Back to Authors

Abdel, Matthew P.

https://orcid.org/0000-0002-2398-1724

Mayo Clinic

Mayo Clinic

Citations 229

What factors drive polyethylene wear in total knee arthroplasty?
Currier, Barbara H. , Berry, Daniel J. , Titus, Alexander , Currier, Barbara H , Berry, Daniel J , Currier, John H. , Abdel, Matthew P. , Citters, Douglas W. Van

The Bone & Joint Journal | November 1, 2021 | Volume: 103-B | Issue: 11 | Pages: 1695-1701

10.1302/0301-620x.103b11.bjj-2020-2334.r1 Get It

Aims Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. Methods An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. Results Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. Conclusion This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695–1701.
Are Serum Ion Levels Elevated in Pediatric Patients With Metal Implants?
Mathew, Smitha , Xie, Yong, Bagheri, Leila, Claton, Liam E. , Chu, Lin, Badreldin, Amr, Wijnen, André J. van , Haft, Geoffrey F. , Milbrandt, Todd A. , van Wijnen, Andre J , Chu, Lin, Badreldin, Amr A. , Abdel, Matthew P. , Larson, A. Noelle

Journal of Pediatric Orthopaedics | October 8, 2021 | Volume: 42 | Issue: 3 | Pages: 162-168

10.1097/bpo.0000000000001957 Get It

Background: Previous studies report elevated serum titanium (Ti) levels in children with spinal implants. To provide additional data on this topic, we sought to assess serum ion levels at multiple timepoints in pediatric patients with growing spine devices, spinal fusion instrumentation, and extremity implants placed for fracture treatment. We hypothesized that serum Ti, cobalt (Co), and chromium (Cr) levels would be elevated in pediatric patients with growing spine devices compared with patients with extremity implants. Methods: Pediatric patients undergoing any primary spine implant placement, those with spine implant revision or removal surgery and patients with other appendicular implant removal had serum Ti, Co, and Cr ion levels drawn at the time of surgery. Fifty-one patients (12 growing spine devices, 13 fusions, and 26 extremity implants) had one set of labs, 31 of whom had labs drawn both preoperatively and postoperatively. Biopsies obtained from tissue specimens at the time of implant revision were analyzed histologically for the presence of metal debris and macrophage activity. Results: Patients with growing spine implants had elevated serum Ti (3.3 vs. 1.9 ng/mL, P=0.01) and Cr levels (1.2 vs. 0.27 ng/mL, P=0.01) in comparison to patients with fusion rods or extremity implants. With respect to patients with extremity implants, patients with growing spine devices had elevated serum Ti (3.3 vs. 0.98 ng/mL, P=0.013), Co (0.63 vs. 0.26 ng/mL, P=0.017), and Cr levels (1.18 vs. 0.26 ng/mL, P=0.005). On matched pairs analysis, patients who had labs drawn before and after spine implantation had significant increase in serum Ti levels (0.57 vs. 3.3 ng/mL, P=0.02). Histology of tissue biopsies adjacent to growing spine implants showed presence of metal debris and increased macrophage activity compared with patients with extremity implants. Conclusion: Serum Ti, Co, and Cr levels are elevated in children with spinal implants compared with those with extremity implants, particularly in those with growing spine devices. However, the clinical significance of these findings remains to be determined. Level of Evidence: Level II—prospective comparative study.
Outcomes of Primary Total Knee Arthroplasty Following Septic Arthritis of the Native Knee
Bettencourt, Jacob W. , Wyles, Cody C. , Fruth, Kristin M. , Osmon, Douglas R. , Hanssen, Arlen D. , Berry, Daniel J. , Abdel, Matthew P. , Abdel, Matthew P , Osmon, Douglas R , Wyles, Cody C , Berry, Daniel J

Journal of Bone and Joint Surgery | September 15, 2021 | Volume: 103 | Issue: 18 | Pages: 1685-1693

