Back to Authors

Haft, Geoffrey F.

https://orcid.org/0000-0001-7371-2576

Mayo Clinic

Sanford Health

Citations 2

Preliminary Study of Motion Preservation Following Posterior Dynamic Distraction Device in Adolescent Idiopathic Scoliosis Patients
Todderud, Julia E , Milbrandt, Todd A. , Floyd, Edward R. , Haft, Geoffrey F. , Albert, Michael , Larson, A. Noelle , Larson, A Noelle , Floyd, Edward, El‐Hawary, Ron

Journal of Pediatric Orthopaedics | July 1, 2024 | Volume: 44 | Issue: 9 | Pages: 524-529

10.1097/bpo.0000000000002739 Get It

Background: Motion-sparing scoliosis surgeries such as the posterior dynamic distraction device (PDDD) are slowly increasing in use. However, there is limited clinical data documenting postoperative motion across the PDDD construct. With this cohort study, we aim to measure sagittal and coronal motion following PDDD. We hypothesize coronal and sagittal spinal motion will be partially preserved across the construct. Methods: Retrospective review of prospectively collected data. Preoperative and minimum 1-year postoperative coronal range of motion across the instrumented levels was compared. Available flexion/extension radiographs were evaluated postoperatively to assess sagittal arc of motion. Radiographs from latest follow-up were used. Results: At a mean of 1.9 years (1 to 5 y), flexibility radiographs were available on 29 patients treated with PDDD (17 thoracic, 12 lumbar). Mean age at surgery was 16 years (12 to 25). Postoperative coronal arc of motion in PDDD patients was 11 degrees (3 to 19 degrees) in the thoracic spine and 10 degrees (0 to 28 degrees) in the lumbar spine. Compared with preoperative motion, the thoracic arc of motion was maintained by 33% (35 to 11 degrees) and lumbar motion was maintained by 30% (34 to 10 degrees). Flexion-extension radiographs were available on 7 patients. Sagittal arc for the upper instrumented vertebral end plate to the lower instrumented vertebral endplate of the cohort was 10 degrees in the thoracic spine (6 to 18) and 14 degrees in the lumbar spine (5 to 21). Sagittal measurements for the changes in the arc of the upper and lower screws on the construct were 4 degrees in the thoracic group (2 to 8) and 9 degrees in the lumbar group (2 to 17). By latest follow-up 11 patients (38%) underwent reoperation, with most cases due to implant breakage (N=4, 14%), extender misalignment (N=2, 7%), and screw misplacement (N=2, 7%). Conclusion: At mean 1.9 years postoperatively, PDDD preserves measurable spinal motion over the construct both in the coronal and the sagittal plane without evidence for autofusion. Coronal arc of motion averages 10 to 12 degrees and sagittal arc of motion ranged from 4 to 14 degrees, although this varies by patient. This study confirms that PDDD for pediatric scoliosis preserves a measurable degree of postoperative flexibility both in the sagittal and coronal planes. Level of Evidence: Level II—therapeutic study.
Are Serum Ion Levels Elevated in Pediatric Patients With Metal Implants?
Mathew, Smitha , Xie, Yong, Bagheri, Leila, Claton, Liam E. , Chu, Lin, Badreldin, Amr, Wijnen, André J. van , Haft, Geoffrey F. , Milbrandt, Todd A. , van Wijnen, Andre J , Chu, Lin, Badreldin, Amr A. , Abdel, Matthew P. , Larson, A. Noelle

Journal of Pediatric Orthopaedics | October 8, 2021 | Volume: 42 | Issue: 3 | Pages: 162-168

10.1097/bpo.0000000000001957 Get It

Background: Previous studies report elevated serum titanium (Ti) levels in children with spinal implants. To provide additional data on this topic, we sought to assess serum ion levels at multiple timepoints in pediatric patients with growing spine devices, spinal fusion instrumentation, and extremity implants placed for fracture treatment. We hypothesized that serum Ti, cobalt (Co), and chromium (Cr) levels would be elevated in pediatric patients with growing spine devices compared with patients with extremity implants. Methods: Pediatric patients undergoing any primary spine implant placement, those with spine implant revision or removal surgery and patients with other appendicular implant removal had serum Ti, Co, and Cr ion levels drawn at the time of surgery. Fifty-one patients (12 growing spine devices, 13 fusions, and 26 extremity implants) had one set of labs, 31 of whom had labs drawn both preoperatively and postoperatively. Biopsies obtained from tissue specimens at the time of implant revision were analyzed histologically for the presence of metal debris and macrophage activity. Results: Patients with growing spine implants had elevated serum Ti (3.3 vs. 1.9 ng/mL, P=0.01) and Cr levels (1.2 vs. 0.27 ng/mL, P=0.01) in comparison to patients with fusion rods or extremity implants. With respect to patients with extremity implants, patients with growing spine devices had elevated serum Ti (3.3 vs. 0.98 ng/mL, P=0.013), Co (0.63 vs. 0.26 ng/mL, P=0.017), and Cr levels (1.18 vs. 0.26 ng/mL, P=0.005). On matched pairs analysis, patients who had labs drawn before and after spine implantation had significant increase in serum Ti levels (0.57 vs. 3.3 ng/mL, P=0.02). Histology of tissue biopsies adjacent to growing spine implants showed presence of metal debris and increased macrophage activity compared with patients with extremity implants. Conclusion: Serum Ti, Co, and Cr levels are elevated in children with spinal implants compared with those with extremity implants, particularly in those with growing spine devices. However, the clinical significance of these findings remains to be determined. Level of Evidence: Level II—prospective comparative study.