Back to Authors

Cotofana, Sebastian

0000-0001-7210-6566

Mayo Clinic

Department of Clinical Anatomy, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.

Citations 44

Reliability of 3‐dimensional surface imaging of the face using a whole‐body surface scanner
Xu, Ya , Frank, Konstantin , Kohler, Lukas , Ehrl, Denis , Alfertshofer, Michael , Giunta, Riccardo Enzo , Moellhoff, Nicholas , Cotofana, Sebastian , Koban, Konstantin Christoph , Giunta, Riccardo E. , Cotofana, Sebastian , Alfertshofer, Michael , Giunta, Riccardo Enzo , Moellhoff, Nicholas

Journal of Cosmetic Dermatology | November 3, 2021 | Volume: 21 | Issue: 4 | Pages: 1464-1470

10.1111/jocd.14555 Get It

AbstractObjectiveTo the knowledge of the authors, no data about the reproducibility and accuracy of 3‐dimensional surface imaging of the face using a whole‐body scanner are available. Thus, the objective of this investigation was to assess the reproducibility of facial scans acquired using a whole‐body imaging device.Material and MethodsThis investigation investigated 220 3‐D scans of a total of 22 healthy volunteers (with a mean age of 29.36 years). Two consecutive 3‐D images using a Vectra WB360 of the volunteers were obtained utilizing a whole‐body imaging device. Predefined distances in the face were performed in each scan and compared. Furthermore, surface deviation between two consecutively captured scans was assessed.ResultsThe distance with the smallest statistical significance was found to be at the nose with p = 0.998, while the biggest statistical significance was found in the midface with p = 0.658. The area with the biggest surface deviation between the superimposed scans was the neck with a root mean square (RMS) of 1.62 ± 1.71, and the area with the smallest surface deviation was the forehead with a RMS of 0.17 ± 0.05.ConclusionThe whole‐body imaging device investigated in this study can be utilized to capture the face and provides enough accuracy to compare scans. Even though not directly investigated, it can be hypothesized that the error caused by repositioning the patient between a baseline and a follow‐up scan will not be too big to consider measurements performed with the whole‐body imaging device as impractical.
Soft tissue filler augmentation of the orbicularis retaining ligament to improve the lid‐cheek junction
Bernardini, Francesco P. , Alfertshofer, Michael , Frank, Konstantin , Davidović, Kristina , Voropai, Daria , Valli, Andrea Maria Francesco, Cotofana, Sebastian , Alfertshofer, Michael , Frank, Konstantin , Cotofana, Sebastian , Casabona, Gabriela , Moellhoff, Nicholas , Gotkin, Robert H. , Valli, Andrea

Journal of Cosmetic Dermatology | October 22, 2021 | Volume: 20 | Issue: 11 | Pages: 3446-3453

10.1111/jocd.14495 Get It

AbstractBackgroundThe orientation of facial ligaments changes with increasing age due to the loss of bony support. Soft tissue filler injections placed in close proximity to facial ligaments can alter their orientation to help achieve an improved and younger aesthetic appearance.ObjectiveTo assess the anatomic and aesthetic effects of a standardized injection with soft tissue filler placed directly inferior to the orbicularis retaining ligament in the infraorbital region.MethodsA total of 163 patients with signs of infraorbital aging were treated with a standardized soft tissue filler injection into and in close proximity to the orbicularis retaining ligament (ORL). 2D frontal images of the infraorbital region were rated by eleven blinded and independent raters with regards to the aesthetic appearance of the infraorbital region before and after the standardized injection treatment.ResultsThe aesthetic appearance of the entire infraorbital region (lid‐cheek junction) was rated before and after the treatment. The severity of the tear trough (medial aspect of the infraorbital region) as well as the hollowing of the lateral aspect of the infraorbital region also was rated before and after the treatment. Aesthetic improvement was statistically significant when evaluated by the blinded raters, the treating physician, and the patients. All the results were “very much improved” compared to baseline.ConclusionThe effectiveness of this injection technique is thought to be due to the strategic placement of soft tissue filler that helps to reposition facial ligaments that have changed their orientation during the aging process.
Real-Time Ultrasound Imaging of the Tear Trough: Lessons Learned From Functional Anatomy
Calomeni, Mariana, Alfertshofer, Michael , Frank, Konstantin , Dennison, Rebekah, Bravo, Bruna Felix, Velthuis, Peter J. , Cotofana, Sebastian , Bihun, Rebekah , Elias, Mariana Calomeni , Alfertshofer, Michael , Bravo, Bruna , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas , Schelke, Leonie , Green, Jeremy B. , Bihun, Rebekah J.

