Gastrointestinal defect closure using a novel through-the-scope helix tack and suture device compared to endoscopic clips in a survival porcine model (with video)
Abstract Background and aims Endoscopic resections are associated with bleeding and perforation and may be managed with through-the-scope (TTS) clips, over-the-scope clips and endoscopic suturing. The aim of this preclinical study was to compare technical success of closure using a novel TTS tissue helix tack and suture device (X-Tack) to TTS clips in a porcine model. Materials and methods Four subjects underwent 40 mucosal resections, diameter range 25–50 mm, in the stomach (n = 24) and colon (n = 16). Closures were randomized to X-Tack (n = 24) or clip (n = 16). Animals underwent weekly endoscopic follow-up for 4 weeks. Results Technical closure with X-Tack was successful in 24 of 24 (100 %) cases and with clips in 13 of 16 cases (81.3 %) (P = 0.0001). One colonic perforation occurred and was successfully managed using X-Tack. The rate of healing was not statistically different between the groups, and all sites healed at 4 weeks including the perforation and were confirmed by histology. Conclusions Compared to TTS clip, X-Tack is superior for effecting large mucosal defect closure, including durable sealing of full-thickness perforation. There was no difference in rate of healing between devices.
Utility of mismatch repair protein expression screening via an endoscopic ultrasound assessment of treatment-naive pancreas ductal adenocarcinoma
Multicentre, prospective, randomised study comparing the diagnostic yield of colon capsule endoscopy versus CT colonography in a screening population (the TOPAZ study)
Objective Colon capsule endoscopy (CCE) has shown promise for colorectal neoplasia detection compared with optical colonoscopy (OC), but has not been compared with other screening tests in average risk screening patients. Design Patients 50 to 75 years of age (African Americans, 45–75 years) were randomised to CCE or CT colonography (CTC) and subsequent blinded OC. The primary endpoint was diagnostic yield of polyps ≥6 mm with CCE or CTC. Secondary endpoints included accuracy for size and histology, examination completeness, number/proportion of subjects with polyps and adenomas ≥6 mm and ≥10 mm, subject satisfaction and safety. Results From 320 enrolled subjects, data from 286 (89.4%) were evaluable. The proportion of subjects with any polyp ≥6 mm confirmed by OC was 31.6% for CCE versus 8.6% for CTC (pPr non-inferiority and superiority=0.999). The diagnostic yield of polyps ≥10 mm was 13.5% with CCE versus 6.3% with CTC (pPr non-inferiority=0.9954). The sensitivity and specificity of CCE for polyps ≥6 mm was 79.2% and 96.3% while that of CTC was 26.8% and 98.9%. The sensitivity and specificity of CCE for polyps ≥10 mm was 85.7% and 98.2% compared with 50% and 99.1% for CTC. Both tests were well tolerated/safe. Conclusion CCE was superior to CTC for detection of polyps ≥6 mm and non-inferior for identification of polyps ≥10 mm. CCE should be considered comparable or superior to CTC as a colorectal neoplasia screening test, although neither test is as effective as OC. Trial registration number ClinicalTrials.gov no: NCT02754661 .
S0308 Prep-Free Screening Capsule to Redefine Colorectal Cancer Screening and Prevention
Utilisation of artificial intelligence for the development of an EUS-convolutional neural network model trained to enhance the diagnosis of autoimmune pancreatitis
Objective The diagnosis of autoimmune pancreatitis (AIP) is challenging. Sonographic and cross-sectional imaging findings of AIP closely mimic pancreatic ductal adenocarcinoma (PDAC) and techniques for tissue sampling of AIP are suboptimal. These limitations often result in delayed or failed diagnosis, which negatively impact patient management and outcomes. This study aimed to create an endoscopic ultrasound (EUS)-based convolutional neural network (CNN) model trained to differentiate AIP from PDAC, chronic pancreatitis (CP) and normal pancreas (NP), with sufficient performance to analyse EUS video in real time. Design A database of still image and video data obtained from EUS examinations of cases of AIP, PDAC, CP and NP was used to develop a CNN. Occlusion heatmap analysis was used to identify sonographic features the CNN valued when differentiating AIP from PDAC. Results From 583 patients (146 AIP, 292 PDAC, 72 CP and 73 NP), a total of 1 174 461 unique EUS images were extracted. For video data, the CNN processed 955 EUS frames per second and was: 99% sensitive, 98% specific for distinguishing AIP from NP; 94% sensitive, 71% specific for distinguishing AIP from CP; 90% sensitive, 93% specific for distinguishing AIP from PDAC; and 90% sensitive, 85% specific for distinguishing AIP from all studied conditions (ie, PDAC, CP and NP). Conclusion The developed EUS-CNN model accurately differentiated AIP from PDAC and benign pancreatic conditions, thereby offering the capability of earlier and more accurate diagnosis. Use of this model offers the potential for more timely and appropriate patient care and improved outcome.
