Back to Authors

Schelke, Leonie

0000-0002-5512-1956

Mayo Clinic

Erasmus MC

Citations 9

Deliberations of the Safety Task Force: Risk factors and treatment of adverse events associated with aesthetic injectables
Nikolis, Andreas , Cohen, Joel L. , Enright, Kaitlyn M. , Avelar, Luiz Eduardo Toledo , Beleznay, Katie, Biesman, Brian S. , Cartier, Hugues , Cotofana, Sebastian , Fabi, Sabrina G. , Parada, Meire Brasil, Rzany, Berthold, Wang, Hang, Bromée, Torun, Weiner, Steven C., Avelar, Luiz , Goodman, Greg , Schelke, Leonie , Cotofana, Sebastian , Fitzgerald, Rebecca, Lee, Won , Weiner, Steven

Journal of Cosmetic Dermatology | August 20, 2024 | Volume: 23 | Issue: 11 | Pages: 3551-3564

10.1111/jocd.16476 Get It

AbstractBackgroundThe growing popularity of aesthetic procedures involving fillers, biostimulators, and neurotoxins has prompted concerns about patient safety. To address these concerns, a global Safety Task Force (STF) was formed.AimsThe inaugural STF meeting prioritized vascular compromise prevention and management, guiding clinical trial design and materials for future meetings, and collecting data from experts on current safety methods.MethodsThe STF was formed and consisted of 16 experts from nine different countries, with each possessing distinct expertise in various fields related to aesthetic injectables. Current safety data, protocols, knowledge gaps and future research priorities were discussed and voted upon.ResultsThe establishment of a global database for tracking filler‐related AEs was favored by 93% of participants. Discussions revolved around the database's scope, data standardization, and whether non‐medical contributors should be included. Aspiration as a safety technique garnered support from 73% of participants. Approximately 43% of participants incorporate ultrasound in their injections, with divergent opinions on its impact and potential when used as a standard of practice versus in AE management. Most physicians on the task force incorporated cannula use for some of their injections (93%). There were varying perspectives on treatments for vascular adverse events (VAE), the primary causes, and the adoption of new protocols in the field.ConclusionsThe STF meeting underscored the need for a coordinated effort to address complications related to HA fillers, including VAE management and hyaluronidase protocols. Reliable treatment endpoints were evaluated, but improved measurement methods are needed. Future meetings will focus on addressing delayed complications, furthering safety in this field.
Investigating the Anatomic Location of Soft Tissue Fillers in Noninflammatory Nodule Formation: An Ultrasound-Imaging–Based Analysis
Decates, Tom S. , Cartier, Hugues , Schelke, Leonie , Cotofana, Sebastian , Velthuis, Peter J.

Dermatologic Surgery | March 21, 2023 | Volume: 49 | Issue: 6 | Pages: 588-595

10.1097/dss.0000000000003756 Get It

INTRODUCTION Noninflammatory nodules may be persistent to dissolve. To evaluate the possible reasons, a case series of ultrasound images and medical data of patients who were prospectively referred with noninflammatory nodules were evaluated. MATERIALS AND METHODS A total of 27 patients with nodules but without signs of inflammation were included. All cases were assessed with an 18-MHz linear ultrasound device. Exact location of the filler material was noted. Relations with clinical data were analyzed using chi-square tests. RESULTS Early onset of complaints (<2 weeks) was found in 16 patients and late onset (>2 weeks) in 11. All patients had multiple nodules. In all cases, the filler nodule was found to be located inside the fascia. Extension to the subcutaneous tissue was seen in 8 cases and to the deeper planes in 5. In 14 cases, the filler material was completely located inside layers of the fascia, and migration was observed in 5 cases. DISCUSSION Accumulation of filler material in the superficial musculoaponeurotic system or fascia may be an important cause for the occurrence of persistent noninflammatory nodules, either by initial faulty injection technique or by later accumulation through the pathway generated with a needle or cannula. Ultrasound-guided injections are helpful to dissolve the nodule.
Precision in Midfacial Volumization Using Ultrasound-Assisted Cannula Injections
Lowry, Natalia, Rohrich, Rod J., Swift, Arthur, Alfertshofer, Michael , Frank, Konstantin , Alfertshofer, Michael , Schelke, Leonie , Velthuis, Peter J. , Gotkin, Robert H. , Cotofana, Sebastian

Plastic & Reconstructive Surgery | February 2, 2023 | Volume: 152 | Issue: 1 | Pages: 67-74