10.2106/jbjs.20.01678 Get It

Background: Septic arthritis of the native knee often results in irreversible joint damage leading to the need for total knee arthroplasty (TKA). The purpose of the present study was to examine the intermediate-term risk of periprosthetic joint infection (PJI), aseptic revision, and reoperation following primary TKA in patients with a history of septic arthritis of the native knee as compared with primary TKA performed for the treatment of osteoarthritis. Methods: We retrospectively identified 215 primary TKAs performed from 1971 to 2016 at a single institution in patients with a history of septic arthritis of the native knee. Each case was matched 1:1 based on age, sex, body mass index (BMI), and surgical year to a TKA for osteoarthritis. The mean age and BMI were 63 years and 30 kg/m 2 , respectively. The mean duration of follow-up was 9 years. Results: Survivorships free of PJI at 10 years were 90% and 99% for the septic arthritis and osteoarthritis groups, respectively (hazard ratio [HR] = 6.1; p < 0.01). Ten-year survivorships free of any aseptic revisions were 83% and 93% (HR = 2.5; p < 0.01), and survivorships free of any reoperation were 61% and 84% (HR = 2.9; p < 0.01) for the septic arthritis and osteoarthritis groups, respectively. In addition, as time from the diagnosis of native knee septic arthritis to TKA increased, the relative risk of subsequent infection decreased. Preoperative and 2-year postoperative Knee Society scores were similar between the groups (p = 0.16 and p = 0.19, respectively). Conclusions: There was a 6.1-fold increased risk of PJI in patients undergoing TKA with a history of native knee septic arthritis when compared with controls undergoing TKA for the treatment of osteoarthritis, with a cumulative incidence of 9% at 10 years. Subgroup analysis of the septic arthritis cohort revealed a higher risk of any infection in patients who underwent TKA within the first 5 to 7 years after the diagnosis of septic arthritis as compared with those with a greater duration. Moreover, the 10-year rates of survival free of aseptic revision, any revision, and any reoperation were significantly worse in the native knee septic arthritis cohort. Level of Evidence: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Tranexamic Acid Was Not Associated with Increased Complications in High-Risk Patients with Hip Fracture Undergoing Arthroplasty
Spaulding, Aaron , Duncan, Christopher M. , Wilke, Benjamin K. , Pagnano, Mark W. , Abdel, Matthew P. , Porter, Steven B , Spaulding, Aaron , Duncan, Christopher M , Wilke, B K , Pagnano, Mark W , Abdel, Matthew P , Porter, Steven B.

Journal of Bone and Joint Surgery | August 27, 2021 | Volume: 103 | Issue: 20 | Pages: 1880-1889

10.2106/jbjs.21.00172 Get It

Background: Tranexamic acid (TXA) is considered safe and efficacious for elective total joint arthroplasty. However, evidence of TXA’s safety in high-risk patients with hip fracture requiring nonelective arthroplasty has been lacking. This study aimed to assess whether TXA administration to high-risk patients with a hip fracture requiring arthroplasty increased the risk of thrombotic complications or mortality. Methods: All patients who underwent hip hemiarthroplasty (HHA) or total hip arthroplasty (THA) for displaced femoral neck fractures between 2011 and 2019 at 4 sites within 1 hospital system were retrospectively identified. Patients were grouped by risk (high-risk or low-risk) and TXA treatment (with or without TXA). Propensity scores were used for risk adjustment in comparisons between surgery with and without TXA for only the high-risk group (n = 1,066) and the entire population (n = 2,166). Differences in the occurrence of postoperative mortality, deep venous thrombosis, pulmonary embolism, myocardial infarction, and stroke within 90 days of hip arthroplasty were evaluated. Results: TXA administration was not associated with an increased risk of thrombotic complications or mortality within 90 days in either high-risk or all-patient groups. Specifically, among 1,066 matched high-risk patients who did not or did receive TXA, there were no significant differences in mortality (14.82% and 10.00%; p = 0.295), deep venous thrombosis (3.56% and 3.04%; p = 0.440), pulmonary embolism (2.44% and 1.96%; p = 0.374), myocardial infarction (3.38% and 2.14%; p = 0.704), or stroke (4.32% and 5.71%; p = 0.225). Conclusions: In our review of 1,066 propensity-matched high-risk patients undergoing hip arthroplasty for displaced femoral neck fractures, we found that TXA administration (compared with no TXA administration) was not associated with an increased risk of mortality, deep venous thrombosis, pulmonary embolism, myocardial infarction, or stroke. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Toward a Genetic Crystal Ball for Patients with Rotator Cuff Disease
Wijnen, André J. van , Abdel, Matthew P. , van Wijnen, Andre J , Abdel, Matthew P

