Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes
Basu, Ananda , Dube, Simmi , Veettil, Sona, Slama, Michael , Kudva, Yogish C. , Peyser, Thomas A. , Carter, Rickey E. , Basu, Rita , Cobelli, Claudio , Carter, Rickey E

Journal of Diabetes Science and Technology | October 11, 2014 | Volume: 9 | Issue: 1 | Pages: 63-68

10.1177/1932296814554797 Get It

Background and Objective: The premise of effective closed-loop insulin therapy for type 1 diabetes (T1D) relies on the accuracy of continuous interstitial fluid glucose sensing that represents the crucial afferent arm of such a system. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. The purpose of current studies was to determine the physiological time lag of glucose transport from the vascular to the abdominal subcutaneous interstitial space in T1D. Method: Four microdialysis catheters were inserted into the abdominal subcutaneous space in 6 T1D subjects under overnight fasted conditions. Plasma glucose was maintained at 113.7 ± 6.3 mg/dl using a continuous intravenous insulin infusion. After sequential intravenous bolus administrations of glucose isotopes, timed plasma and interstitial fluid samples were collected chronologically and analyzed for tracer enrichments. Results: We observed a median (range) time lag of tracer appearance (time to detection) into the interstitial space after intravenous bolus of 6.8 (4.8-9.8) minutes, with all participants having detectable values by 9.8 minutes. Conclusions: We conclude that in the overnight fasted state in T1D adults, the delay of glucose appearance from the vascular to the interstitial space is less than 10 minutes, thereby implying that this minimal physiological time lag should not be a major impediment to the development of an effective closed-loop control system for T1D.
Assessing Statistical Competencies in Clinical and Translational Science Education: One Size Does Not Fit All
Oster, Robert A. , Lindsell, Christopher J. , Mazumdar, Madhu , Thurston, Sally W. , Carter, Rickey E. , Pollock, B. B. , Cucchiara, Andrew J. , Kopras, Elizabeth J. , Jovanovic, Borko, Pollock, Brad H. , Welty, Leah J. , Rahbar, Mohammad H. , Enders, Felicity , Carter, Rickey E

Clinical and Translational Science | September 12, 2014 | Volume: 8 | Issue: 1 | Pages: 32-42

10.1111/cts.12204 Get It

Effects of delayed gastric emptying on postprandial glucose kinetics, insulin sensitivity, and β-cell function
Hinshaw, Ling , Schiavon, Michele , Mallad, Ashwini , Man, Chiara Dalla , Basu, Rita , Bharucha, Adil E. , Carter, Rickey E. , Basu, Ananda , Kudva, Yogish C. , Cobelli, Claudio , Dalla Man, Chiara , Carter, Rickey E , Schiavon, Michele

American Journal of Physiology-Endocrinology and Metabolism | July 30, 2014 | Volume: 307 | Issue: 6 | Pages: E494-E502

10.1152/ajpendo.00199.2014 Get It

Controlling meal-related glucose excursions continues to be a therapeutic challenge in diabetes mellitus. Mechanistic reasons for this need to be understood better to develop appropriate therapies. To investigate delayed gastric emptying effects on postprandial glucose turnover, insulin sensitivity, and β-cell responsivity and function, as a feasibility study prior to studying patients with type 1 diabetes, we used the triple tracer technique C-peptide and oral minimal model approach in healthy subjects. A single dose of 30 μg of pramlintide administered at the start of a mixed meal was used to delay gastric emptying rates. With delayed gastric emptying rates, peak rate of meal glucose appearance was delayed, and rate of endogenous glucose production (EGP) was lower. C-peptide and oral minimal models enabled the assessments of β-cell function, insulin sensitivity, and β-cell responsivity simultaneously. Delayed gastric emptying induced by pramlintide improved total insulin sensitivity and decreased total β-cell responsivity. However, β-cell function as measured by total disposition index did not change. The improved whole body insulin sensitivity coupled with lower rate of appearance of EGP with delayed gastric emptying provides experimental proof of the importance of evaluating pramlintide in artificial endocrine pancreas approaches to reduce postprandial blood glucose variability in patients with type 1 diabetes.
Closed-Loop Artificial Pancreas Systems: Physiological Input to Enhance Next-Generation Devices
Kudva, Yogish C. , Carter, Rickey E. , Basu, Rita , Basu, Ananda , Cobelli, Claudio , Carter, Rickey E

