Back to Authors

Yang, Mei

https://orcid.org/0000-0001-5375-2263

Mayo Clinic

XinHua Hospital

Citations 7

Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure
Yang, Mei , Li, Xuping , Liang, Jinjun, Deshmukh, Abhishek , Hodge, David O. , Li, Yi‐Gang , Cha, Yong‐Mei , III, John C. Morris

No container title available | August 29, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v3 Get It

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear.Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 350 patients (26.6%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was not associated with a higher risk of all-cause mortality in patients receiving CRT for heart failure. The risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid-stimulating hormone level in the entire cohort (hazard ratio, 1.23 per 5mIU/L increase; 95% CI, 1.01-1.5; P=0.04) as well as in the hypothyroid group (hazard ratio, 1.44 per 5mIU/L increase; 95% CI, 1.13-1.84; P=0.004). Conclusions CRT improves cardiac function in hypothyroid patients. The ventricular arrhythmic events requiring ICD therapies are associated with baseline TSH level, which might be considered as an important biomarker to stratify the risk of sudden death for patients with heart failure and hypothyroidism.
Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure
Yang, Mei , Li, Xuping , Liang, Jinjun, Deshmukh, Abhishek , Hodge, David O. , Li, Yi‐Gang , Cha, Yong‐Mei , III, John C. Morris

No container title available | August 13, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v2 Get It

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear. Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 350 patients (26.6%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was not associated with a higher risk of all-cause mortality in patients receiving CRT for heart failure. The risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid -stimulating hormone level in the entire cohort (hazard ratio, 1.23 per 5mIU/L increase; 95% CI, 1.01-1.5; P=0.04) as well as in the hypothyroid group (hazard ratio, 1.44 per 5mIU/L increase; 95% CI, 1.13-1.84; P=0.004). Conclusions CRT improves cardiac function in hypothyroid patients. The ventricular arrhythmic events requiring ICD therapies are associated with baseline TSH level, which might be considered as an important biomarker to stratify the risk of sudden death for patients with heart failure and hypothyroidism.
Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure
Yang, Mei , Li, Xuping , Deshmukh, Abhishek , Hodge, David O. , Li, Yi‐Gang , Cha, Yong‐Mei , III, John C. Morris, Liang, Jinjun

No container title available | April 21, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v1 Get It

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear. Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 349 patients (26.5%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was associated with a greater all-cause mortality than euthyroidism (hazard ratio, 1.19; 95% CI, 1.01-1.38; P=0.04). In this group, the risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid-stimulating hormone level (hazard ratio, 1.27 per 5 mIU/L increase, 95% CI, 1.00-1.53, P=0.04). Conclusions Cardiac resynchronization therapy improves cardiac function in hypothyroid patients. Hypothyroidism has adverse effects on cardiac resynchronization therapy outcomes with reduced survival and increased implantable cardioverter-defibrillator therapies for ventricular arrhythmic events.
Stellate ganglion block and cardiac sympathetic denervation in patients with inappropriate sinus tachycardia
Cha, Yong‐Mei , Li, Xuping , Yang, Mei , Han, Jie , Wu, Gang , Noseworthy, Peter A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , Brady, Peter A. , Rho, Richard H., Friedman, Paul A. , Lee, Hon‐Chi, Tian, Ying , Zhou, Shenghua , Munger, Thomas M. , Ackerman, Michael J. , Shen, Win‐Kuang , Kapa, Suraj , Noseworthy, Peter A , Mulpuru, Siva K , Asirvatham, Samuel J , Friedman, Paul A , Zhou, Shenghua , Kapa, Suraj , McLeod, Christopher J. , Zhou, Shenghua

Journal of Cardiovascular Electrophysiology | October 18, 2019 | Volume: 30 | Issue: 12 | Pages: 2920-2928

10.1111/jce.14233 Get It

AbstractBackgroundInappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy.ObjectiveTo study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST.MethodsTwelve consecutive patients who had drug‐refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD.ResultsThe mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement.ConclusionSG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.
Cardiac resynchronization therapy improves myocardial conduction
Yang, Mei , Li, Xuping , Li, Yi‐Gang , Zhou, Shenghua , Liang, Jinjun , Wu, Gang , Munoz, Freddy Del‐Carpio , Chen, Horng H. , Friedman, Paul A. , Cha, Yong‐Mei , Yang, Dachun, Del-Carpio Munoz, Freddy , Friedman, Paul A , Cha, Yong-Mei , Yang, Dachun, Zhou, Shenghua

Pacing and Clinical Electrophysiology | December 13, 2018 | Volume: 42 | Issue: 2 | Pages: 238-246

