Back to Authors

Perry, Kevin I.

https://orcid.org/0000-0003-1457-442X

Mayo Clinic

Mayo Clinic

Citations 41

Five-year survival and complications of more than 300 articulating high-dose antibiotic spacers in two-stage revision total hip arthroplasties for infection
Weintraub, Matthew T. , Midthun, William R., Pagnano, Mark W., Taunton, Michael J. , Sierra, Rafael J. , Mabry, Tad M. , Perry, Kevin I. , Abdel, Matthew P. , Abdel, Matthew P , Sierra, Rafael J , Taunton, Michael J , Pagnano, Mark W. , Berry, Daniel J.

The Bone & Joint Journal | September 1, 2026 | Volume: 108-B | Issue: 9 | Pages: 1104-1112

10.1302/0301-620x.108b9.bjj-2026-0551.r1 Get It

Aims Two-stage exchange arthroplasty with an antibiotic-eluting cement spacer remains the predominant strategy in the USA for managing chronic periprosthetic joint infection (PJI) following total hip arthroplasty (THA). The aim of this study was to evaluate a commercially available, partially intraoperatively fabricated articulating high-dose antibiotic cement spacer, focusing on survival, complications, and patient-reported outcomes. Methods A total of 298 patients (302 THAs) underwent two-stage exchange arthroplasty for PJI using a specific articulating antibiotic spacer between August 2005 and May 2022. Patients with a previous failed two-stage exchange were excluded, although 121 THAs (302, 40%) had undergone previous PJI-related procedures. The mean age of the patients was 65 years (SD 11), the mean BMI was 32 kg/m 2 (SD 7), and 116 (38%) were female. Most patients were classified as McPherson host B (158; 52%) and limb grade 2 (165; 55%), and 265 (88%) met the 2011 Musculoskeletal Infection Society criteria. The mean follow-up was six years (2 to 16). Results At five years after reimplantation, survival free of reinfection, aseptic rerevision, any rerevision, or any reoperation were 89% (95% CI 85.2 to 93.1), 93% (95% CI 89.3 to 96.1), 86% (95% CI 81.3 to 90.3), and 80% (95% CI 74.7 to 84.9), respectively. Dislocation accounted for most aseptic rerevisions (15/20). McPherson host C (HR 3.7 (95% CI 1.4 to 9.6); p = 0.007) and limb grade 3 (HR 3.3 (95% CI 1.0 to 11.1); p = 0.049) were significantly associated with an increased risk of reinfection. The mean Harris Hip Score at the latest follow-up was 76 (29 to 100). A total of 17 patients underwent revision or removal of a spacer for concerns about persistent infection and two for dislocation of the spacer. Eight patients underwent a non-rerevision reoperation during the spacer interval for wound drainage (n = 5), dislocation of the spacer (n = 2), and perispacer fracture (n = 1). A total of 26 spacer-related complications were treated nonoperatively (15 perispacer fractures, 11 dislocations). Dislocation of the spacer was strongly associated with dislocation after reimplantation (HR 6.2 (95% CI 2.3 to 16.9); p < 0.001). Conclusion This commercially available, partially intraoperatively fabricated articulating spacer showed excellent reinfection-free five-year survival (89%). Spacer-related fracture and dislocation each occurred in 5% of patients. Dislocation of the spacer significantly increased the risk of dislocation following reimplantation, supporting the use of higher-stability bearings in these high-risk patients. Cite this article: Bone Joint J 2026;108-B(9):1104–1112.
Full and Half Cup-Cage Reconstruction of Major Acetabular Defects
Berdis, Galen , Carstens, Mason , Larson, Dirk R. , Perry, Kevin I. , Taunton, Michael J. , Bedard, Nicholas A. , Lewallen, David G. , Abdel, Matthew P. , Berdis, Galen E , Carstens, Mason F. , Abdel, Matthew P , Larson, Dirk , Taunton, Michael J , Bedard, Nicholas A

Journal of Bone and Joint Surgery | July 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.2106/jbjs.26.00065 Get It

