Correct diagnosis of seizure type and epilepsy syndrome is the foundation for appropriate antiepileptic drug selection. Inappropriate medication choices occur in the treatment of generalized epilepsy and may aggravate some seizure types, including absence seizures, potentially leading to pseudo‐drug resistance. Fortunately, a correct diagnosis of absence seizures is usually not difficult, though rarely demonstrates electroclinical overlap with focal seizures. EEG can be especially misleading when secondary bilateral synchronous discharges occur in patients with focal seizures. However, the semiology of focal seizures associated with mesial temporal lobe epilepsy has a characteristic and consistent semiology that is the mark of this common epilepsy syndrome in adulthood. We recently encountered a 53‐year‐old female with refractory seizures and a semiology strongly suggesting mesial temporal lobe epilepsy. Instead of focal seizures, prolonged absence seizures were validated by video‐EEG monitoring and she became seizure‐free after a change to broad‐spectrum antiepileptic drugs. This case further expands our understanding of the complexity of semiology in electroclinical classification and the spectrum that may occur in adult absence seizures. It serves to underscore the need for ictal EEG recordings and the importance of concordance with the clinical course during the pre‐surgical evaluation of patients with lesions and drug‐resistant epilepsy. [Published with video sequences]
Time Is Brain: The Use of EEG Electrode Caps to Rapidly Diagnose Nonconvulsive Status Epilepticus
Objective: To perform a feasibility pilot study comparing the usefulness of EEG electrode cap versus standard scalp EEG for acquiring emergent EEGs in emergency department, inpatient, and intensive care unit patients. Background: Nonconvulsive status epilepticus (NCSE) is a neurological emergency diagnosed exclusively by EEG. Nonconvulsive status epilepticus becomes more resistant to treatment 1 hour after continued seizure activity. EEG technologists are alerted “stat” when there is immediate need for an EEG during oncall hours, yet delays are inevitable. Alternatively, EEG caps can be quickly placed by in-house residents at bedside for assessment. Design/Methods: EEG caps were compared with standard-of-care “stat” EEGs for 20 patients with suspected NCSE. After the order for a stat EEG was placed, neurology residents were simultaneously alerted and placed an EEG cap prior to the arrival of the on-call out-of-hospital technologist. Both EEG cap recordings and standard EEG recordings were visually reviewed at 10 and 20 minutes in a blinded manner by two electroencephalographers. The timing, accuracy of interpretation, and diagnosis between the two techniques were then compared. Results: Of the 20 adult patients, 70% (14 of 20) of EEG cap recordings were interpretable, whereas 95% (19 of 20) standard EEGs were interpretable; three had findings consistent with NCSE on both the EEG cap and standard EEG recordings. In the time analysis, 16 patients were included. EEG cap placement was significantly more time efficient than an EEG performed by technologist using the usual “stat” EEG protocol, with the median EEG cap electrode placement occurring 86 minutes faster than standard EEG (22.5 minutes vs. 104.5 minutes; P < 0.0001; n = 16). Conclusions: New rapid EEG recording using improved EEG caps may allow for rapid diagnosis and clinical decision making in suspected NCSE.
A 360° electronic device for recording high-resolution intraoperative electrocorticography of the brain during awake craniotomy
OBJECTIVEEpilepsy is common among patients with supratentorial brain tumors; approximately 40%–70% of patients with glioma develop brain tumor–related epilepsy (BTRE). Intraoperative localization of the epileptogenic zone during surgical tumor resection (real-time data) may improve intervention techniques in patients with lesional epilepsy, including BTRE. Accurate localization of the epileptogenic signals requires electrodes with high-density spatial organization that must be placed on the cortical surface during surgery. The authors investigated a 360° high-density ring-shaped cortical electrode assembly device, called the “circular grid,” that allows for simultaneous tumor resection and real-time electrophysiology data recording from the brain surface.METHODSThe authors collected data from 99 patients who underwent awake craniotomy from January 2008 to December 2018 (29 patients with the circular grid and 70 patients with strip electrodes), of whom 50 patients were matched-pair analyzed (25 patients with the circular grid and 25 patients with strip electrodes). Multiple variables were then retrospectively assessed to determine if utilization of this device provides more accurate real-time data and improves patient outcomes.RESULTSMatched-pair analysis showed higher extent of resection (p = 0.03) and a shorter transient motor recovery period during the hospitalization course (by approximately 6.6 days, p ≤ 0.05) in the circular grid patients. Postoperative versus preoperative Karnofsky Performance Scale (KPS) score difference/drop was greater for the strip electrode patients (p = 0.007). No significant difference in postoperative seizures between the 2 groups was present (p = 0.80).CONCLUSIONSThe circular grid is a safe, feasible tool that grants direct access to the cortical surgical surface for tissue resection while simultaneously monitoring electrical activity. Application of the circular grid to different brain pathologies may improve intraoperative epileptogenic detection accuracy and functional outcomes, while decreasing postoperative complications.
