Background: Infection following extensor mechanism reconstruction (EMR) with Marlex mesh (C.R. Bard) is devastating and limb-threatening. The purpose of this study was to evaluate whether vancomycin-loaded mesh reduces staphylococcal infection in a murine EMR model. Methods: Mouse-sized, 8-layer mesh constructs were fabricated to simulate clinical reconstruction and soaked in a vancomycin solution (50 mg/mL) for in vitro and in vivo testing. Three methicillin-resistant clinical isolates from human periprosthetic Staphylococcus aureus, Staphylococcus epidermidis, and Staphylococcus lugdunensis knee infections were evaluated. In vitro testing assessed vancomycin loading capacity, mechanical properties, antibacterial activity, and inhibition of biofilm formation. For in vivo experiments, plain or vancomycin-loaded mesh was implanted into C57BL/6 mouse extensor mechanisms, which were intraoperatively contaminated with 1 of the 3 study isolates (5 per group). Mesh and surrounding tissue were harvested for quantitative culture on postoperative day 9. Results: For all 3 isolates, vancomycin-loaded mesh produced zones of inhibition and exhibited antibacterial activity through at least 3 days in vitro (p < 0.0001). Mechanical testing revealed that loading mesh with vancomycin did not negatively impact tensile strength, hysteresis, or suture pull-through properties. In vitro testing of inhibition of biofilm formation demonstrated reduced colony-forming units 6 hours after inoculation, which remained low throughout the 9-day experimental period (p < 0.05 for all isolates). In vivo, vancomycin-loaded mesh reduced bacterial burden on mesh and in surrounding tissue by >3 log 10 compared with plain mesh for all 3 isolates (p < 0.01 for both mesh and tissue). Conclusions: Vancomycin-loaded mesh provided in vitro antibacterial activity without compromising mesh mechanical properties and reduced staphylococcal infection in a murine EMR model. Further work is needed to evaluate translational potential and safety before clinical application. Clinical Relevance: Mesh-associated infection after EMR is devastating and difficult to treat. These preclinical findings suggest that local vancomycin delivery may serve as an adjunct to systemic prophylaxis, warranting further study before clinical use.
Five-year survival and complications of more than 300 articulating high-dose antibiotic spacers in two-stage revision total hip arthroplasties for infection
Aims Two-stage exchange arthroplasty with an antibiotic-eluting cement spacer remains the predominant strategy in the USA for managing chronic periprosthetic joint infection (PJI) following total hip arthroplasty (THA). The aim of this study was to evaluate a commercially available, partially intraoperatively fabricated articulating high-dose antibiotic cement spacer, focusing on survival, complications, and patient-reported outcomes. Methods A total of 298 patients (302 THAs) underwent two-stage exchange arthroplasty for PJI using a specific articulating antibiotic spacer between August 2005 and May 2022. Patients with a previous failed two-stage exchange were excluded, although 121 THAs (302, 40%) had undergone previous PJI-related procedures. The mean age of the patients was 65 years (SD 11), the mean BMI was 32 kg/m 2 (SD 7), and 116 (38%) were female. Most patients were classified as McPherson host B (158; 52%) and limb grade 2 (165; 55%), and 265 (88%) met the 2011 Musculoskeletal Infection Society criteria. The mean follow-up was six years (2 to 16). Results At five years after reimplantation, survival free of reinfection, aseptic rerevision, any rerevision, or any reoperation were 89% (95% CI 85.2 to 93.1), 93% (95% CI 89.3 to 96.1), 86% (95% CI 81.3 to 90.3), and 80% (95% CI 74.7 to 84.9), respectively. Dislocation accounted for most aseptic rerevisions (15/20). McPherson host C (HR 3.7 (95% CI 1.4 to 9.6); p = 0.007) and limb grade 3 (HR 3.3 (95% CI 1.0 to 11.1); p = 0.049) were significantly associated with an increased risk of reinfection. The mean Harris Hip Score at the latest follow-up was 76 (29 to 100). A total of 17 patients underwent revision or removal of a spacer for concerns about persistent infection and two for dislocation of the spacer. Eight patients underwent a non-rerevision reoperation during the spacer interval for wound drainage (n = 5), dislocation of the spacer (n = 2), and perispacer fracture (n = 1). A total of 26 spacer-related complications were treated nonoperatively (15 perispacer fractures, 11 dislocations). Dislocation of the spacer was strongly associated with dislocation after reimplantation (HR 6.2 (95% CI 2.3 to 16.9); p < 0.001). Conclusion This commercially available, partially intraoperatively fabricated articulating spacer showed excellent reinfection-free five-year survival (89%). Spacer-related fracture and dislocation each occurred in 5% of patients. Dislocation of the spacer significantly increased the risk of dislocation following reimplantation, supporting the use of higher-stability bearings in these high-risk patients. Cite this article: Bone Joint J 2026;108-B(9):1104–1112.