We previously reported 5-year results of 57 patients with major acetabular defects (Paprosky 2B through 3B) who underwent full (31) or half (26) cup-cage reconstructions. This study provides an update with 8.8-year mean follow-up. The 10-year cumulative incidence of and survivorship free from revision, reoperation, and complications were estimated. The 10-year cumulative incidence of revision was 14% for full and 12% for half constructs. The incidence of revision for aseptic loosening was 4.3% and 4.6%, respectively. The 10-year survivorship free from aseptic loosening for patients with pelvic discontinuity was 88.9% (95% confidence interval [CI], 70.6% to 100%) and 85.7% (95% CI, 61.8% to 100%), respectively; no patient without pelvic discontinuity required revision for aseptic loosening. The 10-year cumulative incidence of complications was 42% for all patients, including a 15% incidence of dislocation. Thus, both full and half cup-cage constructs provided durable fixation for complex acetabular bone loss at 10 years, although dislocation remains a concern. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Surprisingly Low Rates of Aseptic Loosening in 575 Rotating-Hinge Total Knee Arthroplasties
Terhune, E. Bailey , Carstens, Mason F. , Fruth, Kristin M. , Hannon, Charles P. , Bedard, Nicholas A. , Perry, Kevin I. , Berry, Daniel J. , Abdel, Matthew P. , Carstens, Mason , Abdel, Matthew P , Berry, Daniel J , Bedard, Nicholas A , Hannon, Charles P , Fruth, Kristin M

Journal of Bone and Joint Surgery | April 10, 2026 | Volume: 108 | Issue: 16 | Pages: 1289-1296

10.2106/jbjs.25.00837 Get It

Background: Contemporary rotating-hinge total knee arthroplasties (RH-TKAs) have shown reasonable short-term survivorship in smaller series, but concerns remain regarding risks of aseptic and septic failure. The purpose of this study was to assess outcomes of contemporary RH-TKAs in one of the largest series to date. Methods: We retrospectively identified 575 RH-TKAs (60% used for aseptic etiologies and 40% used during reimplantation in 2-stage treatment of periprosthetic joint infection [PJI]) from 2002 to 2021 at a single institution. The mean age was 67 years, 58% were female, and the mean body mass index was 33 kg/m 2 . Sixty-five percent had Anderson Orthopaedic Research Institute (AORI) type-2B or 3 bone loss. Kaplan-Meier survivorship analyses were performed. The mean follow-up was 6 years (range, 2 to 19 years). Results: Survivorship free from any revision was 76% at 5 years and 64% at 10 years. The most common revision indications were PJI (54%) and aseptic loosening (20%). RH-TKA used in the primary setting showed better survivorship compared with RH-TKA used during reimplantation after PJI (79% versus 60% at 10 years). Survivorship free from revision for aseptic loosening was 96% at 5 years and 90% at 10 years. Survivorship free from revision for PJI was 84% at 5 years and 81% at 10 years. Survivorship free from revision for PJI was even lower for RH-TKAs used during reimplantation, 74% at 5 years and 73% at 10 years. RH-TKA used during reimplantation in the treatment of PJI was associated with an increased risk of any revision (HR = 2, p < 0.001). Radiographic analysis of 425 knees that were not revised and had radiographs available for review showed that 6% of femoral components and 8% of tibial components had evidence of loosening at the time of final follow-up. The mean Knee Society Score improved from 33 to 69 at 2 years (p < 0.001). Conclusions: The 10-year survivorship free from aseptic loosening was 90% in this large series of RH-TKAs. This represents one of the best survivorships free from aseptic loosening published to date. Knees with prior PJI had markedly poorer survivorship than knees treated for aseptic etiologies, with double the risk of revision. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
How Often Does Bacteremia Occur in Patients With Chronic Periprosthetic Joint Infection? A Prospective, Observational Study
Ji, Baochao , Perry, Kevin I. , Li, Guoqing , Zhang, Xiaogang , Zhang, Guoqiang , Xu, Boyong , Li, Yicheng , Cao, Li, Zhang, Xiaogang, Cao, Li

Clinical Orthopaedics & Related Research | January 22, 2025 | Volume: 483 | Issue: 7 | Pages: 1206-1214

