AimsThis study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA).MethodsFrom 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded.ResultsSurvivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years.ConclusionAfter ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110.
Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components
Background: The cementation of a new liner into a well-fixed acetabular component is common during revision total hip arthroplasty (THA) for many indications, but most commonly for lack of a modern, compatible, highly cross-linked polyethylene (HXLPE) liner. However, little is known about the intermediate-term to long-term durability of this strategy. The purpose of this study was to evaluate the implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new HXLPE liner into a well-fixed acetabular component. Methods: We retrospectively identified 323 revision THAs in which a nonconstrained HXLPE liner was cemented into a well-fixed acetabular component. The mean age at the time of the revision THA was 63 years, and 50% of patients were female. The most common indications for revision THA were polyethylene wear and osteolysis (48%), aseptic femoral loosening (35%), and hip instability (8%). The mean follow-up was 9 years. Results: Polyethylene liner failure occurred in 11 cases (3%). In all cases, the cemented liner dissociated from the acetabular component. At 10 years, the survivorship free from any revision was 80% (95% confidence interval [CI], 75% to 84%) and the survivorship free from any reoperation was 77% (95% CI, 72% to 82%). The most common reason for re-revision was dislocation (45% of reoperations). A dislocation occurred in 17% of cases. Hips that underwent revision for instability were significantly more likely to dislocate compared with hips that underwent revision for liner wear (hazard ratio [HR], 2.3 [95% CI, 1.2 to 4.5]; p = 0.02). Elevated rim or face-changing liners were significantly more likely to dissociate than flat liners (HR, 9.0 [95% CI, 1.2 to 70.6]; p = 0.04). Conclusions: Cementation of a nonconstrained HXLPE liner into a well-fixed acetabular component during revision THA provided durable fixation with only a small number of failures at the cement interface (3%). Instability after this procedure remains a concern, but this is multifactorial in nature. These data support the continued use of this technique, when necessary, during revision THA. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Excellent two-year survivorship of 3D-printed metaphyseal cones in revision total knee arthroplasty
AimsMetaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system.MethodsWe reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m2(18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6).ResultsSurvivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully.ConclusionNovel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115.