Back to Authors

Killu, Ammar M.

https://orcid.org/0000-0002-5525-1806

Mayo Clinic

Mayo Clinic

Citations 94

Abstract 17403: Prognositic Significance of T peak - T end Interval in Transthyretin Cardiac Amyloidosis
Sugrue, Alan , Killu, Ammar M, Hai, JoJo, Joppa, Stehpanie, Lin, Grace, Grogan, Martha, Brady, Peter, Killu, Ammar M. , Grogan, Martha , Dispenzieri, Angela

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.17403 Get It

Introduction: The T peak - T end interval (Tpe) is a measure of transmural dispersion of repolarisation with prolongation of this interval linked to an increased risk of ventricular arrhythmias and sudden death. Patients with cardiac amyloid experience a high rate of sudden cardiac death. Objective: To determine the prognostic utility of the Tpeak-Tend interval in patients with transthyretin (TTR) cardiac amyloidosis. Methods: Of the 240 patients who underwent evaluation for TTR amyloidosis at our tertiary referral center from 1966 to 2010, 39 met inclusion criteria (65 excluded for AF, 66 BBB/Paced Rhythm, 25 CAD, 21 other). Inclusion criteria were presence of histological diagnosis of TTR amyloid and confirmed cardiac involvement by echocardiogram or biopsy and absence of atrial fibrillation (AF) or bundle branch block/paced rhythm on the index surface ECG, or history of coronary heart disease (CAD). Tpe was measured in leads V3 and V5. Cox proportional hazards model were used to estimate hazard ratios (HR) and 95% confidence intervals (CI). Kaplan-Meier curves were used to estimate overall survival and differences between curves were estimated using log rank. Primary endpoints were death or heart transplantation. Results: Of the 39 patients, 85% were male, and 69% were mTTR. Mean age 66.4 ± 13.9 years. Mean follow up period of 4.2 ± 3.2 years, 25 died and 5 received heart transplants. Median survival was 3.8 years, with 5 year survival 34%. On univariate analysis, Tpe in lead V3 was predictive of adverse outcome, HR per 10msec, 1.195 (1.051-1.370). Further multivariate analysis, in a model accounting for age, gender, Lead V3 Tpe was independently associated with survival, HR per 10msec, 1.207, (1.094-1.411, p=0.009). Conclusions: The Tpe interval in Lead V3 at diagnosis is a novel, noninvasive independent predictor of survival in transthyretin cardiac amyloidosis patients in sinus rhythm.
Abstract 14833: National Trends in Complications and 30-day Re-hospitalization After Lead Removal/extraction: Analysis From a Cohort Of 42,878 Patients
Mulpuru, Siva K. , Sangaralingham, Lindsey R. , Mawangi, Raphael, Deshmukh, Abhishek , Shah, Nilay D. , Killu, Ammar M. , Cha, Yong‐Mei , Friedman, Paul A. , Noseworthy, Peter A. , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14833 Get It

Introduction: As the US population ages and indications for cardiac device implantation expand, there is a concomitant increase in patients undergoing lead removal/extraction (LR/E).. We sought to examine trends in outcomes and complications associated with LR/E. Methods: We conducted a retrospective analysis using data from a large U.S. commercial insurance database (privately insured and Medicare Advantage patients) identifying all patients undergoing LR/E between 2004 and 2013 with at least one year continuous medical plan enrollment prior to LR/E (to identify baseline comorbidities). Using ICD9 codes and CPT codes, major complications (hemorrhage requiring transfusion, vascular injury, pericardial complications, respiratory complications, cerebrovascular complications, and requirement for cardiac surgery) associated with LR/E and 30-day readmission rates were evaluated. Results: Among 42,878 patients who underwent LR/E (median age of 62 ( 54, 72) years, 70% male); approximately 1 in 40 experienced a major adverse event (2.4%) during the study period. Respiratory complications were the most common complication and 311 patients required cardiac surgery. 30-day readmission occurred in 11.1% of the total population. The most common reasons for readmission were heart failure exacerbation (18.7%) and device related complications (13.2%). Conclusion: The observed complication rates after LE/R in clinical practice are similar to those seen in recent clinical trials and have been relatively stable over the past 10 years.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation
Killu, Ammar M. , Sugrue, Alan , Hodge, David O. , Munger, Thomas M. , Mulpuru, Siva K. , Packer, Douglas L. , Friedman, Paul A. , Al‐Hijji, Mohammed , McLeod, Christopher J. , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112 Get It

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.
Abstract 10903: Extraction Outcomes in Patients With Congenital Heart Disease
Fender, Erin A. , Killu, Ammar M. , Hodge, David O. , Cannon, Bryan C. , Friedman, Paul A. , Broberg, Craig S. , Cha, Yong‐Mei , McLeod, Christopher J. , Henrikson, Charles A.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.10903 Get It

