Department of Orthopaedic Surgery, Mayo Clinic, Rochester, Minnesota.
Citations 2
Synovial fluid α defensin has comparable accuracy to synovial fluid white blood cell count and polymorphonuclear percentage for periprosthetic joint infection diagnosis
Aims The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm3 and ≥ 65% for TKA and ≥ 3,000 cells/mm3 and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126.
The Effects of Resection Technique on Implant Migration in Single Radius Posterior-Stabilized Total Knee Replacement
AbstractThe purpose of the present study was to measure the effects of gap balancing and resection techniques on migration of a single total knee replacement implant design. A total of 23 patients (24 knees) were recruited on referral to either a surgeon performing gap balancing or a surgeon performing measured resection and followed prospectively. All patients received a fixed bearing, posterior stabilized total knee replacement implant of a single radius femoral component design with cement fixation, and all aspects of care outside of resection technique were identical. Patients underwent radiostereometric analysis (RSA) at 2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years. Migration of the tibial and femoral components was compared between groups. Tibial component migration was greater at 2 years in the gap balancing group (mean difference = 0.336 mm, p = 0.036), but there was no difference at 1 year. One measured resection and three gap balancing tibial components demonstrated continuous migration > 0.2 mm between years 1 and 2. There was no difference in femoral component migration. Small differences in tibial component migration were found between the gap balancing and measured resection techniques. However, comparing the migration to established predictive thresholds for long-term loosening risk, implants performed with both techniques were found to have equally low revision risk.