Back to Authors

Ness, Paul M.

Mayo Clinic

Johns Hopkins University

Citations 4

U.S. cities will not meet blood product resuscitation standards during major mass casualty incidents: Results of a THOR‐AABB working party prospective analysis
Cannon, Jeremy W. , Igra, Noah M, Borge, P. Dayand , Cap, Andrew P., Doughty, Heidi , Geng, Zhi , Guzmán, Jessica, Ness, Paul M., Jenkins, Donald H. , Rajbhandary, Srijana , Schmulevich, Daniela , Stubbs, James R. , Yazer, Mark H. , Spinella, Philip C. , Devine, Dana V , Rajbhandary, Srijana , Stubbs, James R , Yazer, Mark H , Spinella, Philip C , Cap, Andrew P., Devine, Dana V. , Geng, Zhi, Wiebe, Douglas J.

Transfusion | June 22, 2022 | Volume: 62 | Issue: S1 | Pages: No page available

10.1111/trf.16960 Get It

AbstractBackgroundMass casualty incidents (MCIs) create an immediate surge in blood product demand. We hypothesize local inventories in major U.S. cities would not meet this demand.Study Design and MethodsA simulated blast in a large crowd estimated casualty numbers. Ideal resuscitation was defined as equal amounts of red blood cells (RBCs), plasma, platelets, and cryoprecipitate. Inventory was prospectively collected from six major U.S. cities at six time points between January and July 2019. City‐wide blood inventories were classified as READY (>1 U/injured survivor), DEFICIENT (<10 U/severely injured survivor), or RISK (between READY and DEFICIENT), before and after resupply from local distribution centers (DC), and features of DEFICIENT cities were identified.ResultsThe simulated blast resulted in 2218 injured survivors including 95 with severe injuries. Balanced resuscitation would require between 950 and 2218 units each RBC, plasma, platelets and cryoprecipitate. Inventories in 88 hospitals/health systems and 10 DCs were assessed. Of 36 city‐wide surveys, RISK inventories included RBCs (n = 16; 44%), plasma (n = 24; 67%), platelets (n = 6; 17%), and cryoprecipitate (n = 22; 61%) while DEFICIENT inventories included platelets (n = 30; 83%) and cryoprecipitate (n = 12; 33%). Resupply shifted most RBC and plasma inventories to READY, but some platelet and cryoprecipitate inventories remained at RISK (n = 24; 67% and n = 12; 33%, respectively) or even DEFICIENT (n = 11; 31% and n = 6; 17%, respectively). Cities with DEFICIENT inventories were smaller (p <.001) with fewer blood products per trauma bed (p <.001).DiscussionIn this simulated blast event, blood product demand exceeded local supply in some major U.S. cities. Options for closing this gap should be explored to optimize resuscitation during MCIs.
Civilian walking blood bank emergency preparedness plan
Holcomb, John B. , Spinella, Philip C. , Apelseth, Torunn Oveland , Butler, Frank K., Cannon, Jeremy W. , Cap, Andrew P., Corley, Jason B., Doughty, Heidi , Fitzpatrick, Michael H., Goldkind, Sara F., Gurney, Jennifer M. , Homer, Mary J. , Jenkins, Donald H. , Moore, Eugene, Ness, Paul M., Schreiber, Martin A. , Shinar, Eilat , Sloan, Steve, Stubbs, James R. , Taylor, Audra L., Ward, Kevin R. , Waltman, Elizabeth, Yazer, Mark H. , Jansen, Jan O , Strandenes, Geir , Stubbs, James R , Yazer, Mark , Spinella, Philip C , Apelseth, Torunn , Holcomb, John B , Cap, Andrew P., Ilstrup, Sarah J. , Jansen, Jan O. , Marques, Marisa B. , O’Connor, Kevin C. , Strandenes, Geir

