Aims Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. Methods An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. Results Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. Conclusion This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695–1701.
The use of highly crosslinked polyethylene in total knee arthroplasty
Advances in polyethylene (PE) in total hip arthroplasty have led to interest and increased use of highly crosslinked PE (HXLPE) in total knee arthroplasty (TKA). Biomechanical data suggest improved wear characteristics for HXLPE inserts over conventional PE in TKA. Short-term results from registry data and few clinical trials are promising. Our aim is to present a review of the history of HXLPEs, the use of HXLPE inserts in TKA, concerns regarding potential mechanical complications, and a thorough review of the available biomechanical and clinical data.Cite this article: Bone Joint J 2017;99-B:996–1002.
Catastrophic Head-Neck Dissociation of a Modular Cementless Femoral Component
Case: We report two cases of modular head-neck junction failure involving the Stryker Accolade TMZF stem leading to sudden dissociation of the femoral head from the stem. Both patients presented with mechanical symptoms in the hip followed by pain and hip dysfunction. Disassembly of the head and deformation of the male taper were seen on preoperative radiographs. Intraoperatively, both patients had substantial metallosis with a markedly damaged taper requiring stem revision. Conclusion: We recommend regular clinical and radiographic surveillance of patients with the Stryker Accolade TMZF stem, especially those patients with pain and/or mechanical symptoms.