MRI-based numerical modeling of cardiac pulsed field ablation (PFA) with sub-microsecond pulses
Ladas, Thomas P. , Zyl, Martin van , Tan, Nicholas Y. , Christopoulos, Georgios , Tri, Jason , Yasin, Omar , Sugrue, Alan , Killu, Ammar M. , Munoz, Freddy Del‐Carpio , ASIRVATHAM, SAMUEL, Ivorra, A, García-Sánchez, Tomás , Connolly, Richard J. , DeSimone, Christopher V. , Asirvatham, Samuel J. , Ivorra, Antoni

European Heart Journal | October 15, 2022 | Volume: 43 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehac544.475 Get It

Abstract Background The use of irreversible electroporation (IRE) for cardiac ablation in the management of cardiac arrhythmias, known as Pulsed Field Ablation (PFA), has gained the attention of many researchers, physicians and companies. Despite the demonstrated efficacy and safety profiles of the technique, there are still many open questions. One of them deals with the effective electric field thresholds necessary for cardiac tissue ablation. Contrary to radiofrequency (RF) ablation, where the thermotemporal thresholds for tissue damage are well established, the electric field thresholds for effective IRE are uncertain and depend on the tissue type and the waveform characteristics of the delivered electric field. Purpose The use of numerical models to understand the electric field distribution and the corresponding lesion for a specific electrode geometry are widely used in IRE for cancer treatment. Models can predict ablation volumes when the field thresholds are known or can be used to estimate the field thresholds when the lesion geometry is established post-treatment. The goal of the present study was to build a subject-specific realistic 3D numerical model to assess the ability of modeling to predict PFA lesions. Methods PFA experiments were performed in male mongrel dogs following a protocol approved by the Mayo Clinic Institutional Animal Care and Use Committee. Briefly, animals were sedated and intubated, and two non-irrigated deflectable catheters with an 8-mm tip were positioned on both sides of the interventricular septum under fluoroscopy guidance. Submicrosecond pulses were delivered in a bipolar fashion across both catheters. Sequences of pulses of 300 ns duration (or other durations in that range) were repetitively applied with voltage levels in the kV range. 30 days after the procedure, MRI with late gadolinium enhancement (LGE) were acquired to assess the presence of ablation lesions in the treated tissue. Ventricular areas were segmented from MRI images and 3D volumes were created. The generated 3D geometries were imported into software COMSOL Multiphysics. Realistic 3D geometries of the catheters were placed in the same positions than during the experiments, fluoroscopy videos recorded during the procedures were used as a guidance. The computed electric field intensity distributions were compared to the LGE areas to extract the range of electric field thresholds where the predicted lesion size was compatible with the real size of the LGE areas for each application site and pulsing protocol. Results and conclusions Our results show how the numerical model is able to reproduce the shape of the LGE fibrotic lesion areas observed 30 days after the procedure. Additionally, the model clearly confirms the dose-dependent lesion sizes observed experimentally. This study supports that numerical modeling is a valuable tool for understanding PFA treatments and that it could be used as patient-specific treatment planning tool. Funding Acknowledgement Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Ladejobi, Adetola, Christopoulos, Georgios , Tan, Nicholas Y. , Ladas, Thomas P. , Tri, Jason , Zyl, Martin van , Yasin, Omar , Sugrue, Alan , Khabsa, Mariam , Uecker, Darrin, Danitz, David J., Killu, Ammar M. , Holmes, David R. , Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Tan, Nicholas , van Zyl, Martin , DeSimone, Christopher V , Killu, Ammar M , Maor, Elad , Holmes, David R , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Tri, Jason A , Christopoulos, Georgios, Connolly, Richard J. , DeSimone, Christopher V. , Maor, Elad

Circulation: Arrhythmia and Electrophysiology | October 4, 2022 | Volume: 15 | Issue: 10 | Pages: No page available

10.1161/circep.121.010668 Get It

Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 371: Assessment of Catheter Position Above or Below the Aortic Valve by Evaluation of Characteristics of the Local Electro Gram: an Acute Canine Study
Pa, Deepak, Witt, Chance M. , Sugrue, Alan , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dejae, Drakulic, Budimir , Foxall, Thomas, LADEWIG, DEJAE J., Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.371 Get It

