2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) | December 9, 2021 | Volume: No volume available | Issue: No issue available | Pages: 2405-2408
Transcutaneous (TSS) and epidural spinal stimulation (ESS) are electrophysiological techniques that have been used to investigate the interactions between exogenous electrical stimuli and spinal sensorimotor networks that integrate descending motor signals with afferent inputs from the periphery during motor tasks such as standing and stepping. Recently, pilot-phase clinical trials using ESS and TSS have demonstrated restoration of motor functions that were previously lost due to spinal cord injury (SCI). However, the spinal network interactions that occur in response to TSS or ESS pulses with spared descending connections across the site of SCI have yet to be characterized. Therefore, we examined the effects of delivering TSS or ESS pulses to the lumbosacral spinal cord in nine individuals with chronic SCI. During low-frequency stimulation, participants were instructed to relax or attempt maximum voluntary contraction to perform full leg flexion while supine. We observed similar lower-extremity neuromusculature activation during TSS and ESS when performed in the same participants while instructed to relax. Interestingly, when participants were instructed to attempt lower-extremity muscle contractions, both TSS- and ESS-evoked motor responses were significantly inhibited across all muscles. Participants with clinically complete SCI tested with ESS and participants with clinically incomplete SCI tested with TSS demonstrated greater ability to modulate evoked responses than participants with motor complete SCI tested with TSS, although this was not statistically significant due to a low number of subjects in each subgroup. These results suggest that descending commands combined with spinal stimulation may increase activity of inhibitory interneuronal circuitry within spinal sensorimotor networks in individuals with SCI, which may be relevant in the context of regaining functional motor outcomes.
Potential impact of epidural stimulation on neurogenic bladder function and the value of urodynamic studies throughout usage
Application and Reliability of Accelerometer-Based Arm Use Intensities in the Free-Living Environment for Manual Wheelchair Users and Able-Bodied Individuals
Arm use in manual wheelchair (MWC) users is characterized by a combination of overuse and a sedentary lifestyle. This study aimed to describe the percentage of daily time MWC users and able-bodied individuals spend in each arm use intensity level utilizing accelerometers. Arm use intensity levels of the upper arms were defined as stationary, low, mid, and high from the signal magnitude area (SMA) of the segment accelerations based on in-lab MWC activities performed by eight MWC users. Accelerometry data were collected in the free-living environments from forty MWC users and 40 sex- and age-matched able-bodied individuals. The SMA intensity levels were applied to the free-living data and the percentage of time spent in each level was calculated. The SMA intensity levels were defined as, stationary: ≤0.67 g, low: 0.671–3.27 g, mid: 3.27–5.87 g, and high: >5.871 g. The dominant arm of both MWC users and able-bodied individuals was stationary for most of the day and less than one percent of the day was spent in high intensity arm activities. Increased MWC user age correlated with increased stationary arm time (R = 0.368, p = 0.019). Five and eight days of data are needed from MWC users and able-bodied individuals, respectively, to achieve reliable representation of their daily arm use intensities.
Case Report: Optimizing Daily Function for People with Below-elbow Limb Deficiency with the SoftHand Pro
Background: Innovation in prosthetic devices for adults with upper limb loss is necessary to meet the demand for effective devices to optimize participation in daily activity. We evaluate the SoftHand Pro (SHP) as a terminal device to determine the application of this biologically-inspired prosthetic hand for use for a person with transradial limb deficiency. Method: This case study describes and measures the first use of the SHP by an individual with transradial limb deficiency in their home environment. This paper reports the features and functionality of the SHP prototype and provides recommendations for changes to further optimize function. Results: The participant found the simple mechanics, durability, and ease of use of the SHP to be beneficial. She praised the SHP’s positive impact on quality of life and suggested areas for optimization. Objective assessments of dexterity and function showed improvements. Conclusion: Using a biologically-inspired myoelectric hand provides an opportunity for intuitively controlled grasp of common large and small objects. The simplicity of use and the lightweight, durable design of the SHP has the potential to provide a positive impact on quality of life, and this case study has provided valuable feedback to further improve the hand and enable larger at-home trials.
