ABSTRACTDespite advancements in the neurophysiology of language and presurgical evaluation for epilepsy surgery, there is a paucity of information in the literature regarding presurgical evaluation of multilingual patients. We present a case of a 52‐year‐old right‐handed woman with refractory epilepsy who was fluent in six languages and underwent subsequent trilingual presurgical evaluation which included neuropsychological testing, Wada testing, functional magnetic resonance imaging (fMRI), and electrocortical stimulation. These studies suggested a seizure focus in the left temporal lobe and language localization that was predominantly right‐hemispheric; she subsequently underwent left temporal laser interstitial thermal therapy without clinical disturbance in language function while remaining seizure‐free. A multidisciplinary effort was integral in providing an optimal outcome for this patient.
Time Is Brain: The Use of EEG Electrode Caps to Rapidly Diagnose Nonconvulsive Status Epilepticus
Objective: To perform a feasibility pilot study comparing the usefulness of EEG electrode cap versus standard scalp EEG for acquiring emergent EEGs in emergency department, inpatient, and intensive care unit patients. Background: Nonconvulsive status epilepticus (NCSE) is a neurological emergency diagnosed exclusively by EEG. Nonconvulsive status epilepticus becomes more resistant to treatment 1 hour after continued seizure activity. EEG technologists are alerted “stat” when there is immediate need for an EEG during oncall hours, yet delays are inevitable. Alternatively, EEG caps can be quickly placed by in-house residents at bedside for assessment. Design/Methods: EEG caps were compared with standard-of-care “stat” EEGs for 20 patients with suspected NCSE. After the order for a stat EEG was placed, neurology residents were simultaneously alerted and placed an EEG cap prior to the arrival of the on-call out-of-hospital technologist. Both EEG cap recordings and standard EEG recordings were visually reviewed at 10 and 20 minutes in a blinded manner by two electroencephalographers. The timing, accuracy of interpretation, and diagnosis between the two techniques were then compared. Results: Of the 20 adult patients, 70% (14 of 20) of EEG cap recordings were interpretable, whereas 95% (19 of 20) standard EEGs were interpretable; three had findings consistent with NCSE on both the EEG cap and standard EEG recordings. In the time analysis, 16 patients were included. EEG cap placement was significantly more time efficient than an EEG performed by technologist using the usual “stat” EEG protocol, with the median EEG cap electrode placement occurring 86 minutes faster than standard EEG (22.5 minutes vs. 104.5 minutes; P < 0.0001; n = 16). Conclusions: New rapid EEG recording using improved EEG caps may allow for rapid diagnosis and clinical decision making in suspected NCSE.
A 360° electronic device for recording high-resolution intraoperative electrocorticography of the brain during awake craniotomy
OBJECTIVEEpilepsy is common among patients with supratentorial brain tumors; approximately 40%–70% of patients with glioma develop brain tumor–related epilepsy (BTRE). Intraoperative localization of the epileptogenic zone during surgical tumor resection (real-time data) may improve intervention techniques in patients with lesional epilepsy, including BTRE. Accurate localization of the epileptogenic signals requires electrodes with high-density spatial organization that must be placed on the cortical surface during surgery. The authors investigated a 360° high-density ring-shaped cortical electrode assembly device, called the “circular grid,” that allows for simultaneous tumor resection and real-time electrophysiology data recording from the brain surface.METHODSThe authors collected data from 99 patients who underwent awake craniotomy from January 2008 to December 2018 (29 patients with the circular grid and 70 patients with strip electrodes), of whom 50 patients were matched-pair analyzed (25 patients with the circular grid and 25 patients with strip electrodes). Multiple variables were then retrospectively assessed to determine if utilization of this device provides more accurate real-time data and improves patient outcomes.RESULTSMatched-pair analysis showed higher extent of resection (p = 0.03) and a shorter transient motor recovery period during the hospitalization course (by approximately 6.6 days, p ≤ 0.05) in the circular grid patients. Postoperative versus preoperative Karnofsky Performance Scale (KPS) score difference/drop was greater for the strip electrode patients (p = 0.007). No significant difference in postoperative seizures between the 2 groups was present (p = 0.80).CONCLUSIONSThe circular grid is a safe, feasible tool that grants direct access to the cortical surgical surface for tissue resection while simultaneously monitoring electrical activity. Application of the circular grid to different brain pathologies may improve intraoperative epileptogenic detection accuracy and functional outcomes, while decreasing postoperative complications.
Summary: Smartphones and other personal electronic devices present novel cortical processing tasks with potential for identification of novel EEG waveforms. A 17-year-old patient with epilepsy manifested as recurrent myoclonic seizures, absence seizures, and a single generalized tonic–clonic seizure was hospitalized to undergo video-EEG monitoring for seizure quantification and classification of the epilepsy syndrome. During the monitoring session, a frontocentral predominant 5 to 6 Hz theta rhythm was identified only when the patient was actively texting or playing a video game on his smartphone. Previously, patients with focal epilepsy have been found to have a frontocentral theta rhythm on EEG while texting on mobile devices. We report similar EEG findings in a patient with genetic generalized epilepsy during smartphone gaming to expand the population and triggers for this theta waveform. Given the young age and type of epilepsy, we suggest that the waveform represents the EEG manifestation of the attention–visuomotor pathway that is stimulus independent.
A Case of Two Repeats: Huntington's Disease and Spinocerebellar Ataxia Type 8