10.1097/corr.0000000000003367 Get It

Background Bacteremia is sometimes observed in patients with prosthetic joint infection (PJI), and it is associated with a lower likelihood of infection control. However, the prevalence and association of bacteremia in chronic PJI remain unknown. Questions/purposes (1) What percentage of patients are diagnosed with bacteremia at the time of hospital admission and before surgery for chronic PJI? (2) What clinical factors are associated with positive blood cultures? (3) To what degree are positive blood cultures associated with infection-free implant survival in patients with chronic PJI? Methods This prospective study was conducted at a single academic institution from June 2021 to August 2022. Within the study period, we treated 124 patients for chronic PJI, defined according to the modified Musculoskeletal Infection Society (MSIS) criteria. Of those, we considered patients who underwent revision surgery because of chronic PJI of the hip or knee as potentially eligible. All patients received two blood cultures within 48 hours after admission but before surgery. The second blood culture was performed on the contralateral arm 1 hour after the first was completed. Based on that, 87% (108 of 124) of patients were eligible; 13% (16 of 124) were excluded because of delayed blood sample transfers in 6% (7 of 124) of patients, contaminated samples in 2% (2 of 124), late hematogenous infection in 2% (3 of 124), and antibiotic use within 2 weeks before sampling in 3% (4 of 124). No patients were lost before the minimum study follow-up of 2 years without having reached a study endpoint (reinfection or persistent PJI) or had incomplete datasets, leaving 74% (92 of 124) for analysis here. The median (range) time from the index surgery (previous primary, debridement, or revision procedure) to the current revision for PJI in these patients was 16 months (2 to 180). Of the included patients, 40% (37 of 92) were men, 39% (36 of 92) had PJI of the hip, and 61% (56 of 92) had PJI of the knee. The mean age of patients was 65 ± 13 years, and the mean BMI was 28 ± 3 kg/m2. The interval between two cultures was at least 1 hour, and one culture was taken from each of the patient’s arms. Patients were divided into blood culture–positive and blood culture–negative groups based on preoperative blood culture results. The chi-square test and the independent t-test were used to compare demographic characteristics (gender, age, BMI, and affected joint) and clinical factors (American Society of Anesthesiologists [ASA] classification, hematological tests, comorbidities) between the two groups. Further multivariable logistic regression analysis was performed to assess the factors associated with positive blood cultures, which controlled for potential confounders including age, gender, BMI, and affected joint. The Firth penalized likelihood was employed when there was monotone likelihood in logistic regression analysis to reduce small-sample bias. A Kaplan-Meier curve tracked infection-free implant survival over 30 months, with differences evaluated using the log-rank test. Results Overall, 15% (14 of 92) of patients had positive blood cultures. After adjusting for age, gender, infection site, BMI, and intraoperative isolation of gram-positive cocci, we found that patients classified as ASA III (OR 4 [95% confidence interval (CI) 1 to 21]; p = 0.04) and those who had diabetes (OR 14 [95% CI 3 to 100]; p < 0.001) had a higher odds of positive blood cultures. We found no difference in the Kaplan-Meier estimate for infection-free implant survival at 30 months between those with positive blood cultures (86% [95% CI 76% to 95%]) and those with negative blood cultures (91% [95% CI 88% to 94%]; p = 0.51). Conclusion In this prospective, observational study, we found that chronic PJI can potentially lead to hematogenous dissemination of pathogens, particularly in patients with poor overall health (such as those classified as ASA III and patients diagnosed with diabetes). Therefore, selective preoperative blood cultures may be crucial in helping clinicians implement early intervention measures to prevent the serious consequences of bacteremia in patients with poor baseline health and those with other implanted devices. Larger studies with longer follow-up are needed to further validate these findings, ensure more robust estimates, and conduct comprehensive evaluations of the risk factors associated with positive blood cultures in chronic PJI. Level of Evidence Level II, therapeutic study.
Prospective Noninvasive Hemoglobin Monitoring in the Outpatient Total Joint Arthroplasty Setting
Dugdale, Evan M. , Mallinger, Benjamin D, Bedard, Nicholas A. , Couch, Cory , Mabry, Tad M. , Perry, Kevin I. , Sierra, Rafael J. , Taunton, Michael J. , Trousdale, Robert T. , Abdel, Matthew P. , Couch, Cory C , Abdel, Matthew P , Sierra, Rafael J , Taunton, Michael J , Bedard, Nicholas A , Mallinger, Benjamin D , Perry, Kevin I.

