Abstract On average, females have smaller airways than males. The largest discrepancy in airway size occurs during puberty, when endogenous sex hormone concentrations diverge between males and females. Transgender individuals often use gender‐affirming hormone therapy (GAHT) to align physical characteristics with gender identity. It is unknown whether GAHT influences airway size (luminal area and length). We evaluated the large conducting airways before starting GAHT and while undergoing years of GAHT. This retrospective within‐subject study included 12 adult transgender individuals who underwent CT scanning before starting GAHT and again after ≥1 year of GAHT. For each transgender individual, we identified two matched cisgender controls (one male and one female) who also underwent two CT scans over a comparable time interval for longitudinal comparison. We used a three‐dimensional reconstruction of CT imaging to measure luminal areas. Within‐subject changes in airway size between scans were assessed using Student's paired t ‐tests in transgender individuals undergoing feminizing hormone therapy. Variance between scans was assessed using Levene's test. Pre‐scans occurred an average of 2.0 ± 3.1 years before beginning GAHT. Transgender persons were on GAHT for an average of 3.3 ± 1.7 years (range, 1.0 – 6.7 years) at their second scan. We found no significant differences in airway luminal cross‐sectional areas for transgender persons on feminizing hormone therapy. The variance in airway size change between scans was not statistically different between transgender individuals and control subjects. Our findings suggest that the size of large conducting airways might remain unchanged after a period (>1 year) on GAHT.
Cephalic Vein Interposition Graft for Salvage of Compromised
DIEP
Flap in Breast Reconstruction
ABSTRACT The deep inferior epigastric perforator (DIEP) flap remains the preferred flap option for autologous breast reconstruction following mastectomy. This case report presents the novel use of the cephalic vein (CV) as an interposition graft to alleviate venous congestion in a patient undergoing DIEP flap reconstruction. A 42‐year‐old woman experienced venous congestion following her initial autologous reconstruction, attributed to thrombus formation from kinking of the vascular pedicle. Despite initial attempts to resolve the congestion, the condition persisted. Since the flap was based on a single perforator, we decided to attempt a CV turndown. The CV was noted to be attenuated and not feasible for use in turndown; therefore, venous salvage was completed by using the CV as an interposition graft to bypass the affected flap vena comitans. The procedure successfully restored venous flow, allowing for flap salvage and subsequent healing. This case underscores the potential of CV as an interposition graft in autologous breast reconstruction, particularly when traditional CV turndown is not possible due to vessel attenuation.
Institutional Experience in Virtual Surgical Planning and Three-Dimensional Printing in Plastic Surgery Presented During: View Presentation
ABSTRACT Genital lymphedema presents significant challenges in surgical management, with limited effective interventions. This case report explores the use of contrast‐enhanced ultrasound (CEUS) with microbubble injection as an alternative adjunct technique for lymphatic mapping in lymphaticovenous anastomosis (LVA) surgery for genital lymphedema. A retrospective chart review approved by our institutional review board was performed for patients with genital lymphedema undergoing LVA surgery between 2020 and 2024. Intraoperative CEUS for lymphatic mapping was used with intradermal injection of microbubble suspension Lumason (Bracco Suisse, Monroe Township, NJ, USA). Data regarding demographics, comorbidities, clinical and operative characteristics, complications, and surgical outcomes were retrieved. Three patients with genital lymphedema who underwent LVA were identified. The first patient was a 34‐year‐old female with recurrent lymphangioma circumscriptum and vesicular drainage. She successfully underwent CEUS‐guided LVA followed by two debulking procedures. The second patient was a 16‐year‐old male with congenital scrotal and lower extremity lymphedema. He had two CEUS‐guided LVAs and subsequent debulking for anterior scrotal swelling, with long‐term reduction in edema. The third patient was a 31‐year‐old female with primary lymphedema of the right lower extremity and genital region. She underwent seven CEUS and indocyanine green lymphography (ICG) guided anastomoses targeting the mons and lower abdomen, resulting in substantial symptomatic and volumetric improvement. CEUS detected target lymphatic vessels in all cases, including cases where ICG imaging failed to identify candidate lymphatic vessels. CEUS with intradermal microbubble injection successfully identified target lymphatic vessels in the preoperative planning for LVA surgery in patients with genital lymphedema.