Introduction: Patients with congenital heart disease (CHD) frequently require implantable cardiac devices. Device infection or malfunction may necessitate lead extraction. Extraction may be challenging due to long lead dwell times, anatomic abnormalities, and prior cardiac surgery. Little is known about extraction outcomes in the CHD population. Methods and Results: This retrospective study included 41 CHD patients and 82 age and gender matched controls that underwent lead extractions at two centers between 2001-2014. Only patients with leads older than 12 months were included. There were 79 leads in CHD patients and 150 in controls. Patients with CHD had a mean age of 39±17 years at extraction and on average their leads had been implanted for 81±84 months, this was not significantly different from the control group. Eighty eight percent of CHD patients had 1 or more cardiac surgeries as compared to only 22% of controls (p<0.001). The number of abandoned leads was also significantly different with 16 abandoned leads in the CHD group and 3 in controls (p<0.001). There was no statistically significant difference in extraction techniques between the groups. Complete extraction was achieved in 94% of patients in both groups. There were no CHD group complications. Control group complications included 3 SVC lacerations requiring sternotomy (one was fatal), and 1 ventricular perforations with tamponade requiring sternotomy. None of these patients had a history of cardiac surgery. The average age of leads in patients with a complication was 15.3 years which was older than the mean lead age seen in the CHD and control populations which was 6.75 and 4.6 years respectively. Conclusions: Lead extraction can be safely performed in patients with CHD. Despite anatomic abnormalities and previous cardiac surgery, the outcome of lead extraction in patients with CHD is comparable to controls. Prior cardiac surgery may lower the risk for extraction complications.
Characteristics and Outcomes of Ventricular Tachycardia and Premature Ventricular Contractions Ablation in Patients with Prior Mitral Valve Surgery
Khalil, Fouad , Madhavan, Malini , Badawy, Mohammed, Kapa, Suraj , Mulpuru, Siva K. , Siontis, Konstantinos C. , DeSimone, Christopher V. , Deshmukh, Abhishek , Cha, Young-mei, Friedman, Paul A. , Munger, Thomas M. , Killu, Ammar M. , Khalil, Fouad , Kapa, Suraj , DeSimone, Christopher V , Toya, Takumi , Badawy, Mohammed, Asirvatham, Samuel J.

No container title available | July 2, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162524921.19356960/v1 Get It

Background: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following MVS is limited.) CA can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. Objective: To investigate the characteristics, safety, and outcomes of radiofrequency catheter ablation (CA) in patients with prior mitral valve surgery (MVS) and ventricular arrhythmias (VA). Methods: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013- December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. Results: In our cohort of 31 patients (77% men, mean age 62.3±10.8 years, left ventricular ejection fraction 39.2±13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in 1patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Clinical VA substrates involved the peri-mitral area in 6 patients with VT and 5 patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. Conclusion: CA of VAs can be performed safely and effectively in patients with MVS
Sinus rhythm heart rate increase after atrial fibrillation ablation is associated with lower risk of arrhythmia recurrence
Killu, Ammar M. , Witt, Chance M. , Sugrue, Alan , Vaidya, Vaibhav R. , Monahan, Kristi H. , Lenz, Charles J., Yogeswaran, Vidhushei , Sun, Philip Y. , Hodge, David O. , Friedman, Paul A. , Packer, Douglas L. , Asirvatham, Samuel J. , Sugrue, Alan M, Vaidya, Vaibhav , Barnes, Stephanie, Friedman, Paul A , Asirvatham, Samuel J , Sun, Philip , Barnes, Stephanie

Pacing and Clinical Electrophysiology | February 17, 2021 | Volume: 44 | Issue: 4 | Pages: 651-656

10.1111/pace.14197 Get It

AbstractBackgroundPulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI.MethodsPatients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined.ResultsA total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre‐ablation and 76 ± 13 bpm post‐ablation (27% ± 24% increase, p < .001). The ability of relative HR change post‐ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41–1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome.ConclusionRelative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.
Catheter ablation of premature ventricular contractions originating from periprosthetic aortic valve regions
Han, Jie , Lee, Justin Z. , Padmanabhan, Deepak , Naksuk, Niyada , Asirvatham, Samuel J. , Munger, Thomas M. , Killu, Ammar M. , Madhavan, Malini , Xiao, Pei-Lin, Zheng, Liangrong , Cha, Yong‐Mei , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | December 11, 2020 | Volume: 32 | Issue: 2 | Pages: 400-408

