AbstractBackgroundAlthough the safety and therapeutic efficacy of COVID‐19 convalescent plasma (CCP) has been extensively evaluated, the safety of CCP donation has not been explored in a multi‐institutional context.Study design and methodsNine blood collection organizations (BCOs) participated in a multi‐institutional donor hemovigilance effort to assess the safety of CCP donation. Donor adverse events (DAEs) were defined according to the Standard for Surveillance of Complications Related to Blood Donation, and severity was assessed using the severity grading tool. Multivariate analysis was performed to determine attributes associated with DAE severity.ResultsThe overall DAE rate was 37.7 per 1000 donations. Repeat apheresis and apheresis‐naïve donors experienced adverse event rates of 19.9 and 49.8 per 1000 donations, respectively. Female donors contributed 51.9% of CCP donations with a DAE rate of 49.4 per 1000 donations. The DAE rate for male donors was 27.4 per 1000 donations. Vasovagal reactions accounted for over half of all reported DAEs (51.1%). After adjustment, volume of CCP donated was associated with vasovagal reaction severity (odds ratio [OR] 6.5, 95% confidence interval [CI] 2.5–17.1). Donor age and donation history were also associated with DAE severity. Considerable differences in DAE types and rates were observed across the participating BCOs despite the use of standardized hemovigilance definitions.ConclusionThe safety of CCP donation appears comparable to that of conventional apheresis plasma donation with similar associated risk factors for DAE types and severity.
NT‐proBNP levels in the identification and classification of pulmonary transfusion reactions
AbstractBackgroundConsensus definitions for transfusion‐related acute lung injury (TRALI) and transfusion‐associated circulatory overload (TACO) have recently been revised; however, pulmonary transfusion reactions remain difficult to diagnose. We hypothesized that N‐terminal pro‐brain natriuretic peptide (NT‐proBNP) levels could have utility in the identification and classification of pulmonary transfusion reactions.Study design and methodsWe performed a secondary analysis of a case‐control study of pulmonary transfusion reactions at four academic hospitals. We evaluated clinical data and measured NT‐proBNP levels prior to and following transfusion in patients with TACO (n = 160), transfused acute respiratory distress syndrome (ARDS) [n = 51], TRALI [n = 12], TACO/TRALI [n = 7], and controls [n = 335]. We used Wilcoxon Rank‐Sum tests to compare NT‐proBNP levels, and classification and regression tree (CART) algorithms to produce a ranking of covariates in order of relative importance for differentiating TACO from transfused controls.ResultsPre‐transfusion NT‐proBNP levels were elevated in cases of transfused ARDS and TACO (both P < .001) but not TRALI (P = .31) or TACO/TRALI (P = .23) compared to transfused controls. Pre‐transfusion NT‐proBNP levels were higher in cases of transfused ARDS or TRALI with a diagnosis of sepsis compared to those without (P < .05 for both). CART analyses resulted in similar differentiation of patients with TACO from transfused controls for models utilizing either NT‐proBNP levels (AUC 0.83) or echocardiogram results (AUC 0.80).ConclusionsNT‐proBNP levels may have utility in the classification of pulmonary transfusion reactions. Prospective studies are needed to test the predictive utility of pre‐transfusion NT‐proBNP in conjunction with other clinical factors in identifying patients at risk of pulmonary transfusion reactions.
