Back to Authors

Sugrue, Alan

https://orcid.org/0000-0001-9921-6968

Mayo Clinic

Mayo Clinic

Citations 54

Abstract 17403: Prognositic Significance of T peak - T end Interval in Transthyretin Cardiac Amyloidosis
Sugrue, Alan , Killu, Ammar M, Hai, JoJo, Joppa, Stehpanie, Lin, Grace, Grogan, Martha, Brady, Peter, Killu, Ammar M. , Grogan, Martha , Dispenzieri, Angela

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.17403 Get It

Introduction: The T peak - T end interval (Tpe) is a measure of transmural dispersion of repolarisation with prolongation of this interval linked to an increased risk of ventricular arrhythmias and sudden death. Patients with cardiac amyloid experience a high rate of sudden cardiac death. Objective: To determine the prognostic utility of the Tpeak-Tend interval in patients with transthyretin (TTR) cardiac amyloidosis. Methods: Of the 240 patients who underwent evaluation for TTR amyloidosis at our tertiary referral center from 1966 to 2010, 39 met inclusion criteria (65 excluded for AF, 66 BBB/Paced Rhythm, 25 CAD, 21 other). Inclusion criteria were presence of histological diagnosis of TTR amyloid and confirmed cardiac involvement by echocardiogram or biopsy and absence of atrial fibrillation (AF) or bundle branch block/paced rhythm on the index surface ECG, or history of coronary heart disease (CAD). Tpe was measured in leads V3 and V5. Cox proportional hazards model were used to estimate hazard ratios (HR) and 95% confidence intervals (CI). Kaplan-Meier curves were used to estimate overall survival and differences between curves were estimated using log rank. Primary endpoints were death or heart transplantation. Results: Of the 39 patients, 85% were male, and 69% were mTTR. Mean age 66.4 ± 13.9 years. Mean follow up period of 4.2 ± 3.2 years, 25 died and 5 received heart transplants. Median survival was 3.8 years, with 5 year survival 34%. On univariate analysis, Tpe in lead V3 was predictive of adverse outcome, HR per 10msec, 1.195 (1.051-1.370). Further multivariate analysis, in a model accounting for age, gender, Lead V3 Tpe was independently associated with survival, HR per 10msec, 1.207, (1.094-1.411, p=0.009). Conclusions: The Tpe interval in Lead V3 at diagnosis is a novel, noninvasive independent predictor of survival in transthyretin cardiac amyloidosis patients in sinus rhythm.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation
Killu, Ammar M. , Sugrue, Alan , Hodge, David O. , Munger, Thomas M. , Mulpuru, Siva K. , Packer, Douglas L. , Friedman, Paul A. , Al‐Hijji, Mohammed , McLeod, Christopher J. , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112 Get It

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.
Sinus rhythm heart rate increase after atrial fibrillation ablation is associated with lower risk of arrhythmia recurrence
Killu, Ammar M. , Witt, Chance M. , Sugrue, Alan , Vaidya, Vaibhav R. , Monahan, Kristi H. , Lenz, Charles J., Yogeswaran, Vidhushei , Sun, Philip Y. , Hodge, David O. , Friedman, Paul A. , Packer, Douglas L. , Asirvatham, Samuel J. , Sugrue, Alan M, Vaidya, Vaibhav , Barnes, Stephanie, Friedman, Paul A , Asirvatham, Samuel J , Sun, Philip , Barnes, Stephanie

Pacing and Clinical Electrophysiology | February 17, 2021 | Volume: 44 | Issue: 4 | Pages: 651-656

10.1111/pace.14197 Get It

AbstractBackgroundPulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI.MethodsPatients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined.ResultsA total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre‐ablation and 76 ± 13 bpm post‐ablation (27% ± 24% increase, p < .001). The ability of relative HR change post‐ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41–1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome.ConclusionRelative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.
Sustained Improvement in Diastolic Reserve Following Percutaneous Pericardiotomy in a Porcine Model of Heart Failure With Preserved Ejection Fraction
Jain, C. Charles , Pedrotty, Dawn , Araoz, Philip A. , Sugrue, Alan , Vaidya, Vaibhav R. , Padmanabhan, Deepak , Lerman, Lilach O. , Asirvatham, Samuel J. , Borlaug, Barry A. , Arunachalam, Shivaram P. , Arunachalam, S P , Asirvatham, Samuel J , Borlaug, Barry A

Circulation: Heart Failure | January 22, 2021 | Volume: 14 | Issue: 2 | Pages: No page available

