Back to Authors

Reik, Rita A.

Mayo Clinic

22Oneblood, Fort Lauderdale, FL

Citations 2

Transfusion Efficacy and Safety of Amustaline/Glutathione Pathogen-Reduced Red Blood Cells: Results of a Randomized, Controlled Phase III Trial
Snyder, Edward L. , Sekela, Michael , Toyoda, Yoshiya , Alsammak, Mohamed , Sodha, Neel R. , Beaver, Thomas M., Pelletier, J. Peter R. , Gorham, James D. , McNeil, John S. , Pearl, Ronald G. , Nuttall, Gregory A. , Reece, T. Brett , Davenport, Robertson D., Benharash, Peyman , Lopez‐Plaza, Ileana, Sadler, Patrick, Reik, Rita A., Mufti, Nina, Varrone, Jeanne, Benjamin, Richard J , Welsby, Ian J , Beaver, Thomas M. , Sniecinski, Roman M , Sarode, Ravi , Kaplan, Alesia , Ipe, Tina S. , Gammon, Richard R. , Corash, Laurence M , Liu, Kathy

Blood | December 5, 2024 | Volume: 144 | Issue: Supplement 1 | Pages: 5592-5592

10.1182/blood-2024-202164 Get It

Introduction: Red blood cell (RBC) transfusion is a lifesaving intervention with a low but persistent risk of transfusion-transmitted infection. Amustaline/glutathione RBC pathogen-reduction (PR) technology is designed to proactively inactivate a broad spectrum of viruses, bacteria, protozoa and leukocytes by chemically crosslinking nucleic acids and preventing replication and transcription. The Red Cell Pathogen Inactivation (ReCePI) trial was a Phase III, double-blinded, randomized non-inferiority study comparing PR and conventional RBCs for the support of acute anemia. Methods/Study Design: Complex cardiac or thoracic-aorta surgery patients received conventional (Control) or PR RBCs (Test) during and for 7 days after surgery. The protocol was conducted with ethics committee approval at all participating centers and written informed consent from all participants. Hemoglobin levels, blood utilization and serum creatinine were assessed as indicators of efficacy and oxygenation of tissues (Karkouti et al. Br J Anaesth. 2012; 109 Suppl 1: i29-i38). The primary endpoint was the incidence of acute kidney injury (AKI) measured as change in serum creatinine from baseline within 48 hours of surgery, a predictor of adverse postoperative outcomes including mortality by Day 30 post-surgery (Lassnig et al. Am Soc Nephrol 2004; 1597-1605). Secondary endpoints included AKI occurring up to 7 days post-surgery (KDIGO Clinical Practice Guideline for AKI, Kidney Inter, Suppl. 2012;2:1-138); death or the need for renal replacement therapy by 30 days post-surgery; PR RBC-specific antibodies; and death by day 75 post-surgery. With >292 subjects enrolled, the study had 80% power to demonstrate non-inferiority, assuming an AKI incidence of 30% with conventional RBCs and a non-inferiority margin of half the conventional RBC rate. Under these circumstances, an absolute treatment increase of 5% in the AKI rate in the PR RBC arm would fail the non-inferiority test. This work was supported by a contract with the US Biomedical Advanced Research and Development Authority (HHS010020160009c) with Cerus Corporation. Results: Five-hundred and eighty-one subjects were randomized and 321 (55%) transfused in 18 US hospitals. In the modified intent-to-treat analysis subjects receiving Test and Control RBCs had similar median [IQR] total blood loss (1500 [940-2475] mL Test, 1733 [1060-2880] mL Control, p=0.310) and comparable median hemoglobin levels at baseline and immediately post-surgery (9.8 [8.9-10.9] g/dL Test, 9.6 [8.6-10.6] g/dL Control, p=0.157) and for 7 days after surgery, The PR RBC arm was transfused with fewer RBCs, measured as total RBC Hb transfused over 7-days (169.0 [102.0-240.0] g Hb PR arm, 188.0 [126.0-295.0] g Hb, conventional RBC arm, p=0.008). The incidence of AKI was 29.3% (46/157) for Test and 28.0% (45/161) for Control. The treatment difference was 0.74% (95% CI -8.9, 10.4%, non-inferiority margin 14.0%, p=0.001 for non-inferiority). Non-inferiority was also achieved by the per protocol analysis. Average mean change in serum creatinine within 48 hours of surgery was comparable (Test 0.020, Control 0.23 mg/dL, P=0.515). Adverse events, serious adverse events and deaths on study were not different. Five of 159 (3.1%) PR RBC recipients developed low titer PR RBC-specific antibodies without clinical signs of hemolysis. Flow cytometry analysis revealed persistent circulating PR RBCs with uniform antigen loss (modulation). Low level human IgG antibody binding was demonstrated in 3 of 5 subjects. Conclusions: PR RBCs showed equivalent hemoglobin support for acute bleeding patients undergoing cardiac or thoracic-aorta surgery while using less transfused total RBC Hb over 7 days. The incidence of AKI in patients transfused with PR RBCs was non-inferior to that observed with conventional RBCs, indicative of effective tissue oxygenation. Treatment-related antibodies to PR-RBC were observed only in Test subjects, the antibodies were low titer, transient, without clinical hemolysis, and persistent circulating PR RBCs were detected with modulated low level acridine antigen expression (www.clinicaltrials.gov #NCT03459287).
The safety of COVID‐19 convalescent plasma donation: A multi‐institutional donor hemovigilance study
Cho, Joseph H. , Rajbhandary, Srijana , Buren, Nancy L. Van , Al‐Ghafry, Maha , Fridey, Joy, Dy, Beth A., Ziman, Alyssa , Schreiber, George B. , Gammon, Richard R. , Reik, Rita A., Stubbs, James R. , Buskirk, Camille M. van , Kamel, Hany , Townsend, Mary , Zeller, Michelle P. , Gottschall, Jerome L. , van Buren, Nancy L , Fung, Mark K , Ziman, Alyssa , Schreiber, George B , Gammon, Richard R , Stubbs, James R , van Buskirk, Camille M, Townsend, Mary J

Transfusion | July 6, 2021 | Volume: 61 | Issue: 9 | Pages: 2668-2676

10.1111/trf.16572 Get It

AbstractBackgroundAlthough the safety and therapeutic efficacy of COVID‐19 convalescent plasma (CCP) has been extensively evaluated, the safety of CCP donation has not been explored in a multi‐institutional context.Study design and methodsNine blood collection organizations (BCOs) participated in a multi‐institutional donor hemovigilance effort to assess the safety of CCP donation. Donor adverse events (DAEs) were defined according to the Standard for Surveillance of Complications Related to Blood Donation, and severity was assessed using the severity grading tool. Multivariate analysis was performed to determine attributes associated with DAE severity.ResultsThe overall DAE rate was 37.7 per 1000 donations. Repeat apheresis and apheresis‐naïve donors experienced adverse event rates of 19.9 and 49.8 per 1000 donations, respectively. Female donors contributed 51.9% of CCP donations with a DAE rate of 49.4 per 1000 donations. The DAE rate for male donors was 27.4 per 1000 donations. Vasovagal reactions accounted for over half of all reported DAEs (51.1%). After adjustment, volume of CCP donated was associated with vasovagal reaction severity (odds ratio [OR] 6.5, 95% confidence interval [CI] 2.5–17.1). Donor age and donation history were also associated with DAE severity. Considerable differences in DAE types and rates were observed across the participating BCOs despite the use of standardized hemovigilance definitions.ConclusionThe safety of CCP donation appears comparable to that of conventional apheresis plasma donation with similar associated risk factors for DAE types and severity.