Endoscopic Ultrasound/Fine Needle Aspiration Is Effective for Lymph Node Staging in Patients With Cholangiocarcinoma
Background and Aims Presence of malignant regional lymph nodes (MRLNs) precludes curative oncological resection or liver transplantation for cholangiocarcinoma (CCA). Limited data support the utility of endoscopic ultrasound (EUS)/fine needle aspiration (FNA) for detection of MRLNs in extrahepatic CCA, but there are no data for its role in intrahepatic CCA (iCCA). The aim of this study is to evaluate the staging impact of EUS for CCA, including analysis by subtype. Approach and Results We identified consecutive patients with CCA who underwent EUS staging at a single tertiary care center from October 2014 to April 2018. Among this cohort, we abstracted clinical demographic, radiographical, procedural, cytopathological, and surgical data. STATA 15 software was used for comparative analysis calculations (StataCorp LP, College Station, TX). The study cohort included 157 patients; 24 (15%), 124 (79%), and 9 (6%) with intrahepatic, perihilar, and distal CCA, respectively. EUS was able to identify regional lymph nodes (RLNs) in a higher percentage of patients compared to cross‐sectional imaging (86% vs. 47%; P < 0.001). FNA was performed in 133 (98.5%) patients with RLNs, with a median of three passes per node. EUS‐FNA identified MRLN in 27 of 31 (87.1%) patients ultimately found to have MRLNs. For iCCA, EUS detected a higher percentage of RLN compared to cross‐sectional imaging (83% vs. 50%; P = 0.048), with MRLNs identified in 4 (17%) patients. Among the entire cohort, identification of at least one MRLN by EUS was associated with lower median survival (353 vs. 1,050 days; P < 0.001) and increased risk of death (hazard ratio = 4.1; P < 0.001). Conclusions EUS‐FNA is effective for identifying MRLN in patients with CCA, and should be routinely incorporated into staging of all CCA subtypes given the impact of MRLN on prognosis and management decisions.
Evaluating a combined bowel preparation for small-bowel capsule endoscopy: a prospective randomized–controlled study
Abstract Background Capsule endoscopy (CE) is frequently hindered by intra-luminal debris. Our aim was to determine whether a combination bowel preparation would improve small-bowel visualization, diagnostic yield, and the completion rate of CE. Methods Single-blind, prospective randomized–controlled study of outpatients scheduled for CE. Bowel-preparation subjects ingested 2 L of polyethylene glycol solution the night prior to CE, 5 mL simethicone and 5 mg metoclopramide 20 minutes prior to CE and laid in the right lateral position 30 minutes after swallowing CE. Controls had no solid food after 7 p.m. the night prior to CE and no liquids 4 hours prior to CE. Participants completed a satisfaction survey. Capsule readers completed a small-bowel-visualization assessment. Results Fifty patients were prospectively enrolled (56% female) with a median age of 54.4 years and 44 completed the study (23 patients in the control group and 21 in the preparation group). There was no significant difference between groups on quartile-based small-bowel visualization (all P > 0.05). There was no significant difference between groups in diagnostic yield (P = 0.69), mean gastric (P = 0.10) or small-bowel transit time (P = 0.89). The small-bowel completion rate was significantly higher in the preparation group (100% vs 78%; P = 0.02). Bowel-preparation subjects reported significantly more discomfort than controls (62% vs 17%; P = 0.01). Conclusions Combined bowel preparation did not improve small-bowel visualization but did significantly increase patient discomfort. The CE completion rate improved in the preparation group but the diagnostic yield was unaffected. Based on our findings, a bowel preparation prior to CE does not appear to improve CE performance and results in decreased patient satisfaction (ClinicalTrials.gov, No. NCT01243736).