Journal of Bone and Joint Surgery | December 20, 2024 | Volume: 107 | Issue: 4 | Pages: 364-371

10.2106/jbjs.24.00438 Get It

Background: Total joint arthroplasty (TJA) is increasingly being performed as an outpatient (i.e., same-day discharge) procedure. Postoperatively, orthostatic hypotension or pain-related tachycardia can lead to concerns regarding the hemoglobin (Hgb) level of the patient prior to discharge. The purpose of this study was to prospectively assess the reliability and accuracy of, and patient and nurse satisfaction with, postoperative noninvasive hemoglobin (nHgb) monitoring compared with an invasive serum hemoglobin (iHgb) laboratory draw in the outpatient TJA setting. Methods: We prospectively enrolled 200 patients undergoing outpatient unilateral TJA, of whom 157 were ultimately included in our analysis (94 hips, 63 knees). Postoperatively, both nHgb and iHgb values were obtained at a mean of 36 minutes apart. Surveys were completed by patients and nurses. The strength of the agreement between the 2 Hgb monitoring methods was evaluated with use of the Bland-Altman 95% limits of agreement, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Receiver operating characteristic curve analyses were performed to investigate the ability of nHgb monitoring to predict an iHgb of <11.2 g/dL (the 5th-percentile iHgb value). Results: The mean preoperative iHgb was 14.2 ± 1.1 g/dL. The mean postoperative iHgb and nHgb values were 13.3 ± 1.5 and 13.3 ± 1.2 g/dL, respectively. The Bland-Altman 95% limits of agreement were −3.2 and +3.1 g/dL, indicating that 95% of patients’ iHgb values are expected to fall between these limits relative to the nHgb value of the patient. The CCC and ICC were both 0.33. An nHgb cutoff value of <12.7 g/dL had 100% sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Patients reported less pain with the nHgb test than with the iHgb test (mean pain score, 0.0 versus 1.8; p < 0.001), and 97% of patients preferred the nHgb test. Following the nHgb test, 73% of responding patients and 83% of responding nurses were “somewhat more reassured” to “significantly more reassured” about same-day discharge. Conclusions: Routine nHgb testing can rapidly screen patients undergoing outpatient TJA for acute anemia prior to discharge. With an nHgb of <12.7 g/dL, there was perfect sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Most patients and nurses felt more reassured about same-day discharge after nHgb monitoring. Level of Evidence: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.
3D-Printed Metaphyseal Cones in Revision Total Knee Arthroplasties
Carender, Christopher N. , Bothun, Cole E. , Taunton, Michael J. , Perry, Kevin I. , Bedard, Nicholas A. , Pagnano, Mark W. , Abdel, Matthew P. , Abdel, Matthew P , Taunton, Michael J , Bedard, Nicholas A

Journal of Bone and Joint Surgery | June 14, 2024 | Volume: 106 | Issue: 18 | Pages: 1688-1696

10.2106/jbjs.23.01196 Get It

Background: Porous metaphyseal cones are frequently utilized during revision total knee arthroplasty (TKA) procedures. The purpose of the present study was to evaluate 3D-printed metaphyseal cones used for revision TKA, with specific emphasis on implant survivorship, radiographic appearance, and clinical outcomes after short-term follow-up. Methods: We identified 740 cones (498 tibial, 242 femoral) that had been inserted during 533 revision TKA procedures that had been performed at a single tertiary care academic institution. Aseptic loosening (n = 199), periprosthetic joint infection (PJI) (n = 183), and instability (n = 84) were the most common reasons for the index revision. Type-2B or 3 bone loss was present in 67% of the knees. The mean age was 66 years, the mean body mass index was 34 kg/m 2 , and 55% of the patients were female. Serial radiographs were reviewed. The mean duration of follow-up was 4 years. Results: The 5-year cumulative incidence of cone revision for aseptic loosening was 1% (95% confidence interval [CI], 0% to 3%). The 5-year cumulative incidence of any cone revision or removal was 6% (95% CI, 4% to 9%). In total, 37 cones (19 femoral, 18 tibial) were revised, with PJI (n = 23; 14 recurrent), periprosthetic femoral fracture (n = 3), arthrofibrosis (n = 3), and aseptic loosening of the femoral component and femoral cone (n = 3) as the most common reasons for cone revision. The 5-year cumulative incidence of any TKA re-revision was 14% (95% CI, 11% to 18%). There were a total of 67 re-revisions, with PJI (n = 38), persistent drainage (n = 6), and extensor mechanism disruption (n = 3) being the most common reasons. Radiographically, 2 unrevised femoral cones and 1 unrevised tibial cone appeared to be possibly loose; all 3 cones were in knees with distal femoral replacements or hinged constructs. Conclusions: This large series showed that 3D-printed titanium metaphyseal cones were very durable at short-term follow-up, with a 5-year cumulative incidence of cone revision for aseptic loosening of 1%. PJI was the most common reason for cone revision and any revision. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Modular fluted tapered stems in two-stage reimplantation of previously infected total hip arthroplasties
Carender, Christopher N. , Perry, Kevin I. , Trousdale, Robert T. , Berry, Daniel J. , Berry, Daniel J , Sierra, Rafael J. , Abdel, Matthew P.