10.1111/pace.13581 Get It

AbstractBackgroundCardiac resynchronization therapy (CRT) reverses left ventricular remodeling and improves left ventricular systolic function. However, little is known about whether CRT improves ventricular conduction.ObjectiveTo determine the relationship between CRT response and QRS narrowing.MethodsThe study included consecutive patients who underwent CRT with defibrillator (CRT‐D) implantation between January 2002 and December 2012 and had subsequent generator replacement (GR). At the time of GR, super‐responder was defined as those who had left ventricular ejection fraction (LVEF) of 50% or more; patients who had an LVEF of 36–49% with an increase of more than 5% were considered responders, and the others were nonresponders. All patients were assessed 6 months after CRT‐D implantation and at the time of GR.ResultsOf 114 study patients, 58 (50.9%) were nonresponders, 29 (25.4%) responders, and 27 (23.7%) super‐responders. QRS narrowing at 6 months was significant in super‐responders (175.4 ± 21.4 to 159.7 ± 20.7 ms, P = 0.001) and responders (169.0 ± 21.3 to 157.7 ± 17.6 ms, P = 0.008). At time of GR, only super‐responders had further QRS narrowing (159.7 ± 20.7 to 146.3 ± 19.2 ms, P < 0.001). QRS duration change after 6 months was independently associated with super‐response (hazard ratio: 1.20 for every 5 ms QRS duration narrowing; 95% confidence interval, 1.06–1.38; P = 0.005), and QRS narrowing of 10 ms or more was associated with lower risk of all‐cause mortality after GR.ConclusionContinuous QRS narrowing after CRT, as an electrical marker, is associated with a super‐response to CRT. Further QRS narrowing 6 months after CRT implantation was associated with lower risk of mortality after GR.
Outcomes of repeated transvenous lead extraction
Fu, Hai‐Xia , Ho, Gordon , Yang, Mei , Huang, Xinmiao, Fender, Erin A. , Mulpuru, Siva K. , Asirvatham, Roshini, Friedman, Paul A. , Birgersdotter‐Green, Ulrika , Cha, Yong‐Mei , Fu, Haixia, Mulpuru, Siva, Friedman, Paul A , Cha, Yong-Mei , Pretorius, Victor

Pacing and Clinical Electrophysiology | July 30, 2018 | Volume: 41 | Issue: 10 | Pages: 1321-1328

10.1111/pace.13464 Get It

AbstractIntroductionThe outcomes of repeated cardiovascular implantable electronic device (CIED) lead extraction have not been well studied. We sought to determine the indications, outcomes, and safety of repeated lead extraction procedures.MethodsThis retrospective study was conducted using data from two medical centers, including 38 patients who had undergone two or more lead extraction procedures compared to 439 patients who had a single procedure. The electronic medical records and procedural databases were reviewed to determine the indications, procedural characteristics, and outcomes. The outcomes of the first procedure were compared to the outcomes of subsequent procedures.ResultsThe 5‐year cumulative probability of a repeated extraction procedure was 11% (95% confidence interval, 7%–15%). In 439 patients who underwent single lead extractions, 72% had device and lead related infections as the procedure indication compared to 39% for 38 patients who underwent repeated extraction (P < 0.001). The mean duration from device reimplant to repeated extraction procedures was 63 ± 48 months. Ninety‐eight percent of the leads were removed completely in repeated procedures, similar to the 95% success rate of the first procedure (P = 0.51). There was no significant difference in major complication rate in the first or repeated extractions (2.6% vs 5.2%, P = 0.79).ConclusionsRepeated transvenous lead extraction is not uncommon. It had a high success rate comparable to that of the initial procedure and was not associated with an increased incidence of adverse events.
Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads
Yang, Mei , Li, Xuping , Liang, Jinjun , Asirvatham, Samuel J. , Espinosa, Raúl E. , Li, Yi‐Gang , Friedman, Paul A. , Cha, Yong‐Mei , Espinosa, Raul, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | May 25, 2018 | Volume: 41 | Issue: 8 | Pages: 912-919

10.1111/pace.13388 Get It

AbstractBackgroundQuadripolar left ventricular (LV) leads provide a more optimal pacing configuration for cardiac resynchronization therapy (CRT) than conventional bipolar leads. The objective of this study is to determine the clinical outcomes of CRT using quadripolar leads.MethodsThis study included 516 CRT patients who received bipolar LV leads (n = 278) or quadripolar LV leads (n = 238) from January 2013 to June 2016. Data were retrospectively collected from a prospective CRT database and electronic health records. CRT response to CRT was defined as >5% improvement in the LV ejection fraction (LVEF) from baseline. Baseline characteristics and outcomes were compared between groups.ResultsNew York Heart Association Functional Classification and LVEF significantly improved in the quadripolar and bipolar groups after CRT. There was no difference in the all‐cause mortality rate. The implant success rate was significantly higher in the quadripolar group (100% vs 97.8%; P = 0.02). Quadripolar lead placement was an independent predictor of CRT response at 12 months (hazard ratio, 0.76; 95% confidence interval, 0.58–0.98; P = 0.04). The rate of LV lead–related complications requiring invasive lead revision or abandonment was significantly higher in the bipolar group (11.2% vs 4.6%; P = 0.007).ConclusionsQuadripolar leads achieve similar CRT outcomes as bipolar LV leads but with a higher implant success rate and fewer procedure‐related complications.