In vitro evaluation of vancomycin-loaded Marlex mesh against staphylococci isolated from periprosthetic joint infection
Aims Extensor mechanism disruption is a major complication following total knee arthroplasty, with treatment often consisting of extensor mechanism reconstruction utilizing monofilament polypropylene mesh (Marlex mesh, C. R. Bard, Inc). Infection following this procedure is devastating, often resulting in revision surgery and mesh removal, with permanent limb dysfunction. This study evaluated the in vitro ability of vancomycin-loaded polypropylene mesh to inhibit growth of isolates of three Staphylococcus species from patients with periprosthetic joint infection. Methods The mesh was prepared in two configurations – single-layer and eight-layer – and soaked for ten minutes in either sterile water (control) or vancomycin solution (50 mg/ml), after which the mesh was placed on tryptic soy agar plates inoculated with staphylococci and incubated at 37°C for 18 to 24 hours. Zones of inhibition were measured daily over seven days, with mesh transferred to freshly inoculated plates daily. Testing was performed in triplicate, with experiments repeated three times for each bacterial isolate. A total of 30 clinical isolates were tested (five methicillin-susceptible Staphylococcus epidermidis , five methicillin-resistant S. epidermidis , ten methicillin-resistant Staphylococcus aureus , and ten Staphylococcus lugdunensis ). Results Across all species, the eight-layer vancomycin-loaded mesh produced statistically significantly larger median zones of inhibition than the single-layer mesh. The antibacterial activity of the eight-layer mesh persisted through to day 7, while the single-layer mesh showed reduced activity by days 4 to 5. Conclusion Compared with single-layer vancomycin-loaded mesh, multilayer vancomycin-loaded mesh, which mimics clinical application, provides enhanced and sustained antibacterial activity in vitro. Cite this article: Bone Joint Res 2026;15(8):998–1004.
Full and Half Cup-Cage Reconstruction of Major Acetabular Defects
We previously reported 5-year results of 57 patients with major acetabular defects (Paprosky 2B through 3B) who underwent full (31) or half (26) cup-cage reconstructions. This study provides an update with 8.8-year mean follow-up. The 10-year cumulative incidence of and survivorship free from revision, reoperation, and complications were estimated. The 10-year cumulative incidence of revision was 14% for full and 12% for half constructs. The incidence of revision for aseptic loosening was 4.3% and 4.6%, respectively. The 10-year survivorship free from aseptic loosening for patients with pelvic discontinuity was 88.9% (95% confidence interval [CI], 70.6% to 100%) and 85.7% (95% CI, 61.8% to 100%), respectively; no patient without pelvic discontinuity required revision for aseptic loosening. The 10-year cumulative incidence of complications was 42% for all patients, including a 15% incidence of dislocation. Thus, both full and half cup-cage constructs provided durable fixation for complex acetabular bone loss at 10 years, although dislocation remains a concern. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Lessons Learned from Nonoperative Management of Greater Trochanter Fractures After Total Hip Arthroplasty