Journal of Bone and Joint Surgery | July 14, 2021 | Volume: 103 | Issue: 14 | Pages: e55

10.2106/jbjs.21.00434 Get It

In Vitro Activity of Rifampin, Rifabutin, and Rifapentine against Enterococci and Streptococci from Periprosthetic Joint Infection
Albano, Mariana , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Osmon, Douglas R. , Oravec, Caitlin P., Berry, Daniel J. , Patel, Robin , Patel, Robin , Berry, Daniel J , Abdel, Matthew P.

Microbiology Spectrum | July 14, 2021 | Volume: 9 | Issue: 1 | Pages: No page available

10.1128/spectrum.00071-21 Get It

Rifampin is an antibiotic with antistaphylococcal biofilm activity used in the management of staphylococcal periprosthetic joint infection with irrigation and debridement with component retention; some patients are unable to receive rifampin due to drug interactions or intolerance. We recently showed rifabutin and rifapentine to have in vitro activity against planktonic and biofilm states of rifampin-susceptible periprosthetic joint infection-associated staphylococci.
Abstract 17269: Incidence of Atrial Fibrillation in Patients With Cobalt and Chromium Containing Hip Arthroplasty
Sharma, Sunita , Ponamgi, Shiva , Sun, Philip Y. , Yogeswaran, Vidushei, Padmanabhan, Deepak , El‐Harasis, Majd , Hodge, David O. , Slusser, Joshua P. , Asirvatham, Samuel, Sun, Philip , DeSimone, Christopher V. , Wyles, Cody C. , Abdel, Matthew P.

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17269 Get It

Background: Worldwide, approximately one million patients have had total hip arthroplasty with 35% being cobalt and chromium Metal-on-Metal (MoM) or Metal-on-Polythelene (MoP) implants. Animal models have suggested that cobalt and chromium can affect all chambers, but there seems to be an atrial predilection. There are several case reports of metal containing hip arthroplasty causing atrial arrhythmias but the true incidence of atrial fibrillation associated with metal hip arthroplasty remains undefined. Objective: We sought to determine the incidence of atrial fibrillation in patients with metal containing hip arthroplasty. We also examined the association between serum cobalt and chromium levels and arrhythmias in this cohort and all cause mortality. Methods: We retrospectively examined the records of patients from the Mayo Clinic total hip arthroplasty registry (Metal group - Metal-on-Metal: MoM and Metal-on-Polyethylene: MoP, Non-Metal group - Ceramic-on-Ceramic: CoC and Ceramic-on-Polyethylne: CoP) to obtain demographic data, comorbidities, laboratory, ECG, and echocardiographic data. Out of a total of 1756 patients, Cobalt and Chromium levels were available in 138 patients. Results: The mean age of patients with metal containing hip replacement was 50 years and were predominantly male. During a follow up period of 10 years, the incidence of atrial fibrillation in our study population was 8% in metal group compared to 2% (p=0.11) in non-metal group. There was no association between cobalt or chromium levels with the incidence of atrial fibrillation. All-cause mortality was significantly higher in metal group versus non-metal group (p=0.005). Conclusion: The incidence of atrial fibrillation was relatively more in patients with metal versus non-metal hip arthroplasty but there was no association of serum cobalt or chromium levels with incidence of atrial fibrillation in the subset of patients. In addition, all-cause mortality was significantly higher in the metal group suggesting potential toxic effects of metal containing hip arthroplasty.
Outcomes of operatively treated interprosthetic femoral fractures
Tibbo, Meagan E. , Limberg, Afton K. , Huang, Phil, Perry, Kevin I. , Berry, Daniel J. , Gausden, Elizabeth B. , Yuan, Brandon J. , Berry, Daniel J , Abdel, Matthew P.