Background: Ablation in the sinuses of Valsalva (SoV) within the aorta is fraught with risk, owing to the proximity of the coronary arteries. Assessment of catheter tip position is not very easy at this location owing to complex local anatomy and poor images from available modalities. Objectives: We propose the use of novel local unipolar electrogram characteristics using a new signal recording system to guide the assessment of catheter tip position in this region. Methods: We recorded unipolar signals from above the SoV, within the coronaries and below the SoV using the PURE-EP™ (BioSig Technologies, MN) signal processing system in 4 anesthetized canines in the setting of an acute study. We used fluoroscopy, intracardiac echocardiography and angiography for confirmation of the position of the catheter tip. We recorded changes in the signals when transitioning between (1) the coronary arteries and the SoV and (2) the SoV and below the SoV. Results: The unipolar signal showed a negative current of injury (COI) when the catheter tip was present in the SoV, whereas within the coronary artery or below the SoV, the COI was positive. We propose that the difference in the distribution of ventricular muscle below and above the SoV is responsible for this phenomenon. These changes in the COI were noted immediately when transitioning from one location to another and were present reproducibly in all the dogs. ( Figure 1 ) Conclusions: Analysis of the changes on the local electrogram can provide information about the location of the catheter tip which could prove critical in saving lives.
Abstract 17604: Identification of Genotype-specific Electrocardiogram Patterns in Long QT Syndrome Using a Novel, Automated T Wave Analysis Program
Sugrue, Alan , Qiang, Bo , Friedman, Paul A. , Ackerman, Michael J. , Bos, J. Martijn , Křemen, Václav , Qiang, Bo, Noseworthy, Peter A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.17604 Get It

Introduction: Congenital long QT syndrome (LQTS) is a sudden cardiac death-predisposing genetic disorder that has a characteristic electrocardiographic signature. Specific LQTS genotypes have been associated classically with different qualitative electrocardiographic ST - T wave patterns; however, clinical recognition of these patterns could be improved by an automated and quantitative method. We therefore aimed to use a novel, quantitative T wave morphological analysis technique from 12-lead surface ECGs to identify genotype specific LQTS ECG patterns. Methods: We analyzed a genotyped cohort of 420 patients (22 ± 15.7years, 43% male) with either LQT1 (61%) or LQT2 (39%). ECG analysis was conducted using a custom T wave program to automatically detect subtle changes in T wave morphology across all 12 Leads. Classification was performed using the top three T wave features in a linear discriminant classifier by 10x10 cross-validation. Results: The top three discriminant features were (1) a steeper T wave left slope for LQT1 in lead II (2950 vs 1700 mV/ms, p < 0.0001), (2) a greater center of gravity in 1st segment of T wave in lead aVR in LQT1 (0.248 vs 0.209, p<0.0001) and (3) a smaller Tpeak - Tend/QT ratio in lead aVR in LQT1 (0.20 vs 0.24, p<0.0001). Using these top three features, we were able to successfully differentiate LQT1 and LQT2 in 79% of cases (figure 1). Conclusions: An automated morphological T wave analysis was able to discriminate between the two most common LQTS genotypes. This novel method enhances phenotypic characterization of LQT and could have a significant clinical impact on the diagnosis and management of patients with suspected LQTS.
Leak closure following left atrial appendage exclusion procedures: A multicenter registry
Killu, Ammar M. , Adeola, Oluwaseun , Sugrue, Alan , Simard, Trevor , Friedman, Paul A. , Kawsara, Akram , Horton, Rodney , Natale, Andrea , Holmes, David R. , Sugrue, Alan M, Simard, Trevor , Kawsara, Akram , Holmes, David R , Natale, Andrea , Rocca, Domenico G. Della , Ellis, Christopher R. , Alkhouli, Mohamad

Catheterization and Cardiovascular Interventions | March 2, 2022 | Volume: 99 | Issue: 6 | Pages: 1867-1876

