Back to Authors

Sanchez-Sotelo, J.

0000-0003-3199-3247

Mayo Clinic

Mayo Clinic

Citations 43

Refining Shoulder Diagnostics: A Technical Note on Scapular Physical Examination
Selman, Farah , Perry, Nicholas P.J. , Restrepo, Diego J. , Coleman, David, Sánchez‐Sotelo, Joaquín , Perry, Nicholas Peter James , Restrepo, Diego J. , Sanchez-Sotelo, J.

Arthroscopy Techniques | July 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/atn2.70203 Get It

Abstract Normal scapulothoracic function relies on a delicate balance among several periscapular muscles and is essential for shoulder motion. Disturbance in this balance can lead to abnormal motion, which can impair shoulder function, leading to pain and discomfort. A thorough scapular examination requires an accurate physical assessment and the ability to identify pathologies, such as muscle paralysis (e.g., trapezius or serratus anterior) and hyperactivity (e.g., pectoralis minor). Overall, a comprehensive approach to the physical examination is critical in accurately diagnosing and effectively treating shoulder and scapular pathologies. The purpose of this technical note is to provide a concise, standardized methodology for performing a comprehensive scapular examination, focusing on key clinical tests, anatomical landmarks, and motion patterns.
Design and validation of a biomechanics device for preclinical arthrofibrosis models
Carstens, Mason , Meißner, Nils , Weintraub, Matthew T. , Pichurin, Oksana , Morrey, Mark E. , Sánchez‐Sotelo, Joaquín , Thaler, Roman , Abdel, Matthew P. , Carstens, Mason F. , Thaler, Roman , Abdel, Matthew P , Meissner, Nils , Sanchez-Sotelo, J. , Morrey, Mark E , Berry, Daniel J.

Bone & Joint Research | June 19, 2026 | Volume: 15 | Issue: 6 | Pages: 716-725

10.1302/2046-3758.156.bjr-2025-0620.r1 Get It

Aims Reliable assessment of joint stiffness is essential for studying arthrofibrosis in preclinical animal models. This study presents a new dedicated biomechanics device for measuring knee stiffness in mouse, rat, and rabbit models of arthrofibrosis, with the aim of validating its performance and comparing it to a previously validated device. Methods The new system integrates a torque load cell, stepper motor, and absolute encoder in a through-hole, unified configuration for precise continuous torque-angle measurement, with custom limb brackets ensuring species-specific alignment at the joint’s centre of rotation. To validate this device and compare it to a previously validated device, arthrofibrosis was induced using established models of extra-articular immobilization in mice and intra-articular violation with immobilization in rats and rabbits, followed by defined remobilization periods. Torque-angle curves were recorded ex vivo across species-specific torque ranges, and measurement variability between the new and a previous validated device was statistically compared using Brown-Forsythe’s test. Results The onset of hyperextension in contralateral limbs occurred at mean angles of 152.4° (mice), 154.4° (rats), and 152.8° (rabbits), and at maximum torque, mean flexion angles were 79.2°, 87.3°, and 140.5°, respectively. No significant differences in measurement variability were observed between devices across all species. Conclusion These findings demonstrate that our new device provides reproducible torque-angle data while maintaining the statistical robustness of the previous device and offering improved mechanical design and operational standardization. By enabling standardized, cross-species joint stiffness quantification, this platform improves cross-study comparability and strengthens the translational reliability of preclinical arthrofibrosis research. Cite this article: Bone Joint Res 2026;15(6):716–725.
Informed Consent for Robotic-Assisted Reverse Shoulder Arthroplasty
Menendez, Mariano E. , Sánchez‐Sotelo, Joaquín , Sanchez-Sotelo, J. , Menendez, Mariano E.

Journal of Bone and Joint Surgery | May 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.2106/jbjs.26.00325 Get It

Lower Trapezius Transfer at the Time of Reverse Shoulder Arthroplasty with an Allograft-Prosthetic Composite Can Restore External Rotation
Sánchez‐Sotelo, Joaquín , Hart, Christopher M. , Weir, Tristan B. , Graden, Nathan , Gulzar, Musab , Elhassan, Bassem T. , Wagner, Eric, Elhassan, Bassem T. , Sanchez-Sotelo, J. , Weir, Tristan B. , Graden, Nathan R. , Wagner, Eric R.

