INTRODUCTION Noninflammatory nodules may be persistent to dissolve. To evaluate the possible reasons, a case series of ultrasound images and medical data of patients who were prospectively referred with noninflammatory nodules were evaluated. MATERIALS AND METHODS A total of 27 patients with nodules but without signs of inflammation were included. All cases were assessed with an 18-MHz linear ultrasound device. Exact location of the filler material was noted. Relations with clinical data were analyzed using chi-square tests. RESULTS Early onset of complaints (<2 weeks) was found in 16 patients and late onset (>2 weeks) in 11. All patients had multiple nodules. In all cases, the filler nodule was found to be located inside the fascia. Extension to the subcutaneous tissue was seen in 8 cases and to the deeper planes in 5. In 14 cases, the filler material was completely located inside layers of the fascia, and migration was observed in 5 cases. DISCUSSION Accumulation of filler material in the superficial musculoaponeurotic system or fascia may be an important cause for the occurrence of persistent noninflammatory nodules, either by initial faulty injection technique or by later accumulation through the pathway generated with a needle or cannula. Ultrasound-guided injections are helpful to dissolve the nodule.
Facial aesthetic minimally invasive procedure: More than just vanity, a social‐psychological approach
AbstractBackgroundDue to the great importance of the face in social interaction, minimally invasive treatments can—besides their ability to rejuvenate and enhance beauty—also change the way facial impressions of a person are perceived. In recent literature, three main character traits (attractiveness, trustworthiness, and competence) and subdomains essential for facial perception were described.ObjectiveTo investigate whether minimally invasive procedures truly influence different character traits when evaluated by independent, objective observers.MethodsPhotographs of n = 34 female faces before and after treatment with injectable fillers and botulinum toxin were rated by 393 individuals without aesthetic background with regards to different character traits on a 7‐point Likert scale. Tests for dimensionality were performed, and composite scores of the impressions underlying each of the three dimensions were created and compared using within‐subjects t tests.ResultsTreatments statistically significantly improved the overarching character trait domains attractiveness, trustworthiness, and competence in posttreatment photographs compared with pretreatment. Posttreatment ratings of the respective subdomains also showed a statistically significant difference compared with pretreatment photographs, with the exception of the subdomain dominance which failed to reach statistical significance.ConclusionImpressions of facial attractiveness, trustworthiness, and competence can be improved by injectables while the naturalness of the face is left intact. An implication is that the improvement of traits highly relevant to social interaction will accommodate the patient's desires for beautification and rejuvenation.
Precision in Midfacial Volumization Using Ultrasound-Assisted Cannula Injections
Background: Soft-tissue filler injections performed with a cannula are perceived to be less precise because of the length of the instrument and the blunt tip, which can deviate in any direction. Midfacial needle injections are favored despite the increased risk for intraarterial product placement. The objective of this study was to demonstrate that ultrasound-assisted cannula injections of the midface result in precise, safe, and effective volumization procedures. Methods: Midfacial injections with a 22-G cannula were performed in 188 midfaces of 94 healthy volunteers [86 women; age, 53.05 (9.9) years; 23.63 (2.1) kg/m2] under ultrasound-assisted guidance. Precision (ie, administration of product in the same plane as the location of the cannula tip), safety (ie, rate of adverse events), and aesthetic outcome (rated by the patient and the treating physician) were assessed. Results: In 100% of cases, the product was applied into the desired deep midfacial fat compartment, and the product did not migrate into more superficial layers during the injection process or at any follow-up visit. There was a statistically significant (P < 0.001) improvement in midfacial volume loss and the aesthetic outcome was rated as very much improved. No adverse events were reported throughout follow-up. Conclusions: Real-time imaging allows for visual feedback during cannula advancement and injection procedures in the midface and can help practitioners achieve safer aesthetic outcomes. It is hoped that practitioners decide to use a cannula more frequently for midfacial volumization, given the results presented in this article. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
Precision of Soft-Tissue Filler Injections: An Ultrasound-Based Verification Study
Abstract Background Uncontrolled product spread is an important issue to consider in facial filler injections. Lack of precision can result in reduced effectiveness and surface projection, as well as irregularities and product visibility. Objectives The authors sought to assess the precision of soft-tissue filler injections in the face by employing a cannula. Methods This single-center observational study investigated soft-tissue filler distribution utilizing real-time non-invasive ultrasound imaging. Outcome parameters included (1) the tissue plane of product distribution, (2) the extent of horizontal as well as vertical product spread at the injection site, and (3) the product surface area taking into account the multifactorial influence of several independent variables. Participants were followed up to 30 days post-injection. Results A total 100 facial injections were performed in 8 patients (2 males, 6 females) with a mean age of 37.20 (±6.34) years and a mean BMI of 22.21 (±1.39) kg/m.2. The plane of product distribution remained constant in approximately 90% of cases at day 0 (d0), d14, and d30. Mean horizontal product spread was higher compared with vertical spread, and both significantly decreased over all time points (P < .001). Mean product surface area was 22.51 ± 16.34 mm2 at d0, 15.97 ± 11.28 mm2 at d14, and 12.9 ± 9.15 mm2 at d30. Analysis employing generalized linear models revealed that injection volume and injection depth significantly influenced product surface area. Conclusions Injection of soft-tissue filler employing a cannula allows precise application of the product within the intended tissue plane. Precision can be improved by injecting less product into deeper tissue layers. Level of Evidence: 5