10.1002/ccd.30139 Get It

AbstractBackgroundThough infrequent, incomplete left atrial appendage closure (LAAC) may result from residual leaks. Percutaneous closure has been described though data is limited.MethodsWe compiled a registry from four centers of patients undergoing percutaneous closure of residual leaks following LAAC via surgical means or with the Watchman device. Leak severity was classified as none (no leak), mild (1–2 mm), moderate (3–4 mm), or severe (≥5 mm). Procedural and clinical success was defined as the elimination of leak or mild residual leak at the conclusion of the procedure or follow‐up, respectively.ResultsOf 72 (age 72.2 ± 9.2 years; 67% male) patients, 53 had undergone prior LAAC using the Watchman device and 19 patients surgical LAAC. Mean CHADS2‐VA2Sc score was 4.0 ± 1.8. The median leak size was 5 mm, range: 2–13). A total of 13 received Amplatzer Vascular Plug‐II, 18 received Amplatzer Duct Occluder‐II and 40 patients received coils. One underwent closure using a 21 mm‐Watchman. Procedural success was 94%. Zero surgical and nine Watchman patients (13%) had a residual leak at procedural‐end (five mild, three moderate, and one severe)—only one patient had no reduction in leak size. Overall leak size reduction was 94%. Two (3%) had intraoperative pericardial effusion. There were no device embolizations, device‐related thrombi, or procedural deaths. Clinical success was maintained at 94%. Two had cerebrovascular accidents—at 2 days (transient ischemic attack) and 10 months postprocedure. Two had major bleeding outside the 30‐day periprocedural window.ConclusionPercutaneous closure of residual leaks following left atrial appendage closure is feasible and associated with good outcomes. The procedural risk appears to be satisfactory.
Cardiac ablation with pulsed electric fields: principles and biophysics
Sugrue, Alan , Munoz, Freddy Del‐Carpio , Killu, Ammar M. , Asirvatham, Samuel J. , Del-Carpio Munoz, Freddy , Asirvatham, Samuel J , Maor, Elad

EP Europace | February 25, 2022 | Volume: 24 | Issue: 8 | Pages: 1213-1222

10.1093/europace/euac033 Get It

Abstract Pulsed electric fields (PEFs) have emerged as an ideal cardiac ablation modality. At present numerous clinical trials in humans are exploring PEF as an ablation strategy for both atrial and ventricular arrhythmias, with early data showing significant promise. As this is a relatively new technology there is limited understanding of its principles and biophysics. Importantly, PEF biophysics and principles are starkly different to current energy modalities (radiofrequency and cryoballoon). Given the relatively novel nature of PEFs, this review aims to provide an understanding of the principles and biophysics of PEF ablation. The goal is to enhance academic research and ultimately enable optimization of ablation parameters to maximize procedure success and minimize risk.
Regional and Temporal Variation of Ventricular and Conduction Tissue Activity During Ventricular Fibrillation in Canines
Tan, Nicholas Y. , Christopoulos, Georgios , Ladas, Thomas P. , Jiang, Zhi , Sugrue, Alan , Tri, Jason , Tolkacheva, Elena G. , Munoz, Freddy Del‐Carpio , McLeod, Christopher J. , Asirvatham, Samuel J. , Sugrue, Alan , Tri, Jason A , Del-Carpio Munoz, Freddy , DeSimone, Christopher V , Asirvatham, Samuel J , McLeod, Christopher J , DeSimone, Christopher V.

Circulation: Arrhythmia and Electrophysiology | September 27, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circep.121.010281 Get It

Background: Rigorous study of ventricular fibrillation (VF) is not feasible in humans. The spatiotemporal characteristics of prolonged VF remain undefined, limiting our understanding of this lethal rhythm. Methods: VF was mapped in 4 canines. The endocardial and epicardial left ventricle (LV) and right ventricle (RV) were sequentially mapped at 0 to 15, 15 to 30, 30 to 45, and 45 to 60 minutes post-induction. Ten consecutive beats were used to determine the average cycle length and regularity index of ventricular and His-Purkinje system signals in discrete regions during each time interval. Results: Average VF time was 58±12 minutes. The shortest ventricular cycle length was present in the RV apical region (70±10 msec) at 0 to 15 minutes and at 15 to 30 minutes (89±31 msec) and LV apical region at 45 to 60 minutes (242±163 msec). The His-Purkinje system cycle length was the shortest at the RV outflow tract (75±3 msec) at 0 to 15 minutes, RV inflow and free wall (89±12 msec) at 15 to 30 minutes, LV apical region (83±14 msec) at 30 to 45 minutes, and inferior and inferolateral LV (145±23 msec) at 45 to 60 minutes. Regularity index was the highest in the RV inflow and free wall (78%) at 0 to 15 minutes, RV apical region (86%) at 15 to 30 minutes, LV septum and epicardial anterior RV (80%) at 30 to 45 minutes, and anterior and anterolateral LV (75%) at 45 to 60 minutes. Conclusions: These data suggest significant regional changes in electrical activity throughout VF in canines. A transition of fastest electrical activity from RV to LV apical regions across VF was observed. These novel insights of the temporal and spatial changes of VF merit further evaluation in diseased hearts to assess for reproducibility of findings.
Abstract 60: Inducible Arrythmogenicity of Direct Current Electroporation Ablation: Insight from a Series of Acute Canine Studies
Sugrue, Alan , Witt, Chance M. , Padnanabhan, Deepak, Killu, Ammar M. , Naksuk, Niyada , DeSimone, Christopher V. , Kapa, Suraj , Asirvatham, Samuel J.

