Back to Authors

Howard, James L.

https://orcid.org/0000-0002-8118-0589

Mayo Clinic

London Health Sciences Centre

Citations 3

The Effects of Resection Technique on Implant Migration in Single Radius Posterior-Stabilized Total Knee Replacement
Teeter, Matthew G. , Perry, Kevin I. , Yuan, Xunhua , Howard, James L. , Perry, Kevin, Lanting, Brent A.

The Journal of Knee Surgery | December 19, 2018 | Volume: 33 | Issue: 01 | Pages: 078-083

10.1055/s-0038-1676462 Get It

AbstractThe purpose of the present study was to measure the effects of gap balancing and resection techniques on migration of a single total knee replacement implant design. A total of 23 patients (24 knees) were recruited on referral to either a surgeon performing gap balancing or a surgeon performing measured resection and followed prospectively. All patients received a fixed bearing, posterior stabilized total knee replacement implant of a single radius femoral component design with cement fixation, and all aspects of care outside of resection technique were identical. Patients underwent radiostereometric analysis (RSA) at 2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years. Migration of the tibial and femoral components was compared between groups. Tibial component migration was greater at 2 years in the gap balancing group (mean difference = 0.336 mm, p = 0.036), but there was no difference at 1 year. One measured resection and three gap balancing tibial components demonstrated continuous migration > 0.2 mm between years 1 and 2. There was no difference in femoral component migration. Small differences in tibial component migration were found between the gap balancing and measured resection techniques. However, comparing the migration to established predictive thresholds for long-term loosening risk, implants performed with both techniques were found to have equally low revision risk.
Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component
Amanatullah, Derek F. , Howard, James L. , Siman, Homayoun , Trousdale, Robert T. , Mabry, Tad M. , Berry, Daniel J. , Berry, Daniel J

The Bone & Joint Journal | March 3, 2015 | Volume: 97-B | Issue: 3 | Pages: 312-317

10.1302/0301-620x.97b3.34684 Get It

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 patients using a single fluted, tapered, modular femoral stem design. Pre-operative diagnoses included aseptic loosening, infection and peri-prosthetic fracture. Bone loss was categorised pre-operatively as Paprosky types III-IV, or Vancouver B3 in patients with a peri-prosthetic fracture. The mean clinical follow-up was 6.4 years (2 to 12). A total of 47 patients had peri-operative complications, 27 of whom required further surgery. However, most of these further operations involved retention of a well-fixed femoral stem, and 88/92 femoral components (97%) remained in situ. Of the four components requiring revision, three were revised for infection and were well fixed at the time of revision; only one (1%) was revised for aseptic loosening. The most common complications were post-operative instability (17 hips, 19%) and intra-operative femoral fracture during insertion of the stem (11 hips, 12%). Diaphyseal stress shielding was noted in 20 hips (22%). There were no fractures of the femoral component. At the final follow-up 78% of patients had minimal or no pain.Revision THA in patients with extensive proximal femoral bone loss using the Link MP fluted, tapered, modular stem led to a high rate of osseointegration of the stem at mid-term follow-up.Cite this article: Bone Joint J 2015; 97-B:312–17.
Total Hip Arthroplasty with Shortening Subtrochanteric Osteotomy in Crowe Type-IV Developmental Dysplasia
Krych, Aaron J. , Howard, James L. , Trousdale, Robert T. , Cabanela, Miguel E., Berry, Daniel J. , Krych, Aaron J , Berry, Daniel J

Journal of Bone and Joint Surgery | September 15, 2010 | Volume: 92 | Issue: Supplement_1_Part_2 | Pages: 176-187

10.2106/jbjs.j.00061 Get It

BACKGROUND: When surgeons perform total hip arthroplasty for hips with a high dislocation related to developmental dysplasia of the hip, obtaining long-term stable implant fixation and optimizing patient function remain challenges. The purpose of this paper was to evaluate the results of cementless arthroplasty with a simultaneous subtrochanteric shortening osteotomy in a group of patients with Crowe type-IV developmental dysplasia of the hip. METHODS: In a retrospective study, we evaluated the results and complications of twenty-eight consecutive primary cementless total hip arthroplasties in twenty-four patients (twenty women and four men), all of whom had Crowe type-IV developmental dysplasia of the hip. The arthroplasty was performed in combination with a subtrochanteric shortening osteotomy and with placement of the acetabular component at the level of the anatomic hip center. The patients were evaluated at a mean of 4.8 years postoperatively. RESULTS: The mean Harris hip score increased from 43 points preoperatively to 89 points at the time of final follow-up (p < 0.01). Twelve (43%) of the twenty-eight hips had an early or late complication or a reoperation. Two (7%) of the twenty-eight subtrochanteric osteotomies were followed by nonunion. There was one instance of isolated loosening of the femoral stem. One acetabular component loosened, and one acetabular liner disengaged. Four hips dislocated postoperatively. All remaining components were well-fixed at the time of the last radiographic follow-up. No sciatic neurapraxic injuries were identified. CONCLUSIONS: Cementless total hip arthroplasty combined with a subtrochanteric femoral shortening osteotomy in patients with a high hip dislocation secondary to developmental dysplasia was associated with high rates of successful fixation of the implants and healing of the osteotomy site and a mean postoperative Harris hip score of 89 points. The complication rate, however, was substantially higher than that associated with primary total hip arthroplasty in patients with degenerative arthritis. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence. ORIGINAL ABSTRACT CITATION: “Total Hip Arthroplasty with Shortening Subtrochanteric Osteotomy in Crowe Type-IV Developmental Dysplasia” (2009;91:2213-21).