Background: Greater trochanteric (GT) fractures after total hip arthroplasty (THA) are typically managed nonoperatively. However, outcome data for patient counseling remain limited. We evaluated the nonoperative results, focusing on fracture union rates and the presence of persistent limp in relation with fracture location, displacement magnitude, and direction. Methods: We retrospectively reviewed 82 postoperative GT fractures not associated with trochanteric osteolysis following primary THA performed between 1984 and 2020. The mean follow-up was 9 years. Fracture location was classified relative to the contralateral lesser trochanter as tip, waist, or base. Initial displacement, migration, final displacement, and bony union were assessed radiographically. Clinical outcomes included the presence of a persistent limp and Harris Hip Score. Multivariable analyses were performed to identify factors associated with nonunion and limp. Results: Fractures were classified as tip (n = 32), waist (n = 29), or base (n = 21). The mean initial displacement was 8.9 mm, with 43% displaced >10 mm. Initial displacement was significantly lower in base fractures (4.8 mm) compared with tip (10.1 mm) or waist (10.8 mm) fractures (p < 0.05). The mean final displacement was 14.6 mm. 45% of fractures achieved complete bony union, and 38% of patients demonstrated a persistent limp. In multivariable analysis, greater final displacement (>12 mm), and tip and waist fractures were independently associated with nonunion. Posterior fracture displacement was significantly associated with persistent limp. Conclusions: Outcomes following nonoperative management of GT fractures after THA depend on fracture morphology and displacement characteristics. Tip and waist fractures and fractures with final displacement >12 mm have a higher risk of nonunion, whereas posterior and superior displacement is associated with persistent limp. Greater than 20 mm of displacement is associated with both limp and nonunion. These findings may assist surgeons in counseling patients and in identifying fracture patterns at higher risk for adverse outcomes of nonoperative management. Level of Evidence: Level III (Prognostic Study). See Instructions for Authors for a complete description of levels of evidence.
Design and validation of a biomechanics device for preclinical arthrofibrosis models
Aims Reliable assessment of joint stiffness is essential for studying arthrofibrosis in preclinical animal models. This study presents a new dedicated biomechanics device for measuring knee stiffness in mouse, rat, and rabbit models of arthrofibrosis, with the aim of validating its performance and comparing it to a previously validated device. Methods The new system integrates a torque load cell, stepper motor, and absolute encoder in a through-hole, unified configuration for precise continuous torque-angle measurement, with custom limb brackets ensuring species-specific alignment at the joint’s centre of rotation. To validate this device and compare it to a previously validated device, arthrofibrosis was induced using established models of extra-articular immobilization in mice and intra-articular violation with immobilization in rats and rabbits, followed by defined remobilization periods. Torque-angle curves were recorded ex vivo across species-specific torque ranges, and measurement variability between the new and a previous validated device was statistically compared using Brown-Forsythe’s test. Results The onset of hyperextension in contralateral limbs occurred at mean angles of 152.4° (mice), 154.4° (rats), and 152.8° (rabbits), and at maximum torque, mean flexion angles were 79.2°, 87.3°, and 140.5°, respectively. No significant differences in measurement variability were observed between devices across all species. Conclusion These findings demonstrate that our new device provides reproducible torque-angle data while maintaining the statistical robustness of the previous device and offering improved mechanical design and operational standardization. By enabling standardized, cross-species joint stiffness quantification, this platform improves cross-study comparability and strengthens the translational reliability of preclinical arthrofibrosis research. Cite this article: Bone Joint Res 2026;15(6):716–725.
