Back to Authors

Cha, Yong‐Mei

https://orcid.org/0000-0002-5897-9464

Mayo Clinic

Mayo Clinic

Citations 164

Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads
Yang, Mei , Li, Xuping , Liang, Jinjun , Asirvatham, Samuel J. , Espinosa, Raúl E. , Li, Yi‐Gang , Friedman, Paul A. , Cha, Yong‐Mei , Espinosa, Raul, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | May 25, 2018 | Volume: 41 | Issue: 8 | Pages: 912-919

10.1111/pace.13388 Get It

AbstractBackgroundQuadripolar left ventricular (LV) leads provide a more optimal pacing configuration for cardiac resynchronization therapy (CRT) than conventional bipolar leads. The objective of this study is to determine the clinical outcomes of CRT using quadripolar leads.MethodsThis study included 516 CRT patients who received bipolar LV leads (n = 278) or quadripolar LV leads (n = 238) from January 2013 to June 2016. Data were retrospectively collected from a prospective CRT database and electronic health records. CRT response to CRT was defined as >5% improvement in the LV ejection fraction (LVEF) from baseline. Baseline characteristics and outcomes were compared between groups.ResultsNew York Heart Association Functional Classification and LVEF significantly improved in the quadripolar and bipolar groups after CRT. There was no difference in the all‐cause mortality rate. The implant success rate was significantly higher in the quadripolar group (100% vs 97.8%; P = 0.02). Quadripolar lead placement was an independent predictor of CRT response at 12 months (hazard ratio, 0.76; 95% confidence interval, 0.58–0.98; P = 0.04). The rate of LV lead–related complications requiring invasive lead revision or abandonment was significantly higher in the bipolar group (11.2% vs 4.6%; P = 0.007).ConclusionsQuadripolar leads achieve similar CRT outcomes as bipolar LV leads but with a higher implant success rate and fewer procedure‐related complications.
Downregulation of BK channel function and protein expression in coronary arteriolar smooth muscle cells of type 2 diabetic patients
Lü, Tong , Chai, Qiang , Jiao, Guoqing, Wang, Xiao-Li, Sun, Xiaojing , Furuseth, Jonathan D, Stulak, John M., Daly, Richard C. , Greason, Kevin L. , Cha, Yong‐Mei , Lee, Hon-Chi, Lu, Tong , Chai, Qiang, Wang, Xiao-Li

Cardiovascular Research | May 22, 2018 | Volume: 115 | Issue: 1 | Pages: 145-153

10.1093/cvr/cvy137 Get It

Abstract Aims Type 2 diabetes (T2D) is strongly associated with cardiovascular morbidity and mortality in patients. Vascular large conductance Ca2+-activated potassium (BK) channels, composed of four pore-forming α subunits (BK-α), and four regulatory β1 subunits (BK-β1), are densely expressed in coronary arterial smooth muscle cells (SMCs) and play an important role in regulating vascular tone and myocardial perfusion. However, the role of BK channels in coronary microvascular dysfunction of human subjects with diabetes is unclear. In this study, we examined BK channel function and protein expression, and BK channel-mediated vasodilation in freshly isolated coronary arterioles from T2D patients. Methods and results Atrial tissues were obtained from 16 patients with T2D and 25 matched non-diabetic subjects during cardiopulmonary bypass procedure. Microvessel videomicroscopy and immunoblot analysis were performed in freshly dissected coronary arterioles and inside-out single BK channel currents was recorded in enzymatically isolated coronary arteriolar SMCs. We found that BK channel sensitivity to physiological Ca2+ concentration and voltage was downregulated in the coronary arteriolar SMCs of diabetic patients, compared with non-diabetic controls. BK channel kinetics analysis revealed that there was significant shortening of the mean open time and prolongation of the mean closed time in diabetic patients, resulting in a remarkable reduction of the channel open probability. Functional studies showed that BK channel activation by dehydrosoyasaponin-1 was diminished and that BK channel-mediated vasodilation in response to shear stress was impaired in diabetic coronary arterioles. Immunoblot experiments confirmed that the protein expressions of BK-α and BK-β1 subunits were significantly downregulated, but the ratio of BK-α/BK-β1 was unchanged in the coronary arterioles of T2D patients. Conclusions Our results demonstrated for the first time that BK channel function and BK channel-mediated vasodilation were abnormal in the coronary microvasculature of diabetic patients, due to decreased protein expression and altered intrinsic properties of BK channels.
Ventricular Electrical Activation Delay and High-Frequency Electrocardiograms
Killu, Ammar M. , Cha, Yong‐Mei

Circulation: Arrhythmia and Electrophysiology | April 26, 2018 | Volume: 11 | Issue: 5 | Pages: No page available

10.1161/circep.118.006396 Get It

Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Ryan, J. , Tempel, Nathan D., Engle, Dean D., Hayes, David L. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Ryan, James D , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 1, 2018 | Volume: 41 | Issue: 3 | Pages: 340-340

10.1111/pace.13290 Get It

Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Padmanabhan, Deepak , Jondal, Mary Lou, Hodge, David O. , Mehta, Ramila A. , Acker, Nancy G., Dalzell, Connie, Asirvatham, Samuel J. , Cha, Yong‐Mei , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Jondal, Mary L, Dalzell, Connie M, Kapa, Suraj , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 Get It

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Ryan, J. , Tempel, Nathan D., Engle, Dean D., Hayes, David L. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Ryan, James D , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | January 10, 2018 | Volume: 41 | Issue: 2 | Pages: 161-166

10.1111/pace.13269 Get It

AbstractBackgroundTransthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.ObjectiveWe report an increased incidence of TIM oversensing.MethodRetrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.ResultsWe have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.ConclusionOversensing with pacing inhibition is apparent with the potential of adverse effects to patients.
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures
Lee, Justin Z. , Ling, Jayna, Diehl, Nancy N. , Hodge, David O. , Padmanabhan, Deepak , Killu, Ammar M. , Madhavan, Malini , Cha, Yong‐Mei , Deshmukh, Abhishek , Shen, Win-Kuang, Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Packer, Douglas L. , Mulpuru, Siva K. , Kapa, Suraj , Asirvatham, Samuel J , Noseworthy, Peter A. , McLeod, Christopher J. , Srivathsan, Komandoor , Kusumoto, Fred

Circulation | October 18, 2017 | Volume: 137 | Issue: 1 | Pages: 24-33

10.1161/circulationaha.117.030523 Get It

Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Super-response to cardiac resynchronization therapy reduces appropriate implantable cardioverter defibrillator therapy
Killu, Ammar M. , Mazo, Anna, Grupper, Avishay , Madhavan, Malini , Webster, Tracy L., Brooke, Kelly L., Hodge, David O. , Asirvatham, Samuel J. , Friedman, Paul A. , Glikson, Michael , Cha, Yong‐Mei , Webster, Tracy, Asirvatham, Samuel J , Glikson, Michael

EP Europace | August 4, 2017 | Volume: 20 | Issue: 8 | Pages: 1303-1311

10.1093/europace/eux235 Get It

Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Zyl, Martin van , Aung, Htin , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Mulpuru, Siva K. , Cha, Yong‐Mei , Espinosa, Raúl E. , Asirvatham, Samuel J. , McLeod, Christopher J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 Get It

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.