Back to Authors

Forte, Antonio Jorge

0000-0003-2004-7538

Mayo Clinic

Division of Plastic Surgery, Mayo Clinic, 4500 San Pablo Rd S, Jacksonville, FL 32224, USA.

Citations 188

Respective Roles of Craniosynostosis and Syndromic Influences on Cranial Fossa Development
Lu, Xiaona , Forte, Antonio J. , Wilson, Alexander T. , Park, Kitae Eric , Allam, Omar , Alperovich, Michael , Steinbacher, Derek M., Alonso, Nivaldo , Persing, John A. , Forte, Antonio Jorge

Plastic & Reconstructive Surgery | June 28, 2021 | Volume: 148 | Issue: 1 | Pages: 145-156

10.1097/prs.0000000000008101 Get It

Background: Little is known about the detailed growth of the cranial fossae, even though they provide an important structural connection between the cranial vault and the facial skeleton. This study details the morphologic development of isolated cranial vault synostosis and associated syndromes on cranial fossa development. Methods: A total of 125 computed tomographic scans were included (nonsyndromic bicoronal synostosis, n = 36; Apert syndrome associated with bicoronal synostosis, n = 24; Crouzon syndrome associated with bicoronal synostosis, n = 11; and controls, n = 54). Three-dimensional analyses were produced using Materialise software. Results: The regional anterior and middle cranial fossae volumes of nonsyndromic bicoronal synostosis are characterized by significant increases of 43 percent (p < 0.001) and 60 percent (p < 0.001), respectively, and normal posterior cranial fossa volume. The cranial fossae depths of nonsyndromic bicoronal synostosis were increased, by 37, 42, and 21 percent (all p < 0.001) for anterior, middle, and posterior cranial fossae, respectively, accompanying the shortened cranial fossae lengths. The volume and morphology of all cranial fossae in Apert syndrome nearly paralleled nonsyndromic bicoronal synostosis. However, Crouzon syndrome had reduced depths of cranial fossae, and more restricted fossa volumes than both Apert syndrome and nonsyndromic bicoronal synostosis. Conclusions: Cranial vault suture synostosis is likely to be more influential on cranial fossae development than other associated influences (genetic, morphologic) in Apert and Crouzon syndromes. Isolated Apert syndrome pathogenesis is associated with an elongation of the anterior cranial fossa length in infants, whereas in Crouzon syndrome, there is a tendency to reduce cranial fossa depth, suggesting individual adaptability in cranial fossae development related to vault synostosis.
Wearable electronic devices for chronic pain intensity assessment: A systematic review
Huayllani, María T. , Giardi, Davide , Carter, Rickey E. , Forte, Antonio J. , Ávila, Francisco R. , Boczar, Daniel , Bruce, Charles J. , Forte, Antonio Jorge , Carter, Rickey E , McLeod, Christopher J.

Pain Practice | June 3, 2021 | Volume: 21 | Issue: 8 | Pages: 955-965

10.1111/papr.13047 Get It

AbstractWearable electronic devices are a convenient solution to pain intensity assessment as they can provide continuous monitoring for more precise medication adjustments. However, there is little evidence regarding the use of wearable electronic devices for chronic pain intensity assessment. Our primary objective was to examine the physiologic parameters used by wearable electronic devices for chronic pain intensity assessment. We initially inquired PubMed, CINAHL, and Embase for studies evaluating the use of wearable electronic devices for chronic pain intensity assessment. We updated our inquiry by searching on PubMed, Embase, Scopus, and Google Scholar. English peer‐reviewed studies were included, with no exclusions based on time frame or publication status. Of 348 articles that were identified on the first inquiry, 8 fulfilled the eligibility criteria. Of 179 articles that were identified on the last inquiry, only 1 fulfilled the eligibility criteria. We found articles evaluating wristbands, smartwatches, and belts. Parameters evaluated were psychomotor and sleep patterns, space and time mobility, heart rate variability, and skeletal muscle electrical activity. Most of the studies found significant positive associations between physiological parameters measured by wearable electronic devices and self‐reporting pain scales. Wearable electronic devices reliably reflect physiologic or biometric parameters, providing a physiological correlation for pain. Early stage investigation suggests that the degree of pain intensity can be discerned, which ideally will reduce the bias inherent to existing numeric/verbal scales. Further research on the use of these devices is vital.
Accuracy of Wearable Sensor Technology in Hand Goniometry: A Systematic Review
Ávila, Francisco R. , Carter, Rickey E. , Giardi, Davide , Guliyeva, Günel , Forte, Antonio J. , Bruce, Charles J. , Giardi, Davide , Forte, Antonio Jorge , Carter, Rickey E , Avila, Francisco R , McLeod, Christopher J.

