ABSTRACT Introduction: The Amyotrophic Lateral Sclerosis (ALS)‐Specific Quality of Life instrument and its revised version (ALSSQOL and ALSSQOL‐R) have strong psychometric properties, and have demonstrated research and clinical utility. In this study we aimed to develop a short form (ALSSQOL‐SF) suitable for limited clinic time and patient stamina. Methods: The ALSSQOL‐SF was created using Item Response Theory and confirmatory factor analysis on 389 patients. A cross‐validation sample of 162 patients assessed convergent, divergent, and construct validity of the ALSSQOL‐SF compared with psychosocial and physical functioning measures. Results: The ALSSQOL‐SF consisted of 20 items. Compared with the ALSSQOL‐R, optimal precision was retained, and completion time was reduced from 15–25 minutes to 2–4 minutes. Psychometric properties for the ALSSQOL‐SF and its subscales were strong. Discussion: The ALSSQOL‐SF is a disease‐specific global QOL instrument that has a short administration time suitable for clinical use, and can provide clinically useful, valid information about persons with ALS. Muscle Nerve 58: 646–654, 2018
Proficiency of nerve conduction using standard methods and reference values (cl. NPhys Trial 4)
ABSTRACTIntroductionThe Cl. NPhys Trial 3 showed that attributes of nerve conduction (NC) were without significant intraobserver differences, although there were significant interobserver differences. Methods: Trial 4 tested whether use of written instructions and pretrial agreement on techniques and use of standard reference values, diagnostic percentile values, or broader categorization of abnormality could reduce significant interobserver disagreement and improve agreement among clinical neurophysiologists. Results: The Trial 4 modifications markedly decreased, but did not eliminate, significant interobserver differences of measured attributes of NC. Use of standard reference values and defined percentile values of abnormality decreased interobserver disagreement and improved agreement of judgment of abnormality among evaluators. Therefore, the same clinical neurophysiologist should perform repeat NCs of therapeutic trial patients. Conclusions: Differences in interobserver judgment of abnormality decrease with use of common standard reference values and a defined percentile level of abnormality, providing a rationale for their use in therapeutic trials and medical practice. Muscle Nerve 50: 900–908, 2014
Multicenter trial of the proficiency of smart quantitative sensation tests
ABSTRACTIntroduction: We assessed proficiency (accuracy and intra‐ and intertest reproducibility) of smart quantitative sensation tests (smart QSTs) in subjects without and with diabetic sensorimotor polyneuropathy (DSPN). Methods: Technologists from 3 medical centers using different but identical QSTs independently assessed 6 modalities of sensation of the foot (or leg) twice in patients without (n = 6) and with (n = 6) DSPN using smart computer assisted QSTs. Results: Low rates of test abnormalities were observed in health and high rates in DSPN. Very high intraclass correlations were obtained between continuous measures of QSTs and neuropathy signs, symptoms, or nerve conductions (NCs). No significant intra‐ or intertest differences were observed. Conclusions: These results provide proof of concept that smart QSTs provide accurate assessment of sensation loss without intra‐ or intertest differences useful for multicenter trials. Smart technology makes possible efficient testing of body surface area sensation loss in symmetric length‐dependent sensorimotor polyneuropathies. Muscle Nerve 49: 645–653, 2014
A trial of proficiency of nerve conduction: Greater standardization still needed
ABSTRACTIntroductionThe aim of this study was to test the proficiency (accuracy among evaluators) of measured attributes of nerve conduction (NC).MethodsExpert clinical neurophysiologists, without instruction or consensus development, from 4 different medical centers, independently assessed 8 attributes of NC in 24 patients with diabetes mellitus (DM) on consecutive days.ResultsNo significant intraobserver differences between days 1 and 2 were found, but significant interobserver differences were seen. Use of standard reference values did not correct for these observed differences.ConclusionsInterobserver variability was attributed to differences in performance of NC. It was of sufficient magnitude that it is of concern for the conduct of therapeutic trials. To deal with interrater variability in therapeutic trials, the same electromyographers should perform all NC assessments of individual patients or, preferably, NC procedures should be more standardized. A further trial is needed to test whether such standardization would eliminate interobserver variability. Muscle Nerve 48: 369–374, 2013
Diagnostic accuracy and certainty from sequential evaluations in peripheral neuropathy