Summary: Smartphones and other personal electronic devices present novel cortical processing tasks with potential for identification of novel EEG waveforms. A 17-year-old patient with epilepsy manifested as recurrent myoclonic seizures, absence seizures, and a single generalized tonic–clonic seizure was hospitalized to undergo video-EEG monitoring for seizure quantification and classification of the epilepsy syndrome. During the monitoring session, a frontocentral predominant 5 to 6 Hz theta rhythm was identified only when the patient was actively texting or playing a video game on his smartphone. Previously, patients with focal epilepsy have been found to have a frontocentral theta rhythm on EEG while texting on mobile devices. We report similar EEG findings in a patient with genetic generalized epilepsy during smartphone gaming to expand the population and triggers for this theta waveform. Given the young age and type of epilepsy, we suggest that the waveform represents the EEG manifestation of the attention–visuomotor pathway that is stimulus independent.
P2‐290: ELECTROENCEPHALOGRAM FINDINGS IN PATIENTS WITH POSTERIOR CORTICAL ATROPHY
Cavernomas make up approximately 8%–15% of all intracranial vascular malformations, and the most common presenting symptom is seizures. Complete resection of the cavernoma and removal of the surrounding gliotic core presents a cure but poses a challenge if an eloquent brain is involved or with incomplete resection of the epileptogenic foci. The authors present the case of a 53-year-old man with intractable seizures from a left posterior temporal lobe cavernoma who underwent an awake craniotomy with intraoperative seizure monitoring via electrocorticography. The video can be found here: https://youtu.be/vxaikozg2g4 .
Laser ablation for mesial temporal epilepsy: a multi-site, single institutional series
OBJECTIVE Although it is still early in its application, laser interstitial thermal therapy (LiTT) has increasingly been employed as a surgical option for patients with mesial temporal lobe epilepsy. This study aimed to describe mesial temporal lobe ablation volumes and seizure outcomes following LiTT across the Mayo Clinic’s 3 epilepsy surgery centers. METHODS This was a multi-site, single-institution, retrospective review of seizure outcomes and ablation volumes following LiTT for medically intractable mesial temporal lobe epilepsy between October 2011 and October 2015. Pre-ablation and post-ablation follow-up volumes of the hippocampus were measured using FreeSurfer, and the volume of ablated tissue was also measured on intraoperative MRI using a supervised spline-based edge detection algorithm. To determine seizure outcomes, results were compared between those patients who were seizure free and those who continued to experience seizures. RESULTS There were 23 patients who underwent mesial temporal LiTT within the study period. Fifteen patients (65%) had left-sided procedures. The median follow-up was 34 months (range 12–70 months). The mean ablation volume was 6888 mm 3 . Median hippocampal ablation was 65%, with a median amygdala ablation of 43%. At last follow-up, 11 (48%) of these patients were seizure free. There was no correlation between ablation volume and seizure freedom (p = 0.69). There was also no correlation between percent ablation of the amygdala (p = 0.28) or hippocampus (p = 0.82) and seizure outcomes. Twelve patients underwent formal testing with computational visual fields. Visual field changes were seen in 67% of patients who underwent testing. Comparing the 5 patients with clinically noticeable visual field deficits to the rest of the cohort showed no significant difference in ablation volume between those patients with visual field deficits and those without (p = 0.94). There were 11 patients with follow-up neuropsychological testing. Within this group, verbal learning retention was 76% in the patients with left-sided procedures and 89% in those with right-sided procedures. CONCLUSIONS In this study, there was no significant correlation between the ablation volume after LiTT and seizure outcomes. Visual field deficits were common in formally tested patients, much as in patients treated with open temporal lobectomy. Further studies are required to determine the role of amygdalohippocampal ablation.