Transfusion | July 16, 2021 | Volume: 61 | Issue: S1 | Pages: No page available

10.1111/trf.16458 Get It

Abstract Background The current global pandemic has created unprecedented challenges in the blood supply network. Given the recent shortages, there must be a civilian plan for massively bleeding patients when there are no blood products on the shelf. Recognizing that the time to death in bleeding patients is less than 2 h, timely resupply from unaffected locations is not possible. One solution is to transfuse emergency untested whole blood (EUWB), similar to the extensive military experience fine‐tuned over the last 19 years. While this concept is anathema in current civilian transfusion practice, it seems prudent to have a vetted plan in place. Methods and Materials During the early stages of the 2020 global pandemic, a multidisciplinary and international group of clinicians with broad experience in transfusion medicine communicated routinely. The result is a planning document that provides both background information and a high‐level guide on how to emergently deliver EUWB for patients who would otherwise die of hemorrhage. Results and Conclusions Similar plans have been utilized in remote locations, both on the battlefield and in civilian practice. The proposed recommendations are designed to provide high‐level guidance for experienced blood bankers, transfusion experts, clinicians, and health authorities. Like with all emergency preparedness, it is always better to have a well‐thought‐out and trained plan in place, rather than trying to develop a hasty plan in the midst of a disaster. We need to prevent the potential for empty shelves and bleeding patients dying for lack of blood.
Whole blood for hemostatic resuscitation of major bleeding
Spinella, Philip C. , Pidcoke, Heather F. , Hervig, Tor , Fisher, Andrew D , Jenkins, Donald H. , Yazer, Mark H. , Stubbs, James R. , Murdock, Alan D., Sailliol, A., Ness, Paul M., Cap, Andrew P., Stubbs, James, Strandenes, Geir , Cap, Andrew P., Spinella, Philip C

Transfusion | April 21, 2016 | Volume: 56 | Issue: S2 | Pages: No page available

10.1111/trf.13491 Get It

Recent combat experience reignited interest in transfusing whole blood (WB) for patients with life‐threatening bleeding. US Army data indicate that WB transfusion is associated with improved or comparable survival compared to resuscitation with blood components. These data complement randomized controlled trials that indicate that platelet (PLT)‐containing blood products stored at 4°C have superior hemostatic function, based on reduced bleeding and improved functional measures of hemostasis, compared to PLT‐containing blood products at 22°C. WB is rarely available in civilian hospitals and as a result is rarely transfused for patients with hemorrhagic shock. Recent developments suggest that impediments to WB availability can be overcome, specifically the misconceptions that WB must be ABO specific, that WB cannot be leukoreduced and maintain PLTs, and finally that cold storage causes loss of PLT function. Data indicate that the use of low anti‐A and anti‐B titer group O WB is safe as a universal donor, WB can be leukoreduced with PLT‐sparing filters, and WB stored at 4°C retains PLT function during 15 days of storage. The understanding that these perceived barriers are not insurmountable will improve the availability of WB and facilitate its use. In addition, there are logistic and economic advantages of WB‐based resuscitation compared to component therapy for hemorrhagic shock. The use of low‐titer group O WB stored for up to 15 days at 4°C merits further study to compare its efficacy and safety with current resuscitation approaches for all patients with life‐threatening bleeding.
A multicenter study of plasma use in the United States
Triulzi, Darrell J., Gottschall, Jerome L. , Murphy, Edward L. , Wu, Yanyun , Ness, Paul M., Kor, Daryl J. , Fleischmann, Debra, Chowdhury, Dhuly , Brambilla, Donald , (REDS‐III), NHLBI Recipient Epidemiology and Donor Evaluation Study‐III, Kor, Daryl, Roubinian, Nareg H. , (REDS‐III), NHLBI Recipient Epidemiology and Donor Evaluation Study‐III

Transfusion | December 19, 2014 | Volume: 55 | Issue: 6 | Pages: 1313-1319

10.1111/trf.12970 Get It

BackgroundDetailed information regarding plasma use in the United States is needed to identify opportunities for practice improvement and design of clinical trials of plasma therapy.Study Design and MethodsTen US hospitals collected detailed medical information from the electronic health records for 1 year (2010‐2011) for all adult patients transfused with plasma.ResultsA total of 72,167 units of plasma were transfused in 19,596 doses to 9269 patients. The median dose of plasma was 2 units (interquartile range, 2‐4; range 1‐72); 15% of doses were 1 unit, and 45% were 2 units. When adjusted by patient body weight (kg), the median dose was 7.3 mL/kg (interquartile range, 5.5‐12.0). The median pretransfusion international normalized ratio (INR) was 1.9 (25%‐75% interquartile range, 1.6‐2.6). A total of 22.5% of plasma transfusions were given to patients with an INR of less than 1.6 and 48.5% for an INR of 2.0 or more. The median posttransfusion INR was 1.6 (interquartile range, 1.4‐2.0). Only 42% of plasma transfusions resulted in a posttransfusion INR of less than 1.6. Correction of INR increased as the plasma dose increased from 1 to 4 units (p < 0.001). There was no difference in the INR response to different types of plasma. The most common issue locations were general ward (38%) and intensive care unit (ICU; 42%).ConclusionThis large database describing plasma utilization in the United States provides evidence for both inadequate dosing and unnecessary transfusion. Measures to improve plasma transfusion practice and clinical trials should be directed at patients on medical and surgical wards and in the ICU where plasma is most commonly used.