10.1161/circheartfailure.120.007530 Get It

Background: Heart failure with preserved ejection fraction is increasing in prevalence, but few effective treatments are available. Elevated left ventricular (LV) diastolic filling pressures represent a key therapeutic target. Pericardial restraint contributes to elevated LV end-diastolic pressure, and acute studies have shown that pericardiotomy attenuates the rise in LV end-diastolic pressure with volume loading. However, whether these acute effects are sustained chronically remains unknown. Methods: Minimally invasive pericardiotomy was performed percutaneously using a novel device in a porcine model of heart failure with preserved ejection fraction. Hemodynamics were assessed at baseline and following volume loading with pericardium intact, acutely following pericardiotomy, and then again chronically after 4 weeks. Cardiac structure was assessed by magnetic resonance imaging. Results: The increase in LV end-diastolic pressure with volume loading was mitigated by 41% (95% CI, 27%–45%, P <0.0001; ΔLV end-diastolic pressure reduced from +9±3 mm Hg to +5±3 mm Hg, P =0.0003, 95% CI, −2.2 to −5.5). The effect was sustained at 4 weeks (+5±2 mm Hg, P =0.28 versus acute). There was no statistically significant effect of pericardiotomy on ventricular remodeling compared with age-matched controls. None of the animals developed hemodynamic or pathological indicators of pericardial constriction or frank systolic dysfunction. Conclusions: The acute hemodynamic benefits of pericardiotomy are sustained for at least 4 weeks in a swine model of heart failure with preserved ejection fraction, without excessive chamber remodeling, pericarditis, or clinically significant systolic dysfunction. These data support trials evaluating minimally invasive pericardiotomy as a novel treatment for heart failure with preserved ejection fraction in humans.
A cool modality to restore sinus rhythm
Yasin, Omar , Sugrue, Alan , Zyl, Martin van , Ladejobi, Adetola, Tri, Jason , Rynbrandt, J, Seifert, Gregory J., Sanders, R., Pedersen, Joanne, Yngsdal, Lisa, Ladewig, Dorothy J., Taubel, R, Ritrivi, Charles, Asirvatham, S, Friedman, Paul A. , Rynbrandt, Jeff, Seifert, Greg

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0551 Get It

Abstract Background Slowing electrical conduction by cooling the myocardium can be used for defibrillation. We previously demonstrated the efficacy of a small cold device placed in oblique sinus (OS) in terminating atrial fibrillation (AF). However, the parameters needed to achieve effective atrial defibrillation are unknown. Purpose Assess effect of the size of cooled myocardium on frequency of AF termination in acute canine animal models. Methods Sternotomy was performed under general anesthesia in 10 acute canine experiments. AF was induced using rapid atrial pacing and intra-myocardial epinephrine and acetylcholine injections. Once AF sustained for at least 30s, either a cool (7–9°C) or placebo (body temperature) device was placed in the OS. Four device sizes were tested; ½X½, ¾X¾, and 1X1 inch devices and two ¾X¾ inch devices placed side by side simultaneously. Time to AF termination was recorded. Chi-squared or Fisher's exact test were used to compare the frequency of arrhythmia termination with cooling versus placebo. Results A total of 166 applications were performed (89 cool vs 77 placebo) in 10 animal experiments. Overall, AF terminated in 82% of the cooling applications vs. 67.5% of placebo (P=0.03, Figure 1). For the ½X½ inch device 88% of cold applications restored sinus rhythm vs. 63.6% for placebo (P=0.05). The frequency of sinus restoration for cold ¾X¾, 1X1 and two ¾X¾ side by side devices was 86.7%, 83.3% and 70% respectively. Time to sinus restoration when achieved was within three minutes was also not significantly changed. Conclusion Placing a cool device in the oblique sinus can terminate AF and efficacy is not affected by the size of device. Funding Acknowledgement Type of funding source: Private grant(s) and/or Sponsorship. Main funding source(s): MediCool Technologies
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Kuzmenko, Volodymyr , Sämfors, Sanna, Livia, Christopher , Vaidya, Vaibhav R. , Sugrue, Alan , Behfar, Atta , Asirvatham, Samuel J. , Gatenholm, Paul , Kapa, Suraj , van Zyl, Martin , Livia, Christopher , Vaidya, Vaibhav , Sugrue, Alan , Asirvatham, Samuel J , Gatenholm, Paul , Kapa, Suraj , Behfar, Atta , Karabulut, Erdem , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 Get It

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Karabalut, Erdem, mfors, Sanna S, Livia, Chris, Vaidya, Vaibhav R. , Sugrue, Alan , Gatenholm, Paul , Kuzmenko, Volodymyr , Livia, Christopher , McLeod, Christopher J. , Behfar, Atta , Asirvatham, Samuel J. , Kapa, Suraj

No container title available | July 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159406900.02369826 Get It