10.1097/prs.0000000000010131 Get It

Background: Soft-tissue filler injections performed with a cannula are perceived to be less precise because of the length of the instrument and the blunt tip, which can deviate in any direction. Midfacial needle injections are favored despite the increased risk for intraarterial product placement. The objective of this study was to demonstrate that ultrasound-assisted cannula injections of the midface result in precise, safe, and effective volumization procedures. Methods: Midfacial injections with a 22-G cannula were performed in 188 midfaces of 94 healthy volunteers [86 women; age, 53.05 (9.9) years; 23.63 (2.1) kg/m2] under ultrasound-assisted guidance. Precision (ie, administration of product in the same plane as the location of the cannula tip), safety (ie, rate of adverse events), and aesthetic outcome (rated by the patient and the treating physician) were assessed. Results: In 100% of cases, the product was applied into the desired deep midfacial fat compartment, and the product did not migrate into more superficial layers during the injection process or at any follow-up visit. There was a statistically significant (P < 0.001) improvement in midfacial volume loss and the aesthetic outcome was rated as very much improved. No adverse events were reported throughout follow-up. Conclusions: Real-time imaging allows for visual feedback during cannula advancement and injection procedures in the midface and can help practitioners achieve safer aesthetic outcomes. It is hoped that practitioners decide to use a cannula more frequently for midfacial volumization, given the results presented in this article. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
Precision of Soft-Tissue Filler Injections: An Ultrasound-Based Verification Study
Calomeni, Mariana, Bravo, Bruna S F, Velthuis, Peter J. , Schalet, Grant, Frank, Konstantin , Guertler, Anne , Alfertshofer, Michael , Cotofana, Sebastian , Elias, Mariana Calomeni , Frank, Konstantin , Frank, Konstantin , Alfertshofer, Michael , Cotofana, Sebastian , Schelke, Leonie , Moellhoff, Nicholas

Aesthetic Surgery Journal | October 25, 2022 | Volume: 43 | Issue: 3 | Pages: 353-361

10.1093/asj/sjac272 Get It

Abstract Background Uncontrolled product spread is an important issue to consider in facial filler injections. Lack of precision can result in reduced effectiveness and surface projection, as well as irregularities and product visibility. Objectives The authors sought to assess the precision of soft-tissue filler injections in the face by employing a cannula. Methods This single-center observational study investigated soft-tissue filler distribution utilizing real-time non-invasive ultrasound imaging. Outcome parameters included (1) the tissue plane of product distribution, (2) the extent of horizontal as well as vertical product spread at the injection site, and (3) the product surface area taking into account the multifactorial influence of several independent variables. Participants were followed up to 30 days post-injection. Results A total 100 facial injections were performed in 8 patients (2 males, 6 females) with a mean age of 37.20 (±6.34) years and a mean BMI of 22.21 (±1.39) kg/m.2. The plane of product distribution remained constant in approximately 90% of cases at day 0 (d0), d14, and d30. Mean horizontal product spread was higher compared with vertical spread, and both significantly decreased over all time points (P &lt; .001). Mean product surface area was 22.51 ± 16.34 mm2 at d0, 15.97 ± 11.28 mm2 at d14, and 12.9 ± 9.15 mm2 at d30. Analysis employing generalized linear models revealed that injection volume and injection depth significantly influenced product surface area. Conclusions Injection of soft-tissue filler employing a cannula allows precise application of the product within the intended tissue plane. Precision can be improved by injecting less product into deeper tissue layers. Level of Evidence: 5
Two New Phenomena Associated With Filler Injection
Cotofana, Sebastian , Velthuis, Peter J. , Cotofana, Sebastian , Frank, Konstantin , Schelke, Leonie

Aesthetic Surgery Journal | October 21, 2022 | Volume: 43 | Issue: 2 | Pages: NP134-NP135

10.1093/asj/sjac271 Get It

Real-Time Ultrasound Imaging of the Tear Trough: Lessons Learned From Functional Anatomy
Calomeni, Mariana, Alfertshofer, Michael , Frank, Konstantin , Dennison, Rebekah, Bravo, Bruna Felix, Velthuis, Peter J. , Cotofana, Sebastian , Bihun, Rebekah , Elias, Mariana Calomeni , Alfertshofer, Michael , Bravo, Bruna , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas , Schelke, Leonie , Green, Jeremy B. , Bihun, Rebekah J.

Aesthetic Surgery Journal | October 6, 2021 | Volume: 42 | Issue: 5 | Pages: 518-526

10.1093/asj/sjab351 Get It

AbstractBackgroundThe tear trough is one of the most challenging facial regions for soft-tissue filler injections. A thorough understanding of the underlying facial, muscular, and vascular anatomy is crucial to perform safe and effective tear trough injectable treatments.ObjectivesThe authors sought to evaluate the location and function of the angular vein in the tear trough in 3 different facial expressions: repose, smiling, and max. orbicularis oculi contraction.MethodsTwenty study participants with a mean age of 48.3 years and mean BMI of 24.5 kg/m2 were investigated via functional ultrasound imaging. The diameter of the angular vein and the velocity and direction of venous blood flow were analyzed in repose, smiling, and during max. orbicularis oculi contraction.ResultsThe angular vein was identified in 100% of the cases to travel inside the orbicularis oculi muscle (intra-muscular course) within the tear trough, whereas the angular artery was not identified in this location. The distance between the angular vein and the inferior orbital rim was (lateral to medial): 4.6 mm, 4.5 mm, 3.9 mm, and 3.8 mm. The caudally directed blood flow was in repose 10.2 cm/s and was 7.3 cm/s at max. orbicularis oculi muscle contraction; however, no blood flow was detectable during smiling.ConclusionsThe diameter and the venous blood flow of the angular vein varied between the 3 tested facial expressions. Based on these anatomical findings, the deep injection approach to the tear trough is recommended due to the intramuscular course of the angular vein.
Filler Anatomy
Cotofana, Sebastian , Cotofana, Sebastian , Velthuis, Peter J. , Schelke, Leonie