Inpatient Mortality and Length of Stay Among Direct-Acting Oral Anticoagulant (DOAC) and Warfarin Users Presenting with Major Hemorrhage
Abstract Background: Use of direct-acting oral anticoagulants (DOAC) is increasingly common among patients with atrial fibrillation and venous thromboembolic disease. Differences in the mechanisms of action as compared to warfarin could impact transfusion patterns and clinical outcomes in patients, especially for those presenting with major hemorrhage. The management of patients taking these newer medications and corresponding outcomes are relevant to optimizing clinical decision making in situations of major hemorrhage. Methods: We tested the hypothesis that inpatient all-cause mortality among patients presenting with major hemorrhage differs based on the home-administered anticoagulant medication class (DOAC versus warfarin). A cohort of patients presenting to twelve US hospitals from 2013 to 2016 was identified using the Recipient Epidemiology and Donor Evaluation Study (REDS)-III Recipient Database. Primary ICD diagnosis codes, issued blood products, laboratory data, and early mortality events were used in the application of the International Society on Thrombosis and Hemostasis definition of major hemorrhage. Exposure status was defined as a record of home-administered DOAC (apixaban, dabigatran, edoxaban, or rivaroxaban; exposed) or warfarin (non-exposed). Patients with multiple encounters and those transferred into or out of network were excluded from the analysis. Proportional hazards regression was used to compare all-cause mortality and hospital length of stay. We then repeated the analysis using a cohort matched on propensity scores to account for confounding by age, gender, concurrent aspirin and anti-platelet use, liver and renal dysfunction, cancer, CHA2DS2-VASc score, traumatic injury, and hospital. We then repeated the propensity score matched analysis stratified by anatomic location of bleed and traumatic injury. Results: More than 1.5 million hospitalizations were screened for eligibility. Exclusion of minors, outpatients, hospitalizations without a medication of interest, absence of major hemorrhage, multiple hospitalizations, and hospital transfers resulted in 3,731 patients available for the unadjusted analysis. Inpatient all-cause mortality was lower among DOAC users when the entire cohort was considered (HR = 0.60, 95%CI 0.45 - 0.80, p=0.0005). Implementation of propensity score matching to account for confounding abrogated this difference (HR=0.84, 95%CI 0.58 - 1.22, p=0.36). Time to hospital discharge was shorter for DOAC users (HR = 1.17, 95%CI 1.05 - 1.30, p=0.0034). Transfusion patterns were similar by medication, except for plasma transfusion occurring in 42% of warfarin encounters and 11% of DOAC encounters. Vitamin K was administered in 63% of warfarin encounters, whereas specific DOAC reversal agents were largely unavailable during the analysis period [used in 5 (1%) DOAC encounters]. There were no statistically significant differences in inpatient all-cause mortality in the stratified analysis (warfarin as reference): HR = 0.69 (95%CI 0.31 - 1.55) for traumatic head injuries; HR = 1.10 (95%CI 0.62 - 1.95) for non-traumatic head injuries; HR = 0.62 (95%CI 0.20 - 1.94) for traumatic, non-head injuries; and HR = 0.69 (95%CI 0.29 - 1.63) for non-traumatic, non-head injuries. Conclusions: Analysis of a population taking oral anticoagulation and presenting with major hemorrhage showed that transfusion of plasma was more commonly employed to treat major hemorrhage among warfarin users than DOAC users. Inpatient all-cause mortality was lower among DOAC users in the overall cohort; however, accounting for potential confounding factors using propensity score matching abrogated this difference. Hospital length of stay was shorter for DOAC users compared to warfarin users. Stratification by location of bleed and traumatic injury did not alter these findings. Less plasma use and a shorter length of hospitalization in this study, combined with no observable difference in inpatient all-cause mortality, suggests that outcomes following major hemorrhage are at least no different for DOAC users as compared to warfarin users. Disclosures Mast: Novo Nordisk: Research Funding. Kor:NIH: Consultancy; NIH: Research Funding; UpToDate: Patents & Royalties; CSL Behring: Honoraria.