Aesthetic Surgery Journal | October 6, 2021 | Volume: 42 | Issue: 5 | Pages: 518-526

10.1093/asj/sjab351 Get It

AbstractBackgroundThe tear trough is one of the most challenging facial regions for soft-tissue filler injections. A thorough understanding of the underlying facial, muscular, and vascular anatomy is crucial to perform safe and effective tear trough injectable treatments.ObjectivesThe authors sought to evaluate the location and function of the angular vein in the tear trough in 3 different facial expressions: repose, smiling, and max. orbicularis oculi contraction.MethodsTwenty study participants with a mean age of 48.3 years and mean BMI of 24.5 kg/m2 were investigated via functional ultrasound imaging. The diameter of the angular vein and the velocity and direction of venous blood flow were analyzed in repose, smiling, and during max. orbicularis oculi contraction.ResultsThe angular vein was identified in 100% of the cases to travel inside the orbicularis oculi muscle (intra-muscular course) within the tear trough, whereas the angular artery was not identified in this location. The distance between the angular vein and the inferior orbital rim was (lateral to medial): 4.6 mm, 4.5 mm, 3.9 mm, and 3.8 mm. The caudally directed blood flow was in repose 10.2 cm/s and was 7.3 cm/s at max. orbicularis oculi muscle contraction; however, no blood flow was detectable during smiling.ConclusionsThe diameter and the venous blood flow of the angular vein varied between the 3 tested facial expressions. Based on these anatomical findings, the deep injection approach to the tear trough is recommended due to the intramuscular course of the angular vein.
Safety and efficacy of microneedling technology in the treatment of acne scars
Alfertshofer, Michael , Kaye, Kai , Frank, Konstantin , Mercado‐Perez, Arnaldo , Hargiss, J. Blade , Cotofana, Sebastian , Frank, Konstantin , Mercado-Perez, Arnaldo, Hargiss, John Blade , Cotofana, Sebastian , Alfertshofer, Michael , Casabona, Gabriela , Green, Jeremy B.

Journal of Cosmetic Dermatology | October 2, 2021 | Volume: 20 | Issue: 11 | Pages: 3482-3491

10.1111/jocd.14502 Get It

AbstractBackgroundCurrent options for the reduction of acne scarring (eg, ablative laser resurfacing) are associated with considerable side effects and limitations in terms of patient population. Percutaneous collagen induction via microneedling poses an alternative treatment method due to its low rates of reported adverse events and side effects.ObjectiveTo assess the safety and effectiveness of microneedling treatments in reducing acne scars.MethodsA total of 22 patients (18 females and 4 males) with a mean age of 38 ± 7.6 years were assessed regarding the appearance of facial acne scarring. Acne scars were assessed via the Acne Scar Assessment Scale (ASAS) and the Goodman and Baron acne scar grading scale before and after two/three treatments. Additionally, the post‐interventional development of side reactions, adverse events, and patient‐reported outcomes (eg, pain/discomfort, skin redness) was reported.ResultsCompared to baseline, the mean ASAS value was improved statistically significantly on average by 1.41 and 1.46 after the second treatment as assessed by the independent raters and the patients, respectively. In patients who received a total of three treatments, a statistically significant mean improvement in ASAS value of 1.35 and 1.66 compared to baseline was assessed by the independent raters and patients, respectively. No unexpected adverse events were reported. The severity and rate of side reactions decreased over the course of this study.ConclusionMicroneedling treatments can pose a safe and effective option in the reduction of acne scarring. In this study, microneedling helped achieving a significant reduction of acne scars while showing high patient safety.
Filler Anatomy
Cotofana, Sebastian , Cotofana, Sebastian , Velthuis, Peter J. , Schelke, Leonie

Aesthetic Surgery Journal | October 1, 2021 | Volume: 42 | Issue: 1 | Pages: NP89-NP90

10.1093/asj/sjab348 Get It

Longevity and subject‐reported satisfaction after minimally invasive jawline contouring
Müller, Daniel S. , Prinz, Valentina, Sulovsky, Monika , Cajkovsky, Mia, Cotofana, Sebastian , Frank, Konstantin , Müller, Daniel , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas

Journal of Cosmetic Dermatology | September 18, 2021 | Volume: 21 | Issue: 1 | Pages: 199-206