HAND | May 25, 2021 | Volume: 18 | Issue: 2 | Pages: 340-348

10.1177/15589447211014606 Get It

Background Wearable devices and sensor technology provide objective, unbiased range of motion measurements that help health care professionals overcome the hindrances of protractor-based goniometry. This review aims to analyze the accuracy of existing wearable sensor technologies for hand range of motion measurement and identify the most accurate one. Methods We performed a systematic review by searching PubMed, CINAHL, and Embase for studies evaluating wearable sensor technology in hand range of motion assessment. Keywords used for the inquiry were related to wearable devices and hand goniometry. Results Of the 71 studies, 11 met the inclusion criteria. Ten studies evaluated gloves and 1 evaluated a wristband. The most common types of sensors used were bend sensors, followed by inertial sensors, Hall effect sensors, and magnetometers. Most studies compared wearable devices with manual goniometry, achieving optimal accuracy. Although most of the devices reached adequate levels of measurement error, accuracy evaluation in the reviewed studies might be subject to bias owing to the use of poorly reliable measurement techniques for comparison of the devices. Conclusion Gloves using inertial sensors were the most accurate. Future studies should use different comparison techniques, such as infrared camera–based goniometry or virtual motion tracking, to evaluate the performance of wearable devices.
Does Reduction Mammaplasty for Treatment of Macromastia Play a Role in the Functionality and Performance of Female Athletes?
Kaplan, Jamie L. , Forte, Antonio J. , Kaplan, Jamie, Forte, Antonio Jorge

Plastic & Reconstructive Surgery | May 21, 2021 | Volume: 147 | Issue: 6 | Pages: 1084e-1084e

10.1097/prs.0000000000007921 Get It

The Importance of Financial Metrics in Physician Funding and Performance Evaluation
Patrinely, James R. , Walker, Sallie, Glassman, Gabriella E. , Davis, Matthew J. , Khan, Umraz , Drolet, Brian C. , Forte, Antonio J. , Patrinely, J Randall, Walker, Sallie H, Abu-Ghname, Amjed, Perdikis, Galen, Forte, Antonio Jorge , Abu‐Ghname, Amjed , Perdikis, Galen

Plastic & Reconstructive Surgery | April 23, 2021 | Volume: 147 | Issue: 5 | Pages: 1213-1218

10.1097/prs.0000000000007882 Get It

Background: Financial key performance indicators are often used to evaluate performance. Understanding of key performance indicators can be crucial for career advancement and bargaining leverage in resource negotiations. This study aimed to identify the most important key performance indicators used in surgical funding requests and understand how to use these metrics in clinical practice. Methods: In two tertiary medical centers, funding requests for surgeon gap support (2019 to 2020) and equipment (2017 to 2019) within departments of surgery were reviewed. The requesting department, approval status, and amount allotted were recorded. In requests for gap support, projections for contribution margin, operating room volume, charges, collections, and relative value units were tracked. Projected contribution margin and cost savings were recorded for equipment funding requests. Results: There were 40 gap support and 24 equipment requests, and all were approved. Most gap support requests included collections (90.0 percent), charges (87.5 percent), operating room cases (80.0 percent), relative value units (77.5 percent), and hospital contribution margin (77.5 percent). The most represented departments were general surgery (37.5 percent), neurosurgery (22.5 percent), and plastic surgery (15.0 percent). The departments that submitted the most equipment requests were general surgery (28.0 percent) and neurosurgery (28.0 percent). Most requests included projections for contribution margin (95.8 percent) and cost savings (87.4 percent). Projected hospital contribution margin correlated with the amount of funds allotted for surgeon support (r = 0.409; p = 0.022). Conclusions: This multicenter study identified the importance of using key performance indicators for a successful financial outcome in funding requests. In addition, the authors demonstrate the need for surgeons to understand their own key performance indicators. Surgeons should advocate for increased transparency to better understand their financial contributions and performance.
Effect of Reduction Mammoplasty on Pulmonary Function Tests
Guliyeva, Günel , Cheung, Joseph , Huayllani, María T. , Broer, P. Niclas, Forte, Antonio J. , Cheung, Joseph Y, Forte, Antonio Jorge , Cheung, Joseph , Ávila, Francisco R. , Boczar, Daniel

Annals of Plastic Surgery | April 23, 2021 | Volume: 87 | Issue: 6 | Pages: 694-698

10.1097/sap.0000000000002834 Get It

Abstract In patients with breast hypertrophy, excessive breast weight applies pressure on the thorax, which may disrupt the normal breathing. The purpose of this study is to evaluate the impact of the breast hypertrophy and reduction mammoplasty on respiratory function. A comprehensive search of 3 databases, PubMed, Ovid, and Scopus databases, was performed. “Mammoplasty” and “respiration or pulmonary function tests” were the keywords used to search for relevant articles. Ten studies involving 280 patients with breast hypertrophy were included in the final review. Seven articles demonstrated an increase in at least 1 pulmonary function test value after the surgery. This systematic review revealed that, preoperatively, pulmonary function test values of the patients are usually in the normal range. Nonetheless, reduction mammoplasty still improves lung function parameters. Additionally, patients with respiratory complaints felt improvement in their symptoms after the surgery. However, future studies are needed, as heterogeneity among studies was observed.
The deep inferior epigastric lymphatic cable flap connected to gastroepiploic lymph node flap for treatment of refractory chylous ascites: Report of two cases
Ciudad, Pedro , Bustos, Samyd S. , Manrique, Oscar J. , Bolletta, Alberto , Forte, Antonio J. , Huayllani, María T. , Agko, Mouchammed , Urbina, J. Antonio, Date, Shivprasad , Kaya, Burak , Bolletta, Alberto , Forte, Antonio Jorge , Huayllani, Maria T , Mouchammed, Agko , Date, Shivprasad , Bustos, S S , Chen, Hung‐Chi