Impact of long-term epidural electrical stimulation enabled task-specific training on secondary conditions of chronic paraplegia in two humans
Electrophysiological Guidance of Epidural Electrode Array Implantation over the Human Lumbosacral Spinal Cord to Enable Motor Function after Chronic Paralysis
Epidural electrical stimulation (EES) of the spinal cord has been shown to restore function after spinal cord injury (SCI). Characterization of EES-evoked motor responses has provided a basic understanding of spinal sensorimotor network activity related to EES-enabled motor activity of the lower extremities. However, the use of EES-evoked motor responses to guide EES system implantation over the spinal cord and their relation to post-operative EES-enabled function in humans with chronic paralysis attributed to SCI has yet to be described. Herein, we describe the surgical and intraoperative electrophysiological approach used, followed by initial EES-enabled results observed in 2 human subjects with motor complete paralysis who were enrolled in a clinical trial investigating the use of EES to enable motor functions after SCI. The 16-contact electrode array was initially positioned under fluoroscopic guidance. Then, EES-evoked motor responses were recorded from select leg muscles and displayed in real time to determine electrode array proximity to spinal cord regions associated with motor activity of the lower extremities. Acceptable array positioning was determined based on achievement of selective proximal or distal leg muscle activity, as well as bilateral muscle activation. Motor response latencies were not significantly different between intraoperative recordings and post-operative recordings, indicating that array positioning remained stable. Additionally, EES enabled intentional control of step-like activity in both subjects within the first 5 days of testing. These results suggest that the use of EES-evoked motor responses may guide intraoperative positioning of epidural electrodes to target spinal cord circuitry to enable motor functions after SCI.
Restoration of Articular Geometry Using Current Graft Options for Large Glenoid Bone Defects in Anterior Shoulder Instability
Purpose The purpose of this cadaveric study was to compare standard and modified coracoid transfer procedures, bicortical and tricortical iliac crest autografts, and tibial plafond and glenoid allografts with respect to glenoid surface curvature restoration. Methods Computed tomography scans of 8 cadaveric shoulders were acquired in 9 conditions: (1) intact, (2) 25% width defect, (3) classic Latarjet, (4) modified congruent‐arc Latarjet, (5) tricortical iliac crest inner table, (6) outer table, (7) bicortical iliac crest, (8) distal tibia, and (9) glenoid allograft. Outcome measures included articular surface area, width, depth, axial and coronal radius of curvature, and subchondral articular step‐off, analyzed in bone and soft‐tissue window. Results Reconstruction of the articular surface area was optimal with the glenoid allograft (99.4%), classic Latarjet (97.4%), and iliac crest bicortical graft (93.2%). Depth was best restored by the congruent‐arc Latarjet (101.0%), tibial (98.9%), and glenoid (95.3%) allografts. Axial curvature was closely matched by the glenoid allograft (97.5%), classic Latarjet (108.7%), and iliac bicortical graft (91.2%). Coronal curvature was most accurately restored by the glenoid allograft (102.6%), the tibial allograft (115.0%), and the classic Latarjet (55.9%). The articular step‐off was smallest using the glenoid allograft. Conclusions Overall, glenoid allografts most accurately restored articular geometry. Alternative grafts provided restoration of some parameters but not others. Classic Latarjet performed well in axial and coronal curvature on average but exhibited large variability. Tibial allograft produced the poorest results in axial curvature, despite excellent coronal curvature reconstruction. The congruent‐arc Latarjet did not restore the axial curvature accurately and overcorrected coronal curvature. Graft geometry must be weighed against availability, morbidity, and the role of additional stabilizers. Clinical Relevance Accurate graft morphology may help prevent postoperative osteoarthritis. Grafts differ significantly regarding geometric parameters. The findings of this study will help surgeons select the most appropriate graft for glenoid reconstruction.
Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
The Role of Dynamic (4D) CT in the Detection of Scapholunate Ligament Injury