Diabetes Care | April 22, 2014 | Volume: 37 | Issue: 5 | Pages: 1184-1190

10.2337/dc13-2066 Get It

To provide an understanding of both the preclinical and clinical aspects of closed-loop artificial pancreas systems, we provide a discussion of this topic as part of this two-part Bench to Clinic narrative. Here, the Bench narrative provides an in-depth understanding of insulin-glucose-glucagon physiology in conditions that mimic the free-living situation to the extent possible in type 1 diabetes that will help refine and improve future closed-loop system algorithms. In the Clinic narrative, Doyle and colleagues compare and evaluate technology used in current closed-loop studies to gain further momentum toward outpatient trials and eventual approval for widespread use.
Proficiency of nerve conduction using standard methods and reference values (cl. NPhys Trial 4)
Litchy, William J. , Albers, James W., Wolfe, James, Bolton, Charles F., WALSH, NANCY, Klein, Christopher J. , Zafft, Andrew J., Russell, James W. , Zwirlein, Melanie, Overland, Carol J., Davies, Jenny L., Carter, Rickey E. , Dyck, P. James B. , Investigators, the CI. Nphys Trial 4, Tesfaye, Solomon , Investigators, the CI. Nphys Trial 4, Klein, Christopher J , Carter, Rickey E

Muscle & Nerve | March 19, 2014 | Volume: 50 | Issue: 6 | Pages: 900-908

10.1002/mus.24243 Get It

ABSTRACTIntroductionThe Cl. NPhys Trial 3 showed that attributes of nerve conduction (NC) were without significant intraobserver differences, although there were significant interobserver differences. Methods: Trial 4 tested whether use of written instructions and pretrial agreement on techniques and use of standard reference values, diagnostic percentile values, or broader categorization of abnormality could reduce significant interobserver disagreement and improve agreement among clinical neurophysiologists. Results: The Trial 4 modifications markedly decreased, but did not eliminate, significant interobserver differences of measured attributes of NC. Use of standard reference values and defined percentile values of abnormality decreased interobserver disagreement and improved agreement of judgment of abnormality among evaluators. Therefore, the same clinical neurophysiologist should perform repeat NCs of therapeutic trial patients. Conclusions: Differences in interobserver judgment of abnormality decrease with use of common standard reference values and a defined percentile level of abnormality, providing a rationale for their use in therapeutic trials and medical practice. Muscle Nerve 50: 900–908, 2014
Outcomes of Community-Dwelling Adults without Diabetes Mellitus Who Require Ambulance Services for Hypoglycemia
Parsaik, Ajay K. , Carter, Rickey E. , Dong, Ming , Basu, Ananda , Kudva, Yogish C. , Myers, Lucas A. , Carter, Rickey E

Journal of Diabetes Science and Technology | January 10, 2014 | Volume: 6 | Issue: 5 | Pages: 1107-1113