Microsurgery | April 17, 2021 | Volume: 41 | Issue: 4 | Pages: 376-383

10.1002/micr.30736 Get It

AbstractChylous ascites is the leakage of lipid‐rich lymph into the peritoneal cavity usually due to disruption of lymphatics or increased peritoneal lymphatic pressure. Various surgical options have been proposed to treat chylous ascites but most have shown suboptimal outcomes. The gastroepiploic vascularized lymph node (GE‐VLN) flap has been described previously for the treatment of lymphedema. In chylous ascites, this flap could provide an alternate drainage pathway for the intraperitoneal chylous fluid. The purpose of this report is to present another option for the microsurgical treatment of refractory chylous ascites. Herein, we report two patients with refractory chylous ascites secondary to cancer who have undergone deep inferior epigastric‐based lymphatic “cable” flap (DIE‐LCF) connected to a pedicle GE‐VLN flap. Patients were followed‐up for a minimum of 2 years. Within the first 3 months following surgery, the patient's nutritional parameters improved along with drastic reduction of ascites. At 2 years follow‐up postoperative abdominal circumference decreased significantly. None required further peritoneal paracentesis and all patients were free of chylous ascites symptoms. In conclusion, the DIE‐LCF connected to a pedicle GE‐VLN flap could be a feasible option for the microsurgical treatment of refractory chylous ascites.
Blindness Due to Cosmetic Fillers: Could Stem Cells Be the Answer?
Torres‐Guzman, Ricardo A. , Guliyeva, Günel , Huayllani, María T. , Forte, Antonio J. , Avila, Francisco, Forte, Antonio Jorge , Torres, Ricardo A , Ávila, Francisco R.

Aesthetic Surgery Journal | April 15, 2021 | Volume: 41 | Issue: 10 | Pages: NP1343-NP1344

10.1093/asj/sjab186 Get It

Correlation of older age with severity of lymphedema in breast cancer survivors: A systematic review
Guliyeva, Günel , Huayllani, María T. , Forte, Antonio J. , Boczar, Daniel , Ávila, Francisco R. , Forte, Antonio Jorge

Breast Disease | April 13, 2021 | Volume: 40 | Issue: 3 | Pages: 191-197

10.3233/bd-201067 Get It

BACKGROUND: Breast cancer is the most frequent cause of secondary lymphedema. Besides being progressive and chronic, lymphedema is usually hard to treat. That is why the clinicians are more focused on the prevention of its development and progression. OBJECTIVE: The aim of this study is to evaluate the possible relationship between the age of patients and the severity of breast cancer-related lymphedema (BCRL). METHODS: PubMed, Scopus, and Ovid MEDLINE databases were searched for articles, which described the relationship between aging and BCRL development. Two authors searched for and selected articles independently. RESULTS: Out of 562 studies selected, 8 studies met the inclusion criteria. However, 2 papers had the same study population, so only 7 were included in the final analysis. The total number of patients in those 7 studies was 3,904. Five out of 7 studies included in our review depicted the association of more severe forms of BCRL with older age. CONCLUSION: The final analysis showed that aging is related to the severity of BCRL. However, due to heterogeneity in study outcome reporting, the cause and effect relationship could not be determined.
Vascularized omental lymphatic transplant for upper extremity lymphedema: A systematic review
Jarvis, Nicholas R. , Forte, Antonio J. , Rebecca, Alanna M. , Teven, Chad M. , Torres, Ricardo A, Ávila, Francisco R. , Forte, Antonio Jorge , Teven, Chad M , Torres‐Guzman, Ricardo A.

Cancer Reports | April 7, 2021 | Volume: 4 | Issue: 4 | Pages: No page available

10.1002/cnr2.1370 Get It

AbstractBackgroundVascularized omental lymphatic transplant (VOLT) is an increasingly popular treatment of extremity lymphedema given its promising donor site. While the success of VOLT in the treatment of lymphedema has been reported previously, several questions remain.AimTo further elucidate appropriate use of VOLT in the treatment of lymphedema, specifically addressing patient selection, harvest technique, and operative methods.Methods and ResultsA systematic review of VOLT for upper extremity lymphedema was performed. Of 115 yield studies, seven were included for analysis based on inclusion and exclusion criteria. Included studies demonstrated significant reductions in extremity circumference/volume (average volume reduction, 22.7%‐39.5%) as well as subjective improvements using patient‐reported outcomes. Though studies are heterogenous and limited, when analyzed in aggregate, suggest the efficacy of VOLT in lymphedema treatment.ConclusionThis is the largest systematic review of VOLT to date. VOLT continues to show promise as a safe and efficacious surgical intervention for lymphedema in the upper extremity. Further studies are warranted to more definitively identify patients for whom this technique is appropriate as well as ideal harvest and inset technique.