The Bone & Joint Journal | May 1, 2024 | Volume: 106-B | Issue: 5 Supple B | Pages: 125-132

10.1302/0301-620x.106b5.bjj-2023-0788.r2 Get It

AimsUncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants – modular fluted tapered (MFT) femoral components – in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components.MethodsWe identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used.ResultsThe 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n = 25) and infection (n = 16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only two FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence ≥ 5 mm occurred in 2% of unrevised cases. All stems were radiologically stable at most recent follow-up. Mean Harris Hip Score was 69 (SD 20) at most recent follow-up.ConclusionThis series demonstrated that MFT components were durable and reliable in the setting of two-stage reimplantation THA for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily due to dislocation and recurrent PJI.Cite this article: Bone Joint J 2024;106-B(5 Supple B):125–132.
Marlex Mesh Reconstruction of the Extensor Mechanism
Abdel, Matthew P. , Carender, Christopher N. , Bedard, Nicholas A. , Perry, Kevin I. , Pagnano, Mark W., Hanssen, Arlen D. , Abdel, Matthew P , Bedard, Nicholas A , Pagnano, Mark W.

Journal of Bone and Joint Surgery | January 9, 2024 | Volume: 106 | Issue: 7 | Pages: 608-616

10.2106/jbjs.23.01006 Get It

Marlex mesh reconstruction of the extensor mechanism following total knee arthroplasty (TKA) has demonstrated excellent early results. The purpose of the present study was to evaluate longer-term results of Marlex mesh reconstruction of the extensor mechanism in 93 TKAs. Seventy-seven reconstructions were aseptic, and 16 were performed as part of a 2-stage exchange for the treatment of infection. Mean follow-up was 8 years. Twenty-eighty patients experienced mesh failure. Seventeen failures were treated with mesh revision (8 for patellar tendon rupture, 7 for quadriceps tendon rupture, and 2 for symptomatic lengthening). The 10-year cumulative incidence of mesh revision for mesh failure was 20%. Extensor lag improved by a mean of 28°, with a mean extensor lag of 9° at most recent follow-up. At a mean follow-up of 8 years, Marlex mesh reconstruction was a durable and reliable technique to treat both aseptic and septic ruptures of the extensor mechanism. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Extended Trochanteric Osteotomy in Revision Total Hip Arthroplasty
Wyles, Cody C. , Hannon, Charles P. , Viste, Anthony , Perry, Kevin I. , Trousdale, Robert T. , Berry, Daniel J. , Abdel, Matthew P. , Abdel, Matthew P , Wyles, Cody C , Berry, Daniel J , Hannon, Charles P

JBJS Essential Surgical Techniques | August 10, 2023 | Volume: 13 | Issue: 3 | Pages: No page available