Efficacy of Difluoromethylornithine and Aspirin for Treatment of Adenomas and Aberrant Crypt Foci in Patients with Prior Advanced Colorectal Neoplasms
Abstract Difluoromethylornithine (DFMO), an inhibitor of polyamine synthesis, was shown to act synergistically with a NSAID for chemoprevention of colorectal neoplasia. We determined the efficacy and safety of DFMO plus aspirin for prevention of colorectal adenomas and regression of rectal aberrant crypt foci (ACF) in patients with prior advanced adenomas or cancer. A double-blinded, placebo-controlled trial was performed in 104 subjects (age 46–83) randomized (1:1) to receive daily DFMO (500 mg orally) plus aspirin (325 mg) or matched placebos for one year. All polyps were removed at baseline. Adenoma number (primary endpoint) and rectal ACF (index cluster and total) were evaluated at a one year colonoscopy. ACF were identified by chromoendoscopy. Toxicity was monitored, including audiometry. Eighty-seven subjects were evaluable for adenomas or ACF modulation (n = 62). At one year of treatment, adenomas were detected in 16 (38.1%) subjects in the DFMO plus aspirin arm (n = 42) versus 18 (40.9%) in the placebo arm (n = 44; P = 0.790); advanced adenomas were similar (n = 3/arm). DFMO plus aspirin was associated with a statistically significant reduction in the median number of rectal ACF compared with placebo (P = 0.036). Total rectal ACF burden was also reduced in the treatment versus the placebo arm relative to baseline (74% vs. 45%, P = 0.020). No increase in adverse events, including ototoxicity, was observed in the treatment versus placebo arms. While adenoma recurrence was not significantly reduced by one year of DFMO plus aspirin, the drug combination significantly reduced rectal ACF number consistent with a chemopreventive effect.
Patient-oriented education and visual-aid intervention are inadequate to identify patients with potential capsule retention: a prospective randomized study
Abstract Background/aims The rate of recurrent small-bowel bleeding (SBB) remains high despite the advent of balloon assisted enteroscopy (BAE). The study aims were to determine: (1) the diagnostic and therapeutic yields, and adverse event rate of repeat BAE in SBB, and (2) the predictors of a positive repeat BAE. Methods A retrospective review of a BAE database was conducted. Patients who had > 1 BAE for SBB were included. Primary outcomes were diagnostic yield, therapeutic yield, and adverse events of repeat BAE. Secondary outcomes were predictors of a positive repeat BAE. Results A total of 175 patients (55 % men; mean age 64.1 ± 16.3 years) were included. The diagnostic and therapeutic yields of repeat BAE were 55 % and 42 %, respectively. Repeat BAE adverse events occurred in 5 % with self-limited abdominal pain being most common. Patients with a positive repeat BAE were significantly older than the negative group (68.6 ± 13.9 vs. 60.9 ± 17.1; P = 0.001) and were more likely to have cardiac comorbidities (OR 2.4, 95 %CI: 1.3 – 4.6; P = 0.01), chronic kidney disease (OR 2.3, 95 %CI: 1.1 – 4.9; P = 0.04), chronic obstructive pulmonary disease (OR 3.3, 95 %CI: 1.3 – 8.1; P = 0.01), positive initial BAE (OR 3.6, 95 %CI: 1.9 – 6.8; P < 0.001), and antegrade procedure (OR 3.3, 95 %CI: 1.7 – 6.1; P < 0.001). On multivariate analysis, a positive initial BAE and antegrade route were the only significant predictive factors. Conclusions Performing a repeat BAE for SBB appears safe and provided modest yields. A positive initial BAE and antegrade route were predictive of a positive repeat BAE.