10.1177/193229681200600515 Get It

Objective: We evaluate the prevalence, etiology, and outcomes of hypoglycemia requiring emergency medical services (EMS) in patients without diabetes mellitus (non-DM). Methods: We reviewed medical records of all ambulance calls for non-DM with blood glucose <70 mg/dl in Olmsted County, Minnesota, between January 1, 2003, and December 31, 2009. Results: A total of 131 patients (age 51 ± 19 years; 54 % females) made 142 EMS calls, while 10 patients made repeated calls. Causes of hypoglycemia were critical illness (42; 32%), alcohol and polysubstance use (36; 27.5 %), insulinoma/ bariatric surgery (10; 8%), restricted oral intake (7; 5%), and multiple factors (3; 27.5 %). Patients with alcohol and polysubstance abuse were younger ( p = .002). A total of 54 patients had additional hypoglycemia predisposing comorbidities/factors [adrenal insufficiency (2), end-stage renal disease (11) and chronic liver disease (7), beta blockers use (34), and pentamidine use (1)]. Repeated calls and emergency room transportation were similar, but hospitalization varied across the etiologies, with the lowest proportion in the multiple-factor-related hypoglycemia group ( p = .01). Duration of follow-up was 1.28 (interquartile range 0.13–2.70) years. A total of 38 patients died, and age-adjusted mortality varied across different etiologies ( p < .001), with highest among critically ill. Cancer caused the highest number of deaths (7/38; 18%), while 1 death was due to hypoglycemia. Conclusions: There were multiple etiologies for hypoglycemic episodes in community-dwelling non-DM that required EMS. Critical illness, multifactorial causes, and alcohol/polysubstance abuse were common causes. Hospitalization and mortality were higher with critical illnesses.
Population-Based Study of Severe Hypoglycemia Requiring Emergency Medical Service Assistance Reveals Unique Findings
Parsaik, Ajay K. , Carter, Rickey E. , Pattan, Vishwanath , Kumar, Hamit, Smith, Steven A., Russi, Christopher S. , Levine, James A. , Basu, Ananda , Kudva, Yogish C. , Myers, Lucas A. , Carter, Rickey E

Journal of Diabetes Science and Technology | January 10, 2014 | Volume: 6 | Issue: 1 | Pages: 65-73

10.1177/193229681200600109 Get It

Objective: The objective is to report a contemporary population-based estimate of hypoglycemia requiring emergency medical services (EMS), its burden on medical resources, and its associated mortality in patients with or without diabetes mellitus (DM, non-DM), which will enable development of prospective strategies that will capture hypoglycemia promptly and provide an integrated approach for prevention of such episodes. Methods: We retrieved all ambulance calls activated for hypoglycemia in Olmsted County, Minnesota, between January 1, 2003 and December 31, 2009. Results: A total of 1473 calls were made by 914 people (DM 8%, non-DM 16%, unknown DM status 3%). Mean age was 60 ± 16 years with 49% being female. A higher percentage of calls were made by DM patients (87%) with proportionally fewer calls coming from non-DM patients (11%) (chi-square test, p < .001), and the remaining 2% calls by people with unknown DM status. Emergency room transportation and hospitalization were significantly higher in non-DM patients compared to DM patients ( p < .001) and type 2 diabetes mellitus compared to type 1 diabetes mellitus ( p < .001). Sulphonylureas alone or in combination with insulin varied during the study period ( p = .01). The change in incidence of EMS for hypoglycemia was tracked during this period. However, causality has not been established. Death occurred in 240 people, 1.2 (interquartile range 0.2–2.7) years after their first event. After adjusting for age, mortality was higher in non-DM patients compared with DM patients ( p < .001) but was not different between the two types of DM. Conclusions: The population burden of EMS requiring hypoglycemia is high in both DM and non-DM patients, and imposes significant burden on medical resources. It is associated with long-term mortality.
Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans
Basu, Ananda , Dube, Simmi , Slama, Michael , Errazuriz, Isabel, Amezcua, Jose Carlos, Kudva, Yogish C. , Peyser, Thomas A. , Carter, Rickey E. , Basu, Rita , Cobelli, Claudio , Carter, Rickey E

Diabetes | September 5, 2013 | Volume: 62 | Issue: 12 | Pages: 4083-4087

10.2337/db13-1132 Get It

The accuracy of continuous interstitial fluid (ISF) glucose sensing is an essential component of current and emerging open- and closed-loop systems for type 1 diabetes. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. We performed the first direct measurement of this phenomenon to our knowledge in eight healthy subjects under an overnight fasted condition. Microdialysis catheters were inserted into the abdominal subcutaneous space. After intravenous bolus administrations of glucose tracers, timed samples of plasma and ISF were collected sequentially and analyzed for tracer enrichments. After accounting for catheter dead space and assay noise, the mean time lag of tracer appearance in the interstitial space was 5.3–6.2 min. We conclude that in the overnight fasted state in healthy adults, the physiological delay of glucose transport from the vascular to the interstitial space is 5–6 min. Physiological delay between blood glucose and ISF glucose, therefore, should not be an obstacle to sensor accuracy in overnight or fasting-state closed-loop systems of insulin delivery or open-loop therapy assessment for type 1 diabetes.
Comparison of Physical Activity Sensors and Heart Rate Monitoring for Real-Time Activity Detection in Type 1 Diabetes and Control Subjects
Manohar, Chinmay U., O’Keeffe, Derek T. , Hinshaw, Ling , Lingineni, Ravi K., McCrady-Spitzer, Shelly , Levine, James A. , Carter, Rickey E. , Basu, Ananda , Kudva, Yogish C. , Manohar, Chinmay, Carter, Rickey E