10.1111/jce.14836 Get It

AbstractBackgroundLittle is known about the ablation outcomes of premature ventricular contractions (PVCs) that originate from the periprosthetic aortic valve (PPAV) regions of patients with aortic valve replacement (AVR).Methods and ResultsOur study had 11 patients who underwent catheter ablation for PVCs arising from the PPAV regions (bioprosthetic aortic valve, n = 5; mechanical aortic valve, n = 6). The PVC characteristics, procedure characteristics, and efficacy of ablation were compared with the control group (n = 33). At baseline, the PPAV group had a lower left ventricular ejection fraction (mean [SD], 41% [12%] vs. 51% [8%]; p = .002). The rate of acute ablation success was 90.9% in the PPAV group. Ablation sites were identified above the left coronary cusp (LCC) and right coronary cusp commissure (LRCC) in one PVC, below the prosthetic valve in eight PVCs (four below LCC and four below LRCC), and within the distal coronary sinus in two PVCs. The mean procedure time, fluoroscopy time, and radiation in the PPAV group were all significantly greater than those in the control group (all p < .05). However, the number of radiofrequency ablation energy deliveries was not different. The PPAV group had a long‐term success rate compared with the control group (72.7% vs. 87.9%, p = .48) and an increase of left ventricular ejection fraction from 43% to 49% after successful PVC ablation at follow‐up (p < .001). Echocardiography showed no significant change in valve regurgitation after ablation. No new atrioventricular block occurred.ConclusionPVCs arising from PPAV regions can be successfully ablated in patients with prior AVR, without damaging the prosthetic aortic valve and atrioventricular conduction.
Abstract 16741: A Comparison of High versus Conventional Power Radiofrequency Catheter Ablation for Pulmonary Vein Isolation: A Systematic Review and Meta-Analysis
Amin, Mustapha, Nayfeh, Tarek , Nanaa, Ahmad , Saadi, Samer , Killu, Ammar M. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Nayfeh, Tarek , Saadi, Samer , Kapa, Suraj , DeSimone, Christopher V.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.16741 Get It

Objectives: We sought to evaluate the procedural safety and outcomes of high power (HP) versus conventional power (CP) radiofrequency (RF) ablation during pulmonary vein isolation (PVI). Methods: A systematic search was used via MEDLINE, EMBASE, and Cochrane databases between 01/1998 and 05/2020 for studies comparing the safety and efficacy between HP and CP during RF ablation for PVI using contact-force catheters (ThermocoolSmartTouch or TactiCath). The search terms used were “AF” AND “catheter ablation” OR “radiofrequency ablation”. Results: From eight comparative observational studies, we developed a cohort of 992 patients (478 in the HP and 514 in the CP group). The median maximum energy output used in the HP group was 50W vs 35W in the CP group. There was a statistically significant difference noted in acute pulmonary vein reconnection (APVR) in the HP group compared to the CP groups at16% vs 32.6%, respectively (RR: 0.53, 95% CI: 0.33 - 0.86, P = 0.01). Freedom from arrhythmia at 12 months follow-up was also significant and found to be 87.8% of cases in the HP group versus75.2% of cases in the CP group (RR: 0.46, 95%CI: 0.32 - 0.65, P <0.01). The mean RF ablation time was 20.1 minutes in the HP group vs 39.6 minutes in the CP group (P <0.01). The mean total procedural time was 103.5 minutes in the HP group compared to 135 minutes in the CP group (P <0.01). Two patients in the CP group experienced severe adverse events (1 cardiac tamponade and 1 myocardial infarction). No serious AEs were found in the HP group. Non-serious AEs (groin complications, pericardial effusion, and phrenic nerve injury) were reported in 0.35% and 0.51% of cases in the HP and CP group, respectively. Conclusion: This study suggests that HP PVI ablation can be associated with better ablation outcomes by reducing the rate of acute and late PV reconnection and atrial arrhythmia recurrence, with similar safety profiles, and shorter procedural times. These findings merit evaluation in a randomized controlled trial.
A novel technique—Prophylactic septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement (RADIO‐TMVR)
Killu, Ammar M. , Siontis, Konstantinos C. , Sabbagh, Abdallah El , Eleid, Mackram F. , Rihal, Charanjit S. , Asirvatham, Samuel J. , Rihal, Charanjit, Asirvatham, Samuel J , Guerrero, Mayra , Alkhouli, Mohamad , Rihal, Charanjit S.

Journal of Cardiovascular Electrophysiology | August 21, 2020 | Volume: 31 | Issue: 11 | Pages: 3048-3055

10.1111/jce.14720 Get It

AbstractTranscatheter mitral valve replacement (TMVR) with off‐label use of aortic balloon‐expandable transcatheter heart valves has emerged as a therapeutic option in high‐surgical risk patients with severe mitral annular calcification. Left ventricular outflow tract (LVOT) obstruction post valve deployment is a major limitation. We describe a case of septal reduction therapy using radiofrequency ablation (RFA) when established methods of septal reduction were either ineffective or not feasible. RFA permitted successful enlargement of the LVOT area and subsequent TMVR.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.