The Bone & Joint Journal | July 1, 2021 | Volume: 103-B | Issue: 7 Supple B | Pages: 122-128

10.1302/0301-620x.103b7.bjj-2020-2275.r1 Get It

AimsThe prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes.MethodsA total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m2(21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24).ResultsOverall, 59 fractures were classified as Vancouver C (Unified Classification System (UCS) D), 17 were Vancouver B (UCS B). In total, 57 patients (75%) were treated with open reduction and internal fixation (ORIF); three developed nonunion, three developed periprosthetic joint infection, and two developed aseptic loosening. In all, 18 patients (24%) underwent revision arthroplasty including 13 revision THAs, four distal femoral arthroplasties (DFAs), and one revision TKA: of these, one patient developed aseptic loosening and two developed nonunion. Survivorship free from any reoperation was 82% (95% confidence interval (CI) 66.9% to 90.6%) and 77% (95% CI 49.4% to 90.7%) in the ORIF and revision groups at two years, respectively. ORIF patients who went on to union tended to have stemmed knee components and greater mean interprosthetic distance (IPD = 189 mm (SD 73.6) vs 163 mm (SD 36.7); p = 0.546) than nonunited fractures. Patients who went on to nonunion in the revision arthroplasty group had higher medullary diameter: cortical width ratio (2.5 (SD 1.7) vs 1.3 (SD 0.3); p = 0.008) and lower IPD (36 mm (SD 30.6) vs 214 mm (SD 32.1); p < 0.001). At latest follow-up, 95% of patients (n = 72) were ambulatory.ConclusionInterprosthetic femur fractures are technically and biologically challenging cases. Individualized approaches to internal fixation versus revision arthroplasty led to an 81% (95% CI 68.3% to 88.6%) survivorship free from reoperation at two years with 95% of patients ambulatory. Continued improvements in management are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):122–128.
Isolated tibial insert exchange in revision total knee arthroplasty
Tetreault, Matthew W. , Hines, Jeremy T. , Berry, Daniel J. , Pagnano, Mark W. , Trousdale, Robert T. , Abdel, Matthew P. , Abdel, Matthew P , Berry, Daniel J

The Bone & Joint Journal | June 1, 2021 | Volume: 103-B | Issue: 6 | Pages: 1103-1110

10.1302/0301-620x.103b6.bjj-2020-1954.r2 Get It

AimsThis study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA).MethodsFrom 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded.ResultsSurvivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years.ConclusionAfter ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110.
Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis
Ivy, Morgan I. , Sharma, Katyayini , Greenwood‐Quaintance, Kerryl E. , Tande, Aaron J. , Osmon, Douglas R. , Berbari, Elie F. , Mandrekar, Jay , Beauchamp, C.P., Hanssen, Arlen D. , Abdel, Matthew P. , Lewallen, David G. , Perry, Kevin I. , Block, Darci R , Snyder, Melissa R. , Patel, Robin , Mandrekar, Jayawant N. , Beauchamp, Christopher P., Perry, Kevin, Tande, Aaron , Patel, Robin , Abdel, Matthew P , Osmon, Douglas R , Greenwood-Quaintance, Kerryl

The Bone & Joint Journal | June 1, 2021 | Volume: 103-B | Issue: 6 | Pages: 1119-1126

10.1302/0301-620x.103b6.bjj-2020-1741.r1 Get It

Aims The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126.