Two New Phenomena Associated With Filler Injection
Abstract Background Neuromodulators have proven efficacy in reducing facial rhytides and have also been reported to improve jawline contour and the appearance of platysmal bands. Lifting effects of the tail of the eyebrow are expected outcomes when targeting the lateral periorbital region, underscoring the versatility of neuromodulator treatments. Objectives The aim of this study was to analyze the clinical effectiveness of a novel neuromodulator-based injection algorithm with regards to its ability to reposition the middle and lower facial soft tissues. Methods Seventy-five study participants (8 males, 67 females) with a mean [standard deviation] age of 37.5 [8.5] years were injected with neuromodulators in the subdermal plane of the mandibular soft tissues following a standardized algorithm. Live rating of clinical appearance was performed, as well as volume change and skin vector displacement measured by 3-dimensional imaging at baseline, Day 14, and Day 30. Results Three-dimensional volume analysis revealed an increase in midfacial volume by 0.46 mL, and a decrease of the lower facial volume by 0.30 mL compared with baseline. Additionally, an improvement of midfacial fullness (by 0.13) and jawline contour (by 0.44) was reported on clinical rating scales at Day 30 compared with baseline. Conclusions Facial soft tissues can be repositioned during the 30-day follow-up period following a neuromodulator treatment; this was reflected through an increase in midfacial volume as well as through a decrease in lower facial volume. The novel injection algorithm presented can provide a safe and effective option for patients desiring improvement of midfacial fullness and jawline contour with neuromodulator treatment alone. Level of Evidence: 4
Upper Facial Anastomoses Between the External and Internal Carotid Vascular Territories – A 3D Computed Tomographic Investigation
Abstract Background Facial regions with a high risk for causing injection-related visual comprise are dual-supply vascular areas such as the nose, glabella, and forehead. These regions have in common that they receive arterial blood supply both by branches of the internal (ICA) and the external carotid artery (ECA). Objective The authors sought to investigate the anastomotic pathways between ICA and ECA branches in the upper face. Methods Postmortem computed tomographic angiographic scans of n = 38 Chinese non-embalmed hemifaces (25 males, 13 females; mean age, 37.79 [11.8] years; mean BMI, 21.90 [2.3] kg/m2) were conducted. Data analysis relied on the calculation of depth, distances, and pathways of forehead and temporal arteries to investigate the number of anastomotic connections, the connecting branches, and the layer of connection between ICA and ECA territories. Results Between ICA and ECA territories, only 1 connection in 57.9%, 2 connections in 31.6%, 3 connections in 5.3%, and 4 and 5 connections in 2.6% each were identified. A superficial connection was observed in 15.8% whereas in 84.2% the anastomotic connection was identified to be both superficial and deep. Conclusions Adverse events following facial minimally invasive soft-tissue filler injections for aesthetic purposes are not frequent but devastating if they occur. Anatomic knowledge as presented in this study can help to increase awareness of 3-dimensional vascular anastomotic pathways and identify safer injection zones and safer fascial planes. Evidence-based injection techniques should be followed, and safety aspects should be placed over the aesthetic outcome.
Commentary on: Facial Arterial Variations in Asians: A Study on Computed Tomographic Angiography
AbstractBackgroundThe tear trough is one of the most challenging facial regions for soft-tissue filler injections. A thorough understanding of the underlying facial, muscular, and vascular anatomy is crucial to perform safe and effective tear trough injectable treatments.ObjectivesThe authors sought to evaluate the location and function of the angular vein in the tear trough in 3 different facial expressions: repose, smiling, and max. orbicularis oculi contraction.MethodsTwenty study participants with a mean age of 48.3 years and mean BMI of 24.5 kg/m2 were investigated via functional ultrasound imaging. The diameter of the angular vein and the velocity and direction of venous blood flow were analyzed in repose, smiling, and during max. orbicularis oculi contraction.ResultsThe angular vein was identified in 100% of the cases to travel inside the orbicularis oculi muscle (intra-muscular course) within the tear trough, whereas the angular artery was not identified in this location. The distance between the angular vein and the inferior orbital rim was (lateral to medial): 4.6 mm, 4.5 mm, 3.9 mm, and 3.8 mm. The caudally directed blood flow was in repose 10.2 cm/s and was 7.3 cm/s at max. orbicularis oculi muscle contraction; however, no blood flow was detectable during smiling.ConclusionsThe diameter and the venous blood flow of the angular vein varied between the 3 tested facial expressions. Based on these anatomical findings, the deep injection approach to the tear trough is recommended due to the intramuscular course of the angular vein.