10.2106/jbjs.st.21.00003 Get It

Background: Removal of well-fixed femoral components during revision total hip arthroplasty (THA) can be difficult and time-consuming 1 , leading to numerous complications, such as femoral perforation, bone loss, and fracture. Extended trochanteric osteotomies (ETOs), which provide wide exposure and direct access to the femoral canal under controlled conditions, have become a popular method to circumvent these challenges. ETOs were popularized by Wagner (i.e., the anterior-based osteotomy), and later modified by Paprosky (i.e., the lateral-based osteotomy) 2 . Description: The decision to utilize the laterally based Paprosky ETO versus the anteriorly based Wagner ETO is primarily based on surgeon preference, the location and type of in situ implants, and the osseous anatomy. Typically, a laterally based ETO is most facile in conjunction with a posterior approach and an anteriorly based ETO is most commonly paired with a lateral or anterolateral approach. Attention must be paid to maintaining vascularity to the osteotomy fragment, including minimizing stripping of the vastus lateralis from the osteotomy fragment and maintaining abductor attachments to the osteotomy fragment. When utilizing a laterally based ETO, the posterior border of the vastus lateralis must be carefully elevated to provide exposure for performance of the osteotomy. When an anteriorly based osteotomy is performed, the surgeon may instead extend the abductor tenotomy proximally with use of a longitudinal split of the vastus lateralis distally, which helps to keep the anterior and posterior sleeves of soft tissue in continuity. In either approach, dissection of the vastus lateralis involves managing several large vascular perforators. We prefer performing careful blunt dissection to identify the perforators and prophylactically controlling them, with ligation of large vessels and electrocautery of smaller vessels. Vascular clips are also available in case difficult-to-control bleeding is encountered. In general, an oscillating saw (with preference for a thin blade) is utilized to complete the posterior longitudinal limb of the ETO, extending approximately 12 to 16 cm distally from the tip of the greater trochanter. Although a 12 to 16-cm zone is required to maintain maximum vascularity to the osteotomized fragment, the osteotomy length must ultimately be determined by (1) the length of the femoral component to be removed; (2) the presence of distal bone ingrowth, ongrowth, or cement; and (3) the presence of distal hardware or stemmed knee components. A smaller oscillating saw is then utilized to complete the transverse limb at the previously identified distal extent. A high-speed pencil-tip burr is utilized to complete the corners of the osteotomy in a rounded configuration, and a combination of saws and pencil-tip burrs is utilized to create partial proximal and distal anterior longitudinal limbs of the osteotomy to the extent allowed by the soft-tissue attachments. The anterior longitudinal limb may be further weakened in a controlled fashion with use of serial drill holes. The anterior longitudinal limb then undergoes controlled fracture by placement of 2 to 4 broad straight osteotomes in the posterior longitudinal limb. These osteotomes are carefully levered anteriorly in unison with a gentle, steady force. After the ETO is completed, intramedullary prostheses, hardware, and cement are removed; the acetabulum is addressed as needed; and a final femoral stem is implanted, if appropriate. After completion of the osteotomy, the osteotomized fragment must be retracted gently, with care taken to avoid a fracture and maintain vascularity. To this end, debridement of the endosteum of the osteotomized fragment, including any cement removal, should be avoided until the end of the procedure, when the osteotomy is ready to be closed. Our preferred method for closure is to place 1 prophylactic cable 1 cm distal to the osteotomy, 1 to 2 cables along the diaphyseal segment of the osteotomy, and 1 Luque wire above the less trochanter. A Luque wire is our specific choice for the location above the lesser trochanter because it sits in the effective joint space; however, the use of Luque wires distal to the lesser trochanter is also acceptable. A strut allograft or locking plate can be utilized to reinforce the osteotomy in rare cases or to bridge interprosthetic stress risers. Trochanteric implants are typically avoided because of the low rate of clinically relevant trochanteric migration with this closure technique and because of the high rate of symptomatic implants with trochanteric claws or plates. Alternatives: An alternative osteotomy of similar exposure is the transfemoral osteotomy. Additionally, a variety of non-extended trochanteric osteotomies, such as trochanteric slide osteotomies, offer more limited exposure. Rationale: Femoral surgical exposure for revision THA can be aided by performing transfemoral osteotomies, but these provide less precise control of the separate proximal femoral osteotomized segment(s), and healing and fixation can be less reliable. Less invasive osteotomies such as non-extended trochanteric osteotomies typically do not provide adequate exposure in challenging cases for which ETO is being considered. Expected Outcomes: ETOs have high union rates, and notable trochanteric migration is infrequent. The most common complications are fracture of the osteotomy fragment intraoperatively or postoperatively. Radiographic and clinical union is achieved in 98% of patients. The mean proximal trochanteric osteotomy fragment migration prior to union is 3 mm. ETO fragment migration of >1 cm occurs in just 7% of hips. Postoperative greater trochanter fractures occur in 9% of hips. The 10-year survivorship free of revision for aseptic femoral loosening, free of femoral or acetabular component removal or revision for any reason, and free of reoperation for any reason is 97%, 91%, and 82%, respectively 3 . Important Tips: Attention should be paid to patient anatomy, deformity, surgical approach, and implant type when choosing to perform a laterally based Paprosky or anteriorly based Wagner ETO. Appropriate length of the posterior longitudinal limb of the ETO is approximately 12 to 16 cm distally from the tip of the greater trochanter. Attention must be paid to maintaining vascularity to the osteotomy fragment, including minimizing stripping of the vastus lateralis from the osteotomy fragment and maintaining abductor attachments to the osteotomy fragment. A high-speed pencil-tip burr should be utilized to complete the corners of the osteotomy in a rounded configuration in order to avoid stress risers. The anterior longitudinal limb is completed by controlled fracture of the remaining intervening segment in order to maintain vastus lateralis attachments and vascular supply to the osteotomy fragment. The ETO is closed with use of cerclage cables and/or double-stranded Luque wires, typically utilizing a total of 3 to 4 in order to obtain secure fixation without compromising local biology. Acronyms and Abbreviations: MFT = modular fluted tapered
Contemporary outcomes of primary total hip arthroplasty in patients with inflammatory arthritis
Wooster, Benjamin M., Kennedy, Nicholas I. , Dugdale, Evan M. , Sierra, Rafael J. , Perry, Kevin I. , Berry, Daniel J. , Abdel, Matthew P. , Abdel, Matthew P , Sierra, Rafael J , Berry, Daniel J