Surprisingly Low Rates of Aseptic Loosening in 575 Rotating-Hinge Total Knee Arthroplasties
Background: Contemporary rotating-hinge total knee arthroplasties (RH-TKAs) have shown reasonable short-term survivorship in smaller series, but concerns remain regarding risks of aseptic and septic failure. The purpose of this study was to assess outcomes of contemporary RH-TKAs in one of the largest series to date. Methods: We retrospectively identified 575 RH-TKAs (60% used for aseptic etiologies and 40% used during reimplantation in 2-stage treatment of periprosthetic joint infection [PJI]) from 2002 to 2021 at a single institution. The mean age was 67 years, 58% were female, and the mean body mass index was 33 kg/m 2 . Sixty-five percent had Anderson Orthopaedic Research Institute (AORI) type-2B or 3 bone loss. Kaplan-Meier survivorship analyses were performed. The mean follow-up was 6 years (range, 2 to 19 years). Results: Survivorship free from any revision was 76% at 5 years and 64% at 10 years. The most common revision indications were PJI (54%) and aseptic loosening (20%). RH-TKA used in the primary setting showed better survivorship compared with RH-TKA used during reimplantation after PJI (79% versus 60% at 10 years). Survivorship free from revision for aseptic loosening was 96% at 5 years and 90% at 10 years. Survivorship free from revision for PJI was 84% at 5 years and 81% at 10 years. Survivorship free from revision for PJI was even lower for RH-TKAs used during reimplantation, 74% at 5 years and 73% at 10 years. RH-TKA used during reimplantation in the treatment of PJI was associated with an increased risk of any revision (HR = 2, p < 0.001). Radiographic analysis of 425 knees that were not revised and had radiographs available for review showed that 6% of femoral components and 8% of tibial components had evidence of loosening at the time of final follow-up. The mean Knee Society Score improved from 33 to 69 at 2 years (p < 0.001). Conclusions: The 10-year survivorship free from aseptic loosening was 90% in this large series of RH-TKAs. This represents one of the best survivorships free from aseptic loosening published to date. Knees with prior PJI had markedly poorer survivorship than knees treated for aseptic etiologies, with double the risk of revision. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Primary total knee arthroplasty for primary and secondary osteonecrosis
Aims Total knee arthroplasty (TKA) for end-stage osteonecrosis has historically been associated with concerns regarding aseptic loosening, and long-term data are limited. The purpose of this study was to update and expand our previous series with long-term follow-up, with specific emphasis on implant survivorship, risk factors for failure, complications, and clinical outcomes in a consecutive cohort of TKAs performed for primary and secondary osteonecrosis. Methods We retrospectively identified 295 consecutive TKAs in 266 patients for osteonecrosis performed at a single tertiary care academic institution from January 2002 to July 2022. Of these, 207 TKAs (70%) were performed for primary osteonecrosis, and 88 (30%) for secondary osteonecrosis. The predominant cause of secondary osteonecrosis was steroid use (59%; n = 52), followed by post-traumatic (25%; n = 22), radiation-induced (9%; n = 8), and alcohol-induced (7%; n = 6) osteonecrosis. Implant survivorship was analyzed as a time-to-event outcome using Kaplan-Meier estimation. The mean age was 61 years (18 to 93), with 67% being female (n = 197). The mean follow-up was nine years (2 to 20). Results The 15-year survivorship free of any revision for the entire cohort was 92% (95% CI 87 to 97), with similar rates between primary and secondary osteonecrosis (92% (95% CI 87 to 98) vs 93% (95% CI 87 to 100), respectively; p = 0.459). Varus-valgus constraint implant designs (HR 10.8 (95% CI 2.7 to 43.4); p < 0.001) and tibial stem use (HR 12.0 (95% CI 4.1 to 35.1); p < 0.001) were associated with an increased risk of any revision. The 15-year survivorship free of aseptic loosening was 97% (95% CI 93 to 100) for the entire cohort. Age under 65 years (HR 2.7 (95% CI 1.4 to 5.4); p = 0.005) and secondary osteonecrosis (HR 1.9 (95% CI 1.0 to 3.4); p = 0.044) were associated with an increased risk of any reoperation at 15 years. Conclusion TKA is a durable and reliable option for primary osteonecrosis at long-term follow-up. However, TKAs performed for secondary osteonecrosis carry a higher reoperation risk. Cite this article: Bone Joint J 2026;108-B(4):455–462.