Comparative Evaluation of Contrast-enhanced Ultrasound and Indocyanine Green Lymphography for Lymphatic Mapping: A Retrospective Study
Background: Lymphaticovenous anastomosis (LVA) is an effective surgical treatment for extremity lymphedema. Indocyanine green (ICG) fluorescent lymphography, the traditional standard for imaging lymphatic vessels, has limitations, including difficulty depicting deeper or congested lymphatics and contraindication in iodine hypersensitivity. This study evaluated contrast-enhanced ultrasound (CEUS) with microbubbles for identifying lymphatic vessels for LVA and compared it with ICG lymphography. Methods: In this single-center retrospective review, intraoperative CEUS with intradermal injection of microbubble suspension (Lumason, Bracco Diagnostics, Inc.) was used in patients before LVA surgery between October 2019 and February 2023. Pre- or intraoperative ICG lymphography was also used to identify target lymphatic vessels. All patients diagnosed with primary or secondary extremity lymphedema who underwent LVA were included. Technical success rate was defined as lymphatic vessels identified by CEUS that led to successful LVAs. Descriptive statistics were used. Results: Thirty-two patients underwent LVA surgery, with a mean age of 58.5 ± 13.9 years. CEUS identified lymphatic vessels in all 32 patients, including 7 in whom ICG failed. Two patients with ICG allergy underwent CEUS only. CEUS identified more candidate lymphatics per patient (5.3 ± 4.2) compared with ICG (2.5 ± 2.7). Of the 182 anastomoses, 96 (52.8%) were identified by both CEUS and ICG, 75 (41.2%) by CEUS only, and 11 (6%) by ICG only. Conclusions: CEUS is a promising tool for identifying lymphatic vessels in patients with lymphedema undergoing LVA, particularly when ICG lymphography is inadequate or contraindicated.
P3. Unveiling Weight Loss Trends and Complications in Body Contouring Surgery Among Glucagon Like Peptide Analogs Users: An Eight Year Experience
Background: With neck, aging the cervicomental angle becomes obtuse and may be influenced by hyoid bone aging. An understanding of hyoid position changes with aging will further our understanding of its role in neck contour changes. Methods: A 3D volumetric reconstruction of 282 neck computed tomography scans was performed. The cohort was categorized into three groups based on age: 20 years or older and younger than 40 years, 40 years or older and younger than 60 years, and 60 years or older and younger than 80 years. The vertical and horizontal hyoid distances in relation to the mandible were calculated for each patient. Results: A total of 282 patients (153 women, 129 men) were included in the cohort. The age groups were evenly distributed in men and women. Mean hyoid vertical and horizontal distances differed between women and men in all age groups. There was a significant difference in the hyoid vertical distance between 20–39 years old to 40–59 years old in men (P < 0.01), and 20–39 years old to 60–79 years old in both genders (women P = 0.005, men P < 0.01). Hyoid horizontal distance was not affected by age and sex (age and sex: P > 0.05), but rather by body mass index (BMI). Every 5 BMI points corresponded to a forward movement of 2 mm. Conclusions: As individuals age, the hyoid bone descends in both sexes, and an increase in BMI is associated with forward movement. Additional studies are needed to assess the correlation of the hyoid position between upright and supine positions.
Lymphatic Mapping with Contrast-enhanced Ultrasound for Lymphaticovenous Anastomosis Surgery: How We Do It
Summary: Lymphaticovenous anastomosis (LVA) surgery is an effective surgery for the treatment of lymphedema in the extremities. Indocyanine green lymphography is the reference standard for visualizing lymphatics for LVA surgery, but it has several limitations; most notably, superficial dermal congestion can mask deeper lymphatic vessels. To overcome the limitations, we add contrast-enhanced ultrasound (CEUS) lymphography. We have previously reported that CEUS lymphography can identify lymphatic vessels for LVA surgery that indocyanine green lymphography does not. Here, we describe how we perform CEUS lymphography, including workflow, technique, and documentation. Before informed consent, the patient must be screened for possible adverse reactions to microbubbles. The procedure involves multiple intradermal injections of the microbubble agent at various sites along the extremity. After each injection, imaging for microbubble uptake by lymphatic vessels is performed using an ultrasound scanner with contrast-specific software. We use sulfur hexafluoride lipid-type A microspheres (Lumason/SonoVue; Bracco Suisse SA), but we are investigating the performance of other Food & Drug Administration–approved microbubble agents for CEUS lymphography. Having a systematic approach to marking the skin can mitigate the hindrance of marking over ultrasound coupling gel. Another benefit of CEUS lymphography is the rapid identification of neighboring veins compatible in size and location for anastomosis. We hold regular scheduled multidisciplinary meetings for coordination of care, discussion of outcomes, quality assurance, and ongoing innovation.
