Back to Authors

Araoz, Philip A.

https://orcid.org/0000-0001-5465-7997

Mayo Clinic

Mayo Clinic

Citations 50

An under‐recognized phenomenon: Myocardial volume change during the cardiac cycle
Kumar, Vinayak , Rao, Chaitanya, Ryu, Alexander J. , Gibbons, Raymond J. , Chandrasekaran, Krishnaswamy , Asirvatham, Samuel J. , Araoz, Philip A. , Oh, Jae K. , Egbe, Alexander C. , Behfar, Atta , Anavekar, Nandan S., Behfar, Atta , Asirvatham, Samuel J , Kumar, Vinayak , Manduca, Armando , Ryu, Alexander J. , Gersh, Bernard J. , Borlaug, Barry A.

Echocardiography | June 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/echo.15093 Get It

Sustained Improvement in Diastolic Reserve Following Percutaneous Pericardiotomy in a Porcine Model of Heart Failure With Preserved Ejection Fraction
Jain, C. Charles , Pedrotty, Dawn , Araoz, Philip A. , Sugrue, Alan , Vaidya, Vaibhav R. , Padmanabhan, Deepak , Lerman, Lilach O. , Asirvatham, Samuel J. , Borlaug, Barry A. , Arunachalam, Shivaram P. , Arunachalam, S P , Asirvatham, Samuel J , Borlaug, Barry A

Circulation: Heart Failure | January 22, 2021 | Volume: 14 | Issue: 2 | Pages: No page available

10.1161/circheartfailure.120.007530 Get It

Background: Heart failure with preserved ejection fraction is increasing in prevalence, but few effective treatments are available. Elevated left ventricular (LV) diastolic filling pressures represent a key therapeutic target. Pericardial restraint contributes to elevated LV end-diastolic pressure, and acute studies have shown that pericardiotomy attenuates the rise in LV end-diastolic pressure with volume loading. However, whether these acute effects are sustained chronically remains unknown. Methods: Minimally invasive pericardiotomy was performed percutaneously using a novel device in a porcine model of heart failure with preserved ejection fraction. Hemodynamics were assessed at baseline and following volume loading with pericardium intact, acutely following pericardiotomy, and then again chronically after 4 weeks. Cardiac structure was assessed by magnetic resonance imaging. Results: The increase in LV end-diastolic pressure with volume loading was mitigated by 41% (95% CI, 27%–45%, P <0.0001; ΔLV end-diastolic pressure reduced from +9±3 mm Hg to +5±3 mm Hg, P =0.0003, 95% CI, −2.2 to −5.5). The effect was sustained at 4 weeks (+5±2 mm Hg, P =0.28 versus acute). There was no statistically significant effect of pericardiotomy on ventricular remodeling compared with age-matched controls. None of the animals developed hemodynamic or pathological indicators of pericardial constriction or frank systolic dysfunction. Conclusions: The acute hemodynamic benefits of pericardiotomy are sustained for at least 4 weeks in a swine model of heart failure with preserved ejection fraction, without excessive chamber remodeling, pericarditis, or clinically significant systolic dysfunction. These data support trials evaluating minimally invasive pericardiotomy as a novel treatment for heart failure with preserved ejection fraction in humans.
Extracting hypertrophic cardiomyopathy features from cardiac magnetic resonance reports by natural language processing
Dewaswala-Bhopalwala, N, Chen, Daoke , Bhopalwala, Huzefa , Pour, S Hossein, Ommen, Steve R. , Araoz, Philip A. , Ackerman, Michael J. , Arruda‐Olson, Adelaide M. , Chen, D, Pour, S Hossein, Moon, Sungrim , Bos, Daniël , Scott, Christopher G. , Geske, Jennifer R. , Noseworthy, Peter A. , Erickson, Bradley J. , Nishimura, Rick A.

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0199 Get It

Abstract Objective Determine if information regarding hypertrophic cardiomyopathy (HCM) can be accurately retrieved from cardiac magnetic resonance (CMR) reports using natural language processing (NLP). Background CMR imaging is used for diagnosis and risk stratification of HCM. Manual annotation of information from CMR is time-consuming. NLP is an artificial intelligence method for automating extraction of information from narrative text. Methods We identified 200 HCM patients who had CMR reports from 1998 to 2018. These patients were randomly allocated into training (100 patients with 185 CMR reports) and testing sets (100 patients with 206 reports). An NLP system with 2 tiers was developed; the first extracted information regarding HCM diagnosis while second extracted categorical or numeric concepts for HCM classification. NLP performance was compared with gold-standard manual annotation. Results NLP algorithms achieved very high performance across all concepts with mean positive predictive value (PPV) = 0.96. An outlier was the performance for abstracting the presence of an apical pouch from CMR reports, which had noticeably lower PPV= 0.78 which be attributed to the low number of cases with this finding. Conclusions The algorithms developed can be translated to clinical decision support systems to increase efficiency and contribute to improved quality of care. Funding Acknowledgement Type of funding source: Other. Main funding source(s): Study supported by the National Heart, Lung and Blood Institute of National Institutes of Health (K01HL124045), the Mayo Clinic Center for Clinical and Translational Science (CCaTS), and the Mayo Clinic K2R award. Content is solely the responsibility of authors and does not necessarily represent official views of the National Institutes of Health.
TURBINE‐MRE: A 3D hybrid radial‐Cartesian EPI acquisition for MR elastography
Sui, Yi , Arani, Arvin , Trzasko, Joshua D. , Murphy, Matthew C. , Rossman, Phillip J. , Glaser, Kevin J. , McGee, Kiaran P. , Manduca, Armando , Araoz, Philip A. , Arani, Arvin , Manduca, A , Sui, Yi , Ehman, Richard L. , Huston, John