Abstract Introduction: Therapies for substrate-related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization. Methods: A nanocellulose-carbon nanotube conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue. Results: The conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The DC conductivity under aqueous conduction was 4.3·10-1 S/cm. In 4 canine hearts, when compared to the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation similar to baseline in all 4 hearts. Gross specimen examination demonstrated retention of the hydrogel within the tissue. Conclusions: This proof-of-concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long-term retention and biocompatibility of the hydrogel through in vivo experimentation.
P2862Complementary use of contact force and local catheter impedance during RF ablation reduces ablation time in an in vivo swine model
Garrott, Kara , Sugrue, Alan , Laughner, Jacob I. , Bush, J , Gutbrod, Sarah R., Sulkin, Matthew S. , Yasin, Omar , Meyers, Jason D., Garrott, Kara E. , Kapa, Suraj

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz748.1171 Get It

Abstract Catheter-tissue coupling is crucial for effective delivery of radiofrequency (RF) energy during catheter ablation. Force sensing catheters provide a metric of mechanical tissue contact and catheter stability, while local impedance has been shown to provide sensitive information on real-time tissue heating. The complementary use of force and local impedance during RF ablation procedures could provide an advantage over the use of one metric alone. This study evaluates a prototype ablation catheter that measures both contact force (CF) using inductive sensors and local catheter impedance (LI) using only catheter electrodes. The complementary nature was assessed with discrete lesions in vitro and an intercaval line in vivo. A force-sensing catheter with LI was evaluated in explanted swine hearts (n=14) in an in vivo swine model (n=9, 50–70kg) using investigational electroanatomical mapping software. In vitro, discrete lesions were created in ventricular tissue at a range of forces (0–40g) controlled externally. RF energy was applied at a range of powers (20W, 30W, and 40W), durations (10s-60s), and catheter orientations (0°, 45°, and 90°). Lesions were stained with TTC and measured. LI drop relative to baseline during RF in the bench studies was used to inform the in vivo study. In a separate subset of animals in vivo, an intercaval line was created in three experimental groups: LI blinded, 20Ω ΔLI, and 30Ω ΔLI. CF was maintained between 15 and 25g in all groups. All ablations were performed with a power of 30W. In the LI blinded group, all lesions were delivered for 30s. In the 20Ω ΔLI group, the investigator ablated until a 20Ω drop or 30 seconds was achieved. Likewise, in the 30Ω ΔLI, the investigator ablated until a 30Ω drop or 30 seconds was achieved. In vitro, 137 discrete ventricular lesions were created. LI drop during ablation correlated strongly with lesion depth using a monoexponential fit (R=0.84) while force time integral (FTI) did not correlate as strongly (R=0.56). In the intercaval LI blinded group, starting LI ranged from 126–163Ω with a median of 138Ω. LI drops ranged from 13Ω-44Ω, with a median of 26Ω. In the 20Ω ΔLI group, starting LI ranged from 137–211Ω with a median of 161Ω and LI drop ranged from 7Ω-35Ω, with a median of 22Ω. In the 30Ω ΔLI group, starting LI ranged from 130–256Ω with a median of 171Ω and LI drop ranged from 20Ω-52Ω, with a median of 31Ω. Notably, RF time for the LI blinded group was 13±0.1 minutes while RF time in the 20Ω ΔLI group was 6.4±1.9 minutes and 7.5±0.7 minutes in the 30Ω ΔLI group. A catheter incorporating CF-sensing and LI capabilities provides a powerful tool for RF ablation. Bench studies demonstrate a strong correlation between LI drop and lesion dimensions, which guided the use of LI in vivo. In vivo, the confirmation of stable mechanical contact and viewing of real-time LI drops enabled a significant reduction in RF time while creating a continuous intercaval line. Acknowledgement/Funding This study was funded by Boston Scientific.
Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models
Caluori, Guido , Wojtaszczyk, Adam , Yasin, Omar , Pešl, Martin , Wolf, Jiří , Bělašková, Silvie , Crha, Michal, Sugrue, Alan , Vaidya, Vaibhav R. , Naksuk, Niyada , Killu, Ammar M. , Padmanabhan, Deepak , Asirvatham, Samuel J. , Stárek, Zdeněk , DeSimone, Christopher V , Killu, Ammar M , Stárek, Zdeněk , Asirvatham, Samuel J , DeSimone, Christopher V.

Pacing and Clinical Electrophysiology | April 16, 2019 | Volume: 42 | Issue: 7 | Pages: 862-867

10.1111/pace.13698 Get It

Abstract Background Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. Methods We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine ( Sus Scrofa ) and canine ( Canis familiaris ) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. Results Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97‐164.69, animal‐based odds ratio [OR]: .55, 95% CI: .23‐61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35‐9.55; P = .010). Conclusions The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.