Pharmacologic and Other Noninvasive Treatments of the Aging Face: A Review of the Current Evidence
Summary: Aging of the face is the result of the interrelation of three-dimensional changes occurring over time among the 5 different layers of the face and its associated structures. Knowledge regarding the causes of these changes and identification of new key anatomic structures have helped elucidate one of the most complex areas of the human body. This has resulted in the introduction of pharmacologic agents to help stop, mitigate, or counteract signs of aging and restore the youthful appearance of the face. The authors performed a systematic search of the literature to review the current highest-level evidence of facial antiaging pharmacologic agents. Pharmacologic and minimally invasive antiaging treatments can target different components of facial aging and continue to evolve. With continuous research efforts, traditional treatments, such as botulinum toxin type A, injectable fillers, and chemical peels, are emerging in newer, more effective formulations, with longer lasting clinical results. However, for soft-tissue descent and facial volume loss, surgery remains the standard treatment. An adequate understanding of the three-dimensional process of facial aging over time (the fourth dimension), facial anatomy, and the pharmacologic properties of antiaging/rejuvenation agents are the sine qua non of facial antiaging treatment. The specific modality should be tailored to patient characteristics, preferences, and goals.
Surgical and Patient-Reported Outcomes of Open Perforator-Preserving Anterior Component Separation for Ventral Hernia Repair
Abstract Background Abdominal wall reconstruction is challenging for surgeons and may be life altering for patients. There are scant high-quality studies on patient-reported outcomes following abdominal wall reconstruction. We assess long-term surgical and patient-reported outcomes of perforator-preserving open anterior component separation (OPP-ACS) following large ventral hernia repair. Methods A retrospective review of patients with large ventral hernia defects who underwent OPP-ACS performed by the authors (B.A.S., M.J.T.) was conducted between 2015 and 2019. Demographics, surgical history, operative details, outcomes, and complications were extracted. A validated questionnaire, Carolinas Comfort Scale (CCS), was used to assess postoperative quality of life. Results Twenty-two patients (12 males and 10 females) with a mean age and BMI of 60.9 ± 10 years and 28.9 ± 4.8 kg/m2, respectively, were included. Mean follow-up was 28.5 ± 16.3 months. All had prior abdominal surgery; 15 (68%) for abdominopelvic malignancy, 3 (14%) for previous failed hernia repair, and 8 (36%) had history of abdominopelvic radiation. Overall, 16 (73%) hernias were in the midline, 4 (18%) in the right lower quadrant, 1 (4.5%) in the right upper quadrant, and 1 (4.5%) in the left lower quadrant. Mean hernia defect surface area was 145 ± 112 cm2. A total of 9 patients (40.9%) underwent bilateral component separation, whereas 13 (59.1%) had unilateral. Bioprosthetic mesh was used in all patients as underlay. Mean mesh size and thickness were 545.6 ± 207.7 cm2 and 3.4 ± 0.5 mm, respectively. One patient presented with a minor wound dehiscence, and two presented with seromas not requiring aspiration/evacuation. One patient had hernia recurrence 22 months after surgery. One patient was readmitted for partial small bowel obstruction and one required wound revision. A total of 14 (65%) patients responded to the CCS questionnaire. At 12 months, mean score for all 23 items was 0.29 ± 0.21 (0.08–0.62), which corresponds to absence or minimal symptoms. Conclusion The OPP-ACS is a safe surgical option for large, complex ventral hernias. Our cases showed minimal complication rate and hernia recurrence, and our patients reported significant improvement in life quality.