Clinical and Electrographic Correlates of Bilateral Independent Periodic Discharges
Purpose: Periodic discharges (PDs) are EEG patterns denoting brain dysfunction and ictal tendency. Their exact meaning regarding etiology and outcomes is not well known. In particular, bilateral independent PDs (BIPDs) are poorly described. Methods: We performed a retrospective, multicenter study evaluating neuroimaging, epileptic, clinical, and EEG correlates of BIPDs. Results: Twenty-five patients studied with a mean Glasgow Coma Scale 6.5 and modified Rankin scale 3.9 who underwent EEG monitoring, mean duration 287 hours (range 0.75–3,216). Most common causes of BIPDs were cardiac arrest, Central Nervous System infections, and acute/chronic ischemic/hemorrhagic stroke. Most had subcortical and cortical injuries on neuroimaging. Most of the PDs ranged from 0.5 to 2 Hz in frequency, were of multiple phase types, and localized to the frontal head regions. Eighteen of 25 patients had clinical or electrographic seizures. There was a trend toward seizures in those with BIPDs with a history of epilepsy (P = 0.08) and acute metabolic dysfunction (P = 0.08), particularly with coincident acute structural lesions (P = 0.05). Seizures were predicted by bilaterally symmetric frequencies (P = 0.02) and trended toward higher likelihood with PD frequency <2 Hz (P = 0.08). Two of 25 patients survived past discharge with modified Rankin scale <3. Cardiac arrest was associated with withdrawal of life-sustaining therapy (P < 0.001). Conclusions: BIPDs arise from acute and chronic neurologic injuries, often associated with metabolic dysfunction. Outcomes are poor in this population. Seizures are common, particularly in patients with PDs that are of a lower frequency or are symmetric in frequency. Further study is warranted to evaluate the association between BIPDs and seizures, as well as functional and longer term outcomes.
High-frequency oscillations in awake patients undergoing brain tumor-related epilepsy surgery
Summary Objective A prospective multicenter phase III trial was undertaken to evaluate the performance and tolerability in the epilepsy monitoring unit ( EMU ) of an investigational wearable surface electromyographic ( sEMG ) monitoring system for the detection of generalized tonic–clonic seizures ( GTCSs ). Methods One hundred ninety‐nine patients with a history of GTCSs who were admitted to the EMU in 11 level IV epilepsy centers for clinically indicated video‐electroencephalographic monitoring also received sEMG monitoring with a wearable device that was worn on the arm over the biceps muscle. All recorded sEMG data were processed at a central site using a previously developed detection algorithm. Detected GTCSs were compared to events verified by a majority of three expert reviewers. Results For all subjects, the detection algorithm detected 35 of 46 (76%, 95% confidence interval [CI] = 0.61–0.87) of the GTCSs, with a positive predictive value ( PPV ) of 0.03 and a mean false alarm rate ( FAR ) of 2.52 per 24 h. For data recorded while the device was placed over the midline of the biceps muscle, the system detected 29 of 29 GTCSs (100%, 95% CI = 0.88–1.00), with a detection delay averaging 7.70 s, a PPV of 6.2%, and a mean FAR of 1.44 per 24 h. Mild to moderate adverse events were reported in 28% (55 of 199) of subjects and led to study withdrawal in 9% (17 of 199). These adverse events consisted mostly of skin irritation caused by the electrode patch that resolved without treatment. No serious adverse events were reported. Significance Detection of GTCSs using an sEMG monitoring device on the biceps is feasible. Proper positioning of this device is important for accuracy, and for some patients, minimizing the number of false positives may be challenging.