The Bone & Joint Journal | July 1, 2023 | Volume: 105-B | Issue: 7 | Pages: 768-774

10.1302/0301-620x.105b7.bjj-2023-0220.r1 Get It

AimsContemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the implant survivorship, complications, radiological results, and clinical outcomes of THA in patients with inflammatory arthritis.MethodsWe identified 418 hips (350 patients) with a primary diagnosis of inflammatory arthritis who underwent primary THA with HXLPE liners from January 2000 to December 2017. Of these hips, 68% had rheumatoid arthritis (n = 286), 13% ankylosing spondylitis (n = 53), 7% juvenile rheumatoid arthritis (n = 29), 6% psoriatic arthritis (n = 24), 5% systemic lupus erythematosus (n = 23), and 1% scleroderma (n = 3). Mean age was 58 years (SD 14.8), 66.3% were female (n = 277), and mean BMI was 29 kg/m2 (SD 7). Uncemented femoral components were used in 77% of cases (n = 320). Uncemented acetabular components were used in all patients. Competing risk analysis was used accounting for death. Mean follow-up was 4.5 years (2 to 18).ResultsThe ten-year cumulative incidence of any revision was 3%, and was highest in psoriatic arthritis patients (16%). The most common indications for the 15 revisions were dislocations (n = 8) and periprosthetic joint infections (PJI; n = 4, all on disease-modifying antirheumatic drugs (DMARDs)). The ten-year cumulative incidence of reoperation was 6.1%, with the most common indications being wound infections (six cases, four on DMARDs) and postoperative periprosthetic femur fractures (two cases, both uncemented femoral components). The ten-year cumulative incidence of complications not requiring reoperation was 13.1%, with the most common being intraoperative periprosthetic femur fracture (15 cases, 14 uncemented femoral components; p = 0.13). Radiological evidence of early femoral component subsidence was observed in six cases (all uncemented). Only one femoral component ultimately developed aseptic loosening. Harris Hip Scores substantially improved (p < 0.001).ConclusionContemporary primary THAs with HXLPE in patients with inflammatory arthritis had excellent survivorship and good functional outcomes regardless of fixation method. Dislocation, PJI, and periprosthetic fracture were the most common complications in this cohort with inflammatory arthritis.Cite this article: Bone Joint J 2023;105-B(7):768–774.