10.1111/jocd.14410 Get It

AbstractBackgroundMinimally invasive treatments as soft tissue filler injections can enhance the appearance of the jawline. This prospective, single‐center study investigated aesthetic outcome, patient satisfaction, adverse events, and volume changes after jawline contouring using standardized reporting scales and objectifiable 3D surface analysis.MethodsA total of 30 patients (1 male and 29 females, mean age: 57.2 (±8.7) years) were investigated. Patients underwent jawline augmentation using a highly cross‐linked hyaluronic acid–based soft tissue filler. Three‐dimensional surface imaging was performed after 2 weeks, and 3, 6, 9, and 12 months. Furthermore, the aesthetic results and the occurrence of complications were investigated after two weeks, and 3, 6, 9, and 12 months.ResultsThe surface‐volume coefficient (SVC) had an average of 1.10 ± 0.2 after 14 days, 0.95 ± 0.1 after 3 months, 0.83 ± 0.1 after 6 months, 0.74 ± 0.1 after 9 months, and 0.63 ± 0.1 after 12 months. A significant correlation was revealed between time of measurement and measured SVC with rp = −0.761, p < 0.001. Multivariate analysis revealed a significant difference between the measured SVC and the different time points of measurement with p < 0.001. The data revealed strong aesthetic improvement with results most often reported as “very much improved” according to the 5‐point GAIS after 3, 6, and 9 months, both by the investigator and by the patients. A 12‐month follow‐up analysis showed “much improved” results in a majority of cases.ConclusionThe result of this investigation showed that jawline enhancement using minimally invasive soft tissue filler injections produces durable, safe results that are generally rated as very satisfying from a patient's and investigator's perspective over a time period of 12 months.
The mobility of the superficial and deep midfacial fat compartments: An ultrasound‐based investigation
Velthuis, Peter J. , Lowry, Natalia, Rohrich, Rod J., Swift, Arthur, Frank, Konstantin , Cotofana, Sebastian , Frank, Konstantin , Frank, Konstantin , Dumbrava, Mihai , Cotofana, Sebastian , Schelke, Leonie , Gotkin, Robert H. , Moellhoff, Nicholas , Dumbravă, Mihai

Journal of Cosmetic Dermatology | August 8, 2021 | Volume: 20 | Issue: 12 | Pages: 3849-3856

10.1111/jocd.14374 Get It

AbstractBackgroundUnderstanding the mobility of the midface and the separate contributions of the superficial and deep fat compartments is essential for natural esthetic outcomes following soft tissue filler or fat grafting procedures. A study was designed that used ultrasound imaging to demonstrate in vivo visualization and quantification of distances and movements in the midface.MethodsA total of 48 midfaces of 24 healthy Caucasian volunteers, all naïve of esthetic procedures, (22 females; 46.85 (9.8) years; 22.83 (3.1) kg/m2) were scanned using 18 MHz ultrasound imaging. Distances between bony landmarks (inferior orbital rim, infraorbital foramen) were used as markers to measure the cranial movement of the superficial (superficial nasolabial and superficial medial cheek fat compartment) and the deep (deep pyriform space, deep medial check fat compartment, deep lateral cheek fat compartment) midfacial fat compartments between resting and smiling facial position.ResultsThe superficial midfacial fat compartment moved, on average, 3.7 mm (p < 0.001) cranially, whereas the deep midfacial fat compartments moved, on average, 0.1 mm (p > 0.05) during smiling. No gender differences in mobility were identified (p > 0.05).ConclusionThe results obtained are in line with previous cadaveric investigations and revealed, in a highly statistically significant fashion, that the superficial midfacial fat compartments move in cranial direction whereas the deep fat compartment did not display similar positional changes. These results help to guide facial injectable treatments and to understand why, in the midface, a deep supraperiosteal approach should be favored when augmenting the deep midfacial fat compartments.
The Layered Anatomy of the Nose: An Ultrasound-Based Investigation
Alfertshofer, Michael , Frank, Konstantin , Ehrl, Denis , Freytag, David L., Beleznay, Katie, Swift, Arthur, Cotofana, Sebastian , Velthuis, Peter J. , Alfertshofer, Michael , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas , Gotkin, Robert H. , Mardini, Samir

Aesthetic Surgery Journal | August 7, 2021 | Volume: 42 | Issue: 4 | Pages: 349-357

