Back to Authors

Cha, Yong‐Mei

https://orcid.org/0000-0002-5897-9464

Mayo Clinic

Mayo Clinic

Citations 164

Sound wave balloon-assisted device implantation: a novel approach that merits consideration
Barake, Walid , Madhavan, Malini , Kowlgi, Gurukripa N. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Asirvatham, Samuel J , Kowlgi, Narayan G

EP Europace | November 19, 2020 | Volume: 23 | Issue: 5 | Pages: 747-747

10.1093/europace/euaa281 Get It

Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience
Houmsse, Mahmoud , Karki, Roshan , Gabriels, James , Reinig, Michael, Patel, Dilesh, Hussain, Sarah, Gandhi, Gaurang , Lloyd, Michael S. , Patel, Apoor , Afzal, Muhammad R. , Cha, Yong‐Mei , Cha, Yong-Mei , Makary, Mina S. , Okabe, Toshimasa , Tamirisa, Kamala P. , Joza, Jacqueline E. , Epstein, Laurence M.

Journal of Cardiovascular Electrophysiology | October 15, 2020 | Volume: 31 | Issue: 12 | Pages: 3277-3285

10.1111/jce.14776 Get It

AbstractBackgroundThe leadless Micra transcatheter‐pacing system (Micra‐TPS) is implanted via a femoral approach using a 27‐French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters.ObjectiveTo examine the feasibility and safety of Micra‐TPS implantation through an IVC filter.MethodsThis multicenter retrospective study included patients with an IVC filter who underwent a Micra‐TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated.ResultsOf the 1528 Micra‐TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27‐Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6‐month follow‐up, there were no clinical complications related to the filter or the Micra‐TPS.ConclusionThis multicenter experience demonstrates the feasibility and safety of Micra‐TPS implantation via an IVC filter without acute procedural or delayed clinical complications.
Simultaneous coronary sinus and left bundle area pacing conferred cardiac resynchronization super response after either alone failed
Cha, Yong‐Mei , Liu, Xiaoke

No container title available | October 1, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.160157614.46548632 Get It

Background: A patient with ischemic cardiomyopathy and left bundle branch block (LBBB) who did not respond to standard bi-ventricular pacing underwent attempted left bundle area (LBA) pacing to achieve better cardiac resynchronization (CRT). Methods: LBA pacing failed to correct the LBBB or narrow the QRS. However, simultaneous pacing through the coronary sinus (CS) and LBA pacing leads resulted in marked shortening of the QRS Results: The patient’s EF improved from 30% to 45% two months post procedure and heart failure symptoms improved by one functional class. Conclusions: Simultaneous LBA and CS pacing may improve clinical outcomes compared to either alone.
Trends in reported industry payments to physicians practicing cardiac electrophysiology from 2013 to 2018 in the United States
Tseng, Andrew S. , Hu, Tiffany , Lee, Justin Z. , Amin, Mustapha, Vaidya, Vaibhav R. , Deshmukh, Abhishek , Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Mulpuru, Siva K. , Hu, Tiffany Y, Vaidya, Vaibhav , Tseng, A S , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | September 21, 2020 | Volume: 31 | Issue: 12 | Pages: 3106-3114

10.1111/jce.14754 Get It

AbstractIntroductionThe need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined.Methods and ResultsPayment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in‐depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165–$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik.ConclusionAmong cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.
Temporal Trends in the Incidence and Outcomes of Pacemaker Implantation After Transcatheter Aortic Valve Replacement in the United States (2012–2017)
Kawsara, Akram , Sulaiman, Samian , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong‐Mei , Rihal, Charanjit S. , Alkhouli, Mohamad , Alkhouli, Mohamad , Alqahtani, Fahad , Rihal, Charanjit S.

Journal of the American Heart Association | August 31, 2020 | Volume: 9 | Issue: 18 | Pages: No page available

10.1161/jaha.120.016685 Get It

Background Nationwide studies documenting temporal trends in permanent pacemaker implantation (PPMI) following transcatheter aortic valve replacement (TAVR) are limited. Methods and Results We selected patients who underwent TAVR between 2012 and 2017 in the National Readmission Database. The primary end point was the 6‐year trend in post‐TAVR PPMI at index hospitalization and at 30, 90, and 180 days after discharge. The secondary end point was the association between PPMI and in‐hospital mortality, stroke, cost, length of stay, and disposition. Among the 89 202 patients who underwent TAVR, 77 405 (86.8%) with no prior pacemaker or defibrillator were included. Patients who required PPMI had a higher prevalence of atrial fibrillation (43.6% versus 38.7%, P <0.001) and conduction abnormalities (28.4% versus 15.3%, P <0.001). The incidence of PPMI during index admission increased from 8.7% in 2012 to 13.2% in 2015, and then decreased to 9.6% in 2017. The incidence of inpatient PPMI within 30 days after discharge increased from 0.5% in 2012 to 1.25% in 2017 ( P trend <0.001). Inpatient PPMI beyond 30 days remained rare (<0.5%) during the study period. After risk adjustment, PPMI was not associated with in‐hospital mortality or stroke but was associated with increased nonhome discharge, longer hospitalization, and higher cost. The incremental expenditure associated with post‐TAVR PPMI during index admission increased from $9.6 million to $72.2 million between 2012 and 2017. Conclusions After an upward trend, rates of PPMI after TAVR in the United States stabilized at ~10% in 2016 to 2017, but there was a notable increase in PPMI within 30 days after the index admission. PPMI was not associated with increased in‐hospital morbidity or mortality but led to longer hospitalization, higher cost, and more nonhome discharges.
Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure
Yang, Mei , Li, Xuping , Liang, Jinjun, Deshmukh, Abhishek , Hodge, David O. , Li, Yi‐Gang , Cha, Yong‐Mei , III, John C. Morris