Journal of Bone and Joint Surgery | May 21, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.2106/jbjs.25.01692 Get It

Background: The purpose of this study was to describe, and report the outcomes of, a surgical technique that combines reverse shoulder arthroplasty (RSA) using an allograft-prosthetic composite (APC) with a lower trapezius transfer (LTT) to the infraspinatus of the allograft extended with the inferior capsule. Methods: Between 2019 and 2023, 2 surgeons performed a total of 27 RSAs using an APC in conjunction with an LTT. Once the RSA APC reconstruction had been performed, cuff-capsule allograft tissue was passed posterior to the glenosphere and secured to the harvested lower trapezius. One shoulder was resected for periprosthetic joint infection; the remaining 26 shoulders were followed for a minimum of 2 years (mean, 2.7 years; range, 2 to 5 years). Results: The rate of revision or reoperation for humeral complications was 15% and included secondary bone grafting (2 shoulders), resection for infection (1 shoulder), and internal fixation of a periprosthetic fracture (1 shoulder). Other complications requiring surgery included hematoma treated with evacuation (2 shoulders), dislocation (1 shoulder), and glenosphere disassociation (1 shoulder). Preoperatively, 11 shoulders presented with pseudoparalysis, and the mean active elevation of the remaining 16 shoulders was 43°, with only 1 shoulder demonstrating >90° of active elevation. At the most recent follow-up, 3 shoulders were pseudoparalytic, 11 had <90° of active elevation, 8 had >90° of active elevation, and 3 had active elevation to 90°. The overall mean active elevation of the 25 shoulders that could be assessed was 79°. Preoperatively, only 4 (15%) of the 27 shoulders demonstrated active external rotation past neutral; at the most recent follow-up, 80% of surviving shoulders had active external rotation past neutral. Conclusions: LTT at the time of RSA using an APC has the potential to restore active external rotation in shoulders with proximal humeral bone loss and posterosuperior cuff deficiency. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Pyrocarbon Shoulder Hemiarthroplasty Seems to Outperform Metallic Hemiarthroplasty at a Short-Term Follow-up
Sánchez‐Sotelo, Joaquín , Sanchez-Sotelo, J.

Journal of Bone and Joint Surgery | April 15, 2026 | Volume: 108 | Issue: 8 | Pages: 529-530

10.2106/jbjs.25.01142 Get It

Management of Glenoid Bone Loss in Primary Reverse Total Shoulder Arthroplasty
Marigi, Erick M. , Vasquez-Loret, Amanda, Baird, M. , Hart, Christopher M. , Sperling, John W. , Sánchez‐Sotelo, Joaquín , Marigi, Erick , Yu, Kristin E. , Vasquez-Loret, Amanda , Baird, Michael D , Hart, Christopher M , Sperling, John W , Sanchez-Sotelo, J.

JBJS Open Access | August 7, 2025 | Volume: 10 | Issue: 3 | Pages: No page available

10.2106/jbjs.oa.25.00131 Get It

Abstract » A thorough understanding of glenoid deformity is essential to anticipate intraoperative needs and manage bony deficiencies. Management strategies include eccentric reaming, alternate scapular line baseplate orientation, bone grafting, or metallic augmentation as either “off-the-shelf” or custom baseplates. Accurate implantation of the glenoid component in the presence of glenoid bone loss (GBL) may also benefit from shoulderspecific guides, navigation, or robotic assistance. » GBL can negatively affect outcomes due to compromised bony fixation, altered soft tissue tensioning, and component malposition, which can contribute to impingement, dislocation, aseptic loosening, polyethylene wear, and component failure. » In this article, we provide a comprehensive review of published literature regarding the management of GBL in primary RSA and provide additional insight on the effectiveness of current approaches to manage bony deficiency.
Both Linear and Area-based Methods Provide an Accurate and Reliable Measurement of Anterior Shoulder Instability Related Glenoid Bone Loss
Barret, Hugo , Niggli, Luzia Anna , Athwal, George S. , Hartzler, Robert U. , Sánchez‐Sotelo, Joaquín , Lambers, Floor M. , Sanchez-Sotelo, J.

JBJS Open Access | July 8, 2025 | Volume: 10 | Issue: 3 | Pages: No page available

10.2106/jbjs.oa.25.00022 Get It

Background: Recurrent anterior shoulder instability may lead to capsuloligamentous and bony lesions of the glenoid and humerus. To date, there is no clear consensus on how to best measure anterior glenoid bone loss (GBL) in the setting of recurrent instability. The objective of this study, therefore, was to evaluate the accuracy and reliability of 7 different methods of measuring anterior GBL on three-dimensional models based on computed tomography. Methods: Eight levels of GBL in the anterior and anteroinferior directions were virtually generated in 14 three-dimensional healthy glenoid models. GBL was measured with 7 different methods: based on a height/width ratio (M1), based on surface area within a circle (M2 and M3), based on linear distance within a circle, (M4, M5, and M6), and based on a volume ratio (M7). For each method, the measurement accuracy was assessed by comparing the calculated value with the true amount of generated GBL. The measurement reliability was assessed by computing the score variance and intraclass correlation coefficient. Results: The most accurate (average measurement error of <2% and largest proportion with error <5%) and reliable (ICC >0.96) measurement methods for GBL were M2 (based on surface area) and M5 (based on the linear distance). The average measurement error for the other methods ranged between 3% and 11% for anterior GBL and between 2% and 9% for anteroinferior GBL. For anterior GBL, the measurement increased by an average of 0.5% for each 1% increase in circle radius, leading to an overestimation of GBL with a larger circle diameter Conclusion: The methods for calculating glenoid bone loss performed better for the more common direct anterior bone loss rather than the less common anteroinferior-directed bone loss. Both an area-based method (M2) and linear distance–based method (M5) resulted in accurate and reliable measurements of glenoid bone loss; however, the linear distance–based methods may be easier to perform clinically. The height-width ratio and volume methods were less accurate and reliable. Level of Evidence: Level IV ; case series; diagnostic studies. See Instructions for Authors for a complete description of levels of evidence.
Shear wave elastography of the deltoid muscle in healthy volunteers – quantifying age-dependent normal values
Ivanov, David , Voelkel, Jacob E., Giambini, Hugo , Sánchez‐Sotelo, Joaquín , Dave, Jaydev K. , Kummer, Tobias , Sanchez-Sotelo, J.