Aesthetic Surgery Journal | October 1, 2021 | Volume: 42 | Issue: 1 | Pages: NP89-NP90

10.1093/asj/sjab348 Get It

The mobility of the superficial and deep midfacial fat compartments: An ultrasound‐based investigation
Velthuis, Peter J. , Lowry, Natalia, Rohrich, Rod J., Swift, Arthur, Frank, Konstantin , Cotofana, Sebastian , Frank, Konstantin , Frank, Konstantin , Dumbrava, Mihai , Cotofana, Sebastian , Schelke, Leonie , Gotkin, Robert H. , Moellhoff, Nicholas , Dumbravă, Mihai

Journal of Cosmetic Dermatology | August 8, 2021 | Volume: 20 | Issue: 12 | Pages: 3849-3856

10.1111/jocd.14374 Get It

AbstractBackgroundUnderstanding the mobility of the midface and the separate contributions of the superficial and deep fat compartments is essential for natural esthetic outcomes following soft tissue filler or fat grafting procedures. A study was designed that used ultrasound imaging to demonstrate in vivo visualization and quantification of distances and movements in the midface.MethodsA total of 48 midfaces of 24 healthy Caucasian volunteers, all naïve of esthetic procedures, (22 females; 46.85 (9.8) years; 22.83 (3.1) kg/m2) were scanned using 18 MHz ultrasound imaging. Distances between bony landmarks (inferior orbital rim, infraorbital foramen) were used as markers to measure the cranial movement of the superficial (superficial nasolabial and superficial medial cheek fat compartment) and the deep (deep pyriform space, deep medial check fat compartment, deep lateral cheek fat compartment) midfacial fat compartments between resting and smiling facial position.ResultsThe superficial midfacial fat compartment moved, on average, 3.7 mm (p < 0.001) cranially, whereas the deep midfacial fat compartments moved, on average, 0.1 mm (p > 0.05) during smiling. No gender differences in mobility were identified (p > 0.05).ConclusionThe results obtained are in line with previous cadaveric investigations and revealed, in a highly statistically significant fashion, that the superficial midfacial fat compartments move in cranial direction whereas the deep fat compartment did not display similar positional changes. These results help to guide facial injectable treatments and to understand why, in the midface, a deep supraperiosteal approach should be favored when augmenting the deep midfacial fat compartments.
The Change of Plane of the Supratrochlear and Supraorbital Arteries in the Forehead—An Ultrasound-Based Investigation
Cotofana, Sebastian , Velthuis, Peter J. , Alfertshofer, Michael , Frank, Konstantin , Bertucci, Vince , Beleznay, Kate, Swift, Arthur, Gavril, Diana L., Lachman, Nirusha , Cotofana, Sebastian , Alfertshofer, Michael , Frank, Konstantin , Schelke, Leonie

Aesthetic Surgery Journal | March 2, 2021 | Volume: 41 | Issue: 11 | Pages: NP1589-NP1598

10.1093/asj/sjaa421 Get It

Abstract Background Injecting soft tissue fillers into the deep plane of the forehead carries the risk of injection-related visual compromise due to the specific course of the arterial vasculature. Objectives The aim of this study was to investigate the 2- and 3-dimensional location of the change of plane of the deep branch of the supratrochlear and supraorbital artery, respectively. Methods A total of 50 patients (11 males and 39 females; mean age, 49.76 [13.8] years, mean body mass index, 22.53 [2.6] kg/m2) were investigated with ultrasound imaging. The total thickness and the distance of the arteries from the skin and bone surface were measured with an 18-MHz broadband compact linear array transducer. Results The deep branch of the supraorbital artery changed plane from deep to superficial to the frontalis muscle at a mean distance of 13 mm (range, 7.0-19.0 mm) in males and at 14 mm (range, 4.0-24.0 mm) in females and for the deep branch of the supratrochlear artery at a mean distance of 14 mm in males and females (range, 10.0-19.0 in males, 4.0-27.0 in females) when measured from the superior orbital rim. Conclusions Based on the ultrasound findings in this study, it seems that the supraperiosteal plane of the upper and lower forehead could be targeted during soft tissue filler injections because the deep branches of both the supraorbital and supratrochlear arteries do not travel within this plane. The superficial plane of the lower forehead, however, should be avoided due to the unpredictability and inconsistent presence of the central and paracentral arteries. Level of Evidence: 4