epicardial ablation of the GP using PF to modulate the ANS during cardiac surgery. Large, randomized analyses are necessary to determine whether epicardial PF ablation can offer a meaningful impact on the cardiac ANS and reduce AF. Results : Of 24 patients, 23 (96%) received the full ablation protocol. No device-related adverse effects were noted. GP ablation resulted in a 20.7% ± 19.9% extension in AERP (P < 0.001). Post-operative AF was observed in 7 (29%) patients. Holter monitoring demonstrated an increase in mean heart rate (74.0±8.7 vs 80.6±12.3, P=0.01). There were no significant changes in HRV. There were no study-related complications.
Safety and Efficacy With Pulsed Field Ablation: Having the Cake and Eating It Too
Idiopathic ventricular tachycardia (VT) is an important cause of morbidity and less commonly, mortality in patients with structurally normal hearts. Appropriate diagnosis and management are predicated on an understanding of the mechanism, relevant cardiac anatomy, and associated ECG signatures. Catheter ablation is a viable strategy to adequately treat and potentially provide a cure in patients that are intolerant to medications or when these are ineffective. In this review, we discuss special approaches and considerations for effective and safe ablation of VT arising from the right ventricular outflow tract, left ventricular outflow tract, left ventricular fascicles, papillary muscles, and moderator band.
MRI-based numerical modeling of cardiac pulsed field ablation (PFA) with sub-microsecond pulses
Abstract Background The use of irreversible electroporation (IRE) for cardiac ablation in the management of cardiac arrhythmias, known as Pulsed Field Ablation (PFA), has gained the attention of many researchers, physicians and companies. Despite the demonstrated efficacy and safety profiles of the technique, there are still many open questions. One of them deals with the effective electric field thresholds necessary for cardiac tissue ablation. Contrary to radiofrequency (RF) ablation, where the thermotemporal thresholds for tissue damage are well established, the electric field thresholds for effective IRE are uncertain and depend on the tissue type and the waveform characteristics of the delivered electric field. Purpose The use of numerical models to understand the electric field distribution and the corresponding lesion for a specific electrode geometry are widely used in IRE for cancer treatment. Models can predict ablation volumes when the field thresholds are known or can be used to estimate the field thresholds when the lesion geometry is established post-treatment. The goal of the present study was to build a subject-specific realistic 3D numerical model to assess the ability of modeling to predict PFA lesions. Methods PFA experiments were performed in male mongrel dogs following a protocol approved by the Mayo Clinic Institutional Animal Care and Use Committee. Briefly, animals were sedated and intubated, and two non-irrigated deflectable catheters with an 8-mm tip were positioned on both sides of the interventricular septum under fluoroscopy guidance. Submicrosecond pulses were delivered in a bipolar fashion across both catheters. Sequences of pulses of 300 ns duration (or other durations in that range) were repetitively applied with voltage levels in the kV range. 30 days after the procedure, MRI with late gadolinium enhancement (LGE) were acquired to assess the presence of ablation lesions in the treated tissue. Ventricular areas were segmented from MRI images and 3D volumes were created. The generated 3D geometries were imported into software COMSOL Multiphysics. Realistic 3D geometries of the catheters were placed in the same positions than during the experiments, fluoroscopy videos recorded during the procedures were used as a guidance. The computed electric field intensity distributions were compared to the LGE areas to extract the range of electric field thresholds where the predicted lesion size was compatible with the real size of the LGE areas for each application site and pulsing protocol. Results and conclusions Our results show how the numerical model is able to reproduce the shape of the LGE fibrotic lesion areas observed 30 days after the procedure. Additionally, the model clearly confirms the dose-dependent lesion sizes observed experimentally. This study supports that numerical modeling is a valuable tool for understanding PFA treatments and that it could be used as patient-specific treatment planning tool. Funding Acknowledgement Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction
Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
Selective epicardial pulsed field ablation of atrial ganglionated plexi causes anti-arrhythmic prolongation of refractoriness: demonstration of feasibility in cardiac surgery patients
Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – EU funding. Main funding source(s): EU Horizon 2020 SME Instrument. Background Epicardial ganglionated plexi (GP) play a significant role in the initiation and maintenance of atrial fibrillation. However, modulation of this effect, through GP ablation, has had limited success; outcomes being confounded by unnecessary atrial tissue ablation and inability to access and ablate all of the atrial GPs. Selective pulsed field ablation (PFA) of GPs, using epicardial access, provides the opportunity to better identify the role of GP ablation in the treatment of atrial fibrillation. Purpose This study aimed to assess the safety and feasibility of selective GP ablation in patients undergoing elective coronary artery bypass grafting (CABG). It was hypothesized that GP ablation would provide an acute extension of atrial tissue refractoriness, which constitutes its antiarrhythmic effect. Methods Using a monopolar, monophasic PFA system, atrial GPs were ablated in nineteen patients with or without atrial fibrillation, undergoing CABG. The Oblique Sinus GP, Right Superior GP, Transverse Sinus GP, Left Superior GP and Ligament of Marshall GP were each ablated with up to sixty PFA pulses of 1000 V amplitude and 100 µs pulse width. Atrial Effective Refractory Period (AERP) was measured before and after all GP ablations, at the left atrial appendage (LAA) and on the right atrium (RA). Patients were monitored through to discharge for post-operative atrial fibrillation (POAF). Results Complete ablation of the GPs was performed in nineteen patients (aged 63.4 ± 6.6 years, 63.1% male) immediately after sternotomy. Electric field pulses were ECG-gated, with energy delivery during the ventricular refractory period. All GP sites were successfully accessed and ablated; all patients progressed immediately to their planned elective surgery and were discharged on schedule. Procedure time, for all GP ablations and AERP measurements was in the range 35-45 minutes. Thirteen valid pre- and post-ablation datasets were obtained. AERP (LAA and RA combined) increased upon GP ablation on average by 23% (220 ± 46 ms pre-ablation versus 269 ± 59 ms post-ablation, p = 0.002). Four patients experienced POAF; there was no evident correlation between POAF and AERP data. Only three of the enrolled patients had a prior history of AF; none of these exhibited AF on 24-hour Holter monitoring at 3-month follow-up. Conclusions Selective epicardial PFA of GPs is feasible and safe. An acute increase in atrial tissue refractoriness is promising but further studies are required to see how this translates to longer term outcomes in symptomatic AF patients and in a percutaneous epicardial access setting.
Atrial fibrillation in partial anomalous pulmonary venous return: right atrial drainage from one vein and epicardial conduction from another vein