Vanderbilt Center for Arrhythmia Research and Therapeutics, Division of Clinical Pharmacology (R.U., K.K., L.R.V., D.W.M., A.S., Y.W., L.C., M.C.L., A.M.G., B.C.K., D.M.R.), Department of Medicine, Vanderbilt University Medical Center, Nashville, TN.
Citations 3
Multiplexed Assays of Variant Effect and Automated Patch Clamping Improve
KCNH2
-LQTS Variant Classification and Cardiac Event Risk Stratification
BACKGROUND: Long QT syndrome is a lethal arrhythmia syndrome, frequently caused by rare loss-of-function variants in the potassium channel encoded by KCNH2 . Variant classification is difficult, often because of lack of functional data. Moreover, variant-based risk stratification is also complicated by heterogenous clinical data and incomplete penetrance. Here we sought to test whether variant-specific information, primarily from high-throughput functional assays, could improve both classification and cardiac event risk stratification in a large, harmonized cohort of KCNH2 missense variant heterozygotes. METHODS: We quantified cell-surface trafficking of 18 796 variants in KCNH2 using a multiplexed assay of variant effect (MAVE). We recorded KCNH2 current density for 533 variants by automated patch clamping. We calibrated the strength of evidence of MAVE data according to ClinGen guidelines. We deeply phenotyped 1458 patients with KCNH2 missense variants, including QTc, cardiac event history, and mortality. We correlated variant functional data and Bayesian long QT syndrome penetrance estimates with cohort phenotypes and assessed hazard ratios for cardiac events. RESULTS: Variant MAVE trafficking scores and automated patch clamping peak tail currents were highly correlated (Spearman rank-order ρ=0.69; n=433). The MAVE data were found to provide up to pathogenic very strong evidence for severe loss-of-function variants. In the cohort, both functional assays and Bayesian long QT syndrome penetrance estimates were significantly predictive of cardiac events when independently modeled with patient sex and corrected QT interval (QTc); however, MAVE data became nonsignificant when peak tail current and penetrance estimates were also available. The area under the receiver operator characteristic curve for 20-year event outcomes based on patient-specific sex and QTc (area under the curve, 0.80 [0.76–0.83]) was improved with prospectively available penetrance scores conditioned on MAVE (area under the curve, 0.86 [0.83–0.89]) or attainable automated patch clamping peak tail current data (area under the curve, 0.84 [0.81–0.88]). CONCLUSIONS: High-throughput KCNH2 variant MAVE data meaningfully contribute to variant classification at scale, whereas long QT syndrome penetrance estimates and automated patch clamping peak tail current measurements meaningfully contribute to risk stratification of cardiac events in patients with heterozygous KCNH2 missense variants.
Arrhythmia Variant Associations and Reclassifications in the eMERGE-III Sequencing Study
Background: Sequencing Mendelian arrhythmia genes in individuals without an indication for arrhythmia genetic testing can identify carriers of pathogenic or likely pathogenic (P/LP) variants. However, the extent to which these variants are associated with clinically meaningful phenotypes before or after return of variant results is unclear. In addition, the majority of discovered variants are currently classified as variants of uncertain significance, limiting clinical actionability. Methods: The eMERGE-III study (Electronic Medical Records and Genomics Phase III) is a multicenter prospective cohort that included 21 846 participants without previous indication for cardiac genetic testing. Participants were sequenced for 109 Mendelian disease genes, including 10 linked to arrhythmia syndromes. Variant carriers were assessed with electronic health record–derived phenotypes and follow-up clinical examination. Selected variants of uncertain significance (n=50) were characterized in vitro with automated electrophysiology experiments in HEK293 cells. Results: As previously reported, 3.0% of participants had P/LP variants in the 109 genes. Herein, we report 120 participants (0.6%) with P/LP arrhythmia variants. Compared with noncarriers, arrhythmia P/LP carriers had a significantly higher burden of arrhythmia phenotypes in their electronic health records. Fifty-four participants had variant results returned. Nineteen of these 54 participants had inherited arrhythmia syndrome diagnoses (primarily long-QT syndrome), and 12 of these 19 diagnoses were made only after variant results were returned (0.05%). After in vitro functional evaluation of 50 variants of uncertain significance, we reclassified 11 variants: 3 to likely benign and 8 to P/LP. Conclusions: Genome sequencing in a large population without indication for arrhythmia genetic testing identified phenotype-positive carriers of variants in congenital arrhythmia syndrome disease genes. As the genomes of large numbers of people are sequenced, the disease risk from rare variants in arrhythmia genes can be assessed by integrating genomic screening, electronic health record phenotypes, and in vitro functional studies. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier; NCT03394859.
Implantable cardioverter-defibrillators in previously undiagnosed patients with catecholaminergic polymorphic ventricular tachycardia resuscitated from sudden cardiac arrest
Abstract Aims In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), implantable cardioverter-defibrillator (ICD) shocks are sometimes ineffective and may even trigger fatal electrical storms. We assessed the efficacy and complications of ICDs placed in patients with CPVT who presented with a sentinel event of sudden cardiac arrest (SCA) while undiagnosed and therefore untreated. Methods and results We analysed 136 patients who presented with SCA and in whom CPVT was diagnosed subsequently, leading to the initiation of guideline-directed therapy, including β-blockers, flecainide, and/or left cardiac sympathetic denervation. An ICD was implanted in 79 patients (58.1%). The primary outcome of the study was sudden cardiac death (SCD). The secondary outcomes were composite outcomes of SCD, SCA, appropriate ICD shocks, and syncope. After a median follow-up of 4.8 years, SCD had occurred in three patients (3.8%) with an ICD and none of the patients without an ICD (P = 0.1). SCD, SCA, or appropriate ICD shocks occurred in 37 patients (46.8%) with an ICD and 9 patients (15.8%) without an ICD (P < 0.0001). Inappropriate ICD shocks occurred in 19 patients (24.7%) and other device-related complications in 22 patients (28.9%). Conclusion In previously undiagnosed patients with CPVT who presented with SCA, an ICD was not associated with improved survival. Instead, the ICD was associated with both a high rate of appropriate ICD shocks and inappropriate ICD shocks along with other device-related complications. Strict adherence to guideline-directed therapy without an ICD may provide adequate protection in these patients without all the potential disadvantages of an ICD.