Extended Trochanteric Osteotomy Combined with Medial Reduction Corticotomy to Correct Femoral Deformity at the Time of Revision Total Hip Arthroplasty
Background: An extended trochanteric osteotomy (ETO) is commonly used to improve exposure and facilitate femoral component removal in revision total hip arthroplasty (THA). An additional medial corticotomy may be used in conjunction with an ETO to correct a femoral deformity, particularly varus remodeling in association with a failed femoral component. This study evaluated the outcomes of combining an ETO with a medial corticotomy in revision THA, with emphasis on implant fixation, femoral alignment, bone union, and clinical outcomes. Methods: Of the 612 ETOs performed between 2003 and 2013, 13 patients (9 men and 4 women) underwent ETO combined with a medial corticotomy to correct varus remodeling, representing 2% of all ETOs during that period. The average follow-up was 8 ± 3.5 years. The mean age at surgery was 67 ± 13.5 years. The mean body mass index was 32 ± 7.7 kg/m 2 . Radiographs were reviewed to measure preoperative and postoperative femoral deformity, time to consolidation, and femoral fixation. Clinical outcomes were evaluated using the Harris Hip Score (HHS). Results: All patients had preoperative varus femoral deformity (mean 16.3° ± 5.7°). The mean postoperative alignment was 4.3 ± 1.6° varus achieving an average correction of 12° (95% CI −15.7 to −8.3, p < 0.0001). Both the ETO and the medial corticotomy consolidated in 10 of 11 patients (91%) with available 1-year radiographs at a mean of 11 ± 7.7 months. The mean HHS improved significantly from 42 preoperatively to 82 at 5-year follow-up (p = 0.0002). Complications related to the ETO and corticotomy occurred in 4 patients (30%), including 1 intraoperative fracture, 1 postoperative greater trochanteric fracture, 1 nonunion of the medial corticotomy, and 1 postoperative wound-hematoma. All femoral components remained well fixed at final follow-up. Conclusion: The combination of ETO and medial corticotomy in revision THA effectively corrected femoral alignment in patients with a preoperative varus deformity and was associated with significant functional improvement at the final follow-up. Level of Evidence: Level IV . See Instructions for Authors for a complete description of levels of evidence.
Mean Body Mass Index Does Not Increase or Decrease at 10 Years After Primary Total Hip or Knee Arthroplasty
Background: Although patients often aim to lose weight after total hip arthroplasty (THA) or total knee arthroplasty (TKA), long-term changes in body mass index (BMI) are unknown. We analyzed BMI at 2, 5, and 10 years after primary THA and TKA and determined predictors of BMI change. Methods: We identified patients who underwent primary THA or TKA for osteoarthritis between 2001 and 2011 and had a BMI at surgery and at 2, 5, and 10 years postoperatively. This resulted in 763 patients (310 who underwent THA and 453 who underwent TKA). The mean patient age was 66 years, and 60% of patients were female. BMI changes were analyzed with repeated-measures analysis of variance. Multinomial logistic regression determined predictors of BMI change. Results: Following THA, the mean BMI increased from 30.3 kg/m 2 at surgery to 30.9 kg/m 2 at both 2 years (p = 0.003) and 5 years (p = 0.002). Following TKA, the mean BMI increased from 32.7 kg/m 2 at surgery to 33.1 kg/m 2 at both 2 years (p = 0.053) and 5 years (p = 0.040). By 10 years, the mean BMI was 30.6 kg/m 2 (p = 0.453) for patients undergoing THA and 32.6 kg/m 2 (p = 0.947) for patients undergoing TKA, similar to the BMIs at surgery. At 10 years, 27% of patients who underwent THA and 30% of patients who underwent TKA had a BMI decrease of >5%, whereas 30% of patients who underwent THA and 32% of patients who underwent TKA had a BMI increase of >5%. Female sex among patients who underwent THA increased the odds of a >5% BMI increase at 10 years (odds ratio [OR], 2.1; p = 0.006). Older age among patients who underwent TKA decreased the odds of a >5% BMI increase at 10 years (OR per year, 0.95; p < 0.001). Conclusions: Although most patients experienced a BMI change of >5% at 10 years, the mean BMI did not meaningfully change 2, 5, or 10 years after THA or TKA. Arthroplasty should not be viewed as a gateway to BMI improvement for patients overall, but female sex and older age may predict clinically important weight changes 10 years after arthroplasty. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.