Shoulder & Elbow | February 3, 2025 | Volume: 18 | Issue: 2 | Pages: 257-265

10.1177/17585732251315952 Get It

Introduction Reverse shoulder arthroplasty (RSA) is performed for various shoulder pathologies. Inadequate tensioning of the deltoid muscle can lead to complications, highlighting the need for optimization. Preoperative quantification of deltoid health may improve operative execution and outcomes. Shear wave elastography (SWE) quantifies stiffness as a marker for muscle health and tensioning. This study establishes normal reference values for the deltoid in healthy individuals. Methods 40 participants were enrolled, 10 in each 18–30, 31–40, 41–55, and 55 + age groups. Two operators performed SWE in 3 deltoid regions, and the intra- and inter-operator agreement was assessed. Results Mean values were 23.2 ± 4.6, 26.4 ± 5.6, and 17.9 ± 5.2 kPa for the anterior, lateral, and posterior regions. The posterior region did not show any age dependency. However, there were significant differences between the age groups of 18–30 and 55 + years in the anterior (19.7 ± 3.7 vs. 26.7 ± 5.3 kPa) and lateral (22.0 ± 5.4 vs. 30.2 ± 8.8 kPa). Intra-operator reliability ranged from 0.45 to 0.60, and inter-reader agreement from 0.57 to 0.85. Conclusion This study provides reference values of deltoid stiffness which could serve as a comparison with clinical measurements for RSA operative planning and execution and prediction of surgical outcomes.
Management of the infected total elbow arthroplasty
Sánchez‐Sotelo, Joaquín , Sanchez-Sotelo, J.

The Bone & Joint Journal | November 1, 2024 | Volume: 106-B | Issue: 11 | Pages: 1321-1326

10.1302/0301-620x.106b11.bjj-2024-0549.r1 Get It

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.Cite this article: Bone Joint J 2024;106-B(11):1321–1326.
Declining Rate of International Medical Graduates Matching Into Orthopedic Surgery Residency Programs in the United States
Tyagi, Anisha , Sudah, Suleiman Y. , Whitelaw, Kathryn , Haislup, Brett D. , Joshi, Tej , Sanchez-Urgelles, Pablo , Sánchez‐Sotelo, Joaquín , Menendez, Mariano E. , Sanchez-Sotelo, J. , Menendez, Mariano E.

JBJS Open Access | September 20, 2024 | Volume: 9 | Issue: 3 | Pages: No page available

10.2106/jbjs.oa.24.00095 Get It

Introduction: International medical graduates (IMGs) continue to play an important role in the US health care system, but little is known about their trends of matching into highly competitive residencies such as orthopedic surgery. The purpose of this study was to analyze temporal trends of IMG applicants matching into US orthopedic residency programs between 2008 and 2024 and compare them with US allopathic (MD) and osteopathic (DO) graduates. Methods: Orthopedic residency specific data for years 2008 to 2024 was obtained from the National Resident Match Program and Electronic Residency Application Service. Variables collected included total number of programs, total positions offered, number of applicants (MD, DO, and IMG), positions filled, and fill rate for each group. Trends were examined using simple linear regression modeling. Results: The number of orthopedic residency programs increased from 160 (2008) to 218 (2024), with total positions increasing from 636 (2008) to 916 (2024). The IMG fill rate decreased from 2.99% in 2008 to 0.87% in 2024 ( p < 0.01 for linear trend; β −0.069). This corresponds to an absolute number decrease of 19 IMGs in 2008 to 8 in 2024. More specifically, the proportion of US IMGs decreased from 0.94% to 0.66%, and the proportion of non-US IMGs decreased from 2.04% to 0.21%. Over the 17-year study period, a total of 105 US IMGs and 110 non-US IMGs matched into orthopedic surgery. The US MD applicant fill rate decreased significantly from 96.5% to 85.0% ( p < 0.001; β −0.944). The DO applicant fill rate increased significantly from 0.31% to 13.97% ( p < 0.0001; β 0.990). Conclusion: The declining rate of IMGs matching into orthopedic residency programs in the United States underscores the growing challenges faced by IMGs in accessing training in this competitive specialty. The notable increase in DO graduates securing orthopedic residency positions likely reflects the integration of a unified accreditation system for MD and DO residency programs established in 2020. Level of Evidence: Retrospective Cohort Study; IV