10.1093/asj/sjab310 Get It

AbstractBackgroundAn increasing number of soft tissue filler procedures in the nasal region has been reported. Concomitant with demand, the number of complications has risen due to the difficulty in administering filler in a region where soft tissue layering is complex.ObjectivesThe authors sought to describe the layered soft tissue arrangement of the nose as it relates to the underlying arterial vasculature and to define safer zones for nasal filler enhancement.MethodsA total of 60 (28 males and 32 females) study participants were investigated with respect to their layered anatomy in the midline of the nose utilizing ultrasound imaging. The presence and extent of the layered arrangement was examined as well as the depth of the arterial vasculature.ResultsIn the mid-nasal dorsum, a 5-layer arrangement was observed in 100% (n = 60) of all investigated cases, whereas it was found to be absent in the nasal radix and tip. The 5-layer arrangement showed an average extent of 26.7% to 67.5% in relation to nasal length. The nasal arteries coursed superficially in 91.7% of all cases in the nasal radix, in 80% in the mid-nasal dorsum, and in 98.3% in the nasal tip.ConclusionsSoft tissue filler administration in the nose carries the highest risk for irreversible vision loss compared with any other facial region. The safety of soft tissue filler rhinoplasty procedures is enhanced by knowledge of the layered anatomy of the nose, the location and depth of the major nasal vasculature, and employment of maneuvers to decrease the risk of blindness.
The Impact of Breast Symmetry on Eye Movement and Gaze Pattern: An Eye-Tracking Investigation
Kandelhardt, Chiara, Ehrl, Denis , Kohler, Lukas , Koban, Konstantin Christoph , Giunta, Riccardo E. , Guertler, Anne , Cotofana, Sebastian , Frank, Konstantin , Velthuis, Peter J. , Koban, Konstantin , Cotofana, Sebastian , Moellhoff, Nicholas , Mardini, Samir , Frank, Konstantin

Aesthetic Surgery Journal | July 17, 2021 | Volume: 41 | Issue: 11 | Pages: NP1512-NP1518

10.1093/asj/sjab285 Get It

Abstract Background The objective assessment of beauty remains challenging despite ongoing research efforts. A new method of objectively determining the aesthetic appeal of body features by analyzing gaze patterns and eye movements has recently been investigated. Objectives The objective of this study was to assess, by means of objective eye-tracking technology, differences in the gaze patterns of observers presented with standardized 3-dimensional images showing different degrees of breast asymmetry. Methods A total of 83 Caucasian study participants with a mean age of 38.60 (19.8) years were presented with 5 images depicting varying degrees of breast asymmetry. In addition to the assessment of eye movements, participants were asked to rate the aesthetic appeal and the asymmetry of the breasts on a 5-point Likert scale. Results Overall, the data showed that participants’ rating of the breasts’ aesthetic appeal was inversely related to the level of asymmetry. The mean [standard deviation] time until fixation was shortest for the image depicting the greatest breast asymmetry (50 cc) at 0.77 [0.7] seconds (P &lt; 0.001). In addition, the mammary region was also viewed longest in this image at 3.76 [0.5] seconds (P &lt; 0.001). A volume difference of 35 cc between breasts deflected the observers’ gaze significantly toward the larger of the asymmetric breasts (P &lt; 0.001). Conclusions Surgeons should focus on achieving symmetric breast volume (ie, differences &lt;35 cc between breasts) to avoid noticeable asymmetry with regard to breast size.
After the Temporal Lifting Technique—What comes next?
Hernandez, Claudia A, Schneider, Carolina, Gold, Michael H. , Muniz, Mariana, Alfertshofer, Michael , Frank, Konstantin , Cotofana, Sebastian , Alfertshofer, Michael , Frank, Konstantin , Cotofana, Sebastian , Gold, Michael H , Green, Jeremy B.

Journal of Cosmetic Dermatology | May 22, 2021 | Volume: 20 | Issue: 12 | Pages: 3857-3862

10.1111/jocd.14247 Get It

AbstractBackgroundThe temporal lifting technique can provide lateral facial lifting when administering hyaluronic acid (HA)‐based soft tissue fillers into the subdermal plane of the temple. However, the central facial oval is not influenced by this technique.ObjectivesTo identify the safety and esthetic effectiveness of additional midfacial injection points (in addition to the temporal lifting technique) that can volumize the medial midface, lift the lateral face, and increase jawline contouring when included into a full‐face injection algorithm.MethodsThe patient records of nine consecutive patients (all females) with a mean age of 35.0 (8.4) years and a mean body mass index of 21.7 (2.4) kg/m2 were retrospectively analyzed after a full‐face injection algorithm was performed using HA‐based fillers. The additional injection points target the supraperiosteal plane of the medial zygomatic arch, the lateral infraorbital region, and the pyriform fossa using both needles and cannula.ResultsNo adverse events were observed during the 6‐month retrospective observational period. The volume of the medial midface increased, the volume of the lateral midface decreased, and the contour of the jawline improved; all effects reached a highly statistically significant level with p < 0.001.ConclusionDespite each individual injection is currently performed on a daily clinical basis the evaluated injection algorithm following the temporal lifting technique shows some evidence that it is safe and esthetically effective. Future studies will need to confirm the results presented herein in a larger sample and with objective outcome measures to guide safe and effective esthetic outcomes.