Circulation Research | July 3, 2021 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.60 Get It

Background: The use of direct current electroporation has the potential for significant utility because of its non-thermal approach to tissue destruction. However, the fear of inducibility of cardiac arrhythmias (particular ventricular fibrillation) when using electroporation remains of concern due to membrane poration and ion flux during periods of vulnerability occurring in ventricular repolarization. Objectives: Critically examine the incidence of arrhythmias in a series of acute canine studies to retrospectively determine cause and safe electoporative dosing margins. Methods: We performed electroporation ablation in 6 acute canine studies. These were experimental studies performed at sites critical in arrhytmogenesis. Sites included the pulmonary veins, left atrial appendage, superior vena cavae, right atrium and ventricle. Electroporation was delivered using an ECG gating algorithm so that QRS complexes are tagged and direct current energy is not delivered during the vulnerable portion of the T wave. Results: In 6 acute canine experiments, we delivered a total of 62 electroporation applications for ablation purposes. The average electroporation dosage delivered involved an average of 1427 Volts (range 750-3000 V), Pulse length of 100 ms, and number of pulses of 20.2 (range 10-100). AF was induced in 27.4% of electroporiatve applications. Atrial flutter/tachycardia occurred in 8.1%. VF occurred in only one application at a location of the left superior pulmonary vein. Conclusion: These data suggest that induction of VF is relatively uncommon with ECG gating and highlight its importance when using this modality. However, the induction of AF occurs with higher frequency. The actual mechanism as to why this occurs requires further systematic study.
Abstract 17597: Quantitative T Wave Analysis Can Identify Patients With Symptomatic Long QT Syndrome
Sugrue, Alan , Qiang, Bo , Friedman, Paul A. , Ackerman, Michael J. , Bos, J. Martijn , Křemen, Václav , Qiang, Bo, Noseworthy, Peter A.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.17597 Get It

Introduction: Long QT syndrome (LQTS) is a genetic disorder associated with abnormal ventricular repolarization and a predisposition for torsade de pointes and sudden cardiac death. Identification of markers to elucidate high risk patients is of major practical importance. Our aim was to use a novel, automated quantitative T wave analysis program to distinguish symptomatic from asymptomatic LQTS patients. Methods: We analyzed a genotyped cohort of 420 patients (22 ± 15.7years, 43% male) with either LQT1 (61%) or LQT2 (39%). ECG analysis was conducted using novel software that we created to automatically detect subtle changes in T wave morphology. Symptomatic patients were defined as those with a history of syncope or resuscitated cardiac arrest that was suspected of being LQTS triggered. Classification was performed using the top three T wave features in a linear discriminant classifier by 10x10 cross-validation. Results: Symptomatic LQT1 patients have a greater QTc duration in lead aVF (437 msec vs 416 msec, p <0.0001), a greater T wave center of gravity on the x axis (COGx) in lead V2 (0.304 vs 0.280, p <0.0001) and longer Tpeak-Tend/QT in lead II (0.208 vs 0.188, p < 0.0001) than asymptomatic patients with LQT1. Use of these 3 features enabled classification of symptomatic status in 72% of LQT1 cases, compared to 68% when QTc was used to classify alone. Symptomatic LQT2 patients had a longer QTc in Lead 1 (460 vs 418 msec, p < 0.0001), COGx in 4th segment of T wave was greater in lead V5 (0.399 vs 0.350, p<0.0001), and the Tpeak-Tend interval in V2 was longer (126 vs 99 msec, P =0.0004). Use of these 3 features enabled correct classification in 73% of LQT2 cases, compared to 67% when QTc was used alone. Conclusions: Application of an automated T wave analysis program was able to identify T wave features that distinguished the patients who presented as symptomatic LQTS, associated with syncope or resuscitated cardiac arrest. Use of these features could help assess arrhythmic risk and guide management strategies for patients with LQTS.