Contemporary Risk Factors and Outcomes of Transfusion-Associated Circulatory Overload*
Objectives: Transfusion-associated circulatory overload is characterized by hydrostatic pulmonary edema following blood transfusion. Restrictive transfusion practice may affect the occurrence and severity of transfusion-associated circulatory overload in critically ill patients. We sought to examine contemporary risk factors and outcomes for transfusion-associated circulatory overload. Design: Case-control study. Setting: Four tertiary care hospitals. Patients: We prospectively enrolled 200 patients with transfusion-associated circulatory overload identified by active surveillance and 405 controls matched by transfusion intensity. Interventions: None. Measurements and Main Results: Among 20,845 transfused patients who received 128,263 blood components from May 2015 until July 2016, transfusion-associated circulatory overload incidence was one case per 100 transfused patients. In addition to cardiovascular comorbidities, multivariable analysis identified the following independent predictors of transfusion-associated circulatory overload: acute kidney injury, emergency surgery, pretransfusion diuretic use, and plasma transfusion—the latter especially in females. Compared with matched controls, transfusion-associated circulatory overload cases were more likely to require mechanical ventilation (71% vs 49%; p < 0.001), experienced longer intensive care and hospital lengths of stay following transfusion, and had higher mortality (21% vs 11%; p = 0.02) even after adjustment for other potentially confounding variables. Conclusions: Despite restrictive transfusion practice, transfusion-associated circulatory overload remains a frequent complication of transfusion and is an independent risk factor for in-hospital morbidity and mortality. In addition to cardiovascular and renal risk factors, plasma transfusion was associated with transfusion-associated circulatory overload after controlling for other covariates. Additional research is needed to examine the benefit of reduced erythrocyte or plasma exposure in patients at high risk for transfusion-associated circulatory overload.
Demographic and epidemiologic characterization of transfusion recipients from four US regions: evidence from the REDS‐III recipient database
BACKGROUNDBlood transfusion is one of the most common medical procedures during hospitalization in the United States. To understand the benefits of transfusion while mitigating potential risks, a multicenter database containing detailed information on transfusion incidence and recipient outcomes would facilitate research.STUDY DESIGN AND METHODSThe Recipient Epidemiology and Donor Evaluation Study‐III (REDS‐III) program has developed a comprehensive transfusion recipient database utilizing data from hospital electronic health records at 12 participating hospitals in four geographic regions. Inpatient and outpatient data on transfusion recipients from January 1, 2013 to December 31, 2014 included patient age, sex, ethnicity, primary diagnosis, type of blood product provided, issue location, pretransfusion and post‐transfusion hemoglobin (Hgb), and hospital outcomes. Transfusion incidence per encounter was calculated by blood product and various patient characteristics.RESULTSDuring the 2‐year study period, 80,362 (12.5%) inpatient encounters involved transfusion. Among inpatients, the most commonly transfused blood products were red blood cells (RBCs; 10.9% of encounters), followed by platelets (3.2%) and plasma (2.9%). Among patients who received transfusions, the median number of RBC units was one, the pretransfusion Hgb level was 7.6 g/dL, and the Hgb increment per unit was 1.4 g/dL. Encounter mortality increased with patient age, the number of units transfused, and the use of platelet or plasma products. The most commonly reported transfusion reaction was febrile nonhemolytic.CONCLUSIONThe database contains comprehensive data regarding transfusion use and patient outcomes. The current report describes an evaluation of the first 2 years of a planned, 4‐year, linked blood donor‐component‐recipient database, which represents a critical new resource for transfusion medicine researchers.
Incidence and clinical characteristics of transfusion‐associated circulatory overload using an active surveillance algorithm
BackgroundThe concordance of haemovigilance criteria developed for surveillance of transfusion‐associated circulatory overload (TACO) with its clinical diagnosis has not been assessed. In a pilot study to evaluate an electronic screening algorithm, we sought to examine TACO incidence and application of haemovigilance criteria in patients with post‐transfusion pulmonary oedema.Study Design and MethodsFrom June to September 2014, all transfused adult inpatients at four academic hospitals were screened with an algorithm identifying chest radiographs ordered within 12 h of blood component release. Patients with post‐transfusion pulmonary oedema underwent case adjudication by an expert panel. TACO incidence was calculated, and clinical characteristics were compared with other causes of post‐transfusion pulmonary oedema.ResultsAmong 4932 transfused patients, there were 3412 algorithm alerts, 50 cases of TACO and 47 other causes of pulmonary oedema. TACO incidence was 1 case per 100 patients transfused. TACO classification based on two sets of haemovigilance criteria (National Healthcare Safety Network and proposed revised International Society for Blood Transfusion) was concordant with expert panel diagnosis in 57% and 54% of reviewed cases, respectively. Although the majority of clinical parameters did not differentiate expert panel adjudicated TACO from other cases, improved oxygenation within 24 h of transfusion did (P = 0·01).ConclusionsThe incidence of TACO was similar to that observed in prior studies utilizing active surveillance. Case classification by haemovigilance criteria was frequently discordant with clinical diagnoses of TACO in patients with post‐transfusion pulmonary oedema. Improvements in oxygenation within 24 h of transfusion merit further evaluation in the diagnosis of TACO.
