Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Mapping prostate cancer (CaP) recurrence after prostatectomy with c-11 choline PET/CT and 3T pelvic MRI in the contemporary era.
255 Background: The purpose of this study was to identify site-specific recurrence patterns for patients (pts) with biochemical recurrence (BCR) after prostatectomy (RP) using C-11 Choline PET/CT (C11Ch) and 3T pelvic MRI with endorectal coil (pMRI). Methods: Between 2008 and 2006, 2,466 men underwent C11Ch and pMRI for BCR after RP. From this cohort, we identified 261 pts who received no adjuvant or salvage therapy (androgen deprivation or radiation). Suspected radiographic relapse was confirmed by biopsy (46%) or progression/response to treatment in concordance with subsequent rise/decline in PSA (54%). Results: Of the 261 men evaluated, 202 (75%) had positive pMRI, C11Ch or both. Seventy nine (39%), 105 (52%) and 18 (9%) pts had high, intermediate, and low risk CaP, respectively at RP. Median PSA at the time of positive scan was 2.3 ng/mL, with a median time from BCR to radiographic disease identification of 15 months. Of these 202 men, 67 (33%) harbored prostate fossa recurrence only, 44 (22%) had a combination of local and metastatic disease and 91 (45%) had metastatic disease without local recurrence. Forty (20%) pts had pelvic nodal recurrence only and 18 (9%) had perirectal nodal involvement. Median PSA for pts with local only recurrence, distant metastases only, and local + distant disease was 2.3, 2.7 and 2.2 ng/mL, respectively, with a median interval from BCR to positive scan of 16.7, 7.9 and 11 months. Imaging revealed that 33% to 66% of our cohort would have all sites of disease treated by salvage RT depending on the extent of the treatment field Conclusions: C11Ch and pMRI were used to identify recurrence patterns in pts with BCR after RP only. At median PSA of 2.3 ng/ml, our study demonstrates a low rate of local-only recurrence, higher than anticipated frequency of metastatic recurrence with peak frequency within the pelvic lymph nodes, and substantial perirectal recurrences. Despite the high rates of distant recurrences, 2/3 of our cohort had their disease limited to the pelvis and could be potential candidates for local therapies, including salvage radiation.
Contemporary Mapping of Post-Prostatectomy Prostate Cancer Relapse with
11
C-Choline Positron Emission Tomography and Multiparametric Magnetic Resonance Imaging
AbstractPatient‐centered emergency diagnostic imaging relies on efficient communication and multispecialty care coordination to ensure optimal imaging utilization. The construct of the emergency diagnostic imaging care coordination cycle with three main phases (pretest, test, and posttest) provides a useful framework to evaluate care coordination in patient‐centered emergency diagnostic imaging. This article summarizes findings reached during the patient‐centered outcomes session of the 2015 Academic Emergency Medicine consensus conference “Diagnostic Imaging in the Emergency Department: A Research Agenda to Optimize Utilization.” The primary objective was to develop a research agenda focused on 1) defining component parts of the emergency diagnostic imaging care coordination process, 2) identifying gaps in communication that affect emergency diagnostic imaging, and 3) defining optimal methods of communication and multidisciplinary care coordination that ensure patient‐centered emergency diagnostic imaging. Prioritized research questions provided the framework to define a research agenda for multidisciplinary care coordination in emergency diagnostic imaging.
Detection of Local Recurrence of Prostate Cancer After Radical Prostatectomy Using Endorectal Coil MRI at 3 T: Addition of DWI and Dynamic Contrast Enhancement to T2-Weighted MRI