Diabetes Technology & Therapeutics | August 12, 2013 | Volume: 15 | Issue: 9 | Pages: 751-757

10.1089/dia.2013.0044 Get It

Background: Currently, patients with type 1 diabetes decide on the amount of insulin to administer based on several factors, including current plasma glucose value, expected meal input, and physical activity (PA). One future therapeutic modality for patients with type 1 diabetes is the artificial endocrine pancreas (AEP). Incorporation of PA could enhance the efficacy of AEP significantly. We compared the main technologies used for PA quantitation. Subjects and Methods: Data were collected during inpatient studies involving healthy control subjects and type 1 diabetes. We report PA quantified from accelerometers (acceleration units [AU]) and heart rate (HR) monitors during a standardized activity protocol performed after a dinner meal at 7 p.m. from nine control subjects (four were males, 37.4±12.7 years old, body mass index of 24.8±3.8 kg/m 2 , and fasting plasma glucose of 4.71±0.63 mmol/L) and eight with type 1 diabetes (six were males, 45.2±13.4 years old, body mass index of 25.1±2.9 kg/m 2 , and fasting plasma glucose of 8.44±2.31 mmol/L). Results: The patient-to-patient variability was considerably less when examining AU compared with HR monitors. Furthermore, the exercise bouts and rest periods were more evident from the data streams when AUs were used to quantify activity. Unlike the AU, the HR measurements provided little insight for active and rest stages, and HR data required patient-specific standardizations to discern any meaningful pattern in the data. Conclusions: Our results indicated that AU provides a reliable signal in response to PA, including low-intensity activity. Correlation of this signal with continuous glucose monitoring data would be the next step before exploring inclusion as input for AEP control.
Multicenter trial of the proficiency of smart quantitative sensation tests
Dyck, P. James B. , Argyros, Barbara, Russell, James W. , Gahnstrom, Linde E., Nalepa, Susan, Albers, James W., Lodermeier, Karen A., Zafft, Andrew J., Klein, Christopher J. , Litchy, William J. , Davies, Jenny L., Carter, Rickey E. , Melton, L. Joseph , (Appendix), members of the Cl versus NPhys Trials, Tesfaye, Solomon , (Appendix), members of the Cl versus NPhys Trials, Klein, Christopher J , Carter, Rickey E

Muscle & Nerve | August 8, 2013 | Volume: 49 | Issue: 5 | Pages: 645-653

10.1002/mus.23982 Get It

ABSTRACTIntroduction: We assessed proficiency (accuracy and intra‐ and intertest reproducibility) of smart quantitative sensation tests (smart QSTs) in subjects without and with diabetic sensorimotor polyneuropathy (DSPN). Methods: Technologists from 3 medical centers using different but identical QSTs independently assessed 6 modalities of sensation of the foot (or leg) twice in patients without (n = 6) and with (n = 6) DSPN using smart computer assisted QSTs. Results: Low rates of test abnormalities were observed in health and high rates in DSPN. Very high intraclass correlations were obtained between continuous measures of QSTs and neuropathy signs, symptoms, or nerve conductions (NCs). No significant intra‐ or intertest differences were observed. Conclusions: These results provide proof of concept that smart QSTs provide accurate assessment of sensation loss without intra‐ or intertest differences useful for multicenter trials. Smart technology makes possible efficient testing of body surface area sensation loss in symmetric length‐dependent sensorimotor polyneuropathies. Muscle Nerve 49: 645–653, 2014