A multicenter study of plasma use in the United States
BackgroundDetailed information regarding plasma use in the United States is needed to identify opportunities for practice improvement and design of clinical trials of plasma therapy.Study Design and MethodsTen US hospitals collected detailed medical information from the electronic health records for 1 year (2010‐2011) for all adult patients transfused with plasma.ResultsA total of 72,167 units of plasma were transfused in 19,596 doses to 9269 patients. The median dose of plasma was 2 units (interquartile range, 2‐4; range 1‐72); 15% of doses were 1 unit, and 45% were 2 units. When adjusted by patient body weight (kg), the median dose was 7.3 mL/kg (interquartile range, 5.5‐12.0). The median pretransfusion international normalized ratio (INR) was 1.9 (25%‐75% interquartile range, 1.6‐2.6). A total of 22.5% of plasma transfusions were given to patients with an INR of less than 1.6 and 48.5% for an INR of 2.0 or more. The median posttransfusion INR was 1.6 (interquartile range, 1.4‐2.0). Only 42% of plasma transfusions resulted in a posttransfusion INR of less than 1.6. Correction of INR increased as the plasma dose increased from 1 to 4 units (p < 0.001). There was no difference in the INR response to different types of plasma. The most common issue locations were general ward (38%) and intensive care unit (ICU; 42%).ConclusionThis large database describing plasma utilization in the United States provides evidence for both inadequate dosing and unnecessary transfusion. Measures to improve plasma transfusion practice and clinical trials should be directed at patients on medical and surgical wards and in the ICU where plasma is most commonly used.
A multicenter evaluation of a new therapeutic plasma exchange procedure
BackgroundThe AMICUS (Fenwal, Inc.) was cleared in the United States for platelet (PLT) and plasma collection in 1996 with subsequent clearances for the collection of other blood products. Although not previously used for therapeutic plasma exchange (TPE), new disposables, software, and hardware were developed to enable TPE on the AMICUS.Study Design and MethodsA multicenter, randomized, nonblinded, crossover paired treatment protocol was performed. Thirty patients with orders for at least two TPE procedures were randomly assigned to the AMICUS or the COBE Spectra (TerumoBCT) for the first treatment. Each patient was crossed over to the other device using the same procedure settings from the first procedure. The primary objective compared efficiency of plasma removal (EPR) with secondary objectives of comparing PLT and hemoglobin (Hb) waste plasma content, coagulation factor and complement activation, fluid balance tracking accuracy, procedure length, and adverse events.ResultsThe EPR for the AMICUS (81.9 ± 7.62%) was superior to that of the COBE Spectra (75.2 ± 6.29%; p = 0.00001). The AMICUS also demonstrated statistically higher fluid balance accuracy (99.84%) compared to that of the COBE Spectra (98.83%; p < 0.0001) and a statistically shorter procedure time (103.9 ± 30.8 vs. 110.5 ± 27.1 min, p < 0.001). No significant differences with regard to PLT and Hb content in the waste plasma, change in patient PLT count, or changes in markers of coagulation and complement cascade activation were seen. Frequency and severity of adverse reactions were similar.ConclusionThe AMICUS separator can effectively perform TPE. The AMICUS demonstrated superior plasma removal efficiency compared to the COBE Spectra with no evidence of significant differences in PLT removal, hemolysis, and coagulation or complement activation.