No container title available | August 29, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v3 Get It

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear.Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 350 patients (26.6%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was not associated with a higher risk of all-cause mortality in patients receiving CRT for heart failure. The risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid-stimulating hormone level in the entire cohort (hazard ratio, 1.23 per 5mIU/L increase; 95% CI, 1.01-1.5; P=0.04) as well as in the hypothyroid group (hazard ratio, 1.44 per 5mIU/L increase; 95% CI, 1.13-1.84; P=0.004). Conclusions CRT improves cardiac function in hypothyroid patients. The ventricular arrhythmic events requiring ICD therapies are associated with baseline TSH level, which might be considered as an important biomarker to stratify the risk of sudden death for patients with heart failure and hypothyroidism.
Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure
Yang, Mei , Li, Xuping , Liang, Jinjun, Deshmukh, Abhishek , Hodge, David O. , Li, Yi‐Gang , Cha, Yong‐Mei , III, John C. Morris

No container title available | August 13, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v2 Get It

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear. Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 350 patients (26.6%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was not associated with a higher risk of all-cause mortality in patients receiving CRT for heart failure. The risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid -stimulating hormone level in the entire cohort (hazard ratio, 1.23 per 5mIU/L increase; 95% CI, 1.01-1.5; P=0.04) as well as in the hypothyroid group (hazard ratio, 1.44 per 5mIU/L increase; 95% CI, 1.13-1.84; P=0.004). Conclusions CRT improves cardiac function in hypothyroid patients. The ventricular arrhythmic events requiring ICD therapies are associated with baseline TSH level, which might be considered as an important biomarker to stratify the risk of sudden death for patients with heart failure and hypothyroidism.
Transient Complete Heart Block After Alcohol Septal Ablation
Cha, Yong‐Mei , Klarich, Kyle W. , Rihal, Charanjit S. , Eleid, Mackram F. , El-Sabawi, Bassim, Bradley, David J. , El‐Sabawi, Bassim , Nishimura, Rick A. , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | August 6, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circinterventions.120.009202 Get It

Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
The portable device improves the detection of atrial fibrillation after ablation
Huang, Songqun , Liu, Chao , Qin, Aihong, Dong, Shaohua, Xing, Wenhui , Guo, Zhifu , huang, xin-miao, Cha, Yong‐Mei , Zhao, Teng , Yuan, Binhang , huang, xin-miao, Cao, Jiang

No container title available | August 4, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159657690.03276294 Get It

Background: Asymptomatic recurrences of atrial fibrillation (AF) are common after ablation of AF. Objective: We aimed to analyze the performance of the mobile ECG device using artificial intelligence (AI) algorithm in detection of AF after ablation. Method: A randomized controlled trial of AF screening using a handheld single-lead ECG monitor (BigThumb®) or a traditional follow-up strategy was conducted in patients with non-valvular AF after catheter ablation. Consecutive patients were randomized to either BigThumb Group (BT Group) or Traditional Follow-up Group (TF Group). Monitoring data was collected and analyzed. The ECGs collected by BigThumb were compared using the automated AF detection algorithm, AI algorithm and cardiologists’ manual review. Subsequent changes in adherence on oral anticoagulation of patients were also recorded. Result: We studied 218 patients (109 in BT Group, 109 in TF Group). After a follow-up of 345.4±60.2 days, AF-free survival rate was 64.2% in BT Group and 78.9% in TF Group (P=0.0163), with more adherence on oral anticoagulation in BT Group (P=0.0052). The participants in the BT Group recorded 26133 ECGs during the follow-up, among which 3299 (12.6%) were diagnosed as AF by cardiologists’ manual review. The sensitivity and specificity of the AI algorithm were 94.4% and 98.5% respectively, which are significantly higher than the automated AF detection algorithm (90.7% and 96.2%). Conclusion: We found that follow-up after AF ablation using BigThumb leads to a more frequent detection of AF recurrence and more adherence on oral anticoagulation. Artificial intelligence algorithm improves the accuracy of ECG diagnosis.