Magnetic Resonance in Medicine | August 1, 2020 | Volume: 85 | Issue: 2 | Pages: 945-952

10.1002/mrm.28445 Get It

PurposeTo develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain.MethodThe proposed 3D TURBINE‐MRE is based on a spoiled gradient‐echo MRE sequence with the EPI readout radially rotating about the phase‐encoding axis to sample a full 3D k‐space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32‐channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin‐echo (SE) EPI‐MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE‐MRE images were off‐line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE‐EPI‐MRE and TURBINE‐MRE.ResultsThe 3D wave‐field images and the generated stiffness maps were comparable between TURBINE‐MRE and standard SE‐EPI‐MRE for the phantom and the volunteers. The Bland–Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943.ConclusionWe demonstrated the feasibility of the new TURBINE‐MRE sequence for acquiring the desired 3D wave‐field data and stiffness maps in a phantom and in‐vivo brains. This pilot study encourages further exploration of TURBINE‐MRE for functional MRE, free‐breathing abdominal MRE, and cardiac MRE applications.
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
MRI feature tracking strain is prognostic for all-cause mortality in AL amyloidosis
Illman, Jeffery E., Arani, Arvin , Chang, Ian C , Glockner, James F., Grogan, Martha , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Chang, Ian Cheng-Yi , Dispenzieri, Angela , Grogan, Martha , Araoz, Philip A , Arunachalam, Shivaram P. , Dispenzieri, Angela

Amyloid | May 7, 2018 | Volume: 25 | Issue: 2 | Pages: 101-108

10.1080/13506129.2018.1465406 Get It

Spontaneous coronary artery dissection: Acute findings on coronary computed tomography angiography
Akhtar, Nila J., Best, Patricia J.M. , Gulati, Rajiv , Araoz, Philip A. , Tweet, Marysia S. , Best, Patricia Jm, Hayes, Sharonne N.

European Heart Journal: Acute Cardiovascular Care | January 29, 2018 | Volume: 8 | Issue: 5 | Pages: 467-475

10.1177/2048872617753799 Get It

Background: The coronary computed tomography angiography features of acute spontaneous coronary artery dissection, an important cause of acute coronary syndrome in young women, have not been assessed. Methods: The “Virtual” Multicenter Mayo Clinic Spontaneous Coronary Artery Dissection Registry was established in 2010 and includes retrospective and prospective patient data. Retrospective assessment of acute coronary computed tomography angiography images was performed for 14 patients (16 vessels) who had images performed within two days of invasive coronary angiography diagnosis of acute spontaneous coronary artery dissection. Results: Four pertinent diagnostic coronary features of acute spontaneous coronary artery dissection were observed in order of prevalence: 1) abrupt luminal stenosis (64%); 2) intramural hematoma (50%); 3) tapered luminal stenosis (36%); and 4) dissection (14%). Additional findings include epicardial fat stranding (42%), coronary tortuosity (29%), and coronary bridge (14%). Fifty percent of patients had myocardial hypoperfusion in the myocardial distribution of the dissected coronary artery. Conclusions: We define key coronary computed tomography angiography features of acute spontaneous coronary artery dissection, the most common of which are abrupt luminal stenosis and intramural hematoma. Importantly, intramural hematoma appears similar to noncalcified atherosclerotic plaque, emphasizing the importance of invasive coronary angiography for acute diagnosis of spontaneous coronary artery dissection until the sensitivity and specificity of coronary computed tomography angiography is better understood.
Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Air Embolism: Diagnosis and Management
Malik, Neera, Claus, Paul, Illman, Jeffery E., Kligerman, Seth , Moynagh, Michael R., Levin, David L. , Woodrum, David A. , Arani, Arvin , Arunachalam, Shivaram P. , Araoz, Philip A. , Claus, Paul L, Arunachalam, S P , Arani, Arvin

Future Cardiology | June 23, 2017 | Volume: 13 | Issue: 4 | Pages: 365-378

10.2217/fca-2017-0015 Get It

Feasibility study of cardiac magnetic resonance elastography in cardiac amyloidosis
Chang, Ian C , Arani, Arvin , Arunachalam, Shivaram P. , Grogan, Martha , Araoz, Philip A. , Chang, Ian C Y, Poigai Arunachalam, Shivaram, Dispenzieri, Angela , Arunachalam, S P , Arani, Arvin

Amyloid | April 22, 2017 | Volume: 24 | Issue: sup1 | Pages: 161-161

10.1080/13506129.2017.1278689 Get It